  MUST2, Page 1 of 48  Not logged in MUST2
Pinned, e748, Thu Mar 23 11:19:13 2017, Adrien Matta, , , , Schedule 
This message will contain the update schedule of the preparation of e748.

Beam time: 1st - 9th of July 2017.
Pinned, General, Fri Mar 24 09:32:11 2017, Adrien Matta, MUST2, Software, , Usefull document for MUST2 operations NOTICE_UTILISATION_MUVI_HARD_et_SOFT_(ver_081013).pdfMUVI_card_USER_MANUAL_(ver_081013).pdf
DAS Configuration:
http://wiki.ganil.fr/gap/wiki/Documentation/Software/DAS
Fixed, e748, Wed May 24 09:07:59 2017, Adrien Matta, OTHER, General, , e748 Planning 
Feel free to edit this spread sheet.

Pinned, e748, Wed May 24 09:19:57 2017, Adrien Matta, OTHER, Social, , e748 Collaborators 
List of Collaborators (Please edit if anyone is missing):

[B]IPNOrsay[/B]: D Beaumel, Y. Blumendfeld, M Assie, N de Sereville, F Flavigny, S Franchoo, A Georgiadiou, J. Guillot, F. Hammache, I. Stefan, P. Asdley,
Fixed, e748, Wed May 24 09:32:41 2017, Adrien Matta, MUST2, Hardware, , Mounting of the telescope in G3 
The telescope has been mounted in there stand in G3. 

[LIST]
Fixed, e748, Wed May 24 09:35:00 2017, Adrien Matta, CATS, Hardware, , BTD chambers mounting in D6 
Sebastient started mounting the BTD chamber in D6. 
The frame is in place, BTD chambers one and 2 are mounted. 
CATS1 is in BTD1, CATS 2 remain to be mounted. 
Fixed, e748, Wed May 24 15:48:24 2017, Adrien Matta, MUST2, Hardware, , PCB number for each telescope 
[LIST]
[*] T1 PCB 5
[*] T2 PCB 9
Fixed, e748, Thu Jun 1 09:29:50 2017, Adrien Matta, MUST2, Hardware, , Telescope cabling debbug in G3 
Test performed without vaccum, in the dark, cooling at 20.

[LIST]
Fixed, e748, Thu Jun 1 09:32:38 2017, Adrien Matta, MUST2, Hardware, , MUST2 cabling scheme 
The MUST2 cabling scheme has been change so Telescope 1 to 4 and 5 to 8 are on two independent set of distribution box and HV Card.

Telescope 1 to 4 are on the small distribution box and the first HV card. This correspond to the down stream flange.
Fixed, e748, Fri Jun 2 12:03:32 2017, Adrien, Laurent, Shumpei, MUST2, Hardware, , M2C vacuum test 
We mounted 2 dry pump on the chamber and started pumping at 11h.
Pressure was about 6e-1 mbar around 11h45.
Waiting to switch on the turbo at 1e-1 mbar.
Fixed, e748, Tue Jun 6 09:07:34 2017, Adrien Matta, BEAM, General, , Moving to D6 
M2C Chamber now in D6 after a smooth ride, ready to be aligned.
Ongoing, e748, Tue Jun 6 17:57:07 2017, Valérian et François, EXL, Hardware, , Hardware coupling of EXL with MUST2 EXL_MUST2_top.png

EXL seems to fit in Adrien's setup. We still have to check if it fits in the chamber. 
Fixed, e748, Tue Jun 6 18:17:03 2017, Valérian et François, EXL, Hardware, , Hardware coupling of EXL with MUST2 EXL_MUST2_top.jpgEXL_MUST2_side.jpg
EXL seems to fit with Adrien's setup. 
We still have to test if it fits inside the chamber.
Fixed, e748, Wed Jun 7 11:29:55 2017, Adrien, MECH, Hardware, N/A, Surveyor mesurement 
The surveyor are carrying out the measurement of the detectors in D6.
The measurement should take the day, starting with the main plate, and then in the afternoon the detectors.
Fixed, e748, Wed Jun 7 18:03:02 2017, Franck, OTHER, Hardware, , LPC electronics 
Caen N568B: 509, 490
Ortec TAC: 1102, 1479, 1480, 1481
Lecroy GDG222: E2557, 01175C, 831
Fixed, e748, Thu Jun 8 18:57:14 2017, Valérie Lapoux, MUST2, Hardware, , Currents and Voltages on MUST2  
Thursday 8th June. 
Vacuum in the chamber 9e-05 mbar; MUST2 temperature at -5°C.
Low voltages and HV ON 
Fixed, e748, Fri Jun 9 12:30:49 2017, Adrien, VACUUM, Hardware, , Vacuum Leaks 
We reach a stable 1e-5 mbar. We performed a leak check and identify that the Ionisation chamber gate valve is not totally tight, I don't think there is
much to be done.
One of the M2C flange also have a micro leak, that we will solve next tuesday when reopening the chamber.
Fixed, e748, Fri Jun 9 12:33:25 2017, Adrien, MECH, General, , MUST2 position 
After a the surveyor came we figured out the MUST2 telescope are 1cm too high with respect to the beam line.
Vincent is preparing new feet to replace the one supporting the main plate. We will support the plate with adjustable one while replacing the other so
there is no need to dismount any detector.
Fixed, e748, Fri Jun 9 12:34:18 2017, Adrien, DAQ, Hardware, , Hub 
We are currentlky waiting for the hub to be configured so we can start the MUST2 DAQ. Should be done in the afternoon.
Fixed, e748, Fri Jun 9 12:35:46 2017, Adrien, MUST2, Hardware, , CsI trip on T6 
The detector were left on during the night. T6 CsI trip and cannot be switch on again. Once we established that all the MUFFEE works correctly we will start
investigating the issue, perhaps coming from the distribution box.
Fixed, e748, Fri Jun 9 14:41:54 2017, e748, CATS, General, , Runs 1 - 4 
Tests alpha source, dummy data
Pinned, e748, Fri Jun 9 15:49:46 2017, Valérie Lapoux, MUST2, Hardware, , MUST2 configuration Confige748MUST2alimHVandLV.pdfpréparationMUST2forE748.pdf
The MUST2 configurations for telescopes in the chamber and low/High voltage Caen crate are given in the attached file.
Pinned, e748, Fri Jun 9 15:51:44 2017, Valérie Lapoux, MUST2, Hardware, , General Trigger GMT for MUST2 electronics DaqElectronicsMUST2gmtforE748.pdf
The GMT configuration for the trigger inputs and the inputs from MUST2 electronics are given in the file.
Fixed, e748, Mon Jun 12 11:34:07 2017, e748, MUST2, Hardware, , MUVI cars setup 
We had problem with MUVI1 (pre serie 1) not working properly when a telescope was pluggeg (but fine otherwise).
Charles Houarner changed the card to MUVI serie 5, and the card is now working.
Fixed, e748, Mon Jun 12 11:36:34 2017, e748, MUST2, Hardware, , I2C error on Telescope 
At the Moment we got I2C error on the following detectors:

[LIST]
Fixed, e748, Mon Jun 12 11:50:34 2017, e748, CATS, Software, , Settings QDC 
Gates QDC CATS1X, CATS1Y, CATS2X, CATS2Y: 0.996
Pedestal QDC CATS1X, CATS1Y, CATS2X: 0.5
Pedestal QDC CATS2Y: 0.699
Fixed, e748, Mon Jun 12 11:52:16 2017, e748, CATS, General, , Run 6 and 7: Calibration Runs CATS Capture.png
Run 6: Calib CATS1 X&Y
--> Full, x2, x5, pedestal
Fixed, e748, Mon Jun 12 11:55:27 2017, e748, CATS, General, , Run 5 - JUNK pulser run on CATS1 
Dummy run with pulser.
JUNK
Fixed, e748, Mon Jun 12 14:09:24 2017, e748, CATS, Software, , calibration coefficients Runs 6-7 CATS_Pulser_Calib_Run6-7.pngCATS1_X.e748CATS1_Y.e748CATS2_X.e748CATS2_Y.e748
columns are for 1st order calib (y= ax + b):
pedestal - b - a
Fixed, e748, Mon Jun 12 16:56:36 2017, e748, OTHER, General, , e748 Proposal Matta_PAC_GANIL_June_2016_v3.pdf
Experiment proposal
Fixed, e748, Mon Jun 12 22:48:45 2017, Valérie Lapoux, MUST2, General, , Tests of the DAQ with the Alpha Source 8x
12Th June. 3-peak Alpha source rotated towards the telescopes MM1 to MM4 (square wall of 4 telescopes).
MUVI configurations are fixed on the DAS. See pictures below. Thresholds : 402 keV.
We have DAS error messages for telescopes T2 and T7 with problems of data transmission, "I2C errors" = logic signals problems, maybe due to 
Pinned, e748, Tue Jun 13 11:14:23 2017, Valérie Lapoux, MUST2, General, , GMT configuration, FAG GMTconfigOKMust2FAG100ns.pngGMTtrigParamActions.pngGMTparamDASgatconf.png
The Gatconf parameter is now defined in the action file.
The new configuration for GMT (see chronogramme plot) is attached, with the FAG window width set at 100 ns.
Fixed, e748, Wed Jun 14 12:13:00 2017, e748, MUST2, Hardware, , MUST2 I2C Err debugging 
It appears several SL cables are faulty.
To avoid manipulation of all the cable we now have T1-4 working. These required to scavenge SL T5 and give it to T2.
Pinned, e748, Thu Jun 15 10:16:03 2017, Valérie Lapoux, MUST2, Hardware, , Electronics for GMT trigger and FAG DaqElectronicsMUST2gmtforE748.pdf
The GMT is used in a mode where we do not make coincidence and decision, GMT entries are single and all accepted as triggers of the DAQ.
The FAG window for the GMT should be set at a low value, typically 100 ns.
Fixed, e748, Thu Jun 15 17:51:15 2017, e748, RUN, General, 3-alpha, Run 5-7 MUST2_EXT2.png
[SIZE=3]run5[/SIZE]

alpha source 
Fixed, e748, Fri Jun 16 09:57:54 2017, e748, RUN, General, 3-alpha, Run 11 
RUN 11 : alpha calibration with suppression of zeros ( & alignment of pedestals) for all night
Fixed, e748, Fri Jun 16 09:59:00 2017, e748, RUN, General, 60Co, Run 12 exl_co_source.pngexl_co_source_i.png
RUN 12 : EXL trigger in GMT
+ gamma source 60Co
Fixed, e748, Sat Jun 17 10:22:43 2017, Adrien Matta, EXL, Hardware, , EXL ADC gate 
EXL ADC is now setup with individual gate on the ADC. 

We also put the threshold higher to reduce the rate and managed to work on timing.
Fixed, e748, Sat Jun 17 10:27:26 2017, Adrien Matta, ONLINE, Software, , Starting the GRU online analysis 
We setup a script to start the right environment to run GRU, ganil2root and nptool.

The script is located in /home/muvi/e748 and can be accessed by just typing online in the terminal.
Fixed, e748, Sat Jun 17 10:32:25 2017, Adrien Matta, ONLINE, Software, , Online/Offline list of task 
We need to do the following improvement to the online / offline environment:

[LIST]
Fixed, e748, Sat Jun 17 10:56:09 2017, Adrien Matta, BEAM, General, , JC Thomas plans for the beam production REX-E628.pdf
Here are a few notes by Jean Charles about the expected LISE setting based on 2013 and 2014 16C tuning.
Fixed, e748, Mon Jun 19 16:03:18 2017, e748, EXL, General, , Progress On EXL 
We fiddled around with EXL trying to get a reasonnable 60Co spectrum.

We moved the source to the windows flange, so it is now facing the EXL detector with minimal matters inbetween, although rather far away (around 1m).
Fixed, e748, Mon Jun 19 16:04:51 2017, e748, RUN, General, 3-alpha, Run 15 
Run 15 is started.
Source: We have a 3 alpha source in target position and a 60Co on the window flange.
Trigger: EXL
Fixed, e748, Mon Jun 19 16:36:07 2017, e748, EXL, Hardware, , Gain changed on EXL 
Run 15 online analysis showed waht we believe was 4 MeV range.

So we change the hardware gain on EXL to 2 on the first module and 5 on the second one (channel 17 and 18).
Fixed, e748, Mon Jun 19 16:36:31 2017, e748, RUN, General, 60Co, Run 16 
Run 16 is started.
Source: We have a 3 alpha source in target position and a 60Co on the window flange.
Trigger: EXL
Fixed, e748, Mon Jun 19 18:02:16 2017, e748, RUN, General, 60Co, Run 17 
Run 15 is started.
We have a 3 alpha source in target position and a 60Co on the window flange.
Trigger: EXL
Fixed, e748, Mon Jun 19 18:07:55 2017, e748, EXL, Hardware, , Threshold changed on EXL 
Run 15 online analysis showed what we believe was 4 MeV range.

We set the threshold channel by channel:
Fixed, e748, Tue Jun 20 09:08:46 2017, e748, EXL, General, , EXL Spectrum with 60Co source exl_60co.ps
Here is a spectrum of EXL after one night of accumulating stat on 60Co.
Fixed, e748, Wed Jun 21 09:05:26 2017, Adrien Matta, Phil Adsley, MUST2, General, , MUST2 Dead Time 
We cabled the Dead time in the scaler.
We have a 100Hz pulser (entry 2 of U2M) in coincidence with the DT output of the GMT (entry 1), giving a direct reading of the dead time.
Fixed, e748, Wed Jun 21 09:39:38 2017, e748, DAQ, General, , Backup of config file must2.tar.gz
ganacq manip back up.
Fixed, e748, Thu Jun 22 10:24:12 2017, e748, CATS, Software, , Manip config file backup before merge e748_cats.tar.gz
Manip config file backup before merge
Fixed, e748, Thu Jun 22 11:10:35 2017, Valérian, EXL, Software, , EXL Mapping Mapping_of_EXL_in_analysis.pdf
Mapping of the EXL detector in the analysis program versus how it is written on the cables.
Fixed, e748, Thu Jun 22 17:46:45 2017, e748, MUST2, Hardware, , MUST2 SL cable repair 
Three cables came back from ASCO, two of them were the original spare cables.

Report from ASCO:
Fixed, e748, Thu Jun 22 17:49:20 2017, Adrien and Phil , MUST2, General, , MUST2 telescope test with alpha source T14_X.pdfT14_Y.pdfT58_X.pdfT58_Y.pdf
All Telescope now pass the I2C test.

We ran with an alpha source (attached pictures for the overall sequence), 
Fixed, e748, Thu Jun 22 17:55:52 2017, e748, MUST2, Hardware, , Surveyor mesurement 
The surveyor are missing some point for the telescope measurement.

We reopen tommorrow to fix T5 and let them retake the missing points.
Fixed, e748, Fri Jun 23 09:18:14 2017, e748, OTHER, General, , Plan for 23rd of June 
We have to open today, I started warming up of the telescope at 9h18 today.

Once open, we have to check on T5 DSSD capton and fix them.
Fixed, e748, Fri Jun 23 09:20:33 2017, e748, OTHER, General, , Plan for coming days 
23rd of June:
    Fix T5
    Surveyor measurement
Fixed, e748, Fri Jun 23 16:37:54 2017, Adrien, Laurent, Vincent, OTHER, Hardware, , MUST2 chamber opening IMG_1936.JPG
We opened the chamber and the surveyor took there measurement.

We closed the chamber with a 3 alpha source in the target position and a 60Co source on top.
Fixed, e748, Fri Jun 23 20:49:49 2017, Adrien, MUST2, General, , Restart 
Chamber at 2e-5, cooling -9deg outside; -5 on copper LV off.

Starting BT and HV. No trip; normal current (1-2ua on DSSD; ~0.01 on CsI, still high current,9ua at 450V SiLi1 T5, other SiLi at 4-5ua).
Fixed, e748, Sat Jun 24 21:41:30 2017, e748, MUST2, General, , Pedestal alignement and calibration 
MUSt2 pedestal aligned for all telescope.

Started alpha run with all telescope in trigger as well as EXL.
Fixed, e748, Sun Jun 25 09:53:44 2017, Adrien Matta, RUN, General, 3-alpha, Run 18 
Junk
Fixed, e748, Sun Jun 25 09:54:08 2017, Adrien Matta, RUN, General, 3-alpha, Run 19  
Source: 3-alpha + 60Co
Trigger: T1-8 or EXL
Fixed, e748, Mon Jun 26 09:15:31 2017, Adrien Matta, RUN, General, 3-alpha, Run 19 : disk quota exceeded 
Run 19 was still running this morning, but file stop writting at 6 O'Clock, when the disk quota exceeded (we wrtoe about 14Go of data, so not that much!)
Fixed, e748, Mon Jun 26 10:26:16 2017, Valérian, EXL, Software, 60Co, Add-back addback.pdf
We implemented the add-back correction with cross-talk subtraction.

On the joined graph, RawEnergy correspond to the sum of the energy in every crystals and Energy correspond to the sum of energy in every crystals with
Fixed, e748, Mon Jun 26 17:38:32 2017, e748, MUST2, General, N/A, CALIMERO 
Luc and Greg fixed Calimero, We have to perform the calibration but there is some work going on with CATS.
Fixed, e748, Tue Jun 27 10:15:38 2017, e748, DAQ, General, , Scalers 
CATS were added to the scalers:
T CATS1 : 3rd scaler channel
T CATS2 : 4th scaler channel 
Fixed, e748, Tue Jun 27 13:47:15 2017, e748, RUN, General, N/A, Run 21 
Calib CATS1:
pedestal - x5  - x2 - full
Fixed, e748, Tue Jun 27 13:47:57 2017, e748, RUN, General, N/A, Run 22, 23 
JUNK
Fixed, e748, Tue Jun 27 13:48:22 2017, e748, RUN, General, N/A, Run 24 
CALIB CATS2:
x5 - x2 - full - pedestal
Fixed, e748, Tue Jun 27 15:39:04 2017, e748, RUN, General, N/A, Run 26 
Calib Cats 2

pedestal, x5, x2, full
Fixed, e748, Tue Jun 27 15:41:53 2017, e748, RUN, General, N/A, Run 27 
Calib CATS 1
pedestal, x5, x2, full
Fixed, e748, Tue Jun 27 17:41:17 2017, e748, RUN, General, 3-alpha, run 28 
Started run #28
3-alpha
Fixed, e748, Tue Jun 27 17:51:24 2017, e748, RUN, General, 3-alpha, Run 29 
Started run #29 at 17h45
3-alpha around 90deg
Fixed, e748, Wed Jun 28 10:52:15 2017, Valérie Lapoux, MUST2, General, , Memo for CALIMERO MUST2 Time Calibration ConfigDAQDasCalimerov2017vlxTMP.pdf
Temporary file indicating the main steps for the time calibration of MUST2 using the Calimero DAQ package program.
Fixed, e748, Wed Jun 28 10:54:34 2017, Valérie Lapoux, RUN, Software, , DAQ problems due to TCP/IP errors ProblemRun29TCPerror.png
Problems occurred during the run #29 at 2h38 Wed. 28th June, with the following error messages written in the Run Control GUI window:

Error rcc MUST2:VMECOM :TCP error  TCP/IP time-out
Fixed, e748, Wed Jun 28 11:02:38 2017, Valérie Lapoux, RUN, General, 3-alpha, Calibration run #31 with Alpha source - MM5 and MM8 Run31startNarvalAlphaSource.png
Run #31 started at 11:01, Wednesday 28th June.
The alpha source is rotated towards the telescopes 5, 8.
Fixed, e748, Wed Jun 28 11:42:06 2017, e748, CATS, General, N/A, Surveyor's positions CATS Position_geometre_CATS.png
 
Fixed, e748, Wed Jun 28 15:07:43 2017, Thomas, CHIO, Software, N/A, Trapezoidal filter for CHIO 
const int nCHIO=200; // nb samples. sera ajuste en manip    
 
 float SIG[nCHIO];
Fixed, e748, Wed Jun 28 15:17:24 2017, Valérie Lapoux, RUN, General, , End of run 31-status Run31stopProbTimeoutGanlx9Chio.png
Run #31 started at 11h01; stopped at 15h13
Problem on ganlx9 VME Chio
 TIMEOUT on the stop process.
Fixed, e748, Thu Jun 29 10:44:45 2017, e748, TARGET, Hardware, CD2, Target and Mask are Mounted IMG_1973.JPGIMG_1954.JPGIMG_1953.JPGIMG_1974.JPG
We mounted the target and mask in the chamber before closing:

The target order on the ladder is the following, starting from the bottom (Target ladder fully flushed inside the chamber with no spacer):
Fixed, e748, Thu Jun 29 23:26:10 2017, Valérie Lapoux, RUN, General, Empty, ALL CALIMERO Time Calibration MUVI1 CalimeroRunControl.pngConfigCalimeroStat.pngCalibTmuvi1Yperiod20nsrange600ns.pngTimeMust2X_MUVI1_uncalib.pngTimeMust2Y_MUVI1_uncalib.png
29 JUNE 2017 
CONDITIONS FOR CALIMERO CALIBRATIONS
Time calibrator Period 20ns ; range 512 ns
Fixed, e748, Fri Jun 30 00:33:36 2017, Valérie Lapoux, RUN, General, Empty, ALL CALIMERO Time Calibration MUVI2 CalibTimeMUVI2stripXT.pngSpectresMUVI2stripXT300ns.png
30 JUNE 2017
CONDITIONS FOR CALIMERO CALIBRATIONS
Time calibrator Period 20ns ; range 512 ns
Fixed, e748, Fri Jun 30 01:01:08 2017, Valérie Lapoux, RUN, General, Empty, ALL CALIMERO Time Calibration MUVI2 GOOD RUNS 600ns TimeMust2X_MUVI2_uncalib.pngTimeMust2Y_MUVI2_uncalib.png
[B]RANGE TAC MUST2 600ns
CALIMERO TIME CALIBRATOR PERIOD 20ns; Range 512ns[/B]
[B]RUN  40[/B] started 00H53  ; stop   30 juin 01:19
Fixed, e748, Fri Jun 30 02:00:44 2017, e748, MUST2, Hardware, N/A, Warming up of detector started 
All LV and HT off, vaccumm at 1.3e-5 mbar, starting warm up sequence.
Fixed, e748, Fri Jun 30 11:09:59 2017, Freddy, OFFLINE, General, , Analysis of DSSD Energy Calibration - alpha source run19_Summary_EX.pdfrun19_Summary_EY.pdf
We made a calibration with the last alpha source runs:
-run 19 for T1-2-3-4
-run 29 for T5 and T8
Fixed, e748, Fri Jun 30 12:24:17 2017, Valérie Lapoux, DAQ, General, , DAQ Parameters: TAC, Caviar, LISE D4, D6, Caviar DASParamVXIMust2CatsTACLise.pngDASParamVXIChioQDC.pngDASParamVXIChioADClisepar.png
 
Fixed, e748, Fri Jun 30 16:49:49 2017, Valérie Lapoux, DAQ, General, , GMT triggers and chronograph DASConfigTriggerGMT.pngChronogrammeGMT30juinFAG100nsCT5µs.png
Configurations for the GMT inputs.
30 June 2017 pm
all Must2 telescopes,
Fixed, e748, Fri Jun 30 16:55:04 2017, Valérie Lapoux, DAQ, General, , Run control for global DAQ with NUMEXO RunControlAll748ModeMonitoring.pngNarvalRunControlAllE748.png
The run start/stop sequence for the global DAQ including the NUMEXO:

I. ssh e748chio@ganp976
Fixed, e748, Fri Jun 30 17:53:35 2017, Valérie Lapoux, DAQ, General, , Scalers parameters U2M Actionse748ganlx11withU2M.pngScalerAnalyzerU2M.png
 
Fixed, e748, Fri Jun 30 20:46:16 2017, Valérie Lapoux, TARGET, General, , TARGET configuration 
List of the reaction target in the chamber from bottom to up:

 6. EMPTY FRAME (no frame) 
Fixed, e748, Sat Jul 1 09:27:46 2017, Adrien Matta, OTHER, General, N/A, SHIFT TABLE 
 
Fixed, e748, Sat Jul 1 10:47:18 2017, Adrien Matta, BEAM, General, N/A, Primary beam energy measurement IMG_1984.JPG
PCP delivered the primary beam energy measurement
Fixed, , Sat Jul 1 12:45:25 2017, Anastasia , CATS, General, , CATS Calibrated cats_calibrated.png
run_0026 CATS 1 X Y
run_0027 CATS 2 X Y
Fixed, e748, Sat Jul 1 14:32:02 2017, Valérie Lapoux, DAQ, General, , Scalers U2M, parameters ScalersU2Mok.pngCompilActionsganlx11ScalerGr1to4..png
U2M configuration +Actions ganlx11

The signals for the scalers are converted from NIM to ECL in a 16 channel module NIM-ECL.
Fixed, e748, Sat Jul 1 14:45:17 2017, Valérie Lapoux, DAQ, General, , Parameters for correlation checkings 
The [B]parameters[/B] to be used for the checking of the correlations between crates/VME/VXI and good running of the merging
conditions of the different DAQs are : 
- for MUST2 VXI with the GMT: [B]GATCONF[/B]
Fixed, e748, Sat Jul 1 15:12:01 2017, Valérie Lapoux, ONLINE, Hardware, , Conditions for Bidiv and TAC 1st July 15pm 
(Update the file CONDTIONS748.txt during the experiment)

JULY 1st 15pm
Fixed, , Sat Jul 1 17:09:04 2017, e748, MUST2, General, , TIME CAL CHECK must2_time_cal_run40.png
run_0040_CalMust2Histos.root
Fixed, e748, Sat Jul 1 22:16:46 2017, e748, DAQ, General, N/A, Problem of Merge 
The DAQ was not merging properly.
We figured out that the centrum was goiging out of sync when the run was stopped.
Fred added in the action file the reset of the event number in the INIT RUN block.
Fixed, e748, Sun Jul 2 03:46:11 2017, e748, OTHER, Hardware, , UPDATE OF TAC settings 
Here are several changes made during the night to optimize timing for TACs:

TAC PL-CATS1
Fixed, e748, Sun Jul 2 04:58:36 2017, e748, RUN, General, N/A, Run 74: MASK IN 
Starting Run 74 with trigger plastic and MASK at target position.

Intensity is set around 6-10kHz
Fixed, e748, Sun Jul 2 05:45:18 2017, e748, CATS, Software, N/A, Mask CATS 2 Run75MaskCATS2.png
Run 75 

shift surveyor
Fixed, e748, Sun Jul 2 05:56:12 2017, e748, CATS, Software, N/A, Mask on target Run74MaskTarget.pngRun74MaskTarget_Offsetmv.png
Run 74 Mask on target

With surveyor offsets and the inversion X -> -X on CATS1 (determined with run 75), 2 holes are observed. see figure Run74MaskTarget.png
Fixed, e748, Sun Jul 2 08:06:53 2017, Valérie Lapoux, RUN, General, CD2, Run 77 global check 6x
Conditions of Run 77

2 July - start at 6h29 - stop at 8h38 
Fixed, e748, Sun Jul 2 08:40:25 2017, Valérie Lapoux, RUN, General, CD2, Run 78 - 2 July - 18O beam  Run78ConfdevDataTrig.pngRUN78tPLcats1CORREL.pngRun78CorrelWindowtimePlastCats1.pngRun78TACplastCats.pngRun78TrigMM2impact.png
  Run #78 CD2 2.5 mg/cm2 position 3 - 18O beam 
Same conditions as for Run 77
Triggers all MUST2, T1 to T8, GMT IN1 to IN8 
Fixed, e748, Sun Jul 2 08:46:13 2017, Valérie Lapoux, DAQ, Hardware, CD2, Summary of the TAC conditions 
JULY 2nd 8pm

Bidiv =  1 for CATS1 and 2
Fixed, e748, Sun Jul 2 09:54:05 2017, Valérie Lapoux, DAQ, General, CD2, Test of the TAC plast CATS ADC VXI Run78 InspectLinesVXIMust2Run78LTtAiCatsFAG.pngInspectVXIchioADCsignalTplchCATS1Run78.png
 
Fixed, e748, Sun Jul 2 10:31:48 2017, Valérie Lapoux, ONLINE, Hardware, CD2, Change of the electronics for TAC Plast CATS1 
Shift U (Béa +Vlx) entered in the room to check the electronics of Cats1 and of the TAC plast-Cats1
Now we have taken the output of one of the TAC : START=CATS1_FAG - STOP plast (no val)
We send it to a Linear Fifo from which it is duplicated for the ADC channels:
Fixed, e748, Sun Jul 2 10:44:59 2017, Valérie Lapoux, RUN, General, CD2, Run 79 Beam of 18O 8x
run_0079.dat.02-07-17_10h37m20s
Triggers : all MUST2 telescopes 1 to 8.
The pulser is ON again in the DAQ and Scaler Analyzer. See plots.
Fixed, e748, Sun Jul 2 11:38:03 2017, Valérie Lapoux, RUN, General, CD2, Runs 80-81 TESTS change of TAC and triggers 
For runs 80- 81: 
for test purposes, we changed the coincidence mode for CATS: we put FAG instead of the Seq1 coming from the gamer.
Run 80 start 11h33; stop 11h40
Fixed, e748, Sun Jul 2 12:08:56 2017, Valérie Lapoux, RUN, General, CD2, Run 82 
Run82 start at 12h00 stop at 12h09
e748 Exxx    6684672  2 juil. 12:09 run_0082.dat.02-07-17_12h00m43s
Before starting run 82, we enter in the D6 room to restaure the electronics for CATS as it was before
Fixed, e748, Sun Jul 2 12:16:57 2017, Valérie Lapoux, RUN, General, CD2, Runs 83-84 only CATS1 trigger ScalersRun84Cats1trigg.pngConfigTRigCorrelMErgeRun84.png
Run83 start at 12h11 stop at 12h16
 e748 Exxx   21561344  2 juil. 12:16 run_0083.dat.02-07-17_12h11m16s
Fixed, e748, Sun Jul 2 13:22:46 2017, Valérie Lapoux, RUN, General, CD2, Run 85+summary TAC 
Started run #85 at 13h21 stop at 13h31
e748 Exxx    5439488  2 juil. 13:31 run_0085.dat.02-07-17_13h21m57s
Triggers all MUST2
Fixed, e748, Sun Jul 2 13:31:21 2017, Valérie Lapoux, RUN, General, CD2, Run 86 trigger CATS1 CorrelRun86mergeOKruncontrol.pngRun86TacPlastCATStrigCats1.png
Run 86 start at 13h32 stop at 13h43
 e748 Exxx   34340864  2 juil. 13:43 run_0086.dat.02-07-17_13h32m13s
 
Fixed, e748, Sun Jul 2 13:49:20 2017, Valérie Lapoux, RUN, General, CD2, Run 88 trigger CATS1 
Run 88 start at 13h48 
TRIGGER CATS1 div =100 only
18O beam CD2 target
Fixed, e748, Sun Jul 2 14:49:41 2017, Valérie Lapoux, ONLINE, Hardware, CD2, TAC and signals for Plast-CATS1 
Now we return to the situation of 2 TACs for the coding of the same time Plast-Cats1 in the 2 DAQs systems VXI_CHIO and VXI_MUST2.

TAC1 start CATS1val; STOP Plast (delayed by 200ns with DGG) range 1µs OUTPUT signal T_PL_CATS1 VXI_MUST2  ADC add=23
Fixed, e748, Sun Jul 2 14:54:39 2017, Valérie Lapoux, RUN, General, , Runs 90-92 Tuning of the cocktail beam in D4 
Runs 90 to 92 Tuning of LISE 
GMT Trigger IN13=Trig_LISE  (D4)
Fixed, e748, Sun Jul 2 15:13:49 2017, Valérie Lapoux, RUN, General, , Runs 93-94 Tuning of the cocktail beam in D6 ScalerAnalyzerCaviar15h29.png
Runs 93-94 Tuning of LISE 
GMT Trigger IN13=Trig_LISE (=D6)
 e748 Exxx   25493504  2 juil. 15:11 run_0093.dat.02-07-17_15h07m01s
Fixed, e748, Sun Jul 2 17:25:22 2017, Valérie Lapoux, DAQ, Hardware, CD2, ADC parameters-new ones for LISE +Pulser for Correlations DASVXIchioAdcLiseParam.pngConfigDASnew2ndJulyVXIMust2.png
New parameter for LISE in VXI_CHIO ADC_CHIO 
parameter TED4HF address=4 channel 5 (cable label "5" on connected, first branch of ADC_CHIO)
-------------------------------------------------------------------------------------
Fixed, e748, Sun Jul 2 18:19:24 2017, Valérie Lapoux, DAQ, Hardware, CD2, Change of DAQ parameters for LISE DASparamLISEVXIChioNEW.png
 
Fixed, e748, Sun Jul 2 18:27:48 2017, Valérie Lapoux, ONLINE, Software, , Narval configuration, Watcher ports RunControlRun101allwtch.png
New file xml is loaded with various Watchers, the corresponding ports 
Watcher 10205
Watcher  WatRaw 10206
Fixed, e748, Sun Jul 2 19:40:02 2017, Valérie Lapoux, DAQ, General, , Correlation parameters for ChiO in VXI-ChIO VXI_MUST2 Run104ChioCorrelPulser.png
- Parameters
VXI_CHIO
ADC_CHIO_V15 channel 16, add=15
Fixed, e748, Sun Jul 2 22:03:45 2017, e748, RUN, General, N/A, Run 118 

 -> bidon: Beam in D4 but Trig <> LISE
Fixed, e748, Sun Jul 2 23:20:43 2017, LISE team JCT+ChrS, BEAM, General, N/A, Identification plot LISE Run 119 Capture-2.png
Run 119 2nd July started at 22h20 (around)
Lise trigger
PID ED4_TED4HF without wedge 
Fixed, e748, Mon Jul 3 03:48:57 2017, e748, OFFLINE, General, , Correlation Test on Run 104 run_104_shifting.pdf

We analysed run 104 to check the correlation of events coded in different crates. It is clear now that the events from the MUST2 crate are shifted by +1
with respect to the CHIO crate.
Fixed, e748, Mon Jul 3 06:26:24 2017, e748, OTHER, General, N/A, Damned ELOG  
We just recovered the ELOG after 5-6 hrs out of order
Fixed, e748, Mon Jul 3 06:30:54 2017, e748, BEAM, General, N/A, 12Be beam rate  
Final 12Be beam rate as obtained by JCT with present wedge is about 6.10^3 per euA in D6
expected Imax of 18O is 6-7 euA
Fixed, e748, Mon Jul 3 06:30:58 2017, e748, DAQ, Software, , PROBLEM of conversion for RUN with even number 
[COLOR=red][B]IMPORTANT[/B][/COLOR]

We realized that starting at run 160 (included) all run with an even number (160,162,etc) give an error at conversion:
Fixed, e748, Mon Jul 3 07:04:30 2017, e748, OTHER, General, N/A, tritons 
Count rate in ZD plastic is bout 2;5 times larger than in CATS1 and CATS2, probably due to tritons 
Fixed, e748, Mon Jul 3 07:06:17 2017, e748, RUN, General, CD2, RUN 173 - First Physics with 12Be run173_MUST2_Ecal.pngrun173_MUST2_dEE.pngCapture-1.png
RUN 173

START: 6H11
Fixed, e748, Mon Jul 3 07:52:36 2017, e748, RUN, General, CD2, RUN 175 
[B]RUN 175
[/B]
 
Fixed, e748, Mon Jul 3 07:52:39 2017, e748, RUN, General, CD2, RUN 175 
[B]RUN 175
[/B]
 
Fixed, e748, Mon Jul 3 14:28:09 2017, Franck et Valérian, CHIO, Hardware, N/A, CHIO's electronic scheme Schema_electronique_CHIO.pdf
A quick scheme of the CHIO electronic. The patch outputs are the one from the LISE acquisition room.
Fixed, e748, Mon Jul 3 17:28:05 2017, e748 -Thomas R, Georges V, Sébastien H, CHIO, General, N/A, (Tentative) Solution to recover the CHIO: it works!  P2280767schemeChioElog.JPGP2280756OscilloChio.JPG
An interview of Th, Seb and Georges by Valérie on July 3rd.
Please indicate complements or corrections on this summary of the ionization chamber situation. 
We list here the problems during the last days and the solution adopted to recover it...
Fixed, e748, Mon Jul 3 17:31:08 2017, e748, OFFLINE, General, CD2, BEAM and FRAGMENT PID run_203_PID_SiD6.pdfrun_203_PID_beam.pdfrun_203_PID_reactionfrag.pdf
We used the Si in D6 and the TOF(CATS1-CAVIAR) to identify the beam nuclei.

Using a gate on 12Be and 11Be, we looked at the PID using Qplastic VS TOF(CATS1-CAV) and TOF(CATS1-PL).
Fixed, e748, Mon Jul 3 18:45:41 2017, Valérie L, DAQ, General, N/A, Checking ALL RUNS with Ganil_Tape  GanilTapeRun207.pngMessageRunControlNArval.pngRunControlOnNarvalAllWatcher.png
The problems with the runs which could not be converted during the night was due
to a double header buffers of the runs with an odd number.
Now it affects sometimes also runs with even numbers cf 206 below.
Fixed, e748, Mon Jul 3 19:43:16 2017, Franck, CHIO, Hardware, N/A, CHIO logic signals for TAC and CAEN digitizer 
STOP of CHIO CAEN digitizer = VAL AND Delayed CHIO (Delay = 700 ns). Before run 217, the CHIO was not delayed.
STOP of TAC PLASTval-CHIO = CHIO without delay. Before run 217 it was delayed CHIO.
Fixed, e748, Mon Jul 3 19:59:02 2017, Valérie L, RUN, General, CD2, Series of runs - afternoon/evening 3rd July 

Series of runs during the afternoon with the tuning of the ChIo and the tuning of the line
-------------------------------------------------------------------------------------------------------
Fixed, e748, Mon Jul 3 20:02:46 2017, e748, OFFLINE, General, CD2, run217 Capture.png
PID run 217
trigger = plast
Fixed, e748, Mon Jul 3 20:29:56 2017, Valérie L, RUN, General, CD2, Data runs after LISE tuning ScalersRun222trigPlastCATS1.png
The beam was tuned by the LISE team.
Beam conditions during the run 222 were changed to increase the beam at 1µA.
Beam rate on CATS: 9000/s; Plastic 24000/s FAG ~300/s.
Fixed, e748, Mon Jul 3 20:42:14 2017, Valérie L, RUN, General, CD2, Conditions for data runs, Run 223 TriggRun223AllMust2CatsPlast.png
Triggers for the experiments :MM1...MM8,
CATS1 div, Cats2div Plast div
All divisions on triggers are set at 100.
Fixed, e748, Mon Jul 3 21:13:18 2017, e748, OFFLINE, General, N/A, cats Capture.png
run222 cats
Fixed, e748, Mon Jul 3 21:41:57 2017, Valérie L, RUN, General, CD2, Runs 225-227 Run225l3julyScalerAnalyzer3µA.png
---------------------------------------------------------------------------------
3 µA at 21h25 ; CAVIAR D6 28000/s
CATS 20000/s
Fixed, , Mon Jul 3 22:10:28 2017, Valérie L, CATS, Hardware, CD2, VXI CATS crate problem solved  VisuCATproblemTerm.pngVXICATSreset.png
We had problems with CATS VME/VXI crate.
It was idle and it was not possible to restart it by breakup and init. 
We enter in the room to reset the ganlx7 of CATS.
Fixed, e748, Mon Jul 3 22:24:05 2017, Valérie L, RUN, General, CD2, Run series of problems 3rd July  
The daq was unstable with several problems of the merge from LISE.
We did tk kna (kill narval process) and na.
but the next run was starting still unstable with Error from the merge
Fixed, , Mon Jul 3 22:40:33 2017, e748, RUN, General, , Plastic_Cats_T run_223_tac2.pdfrun_223_tac1.pdf
Tac run_223
 
Range: T_CATS1_CAV 1 µs
Fixed, e748, Mon Jul 3 23:06:24 2017, Valérie L, RUN, General, CD2, Problem during Run 230-231 with CATS ResetEventCounterAfterRun230Centrum.pngPRoblemRun230.pngScalersRUn230.png
r-- 1 e748 Exxx   34013184  3 juil. 22:52 run_0230.dat.03-07-17_22h46m03s
-rw-r--r-- 1 e748 Exxx   97910784  3 juil. 23:09 run_0231.dat.03-07-17_22h54m42s
Fixed, e748, Mon Jul 3 23:16:33 2017, Valérie L, DAQ, General, CD2, Change of TAC RANGES (from run 230) 
TAC range changed after run 229.
NB: Change applied for Runs 230 and 231 
BUT these runs are not working due to problems of Merger
Fixed, , Tue Jul 4 00:53:18 2017, Valérie L, RUN, General, CD2, Runs with merge and time out problems 
-r--r--r-- 1 e748 Exxx     720896  3 juil. 21:55 run_0226.dat.03-07-17_21h54m51s
-rw-r--r-- 1 e748 Exxx     786432  3 juil. 21:56 run_0227.dat.03-07-17_21h55m56s
-r--r--r-- 1 e748 Exxx   57016320  3 juil. 22:16 run_0228.dat.03-07-17_22h12m59s
Fixed, , Tue Jul 4 00:54:41 2017, Valérie L, RUN, General, CD2, Runs after reset of VXI 

VXI CHIO was offline --> reset of ganlx9  (entering in D6) on the VXI crate 
Fixed, e748, Tue Jul 4 01:00:26 2017, Valérie L, RUN, General, CD2, Run 239 test with trigger MUST2 
Started run #239 4JULY start 00h59 stop 1h15
PROBLEM junk header checked with Ganil Tape
triggers only MUST2 IN1 to IN8
Fixed, e748, Tue Jul 4 01:17:35 2017, Valérie L, RUN, General, CD2, Run 240 
Run #240 4JULY start  1h17
(run ok checked with Ganil_Tape)
 All triggers   MUST2 IN1 to IN8, 
Fixed, e748, Tue Jul 4 01:21:04 2017, e748, OFFLINE, General, CD2, run 236 Capture.png
cats > target
cats > target, gated by must
Fixed, e748, Tue Jul 4 02:33:36 2017, Valérie L, shifts U+S Yorick, RUN, Hardware, , GMT channel 8  GMTtriggerRun248.pngGMTtriggerGatconfRun248.png
Apparently Channel 8 of the GMT is not operational. We put telescope T8 in entry 15.
This operation gives good results, see pictures below of Gatconf with 2**(N-1) = 2**14 = 16384 for Run 248.
Triggers GMT are now:
Fixed, e748, Tue Jul 4 04:01:50 2017, e748, RUN, Hardware, , RUN249 
RUN249 

Same setting as RUN248. 
Fixed, e748, Tue Jul 4 05:01:21 2017, Yorick, RUN, General, CD2, Runs 248-250 
These are long runs with CD2
MUST8 is in GMT 15.
Missing Times: T7 X and Y; T5 Y.
Fixed, e748, Tue Jul 4 05:08:30 2017, e748, MUST2, Hardware, , MUST2 signql check in offline analysis 
RUN248
MUST2 DSSD XE signal for all telescopes T1-T8 confirmed.
MUST2 DSSD YE signal for all telescopes T1-T8 confirmed.
Fixed, e748, Tue Jul 4 05:11:20 2017, e748, MUST2, Hardware, , MUST2 signql check in offline analysis 10x
RUN248
MUST2 DSSD XE signal for all telescopes T1-T8 confirmed.
MUST2 DSSD YE signal for all telescopes T1-T8 confirmed.
Fixed, e748, Tue Jul 4 05:20:31 2017, e748, RUN, Hardware, , RUN250 
Same setting as RUN248. 
run_0250.dat.04-07-17_04h58m50s
start 4h58 Gtape ok
Fixed, e748, Tue Jul 4 05:23:20 2017, e748, CATS, Software, , CATS signal run248_CATS1XQ.pngrun248_CATS1YQ.pngrun248_CAT2XQ.pngrun248_CATS2YQ.png
RUN248
The chqrge distribution of CATS1&2, X&Y
Gate:CATSdiv trigger
Fixed, e748, Tue Jul 4 07:00:55 2017, e748, RUN, Hardware, , RUN252 
Same setting as RUN248. 
RUN251 junk header
run_0252.dat.04-07-17_05h33m06s
Fixed, e748, Tue Jul 4 07:01:50 2017, e748, RUN, Hardware, , RUN254 
Same setting as RUN248. 
RUN253 junk header
run_0254.dat.04-07-17_06h32m10s
Fixed, e748, Tue Jul 4 07:37:09 2017, e748, RUN, Hardware, , RUN256 
Same setting as RUN248. 
RUN255 junk header
run_0256.dat.04-07-17_07h34m59s
Fixed, e748, Tue Jul 4 07:46:48 2017, e748, RUN, Hardware, , RUN258 
Same setting as RUN248. 
RUN257 junk header
run_0258.dat.04-07-17_07h45m32s
Fixed, e748, Tue Jul 4 08:36:50 2017, e748, RUN, Hardware, , RUN260 
Same setting as RUN248. 
RUN259 junk header
run_0260.dat.04-07-17_08h32m05s
Fixed, e748, Tue Jul 4 09:01:19 2017, e748, RUN, Hardware, , RUN262 
Same setting as RUN248. 
RUN261 junk header
run_0262.dat.04-07-17_08h56m13s
Fixed, e748, Tue Jul 4 09:48:53 2017, e748, RUN, General, CD2, Run 265 
Run 265: Trigger MUST Only
Fixed, e748, Tue Jul 4 09:49:52 2017, e748, RUN, General, CD2, Run 266 
Run 266: Trigger CATS1 Only
Fixed, e748, Tue Jul 4 09:50:11 2017, 7e748, RUN, General, CD2, Run 267 
Run 267: Trigger CATS2 Only
Fixed, e748, Tue Jul 4 09:51:55 2017, 8e748, RUN, General, CD2, Run 268 
Run 268: Trigger Plastic Only
Fixed, e748, Tue Jul 4 09:57:48 2017, e748, RUN, General, CD2, Run 269 
Run 269: Trigger MUST2 Only
Checking CHIO Digitization
Fixed, e748, Tue Jul 4 10:21:52 2017, e748, RUN, General, CD2, Run 270 
Run 270: Trigger CATS1 or CATS2 Only
Checking CHIO Digitization
Fixed, e748, Tue Jul 4 10:34:06 2017, e748, RUN, General, CD2, Run 271 
Run 271: Trigger [B]Telescope 2[/B]  Only  (this one sees less beam particles)
Checking CHIO Digitization
Fixed, e748, Tue Jul 4 11:00:21 2017, e748, RUN, General, CD2, Run 272 
Run 272: Trigger Plastic  Only 
Checking CHIO Digitization
Fixed, e748, Tue Jul 4 11:02:07 2017, e748, RUN, General, CD2, Run 273 
Run 273: Trigger CATS1 and CATS2  Only  
Checking CHIO Digitization
Fixed, e748, Tue Jul 4 11:04:46 2017, e748, RUN, General, CD2, Run 274 
Run 274: Trigger T5-8  Only  
Checking CHIO Digitization
Fixed, e748, Tue Jul 4 13:15:11 2017, e748, OTHER, General, N/A, troubles with CHIO digitizer 
 
1p.m.
CHIO Digitizer was fixed by Frederic and Charles;
Fixed, e748, Tue Jul 4 13:24:40 2017, e748, RUN, General, CD2, Run 293 
Run 293  
restart with all triggers. Chio digit fixed
Fixed, e748, Tue Jul 4 14:24:37 2017, e748, RUN, General, CD2, Run 296 
Run 296 
restart with all triggers. Chio digit fixed. NUMEXO started
Fixed, e748, Tue Jul 4 14:48:11 2017, 8e748, RUN, General, CD2, Run 296 
Run 298
restart with all triggers MUST2
Fixed, , Tue Jul 4 14:49:17 2017, e748, MUST2, General, , CsI THRESHOLD RUN 297 Pedestal_adjustment_CsIE.png
By removing the threshold in the CsI we can clearly see now the light particles well separated in the DE/E 
new Pedestal suppression window : 8180 
                                  8210
Fixed, e748, Tue Jul 4 15:50:02 2017, 8e748, RUN, General, CD2, Run 296 
Run 299
restart with all triggers MUST2
Fixed, e748, Tue Jul 4 18:29:39 2017, e748, MUST2, Software, N/A, Start a new acquisition with Numexo CaptureSResetCHIODig.png
-To start a run :

  START  Acquisition NUMEXO
Fixed, e748, Tue Jul 4 19:38:32 2017, e748, RUN, General, CD2, Run #323 main daq - Run #322 NUMEXO2 
Run #323 on main daq <=> Run #322 NUMEXO2
Physics run: 12Be on CD2 #3 2.5 mg
On next run we will try to have the correct run # on NUMEXO2
Fixed, e748, Tue Jul 4 20:27:59 2017, Franck et Valérian, CHIO, Hardware, N/A, UPDATE : CHIO's electronic scheme (valid from run 217) Schema_electronique_CHIO.pdf
Modification of the scheme to add the delay on the CHIO's logic signal for stop of the digitizer.
Fixed, e748, Tue Jul 4 20:30:52 2017, e748, RUN, General, CD2, Run #323 scaler capture Capture-SCALERANALYSER_run323.png
Run #323 scaler capture at 20h30
Fixed, e748, Wed Jul 5 00:29:06 2017, Valérie L, RUN, General, CD2, Summary of the evening runs 322(e748chio)-323 (e748) RunControlChIoRun322.pngRunControlRun323.png
============================================================================================================
[e748'@ganp616 run]$ cd /data/e748chioX/e748chio/acquisition/run
-r--r--r-- 1 e748chio Exxx 4194288609  4 juil. 20:33 run_0322.dat.04-07-17_19h26m13s
Fixed, e748, Wed Jul 5 00:40:36 2017, Valérie L, RUN, General, CD2, Overview of the evening config 322(e748chio)-323 (e748) ScalersRun323e748at0h48.pngConfigCEntrumE748.pngPulserChIoForScalerDAQ.png
BEAM conditions
CAVIAR LISE 35k
GMT TRiggers:
Fixed, e748, Wed Jul 5 00:58:43 2017, Valérie L, RUN, General, CD2, Overview of the evening plots Run323-e748 (Run 322 chio) 19x
Run 323 DAQ E748; Run 322 DAQ CHIO see plots below.

Run 323 
Fixed, e748, Wed Jul 5 01:07:15 2017, e748, OFFLINE, Software, , Merge of NUMEXO runs with standard runs run200_IC_numexodiff.pngrun300_ICENUMEXO_TCATSCAV.pngrun300_ICENUMEXO_TPLCATS1.pngrun300_TPLCHIO_LTSdiff.png
Here are some plots after offline merge correlation of the CHIO energy coded in NUMEX0 with other parameters.

First pictures concerns run300 with trigger MUST2 only. 
Fixed, e748, Wed Jul 5 03:35:53 2017, Valérie L, RUN, General, CD2, SiLi 1/T5 trip 
AT 3h30 we saw that the SiLi1 of T5 has tripped during the run run_0323.dat.04-07-17_19h25m59s.2 (run started at 2h22)

We put it On again. HV 400V I~ 6.5 µA
Fixed, e748, Wed Jul 5 04:34:06 2017, e748 shift U, RUN, General, CD2, Overview of Config and TAC during run 323 (.3) run_323_conf.pngrun_323_tac.png
The counting rates in the Gatconf, confdev, dataTrig of the different branches are checked in the first plot below.
The second picture is for the TAC.
Fixed, e748, Wed Jul 5 04:55:06 2017, Valérie L, RUN, General, CD2, Scalers and summary of Run 323 at 4h55-7h30 ScalersRun323AT4h54.pngRunControlBuffer5julyAt6h.png
E748 Runs (around 3h30 for 1Go)

Run 323_2  started at 2h22 stop 5h56
Fixed, e748, Wed Jul 5 06:11:47 2017, e748 shift U, RUN, General, CD2, Overview of Config +QplastTcats1 during run 323 (.5) Run323QplastTcatsconf.pngRunControlBuffer5julyAt6h.png
The counting rates in the Gatconf, confdev, dataTrig of the different branches are checked in the first plot below.
 
see plot Qplast %TplCats1 with the night statistics.
Fixed, e748, Wed Jul 5 08:10:03 2017, Valérie L, RUN, General, CD2, Run 325 DAQ 748- run 325 DAQ ChIo Run325DAQE748daqChIo.pngRun325ChioDigET.pngScalerAnalyserRun325at8h30.pngGMTtriggerAllRun325.png
We stopped the run 323 (DAQ E748) and run 322 (ChIo) when the beam was stopped by the machine during 10 minutes to check the beam intensity.

The run numbers for DAQ E748 and DAQ ChIo were realigned to 325 for both.
Fixed, e748, Wed Jul 5 09:13:17 2017, e748-A. Lemasson, CHIO, Hardware, CD2, CHIO cathode problems 
Thomas and Julien going to D6, the cathode power supply tripped.
Setting it back and we will check signal when beam is sent back.
Fixed, e748, Wed Jul 5 09:22:16 2017, Valérie L, RUN, General, CD2, Run 326DAQ- Run 326Chio Run326controlBuffer.pngScalerAnalyzerRun326.pngProblemCaviarEndOfRun326.png
Run 325 start at 9h19
We are running again after some change -switching on- of the power supply of the ChIo cathode).
End of run problem with the Caviar VME CPU seen offline.
Fixed, e748, Wed Jul 5 10:54:09 2017, Valérie L, RUN, General, CD2, SiLi 1/T5 trip 
AT 10h50 we saw that the SiLi1 of T5 has tripped during the run run_0328.dat.  (run started at 10h15 )

We put it On again. HV 400V I~ 10 µA increasing to 24-25µA
Fixed, e748, Wed Jul 5 10:58:54 2017, Valérie L, RUN, General, CD2, Run summary 327, 328 Run328Scaler.pngCheckParamBytesEvtNumexoRun328.png
run daq E748  (3h30 for 1Go)
-r--r--r-- 1 e748 Exxx  100M  5 juil. 10:14 run_0327.dat.05-07-17_09h55m11s
-rw-r--r-- 1 e748 Exxx  212M  5 juil. 10:55 run_0328.dat.05-07-17_10h14m56s
Fixed, e748, Wed Jul 5 11:10:48 2017, Valérie L., MUST2, General, CD2, Geometrical configurations for MUST2 ConfigGEOMImpactMUST2e748.pdf
 
Fixed, e748, Wed Jul 5 11:13:27 2017, Valérie L., MUST2, General, CD2, Power boards HV and LV for MUST2 ConfigHVetLVExpE748MUST2d6v2017.pdf
 
Fixed, e748, Wed Jul 5 14:34:15 2017, Marlene, RUN, General, CD2, Run summary 329,330 Scalers_run330.pngTAC_run330.pngcorr_run330.pngexl_run330.pngCapture-1.png
We thought the merge was broken, but the issue was the Raw Data gruscipt connecting to the wrong port.

Everything reestablished as before.
Fixed, e748, Wed Jul 5 15:30:03 2017, Freddy, OFFLINE, General, , MUST2 offline analysis of run 323 PID_M2_run332.png
Here is a plot of the MUST2 PID for telescope 3:
- dE - TOF with a veto on CsI_ to remove direct 12Be hitting the detector.
- dE - E ungated for a given crystal close to the beam axis
Fixed, e748, Wed Jul 5 17:15:57 2017, e748 DB, RUN, General, CD2, screenshot of scalers  Capture-run330.png
primary I = 6.9 uA

[IMG]elog:209/1[/IMG]
Fixed, e748, Wed Jul 5 18:36:49 2017, Freddy, OFFLINE, General, , PID from NUMEXO merged (partially) DeE_CHIO_NUMEXO_run323.png
Here is the PID(dE Vs E)  plot obained using the IC energy from NUMEXO Vs the plastic energy coded in our acquisition for the long run of last night (323)

The resolution is indeed about 10% (estimated on the 12Be spot.
Fixed, e748, Wed Jul 5 18:47:25 2017, e748 DB, RUN, General, CD2, new run - 331 Capture-run331.png
primary I = 6.9 uA

[IMG]elog:211/1[/IMG]
Fixed, e748, Wed Jul 5 19:05:13 2017, e748 DB & IS, RUN, General, CD2, tritons in the beam Capture-tritons.png
Tritons can be seen from the following plot. Some of them cross target frame and then lose 1.5MeV in the DSSDs. 
12Be particles are stopped by the frame. 
Fixed, e748, Wed Jul 5 19:10:33 2017, e748 DB&IS, ONLINE, General, CD2, tritons in the beam Capture-tritons.png
Tritons can be seen from the following plot. Some of them cross target frame and then lose 1.5MeV in the DSSDs. 
12Be particles are stopped by the frame. 
Fixed, e748, Wed Jul 5 21:13:14 2017, e748 IS, RUN, General, CD2, RUN 331 scalers  
primary beam I = 6.5 uA unstable in the last 30 minutes (20h20 - 20h45)

[IMG]elog:209/1[/IMG]
Fixed, e748, Wed Jul 5 22:29:10 2017, e748 DB, ONLINE, General, CD2, trajectories Capture-traj.png
[IMG]elog:215/1[/IMG]
Fixed, e748, Thu Jul 6 00:07:33 2017, e748 DB, ONLINE, General, CD2, Strips CATS raw  Cats-raw-run331.png
[IMG]elog:216/1[/IMG]
Fixed, e748, Thu Jul 6 01:00:21 2017, Freddy, MUST2, Hardware, N/A, Problem with position of télescopes 6&7 Nouveau_document_2017-07-06.pdf
Due to a cabling problem telescope 6 was seen as telescope 7 and inversly.
Fixed, e748, Thu Jul 6 01:26:15 2017, Franck et Valérian, CHIO, Hardware, N/A, UPDATE : CHIO's electronic scheme (valid from run 293) Schema_electronique_CHIO.pdf
Since Run 293 inspection line of NUMEXO 2 has been used as input signal of CAEN digitizer.
Fixed, e748, Thu Jul 6 01:34:42 2017, e748, RUN, General, CD2, Run 331 (file change) Scalers_run331_2.png
1:25 file change -> run_0331.dat.05-07-17_18h45m44s.2
18O beam: 6.6 uAe
CATS1: 40000 cps
Fixed, , Thu Jul 6 02:02:48 2017, Anastasia, OFFLINE, General, , First signs of the elastic Elastic.png
Hereby you can see some first signs of the [U]elastic scattering[/U] [COLOR=purple]12Be(d,d)12Be[/COLOR]
with punch through events that will be later taken care of, after the calibration of[COLOR=blue] CsI[/COLOR].
Pinned, e748, Thu Jul 6 02:41:13 2017, Freddy and the night shifters, CHIO, General, , CHIO analog treatment 
Interestingly, the bipolar output of the amplifier of the CHIO sent (and splitted) to check correlation on the channel 15 of the ADC CHIO (or on channel
29 of the ADC MUST2) provides a much better resolution (about 10%) than the one obtained using the unipolar output that we were looking since then (about
20% resolution).
Fixed, e748, Thu Jul 6 03:03:39 2017, iFreddy and the night shifters, CHIO, General, , CHIO analog (unipolar and bipolar) and digital run323_chiocompare.pngDeE_CHIO_NUMEXO_run323.pngrun323_CHIO_DIGIVAEN.pdf
Interestingly, the bipolar output of the amplifier of the CHIO sent (and splitted) to check correlation on the channel 15 of the ADC CHIO (or on channel
29 of the ADC MUST2) provides a much better resolution (about 10%) than the one obtained using the unipolar output that we were looking since then (about
20% resolution).
Fixed, e748, Thu Jul 6 03:35:32 2017, e748, RUN, General, CD2, Run 331 (file change) Scalers_run331_3.png
3:30 file change -> run_0331.dat.05-07-17_18h45m44s.3
18O: 7.2 uAe
CATS1: 40000 cps
Fixed, e748, Thu Jul 6 05:48:26 2017, e748, MUST2, General, CD2, SiLi 1/T5 trip 
Restart SiLi 1/T5 that reached 26 uA and tripped a few minutes ago.
Current = 21 uA when biased up again, and reaches 24 uA in a few minutes.
Fixed, e748, Thu Jul 6 06:23:18 2017, e748, RUN, General, CD2, Run 331 (file change) scalers_run331_4.png
6:19 file change -> run_0331.dat.05-07-17_18h45m44s.4
18O 7.1 uAe
CATS1 : 36000 cps
Fixed, e748, Thu Jul 6 07:17:05 2017, e748, MUST2, General, CD2, SiLi 1/T5 trip 
SiLi 1/T5 tripped at 7:16.
We turn it on again immediately -> 23 uA
Fixed, e748, Thu Jul 6 07:23:22 2017, e748, MUST2, Software, CD2, MUST2 : VMECOM : TCP error - TCP/IP : time-out 
"MUST2 : VMECOM : TCP error - TCP/IP : time-out" at 7:19.
RRC shows MUST2 "OFFLINE"
We stop run 331 -> Doesn't stop
Fixed, e748, Thu Jul 6 07:58:09 2017, e748, MUST2, General, CD2, SiLi 1/T5 triped 
SiLi 1/T5 triped at 7:30. We leave it off while trying to restart the run control.
We turn it on again at 8:03.
Fixed, e748, Thu Jul 6 08:22:08 2017, Valérie L, RUN, General, CD2, Problem of DAQ and networks problems ProblèmeDAQ6juillet8h.pngProblemGUIRuncontrolNumExo.pngRebootsoftCrateAGAVApassword.pngProblemDAQ5juilletNumExo.png
After the problem on Run control and the offline of MUST2, the DAQ on numexo could not be started again.
see error messages below.
The soft "astreinte" was called at 8h20 and also the one of G2I at 8h30 for network problems.
Fixed, e748, Thu Jul 6 09:54:53 2017, Valérie L, RUN, General, CD2, Run control OK -Runs 339 and 340 CorrelBidimChioandplotCatsRun340.pngRun339scalers.pngScalersAnalyserRun340.png
After the reboot soft of the AGAVA NUMEXO and realignment of the TGS (time stamp Agava) the situation is stabilized.
The  "astreintes" for hardware (Gilles W) and software (Clotilde M) have rebooted from the Terminal the crates (AGAVA).
Antoine Lemasson has reloaded the setup of the GTS.
Fixed, e748, Thu Jul 6 10:35:50 2017, Valérie L, MUST2, General, CD2, Sili-1/T5 trip 
The Sili1 of T5 has tripped (again) at 10h30.
On again. 400V; I ~ 20µA at 10h40, still increasing 25.6µA at 11h30.(The limit Io is set at 26µA)
To regulate this detector the Vo set is put at 380V instead of 400V. Now I ~ 24.4µA.
Fixed, e748, Thu Jul 6 10:39:09 2017, BéaF & ValérieL - shift U, OFFLINE, General, , Test of merge on Run 339 run339_ICEdiff_LTSDIff_TrigM2.pngrun339_TAC_LTSDIff_TrigM2.png
spectra of the merge checked by Béa.
The merge is correct on the correlations cf plots below.
Fixed, e748, Thu Jul 6 11:41:20 2017, Valérie L, DAQ, General, N/A, MEMO START/STOP + AGAVA configuration in DAS AfterRebootAgavaRegStatusOx80entréeAfterAlignt.pngDasVMEChioCheckSamplesNumber.pngRunControl748On.pngRunControlNarvalE748chioON.pngParameterListWatcherOnRCe748chio.png
START/STOP of the DAQ
---------------------------------------------------------------------
START acquisition e748chio  (DAQ Numexo; in the Run Control display on ganp976)
Fixed, e748, Thu Jul 6 13:21:49 2017, Daisuke, RUN, Hardware, CD2, RUN340 
During RUN340 

13h10 The beam intensity dropped from 35 kpps to nearly zero. Iulian called PCP. They said they found the beam alignment was a bit off, so they were trying
Fixed, e748, Thu Jul 6 13:33:23 2017, e748, RUN, General, CD2, Stop of Run 340 due to beam problems 
The run 340 was stopped at 13h32. Before the stop fo the run the beam was unstable and stopped by machine team.

General DAQ e748  
Fixed, e748, Thu Jul 6 13:37:22 2017, Valérie L, RUN, General, CD2, Run 341 ScalersRun341Beginning.pngScalersRun341At14h35.png
Run 341 START AT 13h37 STOP AT 15h21 (beam stop see the ELOG entry Id=239)
At the beginning (cf scalers below) the beam was at 6µA (--> CATS at 30kcps/s), the machine needs to recover slowly to go to 7eµA.
(run checked with Ganil_Tape ok)
Fixed, e748, Thu Jul 6 13:37:37 2017, Adrien Matta, OFFLINE, General, N/A, Energy loss table for d, 3He and 3H 20x
Here it is!
Fixed, e748, Thu Jul 6 14:07:20 2017, Bea, OFFLINE, General, CD2, Convert & Merge Numexo Runs in ganp166 
To Convert run DAQ_general

offline
Fixed, e748, Thu Jul 6 15:24:25 2017, e748-shift U, BEAM, General, CD2, Beam stop, end of run 341 
The beam was stopped due to vacuum problem at CSS2.
End of run 341 at 15h21.
Fixed, e748, Thu Jul 6 17:05:51 2017, Valérie L, RUN, General, CD2, run 342 +overview of TAC ScalersRun342at17h10.pngCorrelDatTrigGatconfRun342.pngCorrelTpulserChiorun342.pngRun342_Tcats12.pngRun342_TACcats1.png
Beam recovered after shut down due to the vacuum problem (power supply on the vacuum system was off). Beam was off during 1h30.

Run 342 started at 17h04 
Fixed, e748, Thu Jul 6 19:17:12 2017, e748 MA, RUN, General, CD2, RUN 343 
Run 343
same conditions as run 342
beam=7uA
Fixed, e748, Thu Jul 6 20:07:46 2017, Daisuke + Thomas R+ Valérie L, CHIO, General, CD2, Problem of counting on Chio ScalersRun343At20h09.png
It seems that the ChIo is counting at a very low rate, around 100/s instead of 5000/s in previous runs.
Thomas R is called at 20h to fix the problem.
See scalers of Run 343 at 20h09.
Fixed, e748, Thu Jul 6 20:46:15 2017, Thomas R + shift U (Valérie L) +S (Daisuke, Marlène, Shumpei) , RUN, General, CD2, Run 345 DAQ+344 chio after chio problem ScalersRun345at20h54.png
The HV on cathode is now set again at 2900V. At 20h50 we get back the beam for the run.
(Grid still ok at 920V)
Beam problem cf the scalers. Losing beam somewhere.
Fixed, e748, Thu Jul 6 21:27:52 2017, Thomas R + shift U (Valérie L) +S (Daisuke, Marlène, Shumpei) , RUN, General, CD2, Run 345 beam intensity loss 
The beam rate was low after intervention with the CHIO HV. 

Thomas contacted Jean-Charles and PCP. It turned out that some quadrupoles (Q31, Q34, Q21) of LISE were turned off. Thomas put correct parameters and turned
Fixed, e748, Thu Jul 6 21:35:29 2017, Thomas R + shift U (Valérie L) +S (Daisuke, Marlène, Shumpei) , RUN, General, CD2, Run 346 e748+e748chio 6x

Run 346 started at 21h37
Beam around 7µA CATS 2 46k
Fixed, e748, Fri Jul 7 00:25:16 2017, e748, MUST2, Software, CD2, Calibration for CsI 
Rough energy calibration for CsI was performed (only for MM1 and MM4).

Calibration file is at
Fixed, e748, Fri Jul 7 00:42:50 2017, Shumpei, MUST2, Software, CD2, Calibration for CsI CsICalib.pdf
Rough energy calibration for CsI was performed (only for MM1 and MM4).
Method;
Gate DSSD (300 um) energy = 2 MeV. This corresponds to 
Fixed, e748, Fri Jul 7 00:43:51 2017, Shumpei, MUST2, Software, CD2, Calibration for CsI CsICalib.pdf
Rough energy calibration for CsI was performed (only for MM1 and MM4).
Method;
Gate DSSD (300 um) energy = 2 MeV. This corresponds to 
Fixed, e748, Fri Jul 7 02:28:26 2017, Anastasia + Didier, ONLINE, General, CD2, scalers during run 346 Capture-scalers-run346.png
[IMG]elog:249/1[/IMG]
Fixed, e748, Fri Jul 7 02:56:25 2017, Anastasia + Didier, ONLINE, General, CD2, CATS raw 2D charge during run 346 Capture-catsraw-run346.png
[IMG]elog:250/1[/IMG]
Fixed, , Fri Jul 7 06:55:54 2017, Anastasia + Iulian, ONLINE, General, CD2, Run 346  MUST2_7am.pngScalers7am_run346.png
Run 346 still running.
We see in the Must2 impact also the other two telescopes T6T7
and clearly the elastic in the E/Theta
Fixed, , Fri Jul 7 07:34:54 2017, Anastasia + Iulian, ONLINE, General, CD2, Run 346 
Beam intensity: 7.433 µA
Fixed, e748, Fri Jul 7 08:17:38 2017, e748, RUN, General, CD2, Run 347 Scalers_run347.png
Stop run 346 and start run 347 after rewriting parameters onto CHIO digitizer.
Digitized CHIO signals back in Vigru.
Fixed, e748, Fri Jul 7 08:56:43 2017, e748, MUST2, General, CD2, SiLi 1/T5 current 
SiLi 1/T5: 380V, 24.9 uA (current limit set at 26 uA)
Apparently, it hasn't triped since July 6, 10:35
Fixed, e748, Fri Jul 7 10:46:21 2017, e748, MUST2, General, CD2, SiLi 1/T5 current 
HV = 380 V
I = 25.1 uA
Fixed, e748, Fri Jul 7 10:56:12 2017, e748, RUN, General, CD2, Run 347 (file change) scalers_run347_1.png
10:50 data file change -> run_0347.dat.07-07-17_08h15m06s.1
18O: 7.5 uAe
CATS1 42 kcps
Fixed, e748, Fri Jul 7 12:00:29 2017, e748, RUN, General, CD2, Stop run 347 - Short machine problem 
Short beam interruption due to a machine problem. We stop run 347.
Fixed, e748, Fri Jul 7 12:02:02 2017, e748, RUN, General, CD2, Run 348 Scalers_run348.pngcorrel_run348.png
Restart after short machine problem.
Same conditions as previous run.
Fixed, e748, Fri Jul 7 15:15:42 2017, e748, BEAM, General, CD2, Runs 349 to 364 - 10Be LISE tuning 
Slits F31 = +/- 20 mm
Momentum acceptance = 2.5 % total
Fixed, e748, Fri Jul 7 15:20:45 2017, e748, BEAM, General, CD2, Run 365 - 10Be LISE tuning 
Slits F31 = +/- 4 mm
Momentum acceptance = 0.5 % total
2 uAe -> 80000 cps on CATS
Fixed, e748, Fri Jul 7 15:55:29 2017, e748, BEAM, General, CD2, Run 366 - 10Be tuning - Centering on TARGET run_366_dac2_moins3A_CATS.pngrun_366_dac2_moins3A_Target.png
FH31 slits = +/- 4 mm
DAC2 = -3 A
Fixed, e748, Fri Jul 7 16:01:22 2017, e748, RUN, General, CD2, Run 367 run_367_scalers.png
FH31 slits (momentum slits) = +/- 4 mm
DAC2 = -3 A
Triggers = MUST2, CATS1div, CATS2div
Fixed, e748, Fri Jul 7 16:32:24 2017, e748, RUN, General, CD2, summary of runs 363-367 

/data/e748X/e748/acquisition/run
r--r--r-- 1 e748 Exxx   19M  7 juil. 15:01 run_0363.dat.07-07-17_14h54m46s
Fixed, e748, Fri Jul 7 16:34:34 2017, e748 shift U Simon G. + Valérie L, RUN, General, CD2, Overview of Run 368 - 10Be beam 12x
Run 368 started at 16h30 stop at 18h01 (automatic stop)

Run  368_1 ongoing at 18h41
Fixed, , Fri Jul 7 18:04:58 2017, e748, OFFLINE, General, , Kinematic Line12Be(d,3He)11Li  kine.pdf
 
Fixed, e748, Fri Jul 7 18:18:13 2017, e748 Thomas R. +shift U Simon G +Valérie L, CHIO, General, CD2, Thomas's explanations on Agava P2280829explanationChIo.JPG

AGAVA
cf drawing below done by Thomas.
Fixed, e748, Fri Jul 7 20:26:30 2017, e748 shift U Simon G +Valérie L, RUN, General, CD2, Runs 368, 368_1, 368_2, 368_3 10Be runs ScalersRun368At20h30.pngTAC_Run368_At21h.pngScalersRun368at21h52.png
RUNS 368, 368_1, 368_2
I ~ 3.7 eµA (on D6 TI22)
General DAQ 1Go during 1h30 
Fixed, e748, Fri Jul 7 22:02:39 2017, e748 shift U Simon G +Valérie L, CATS, General, CD2, CATS situation StrQRawCats_Run368At22h.pngPosCats_Run368At22h.png
During Run 368, we note at 21h30 that now CATS2 has continuously a 0.1 µA current. Maybe there are some microtrips on some central part of the detector.
The counter also shows strong fluctuations of CATS2 counting rate between 80 and 40kcps down to 0 then up again.
Concerning the raw charges on CATS, the situation is similar since the beginning of the runs in the afternoon, 7th July.
Fixed, e748, Fri Jul 7 22:36:12 2017, e748 shift U Simon G +Valérie L, BEAM, General, CD2, Beam during Run368, situation at 22h30 ScalersRun368_At22h35.pngP2280831ecranTIat22h40.JPG
After strong instabilities the beam intensity is better and we have recovered nearly 93kcps on CATS2 as during the beginning
of run 368 at 16h30. Cf scalers below at 22h35, and the picture of the primary beam intensity. 
Fixed, e748, Fri Jul 7 23:45:52 2017, e748 shift U Simon G +Valérie L (-12 am)/ Daisuke+Shumpei+Marlene (12 am -), RUN, General, CD2, Run 368 (following) at 23h45 6x
At 23h45; Beam stable I  3.95 µA
CATS2 ~ 94 kcps (2 pictures of CATS at 4 hours difference attached)
chio 89kcps Plastics 87kcps FAG ~ 180-190/s 
Fixed, e748, Sat Jul 8 06:02:18 2017, e748 Marlène Daisuke Shumpei, RUN, General, CD2, RUN369 scalers_e369.png
Caviar has tripped during the night (before 4a.m.)
We have put the bias again but we could not reach the nominal value of 1040V. We have set the bias at 950V.
If we increase the bias, then the current rises strongly and reaches the 2uA limit.
Fixed, e748, Sat Jul 8 08:39:10 2017, Daisuke, Shumpei, OFFLINE, General, CD2, 12Be(d,t)? 2017-07-08_run331_12be_dt_likely.png2017_07_08_gate.png2017_07_08_chio_gate.png
/home/e748/analysis/nptool/Outputs/Analysis/runtest.root (run_0331_0.root?) was analyzed.
DSSD energy vs theta_lab plot for triton is attatched.
The gates to select triton are also shown.
Fixed, e748, Sat Jul 8 08:39:37 2017, Shumpei, Daisuke, OFFLINE, General, CD2, 12Be(d,t)? 2017-07-08_run331_12be_dt_likely.png2017_07_08_gate.png2017_07_08_chio_gate.png
/home/e748/analysis/nptool/Outputs/Analysis/runtest.root (run_0331_0.root?) was analyzed.
DSSD energy vs theta_lab plot for triton is attatched.
The gates to select triton are also shown.
Fixed, e748, Sat Jul 8 09:00:32 2017, e748 Anastasia, D. , RUN, General, N/A, error msg on run control (run 369) Capture-error-msg-run369.png
[IMG]elog:274/1[/IMG]
Fixed, e748, Sat Jul 8 09:19:37 2017, e748 Anastasia, D. , RUN, General, N/A, CATS raw 2D charge during run 369 Capture-catsraw-run369.png
[IMG]elog:275/1[/IMG]
Fixed, e748, Sat Jul 8 09:43:17 2017, e748 Anastasia, D. , RUN, General, N/A, DAQ Parameters: Caviar new run 370 
Threshold of CAVIAR_DDM changed from ~ -800 to ~ -510
run 370 Triggering only in Cats to check CAVIARs new thresholds
Fixed, e748, Sat Jul 8 11:42:43 2017, e748 Anastasia, D. , RUN, General, N/A, new Run 371 Caviar_DDM4_thresholds.pngCaviar_DDM3_thresholds.png
Triggers MUST2 and CATS as before, 
-rw-r--r-- 1 e748 Exxx   16M  8 juil. 11:43 run_0371.dat.08-07-17_11h41m39s
Fixed, e748, Sat Jul 8 12:53:09 2017, e748 Anastasia, D. , RUN, General, N/A, RUN 371 caviar_par.pngcaviar_par2.png
Changing Caviar thresholds during the run to find the optimum efficiency 
More specific The DDM16_4 the channels 4 and 5 *
Fixed, e748, Sat Jul 8 14:00:06 2017, e748 Anastasia, D. , RUN, General, CD2, Run 372 DDM16_3.pngDDM_4.pngDDM16_5.png

Start new run with final CAVIAR threshold settings 
HV slightly increased to 980V
Fixed, e748, Sat Jul 8 16:39:00 2017, e748, RUN, General, CD2, Stop run 372 - CHIO digitizer lost parameters 
 
Fixed, e748, Sat Jul 8 16:41:57 2017, e748, RUN, General, CD2, Run 373 scalers_run373.pngCATS_raw_run373.pngCATS_run373.png
Restart after rewriting parameters onto CHIO digitizer
Same conditions as previous run
Fixed, e748, Sat Jul 8 17:04:25 2017, e748, RUN, General, CD2, RUN 374 scalers_run374.png
We stopped run 373 to check the MUVI scalers on the DAS.
We wrote the parameters onto the CHIO digitizer and restarted -> Run 374
Same conditions as before.
Fixed, e748, Sat Jul 8 19:41:25 2017, e748, RUN, General, CD2, Run 374 (file change) scalers_run374_2.pngCATS_run374_2.pngCATS_raw_run374_2.png
19:29 data file change -> run_0374.dat.08-07-17_16h57m56s.2
Previous change : 18:11 -> run_0374.dat.08-07-17_16h57m56s.1
Fixed, e748, Sat Jul 8 20:49:48 2017, e748, BEAM, General, CD2, Beam position on target TargetPos_run374_20h48.png
The beam spot on target has shifted upwards by ~3 mm since beginning of 10Be run (see run 366 and attached plot from run 374, July 8 20:48).
Fixed, e748, Sat Jul 8 21:04:07 2017, e748, BEAM, General, CD2, Update: beam position on target TargetPos_run374_afterDC41VE.png
At ~21:00 we called PCP: They adjusted the DC41VE steerer to center vertically the beam on our target.
See attached plot.
Fixed, e748, Sat Jul 8 21:53:58 2017, e748, BEAM, General, CD2, Scalers run 374 scalers_run374_21h49.png
Counting rates keep decreasing though the primary is still ~4.5 uAe and the beam is centered on our target.
We called François de Oliveira who helped us to print the parameters of the line. We go to the PCP with the print.
Fixed, e748, Sat Jul 8 23:22:18 2017, e748, BEAM, General, CD2, Update on counting rates + scalers scalers_run374_23h21.png
18O 4.5 uAe
CATS1 91 kcps
CATS2 114 kcps
Fixed, e748, Sat Jul 8 23:51:06 2017, e748 shift U Valérie L. , RUN, General, CD2, Overview of run 374 around midnight 7x

Run at 23h48 with stable conditions, 18O beam: 4.5 µA
 
Fixed, e748, Sun Jul 9 02:41:49 2017, e748- shift U:Valérie L +Beyhan B., RUN, General, CD2, Run 374 - good beam conditions  10x
The 18O was very stable between 0h and 2h around I ~ 4.5 µA. 
CAVIAR ~ 161k; CATS1 ~ 88kcps;  CATS2~ 111kcps ; CHIO ~ 106kcps; PLASTIC ~ 105 kcps.
The dead time is between 4 and 7%.
Fixed, e748, Sun Jul 9 04:21:42 2017, e748- Beyhan B + Valérie L, BEAM, General, CD2, BEAM SURVEY AT PCP GraphicBeame748july17.jpg
The beam Survey from the PCP can be seen in the attached picture below.
Our spokesperson Adrien M can go and ask to the PCP at the end of the experiment the data file of the beam intensity histograms.
The plots can be seen in the intranet [The address is: http://intranet.ganil.fr/SDA/suivi_equipements/ ]
Fixed, e748, Sun Jul 9 04:43:40 2017, e748 shift U Valérie L. +Beyhan B., RUN, General, CD2, Run 374- 9 JULY - stop at 5h ScalersRun374At4h46.pngRun374CatsRawStrQ_4h40.png
Between 4h-4h50 the 18O has decreased from 4.5 down to 4 µA.
CAVIAR ~ 161k; CATS1 ~ 90kcps; CATS2~ 114kcps ; CHIO ~ 109kcps; PLASTIC ~ 108 kcps.
The dead time is between 4 and 7%.
Fixed, e748, Sun Jul 9 05:21:29 2017, e748 shift U Valérie L. +Beyhan B.(-8h)/ Daisuke Shumpei (8h-), RUN, General, CD2, Run 375 after beam stop 11x
The tuning of the beam alignment was checked by the PCP. cf beam profiles at 5h15 in LISE notebook and below.
We check also the beam profiles on CATS.
The beam was at 4.2 µA increasing to 4.6 µA but we do not recover the same intensity in LISE as during the run 374.
Fixed, e748, Sun Jul 9 09:07:31 2017, Jean-Charles Valérie L. Daisuke Shumpei, RUN, General, CD2, Run 376 LISE tuning (underway) run376_must2.pngrun376_cats.png
RUN 376 short run to check beam profile during LISE tuning.

9h07 started
Fixed, e748, Sun Jul 9 09:13:54 2017, Jean-Charles Valérie L. Daisuke Shumpei, RUN, General, CD2, Run 377 LISE tuning (underway) run377_cats_final.pngrun377_must2_final.pngrun377_echelles_final.png
RUN 376. LISE tuning to optimize the beam spot on target. During this run, the beam stop will be moved. 

9h12 started
Fixed, e748, Sun Jul 9 09:36:42 2017, Daisuke Shumpei Valérie L. (-9h50) Jean-Charles (-10h), RUN, General, CD2, Run 378 10x
Data accumulation after LISE tuning. 

9h36 started. 
Fixed, e748, Sun Jul 9 09:43:29 2017, Daisuke Shumpei Jean-Charles, OTHER, Hardware, CD2, Printer Magnolia is out of cartridge.. 
Use "iris-color". The printer is in the room ACS17 (found left in the corridor from the LISE counting room to the building exit).
Fixed, e748, Sun Jul 9 10:27:09 2017, Shumpei, Daisuke, OFFLINE, General, CD2, 12Be(d,t) E_Theta_dt2.pdfE_Theta_dt3.pdf
More statistics for (d,t) channel.
Same gate as before () but MM1&MM4 are used.
Fixed, e748, Sun Jul 9 10:29:20 2017, Shumpei, Daisuke, OFFLINE, General, CD2, 12Be(d,t) E_Theta_dt2.pdfE_Theta_dt3.pdf
More statistics for (d,t) channel.
Same gate as before (Message ID: 273     Entry time: Sat Jul 8 08:39:37 2017) but MM1&MM4 are used.
Figures are with 12Be(d,t) kinematics for all events and (events per bin)>6.
    Fixed, e748, Sun Jul 9 11:56:31 2017, Shumpei, Daisuke, OFFLINE, General, CD2, 12Be(d,t) 
[quote="Shumpei, Daisuke"]More statistics for (d,t) channel.
Same gate as before (Message ID: 273     Entry time: Sat Jul 8 08:39:37 2017) but MM1&MM4 are used.
Figures are with 12Be(d,t) kinematics for all events and (events per bin)>6.
Fixed, e748, Sun Jul 9 13:42:26 2017, Shumpei, Daisuke, OFFLINE, General, CD2, 10Be(d,t) & 10Be(d,3He)? dE_E_CHIO_pla.pdfE_Theta_dt_10Be2.pdfE_Theta_dt_10Be3.pdf
Same analysis for (d,t) channel but 10 Be beam. run368-374.4 (-1 day data)
Separation for Z=3&4 with CHIO(analog) + plastic is difficult so Z=4 gate may include Z=3&4.
Figures are with 10Be(d,t)9Be and 10Be(d,3He)9Li kinematics for all events and (events per bin)>4.
Fixed, e748, Sun Jul 9 16:37:21 2017, e748, CHIO, General, CD2, CHIO digitizer out 
CHIO digitizer was out in run 378
Fixed, e748, Sun Jul 9 16:43:40 2017, e748, OFFLINE, General, CD2, Elastic scattering MM6&7 12Be_elastic.pdf
Telescope 6&7 are analyzed for 12Be beam.
The energy of Si vs angle plot for each telescope (CsI veto and beam position gate) are shown.
The red lines are kinematics for 12Be(d,d) and (p,p).
Fixed, e748, Sun Jul 9 16:44:58 2017, Shumpei, Daisuke, OFFLINE, General, CD2, Elastic scattering MM6&7 12Be_elastic.pdf
Telescope 6&7 are analyzed for 12Be beam.
The energy of Si vs angle plot for each telescope (CsI veto and beam position gate on target) is shown.
For MM6 (left), a locus for punch-through is seen maybe because CsI veto gate is not so good.
Fixed, e748, Sun Jul 9 18:44:38 2017, e748, BEAM, General, CD2, LOST BEAM around 18h30 
Vaccuum was lost after CSS2, so we lost the primary beam (18:30)
Operators called the astreinte.
Fixed, e748, Sun Jul 9 20:38:11 2017, e748, BEAM, General, CD2, LOST BEAM around 18h30 
Seems there is a water leak in the beam line near alpha. 
Astreinte is at work. 
Fixed, e748, Sun Jul 9 23:57:34 2017, e748, BEAM, General, CD2, NUMBER FOR PCP 
There is a major shutdown of the GANIL phone system. 
You can not call the pcp via the usual extention; instead call : 02 31 43 59 77
(the phone number is on a paper next to the LISE pupitre phone)
Fixed, e748, Mon Jul 10 00:23:41 2017, e748, RUN, General, CD2, Return of the beam (Jedi not available) CATS.png
Beam is back.
JCT refoc the beam on target (attached pictures).
All god beside that. Still no phone on campus!
Fixed, e748, Mon Jul 10 00:35:29 2017, e748, RUN, General, CD2, Run 380 scalers_run380.png
Started at 0:02

18O 4.3 uAe, fluctuating
Fixed, e748, Mon Jul 10 01:34:12 2017, e748, RUN, General, CD2, Run 380 (file change) scalers_run380_1.png
Data file change at 1:18 -> run_0380.dat.10-07-17_00h02m00s.1

18O 4.5 uAe
Fixed, e748, Mon Jul 10 02:04:33 2017, e748, CATS, General, CD2, CATS raw strips and trajectories CATS_raw_run380_1.pngCATS_run380_1.png
 
Fixed, e748, Mon Jul 10 02:47:27 2017, e748, RUN, General, CD2, Run 380 (file change) Scalers_run_380_2.png
2:26 data file change -> run_0380.dat.10-07-17_00h02m00s.2

18O 4.5 uAe
Fixed, e748, Mon Jul 10 03:34:24 2017, e748, RUN, General, CD2, Run 380 (file change) scalers_run380_3.png
3:33 data file change -> run_0380.dat.10-07-17_00h02m00s.3

18O 4.5 uAe
Fixed, e748, Mon Jul 10 03:45:19 2017, e748, MUST2, General, CD2, SiLi 1/T5 triped 
Triped between 3:34 and 3:44.

We turn it back on at 3:46 (370 V) -> 22.5 uA
Fixed, e748, Mon Jul 10 04:33:32 2017, e748, CATS, General, CD2, CATS: raw strips, trajectories and pos on target CATS_raw_run_380_3_4h35.pngCATS_run380_3_4h35.pngtarget_pos_run380_3.png
 
Fixed, e748, Mon Jul 10 04:46:11 2017, e748, RUN, General, CD2, Run 380 (file change) scalers_run380_4.png
4:42 data file change -> run_0380.dat.10-07-17_00h02m00s.4

18O 4.4 uAe
Fixed, e748, Mon Jul 10 05:47:40 2017, e748, RUN, General, CD2, Run 380 (file change) scalers_run380_5.png
5:46 data file change -> run_0380.dat.10-07-17_00h02m00s.5

18O 4.5 uAe
Fixed, e748, Mon Jul 10 06:53:40 2017, e748, MUST2, General, CD2, SiLi 1/T5 triped 
Triped at ~ 6:50.
We turn it back on at 370 V -> I = 18 uA but increases rapidly to 21 uA
Fixed, e748, Mon Jul 10 06:55:58 2017, e748, RUN, General, CD2, Run 380 (file change) scalers_run380_6.png
6:48 data file change -> run_0380.dat.10-07-17_00h02m00s.6

18O 4.5 uAe
Fixed, e748, Mon Jul 10 08:19:45 2017, e748, RUN, General, CD2, End run 380 
We stop run 380 to enter D6 and select mask target for CATS reference data.
Fixed, e748, Mon Jul 10 08:37:23 2017, e748, RUN, General, N/A, Run 381 mask target 
Trigger = Plastic, div=1
Primary intensity = 1 uAe
CATS rate = 35 kcps
Fixed, e748, Mon Jul 10 10:06:27 2017, e748, RUN, General, N/A, end of experiment 
10h06 we stop the experiment.
Fixed, e748, Mon Jul 10 17:43:37 2017, Adrien, MUST2, General, N/A, Calimero time calibrator 
Run 1000 : MUVI 1 X

Time calibrator 20ns period, 512ns range
Fixed, e748, Thu Jul 20 11:07:54 2017, e748, CATS, General, N/A, Run 1035 calib cats1 
After experiment CATS 1 pulser calibration
Pulser Quality: very bad - to be analyzed with care
Calibration almost unchanged
Fixed, e748, Thu Jul 20 11:09:34 2017, e748, CATS, General, N/A, Run 1036 calib cats 2 Y 
After experiment pulser calibration CATS 2 (Y)
1st amplitude slightly saturates CATS 2 X.
Use for CATS 2 Y recalibration
Pinned, e744, Thu Mar 15 10:50:00 2018, Adrien Matta, MUST2, Hardware, , Distribution box LPC 8x
Cabling file by Fabien Naury (LPC).
Pinned, e744, Mon Mar 26 11:44:27 2018, e744 : Valerian, OTHER, General, , Current Elog state 
Currently we do not have access to the experiment number. To write an entry for e744 the nickname TEST will be used.
Fixed, e744, Mon Mar 26 11:46:43 2018, e744 : Valerian, RUN, General, 3-alpha, Tests runs Ganacq log 
(15:51:33 - 19/03/2018) INFO - rcc_gui - Started run #1

(16:22:01 - 19/03/2018) INFO - rcc_gui - Stopped run #1
Fixed, e744, Mon Mar 26 14:20:22 2018, e744 : Valerian, MUST2, Hardware, 3-alpha, Bidimensional graphs for Telescope 7 and 6 T6_3alpha.pdfT7_3alpha.pdf
WARNING T5 == T7
[U][B]
EDIT 27/03/18 : WARNING X and Y are inverted, this entry should be ignored see entry : [URL=https://elog.lpc-caen.in2p3.fr/MUST2/333]Bidim for T1 T3 T4
Ongoing, e744, Mon Mar 26 15:07:06 2018, e744 : Valerian et Louis, MUST2, Hardware, 3-alpha, Energy vs Strip for T6 et T7 StripXE_vs_StripNbr_T6.pdfStripXE_vs_StripNbr_T6_zoom.pdfStripYE_vs_StripNbr_T6.pdf
Weird signal on StripX of T6... might be the copper oxyde projections making a short-circuit

[U][B]EDIT 27/03/18 : The problem seen on Telescope 6 might be due to either some Asics Problem, or due to some dirt, the current reason in not known currently.
Ongoing, TEST, Tue Mar 27 10:47:39 2018, e744 : Valerian, MUST2, Hardware, 3-alpha, Choice of DSSSDs 
 
Ongoing, e744, Tue Mar 27 11:11:04 2018, e744 : Valerian, MUST2, Hardware, 3-alpha, Choice of DSSSDs 14x
Different plots of Strip channel vs Strip number for X and Y in order to make our choice
Fixed, e744, Tue Mar 27 16:26:29 2018, e744 : Valerian, MUST2, General, 3-alpha, Bidim for T1 T3 T4 T5 T6 T7 T8 7x
 
Ongoing, e744, Tue Mar 27 17:22:24 2018, e744 : Valerian, MUST2, Hardware, 3-alpha, Choosing the DSSSDs 
We can see that the DSSSDs on T1(CsI) T3(CsI) T4(CsI) and T5(SiLi) are in good shape (cf :[URL=https://elog.lpc-caen.in2p3.fr/MUST2/333]Bidim for T1 T3
T4 T5 T6 T7 T8 [/URL]).
    Ongoing, e744, Wed Mar 28 13:21:32 2018, e744 : Valerian, MUST2, Hardware, 3-alpha, Choosing the DSSSDs 
[quote="e744 : Valerian"]We can see that the DSSSDs on T1(CsI) T3(CsI) T4(CsI) and T5(SiLi) are in good shape (cf :[URL=https://elog.lpc-caen.in2p3.fr/MUST2/333]Bidim
for T1 T3 T4 T5 T6 T7 T8 [/URL]).
       Ongoing, e744, Wed Mar 28 16:35:01 2018, e744 : Valerian, MUST2, Hardware, 3-alpha, Choosing the DSSSDs TimeMust2X_MUVI2_uncalib.pngTimeMust2Y_MUVI2_uncalib.pngSpectresMUVI2stripXT300ns.png
[quote="e744 : Valerian"][quote="e744 : Valerian"]We can see that the DSSSDs on T1(CsI) T3(CsI) T4(CsI) and T5(SiLi) are in good shape (cf :[URL=https://elog.lpc-caen.in2p3.fr/MUST2/333]Bidim
for T1 T3 T4 T5 T6 T7 T8 [/URL]).
Fixed, e744, Tue Apr 3 10:44:38 2018, e744 : Valérian, MUST2, Hardware, , Update on Must2 telescopes 20180403_103732.jpg
For the next day, the plan is to check the DSSD's connections of T6 & T7 followed by an alpha run, if the problem seen on T6 are not resolved, we will change
the DSSD of T6 and re-do another alpha run, the last option would be to change the Muffee card.
Ongoing, e744, Tue Apr 3 15:30:49 2018, e744 : Valérian, MUST2, Hardware, , Cabling of T6 & T7 Inversion_between_telescopes.pdf
After checking the cable of T6 & T7 it seems that there were in fact an inversion during experiment e748. T6 is the bottom one, and T7 the top one. 

During e748, it seems that there were some difference regarding the position, between the hardware and software position...
Ongoing, e744, Wed Apr 4 17:49:05 2018, e744 : Valérian, EXL-PPT, Hardware, , Update on EXL 6x
The EXL detector has been mounted, it is very close to the target ~4cm and doesn't do any shadow on the M2 telescopes. But it isn't at 90° anymore. The
cable have been plugged-in (cf photos). With a new mapping of the detector (cf drawing).
Fixed, e744, Tue Apr 10 17:43:28 2018, Adrien Matta and FyFy, MUST2, Hardware, N/A, login to CAEN SY1527 HV/BT mainframe 
To control the CAEN SY1527 HV/BT mainframe use the following command from a terminal:

telnet 172.16.139.10 1527
Fixed, e744, Tue Apr 17 09:07:55 2018, Adrien Matta, DAQ, General, N/A, DAQ issue summary 
Previously on e744:

After a chat with Charles Houarner we decided to have configuration with a Muvi card per VXI crate. This is supposed to reduce the dead time (DT) by parallelising
Fixed, e744, Tue Apr 17 09:18:00 2018, Cherry MX team, MUST2, Hardware, N/A, T5 is back and running strong T5.pdf
T5 telescope appears to be fully functional again. It shows both Energy and Time with excellent resolution.
Ongoing, e744, Tue Apr 17 17:36:37 2018, Cherry Mx Team, MUST2, Software, N/A, GRU SUCKS 
Pretty much today's summary in the title.

[URL=https://i.pinimg.com/originals/a8/d4/12/a8d41206e8bd9c189397fb4907656981.jpg]https://i.pinimg.com/originals/a8/d4/12/a8d41206e8bd9c189397fb4907656981.jpg[/URL]
Fixed, e744, Mon Apr 23 11:33:53 2018, e744 Valerian, OTHER, Hardware, N/A, Inspection signals 
Inspection signals between D6 and LISE Acquisition room are connected as follow : 

178: FAG
Pending, e744, Tue Apr 24 14:18:22 2018, Valerian Freddy and Adrien aka Cherry Mx Team, MUST2, Hardware, N/A, Current telescope-pcb layout 
Telescope 1 : PCB 5 (ref on pcb: 2274)
Telescope 2 : PCB 4
Telescope 3 : PCB 7
Fixed, e744, Tue Apr 24 15:42:03 2018, e744 Valérie L., DAQ, General, , GMT chronogramme GMTmasterChrono24avril18.pngGMTslaveChrono24avril18.png
Crate ganlx1 GMT master FAG 100ns ; VAL 2 µs ; CT 6 µs
Crate ganlx14 GMT slave FAG 100ns ; VAL 2 µs ; CT 3 µs
Fixed, e744, Tue Apr 24 15:51:04 2018, e744 Valérie L., MUST2, General, , MUST2 configuration /parameters ConfigMuviPhysMust2Thr.png

TAC range for all telescopes: 600ns
Thresholds: 402 keV
Fixed, e744, Tue Apr 24 16:22:08 2018, e744 Valérie L., RUN, Software, , Narval Merger Parameters ConfigRunControlNArvalMerger.png
 
Fixed, e744, Wed Apr 25 15:59:51 2018, Valérian, EXL-PPT, Software, N/A, Mesytech setup 
To use the remote settings of the Mesytech modules : 
[CODE]
- start GANP170
Fixed, e744, Wed Apr 25 20:47:59 2018, e744 Valérie, MUST2, General, , MUST2 mate Temperature on the DAS interface ConfigDASMuvi1Tel4mufeeX.pngConfigDASMuvi1Tel5mufeeXokTemp.png
tests
The plot:ConfigDASMuvi1Tel4mufeeX.png shows the situation on the Mufee card when the cooling system was blocked (ice in the tube! there was water inside
instead of alcohol) on Wednesday 25th. cf there was 47°C on MufeeX mate of Telescope 4.
Ongoing, e744, Thu Apr 26 19:37:24 2018, Valerian and Freddy, MUST2, Hardware, N/A, Debug of Must2 telescopes debug_mm_telescopes.pdfProblem_on_T5_T6_cable_swap.pdf
Today we found different problems, no time on T4 and no signal on T5 and T6 CsI tripping. After changing cables and a lot of tests with the chamber open
and only the BT ON, T4 and T5 problems seemed to be fixed. 
Ongoing, e744, Sat Apr 28 10:17:22 2018, Valerian and Iulian, MUST2, Hardware, 3-alpha, Status of MUST2 telescopes 27/04/18 Third_good_run_Energy_and_time_for_5_Must2_detectors_2018-04-27_19-32-23.png
Yesterday night we tested T1, T2, T3, T4, T5, and T6.

All telescopes (except T6 which still have a "tripping" CsI) have an Energy and Time signal on X and Y!
Ongoing, e744, Sat Apr 28 13:27:26 2018, Valerian and Iulian, MUST2, Hardware, 3-alpha, multiples runs with two alpha source on T1 T2 T3 T4 and T5 
For the following runs we will use two 3 alpha sources :

On T1, T2, T3, and T4 : [B]11615[/B] : Flux = 1496 alpha in 2 pi
Ongoing, e744, Sat Apr 28 13:36:52 2018, Valerian and Iulian, OTHER, Software, N/A, Problem with DAS configuration 
There is an issue with the GMT slave. When you click Online and then apply write hardware, if the message : [U]register error on GMTSlave[/U] appear, [B]reload
a functioning DAS config[/B] and [B]do not write hardware twice[/B]. 
Pending, , Sat Apr 28 21:12:55 2018, iulian, MUST2, General, 3-alpha, Run 182 end ; problem with cooling end_result_alpha_source_28_April.png
RUN 182 start @13h
Stoped @ 21H
Fixed, e744, Sun Apr 29 20:37:58 2018, Francois, CATS, General, , Chronogram chrono.jpg
 
Fixed, e744, Mon Apr 30 20:38:21 2018, iulian, RUN, General, 3-alpha, 6run 186 3a source 60 co source 
[U][B]run #186[/B][/U] 

start@11h 30/04
Fixed, e744, Mon Apr 30 20:42:34 2018, iulian, RUN, General, 60Co, run 188 60 co source 
[U][B]run #188[/B][/U] [I]60co source EXL+PPT trigger[/I]

Started  @20h42 30/04
Fixed, e744, Tue May 1 10:47:41 2018, iulian & valerian, RUN, General, 60Co, run 189 60 Co source 
[U][B]run #189[/B][/U] [I]60co source EXL+PPT trigger[/I]
Changed the way of codding PPT. for this run ppt is coded with the QDC using first dynode.
Started  @10h48 01/05
Fixed, e744, Wed May 2 18:11:59 2018, Iulian Marlenne Louis, RUN, General, 3-alpha, 3 alpha test run_191.png
Run191 start 18h stop 18h10 
Run ok, saved config DAS with good polarity on the thresholds CSI & piedestal allignement on MM1-MM5
Ongoing, e744, Thu May 3 08:50:17 2018, François, VACUUM, General, , stop vacuum 
turbo pumps stopped at 8H45

problem with the cooling system of the M2C chamber, the liquid was in the pipe but it was stopped, no flow, with a lot of "dusts" (vert de gris) => decision
Fixed, e744, Thu May 3 15:04:03 2018, Iulian Marlenne, MUST2, Hardware, N/A, X and Y possitions on the detector 
Telescope 1 : PCB 5 (ref on pcb: 2274)
Telescope 2 : PCB 4
Telescope 3 : PCB 7
Fixed, e744, Thu May 3 15:20:16 2018, Iulian Marlenne, MUST2, Hardware, N/A, X and Y possitions on the detector 
Telescope 1 : PCB 5 (ref on pcb: 2274)
Telescope 2 : PCB 4
Telescope 3 : PCB 7
Ongoing, e744, Thu May 3 19:11:14 2018, Valerian Marlene and Francois, MUST2, General, 3-alpha, run 3 alpha T5 
[U][B]run #196[/B][/U]
3 alpha source and pedestals supressed
Trigger T5 only
Fixed, e744, Fri May 4 11:20:50 2018, Valerian, MUST2, General, 3-alpha, T5 : 0° telescope  StripX_vs_StripY_T5_100V.pdfSi_E_T5_100V.pdf
After increasing the voltage on T5 DSSD from 80V to 100V the resolution increased from ~40keV sigma to 20keV sigma.

StripX vs StripY bidim and the 3 alpha peaks are joined to this entry.
Fixed, e744, Fri May 4 23:58:07 2018, iulian, RUN, General, 3-alpha, Run #203 alfa source & 60co source run_203_ht.pngrun_203_ppt.pngrun_203_EXL.pngrun_203_must2.png
[U][B]run #203[/B][/U]

alpha source & 60co source
Ongoing, e744, Sat May 5 11:14:33 2018, Iulian & Valerian, RUN, General, 3-alpha, run #204 alpha source BT_tripped_T5.pngT5_das_no_cooling.pngT5_das_no_cooling2.pngT5_vigru_no_cooling.png20180506_152338.jpg
[U][B]run #204[/B][/U]
alpha source
start @11h15 05/05
Fixed, e744, Sun May 6 17:52:21 2018, Valerian, RUN, General, 3-alpha, Run #205 T1 T2 T3 & T4 
[U][B]run #205[/B][/U]
T1 T2 T3 & T4 T5 still in trigger but no HT/BT
start @15h43
Ongoing, e744, Sun May 6 17:55:05 2018, Valerian, OTHER, General, 3-alpha, Update on the cooling system problem 6x
After waiting for 1-2 hours. I started the BT again on T5 no tripping BT anymore. While writing hardware with DAS T5 responded well.

After starting the HT, i started a new run :
Fixed, e744, Mon May 7 10:42:58 2018, Valerian, OTHER, General, 60Co, Update on the cooling system and run gamma (signal problem on PPT) HT_EXL.pngEXL_spectra_run207.pngPPT_spectra_run207.pngEXL_spectra_run209.png
Today, both cooling system are working fine and their levels are OK.
The vacuum are 7e-6 mbar in M2C and 2e-5 in the 0 degree chamber.
Fixed, e744, Thu May 10 15:06:44 2018, iulian & valerian, EXL-PPT, General, 60Co, Started run #211 & #212 #213 60Co source efficiency run PPT_spectra_run213.pngEXL_spectra_run213.png
[U][B]Run #211[/B][/U] BAD Run no BT
60Co source efficiency run EXL & PPT trigger. Gains and thresholds set
start @15h05 10/05
Fixed, e744, Thu May 10 14:38:41 2018, iulian, EXL-PPT, Hardware, N/A, Mesytech settings 
Tried unsuccessfully to change the gain on EXL energies.
Looking at the inspection lines noticed that all the EXL signals were inverted (negative) and we were coding only the pole zero part of the signals.  
 
    Pinned, e744, Fri May 11 14:00:48 2018, iulian, EXL-PPT, Hardware, N/A, Mesytech settings 20180511_132034_1526038557770.jpg
[quote="iulian"]Tried unsuccessfully to change the gain on EXL energies.
Looking at the inspection lines noticed that all the EXL signals were inverted (negative) and we were coding only the pole zero part of the signals.  
 
Fixed, e744, Sat May 12 08:54:42 2018, iulian, MUST2, General, 3-alpha, Run #114 T1-T5 trigger 3alpha source calib run  Must_spectra_start_run214.pngMust_spectra_stop_run214.png
[U][B]Run  #214[/B][/U]
Trigger T1-T5 & gamma 
3 alpha run 
Ongoing, e744, Sat May 12 20:09:09 2018, iulian, MUST2, General, 3-alpha, Run #115 3 alfa run Calibration T1-T5 trigger Must_spectra_start_run215.pngMust_spectra_stop_run215.pngerror_run215.pngerror_1minlater_run215.png
[U][B]Run #215[/B][/U]
Trigger T1-T5 
3 alpha run
Ongoing, e744, Sun May 13 12:09:55 2018, iulian, MUST2, General, 3-alpha, Run #116 3 alfa run Calibration T1-T5 trigger  Must_spectra_start_run216.png
[U][B]Run #115[/B][/U] 
3 alfa run Calibration T1-T5 trigger 
start 12h10
Pending, e744, Sun May 13 13:32:44 2018, iulian, ONLINE, Software, N/A, start_online ilegal instruction fault 
From time to time the start_online code gives an ilegal instruction error and crash... Once the ctrl-c pressed it shows:

Ongoing, e744, Sun May 13 19:36:09 2018, Valérian + François, MUST2, General, 3-alpha, Run #116 #117 3 alpha run Calibration T1-T5 trigger MUST2_HT_BT_13-05-2018.pngspectra_14-05-2018.png
[U][B]run #116[/B][/U]
start @12h07 13/05/18
stop  @19h45 13/05/18
Fixed, e748, Mon May 14 10:49:47 2018, François, DAQ, Software, , TDC problem 
Problem :
TDC labels are 0. After the compilation of action list the labels seem to appear (if I remember correctly), but after a save/reload of the config they
are gone, and in all cases no event coded (on the oscilloscope a validation point is visible, but do not know what this means in the case of a TDC – even
Ongoing, e744, Mon May 14 12:57:44 2018, Francois, TARGET, General, , target preparation 


Cibles Georges
Fixed, e744, Mon May 14 13:52:25 2018, François, BEAM, General, , Profileur Sans_titre.jpg


Ongoing, e744, Tue May 15 09:58:52 2018, Valérian, RUN, General, 3-alpha, run #118 3 alpha 
[U][B]run #118[/B][/U]
Trigger T1 T2 T3 T4 & T5 
EXL + BT not biased but still in trigger
Fixed, e744, Tue May 15 19:42:40 2018, Valérian, EXL-PPT, General, 60Co, Calibration of EXL from e748 data EXL_Sum_e748_Calib.png
The EXL calibration program is ready. Join is the result with previous data from e748.
Ongoing, e744, Tue May 15 21:32:46 2018, Iulian Valerian, EXL-PPT, General, 60Co, run #300 60 Co source EXL & PPT trigger 
[U][B]Run #300[/B][/U]
PPT EXL trigger 60Co
Ongoing, e744, Wed May 16 09:49:26 2018, Francois & Ruxandra & Armel, BEAM, Hardware, , E1D6 and E2D6 detectors essai.jpg
After struggling with the noise, we achieved ~  50 keV resolution.

Source = 1 alpha peak  241Am   E=5.485 MeV
Fixed, e744, Wed May 16 11:30:21 2018, iulian, EXL-PPT, General, 60Co, run 302 60Co source 
[U][B]Run #302[/B][/U]

60 Co source PPT & EXL trigger
Fixed, e744, Wed May 16 16:27:29 2018, e744, lama, beyhan, OTHER, Hardware, , TACS from LISE to the exp DAQ 
The following TACs signals from LISE have been cabled and send to the experimental acquisition (->D6)

TED4_HF  (cable physically labeled 29 of the ADC)
Fixed, e744, Wed May 16 17:03:18 2018, Ruxandra, EXL-PPT, Software, , calibration 
Calibration coefficients for the PPT detector using the 60Co and 40K lines: E=0.5514*ch - 83.322. Internal radioactivity at 1444 keV, not separated from
40K
Efficiency: During the run (21h46min40s) the number of gammas emitted from the 60Co source is 66796800; for the Co pics the integrals are: 2.71e05 for
Fixed, e744, Wed May 16 17:14:20 2018, e744, lama, beyhan, OTHER, Hardware, , setting of signals from LISE to exp. DAQ 
We put the following signals from LISE on DAQ :

(counting channels from 1)
Fixed, e744, Wed May 16 18:01:47 2018, Iulian Valerian, MUST2, Software, N/A, First successful Calimero run on T1 voie X run 316  Calimerro_run316.png
First successful Calimero run on T1 voie X run 316 
Fixed, e744, Wed May 16 19:06:39 2018, Iulian Valerian, MUST2, Software, N/A, run #318 Calimero T1-T4 strips X Calimerro_run318.pngCalimerro_T4_X_strip2_run319.pngCalimerro_T2_X_strip12_run319.png
[U][B]Run #318[/B][/U]

Calimero T1-T4 X
Fixed, e744, Wed May 16 20:26:48 2018, Iulian Valerian, MUST2, Software, N/A, run #319 calimero T1-T4 Y strips  Calimerro_run319.png
[U][B]run #319[/B][/U] 
calimero T1-T4 Y strips 
Fixed, e744, Wed May 16 20:36:40 2018, Iulian Valerian, MUST2, Software, N/A, run #320 Calimero T5 X Calimerro_run320.png
[U][B]run #320[/B][/U] 

Calimero T5 X
Fixed, e744, Wed May 16 20:42:43 2018, Iulian Valerian, MUST2, Software, N/A, Run #321 Calimero T5 Y strips  Calimerro_run321.png
[U][B]Run #321[/B][/U] 

Calimero T5 Y strips 
Ongoing, e744, Wed May 16 21:27:55 2018, Iulian Valerian, MUST2, Software, N/A, Run #322 Calimero T1-T4 X strips Calimerro_run322.png
Run #322 
Calimero T1-T4 X strips
 1 channel per mate not done (Valerian too slow to cable start stop ;) )
Ongoing, e744, Wed May 16 21:45:47 2018, iulian, MUST2, Software, N/A, Run #323 Calimero T1-T4 strips X Calimerro_run323.png
[U][B] Run #323[/B][/U] 
Calimero T1-T4 strips X
Ongoing, e744, Wed May 16 22:03:13 2018, iulian, EXL-PPT, Software, 60Co, run #324 60Co  EXL_run324.pngPPT_run324.png
[U][B]run #324[/B][/U] 
60Co 
Pinned, e744, Thu May 17 12:04:45 2018, iulian, EXL-PPT, Hardware, 60Co, EXL delay of ADC Codding window  Exl_timing_mesy_1_2.pdf
EXL timing delays for Mesitech module 2 & 1

Module 1 
Ongoing, e744, Thu May 17 18:29:16 2018, iulian, MUST2, General, 3-alpha, Run #333 Last alfa run before experiment Must_spectra_start_run333.png
Run #333 
3a source 
T1-T5 trigger
Ongoing, e744, Thu May 17 19:15:21 2018, Iulian , EXL-PPT, General, 60Co, Run #334 Last 60 co run for eficacity before experiment 
[U][B]Run #334[/B][/U]

start 19h15
Fixed, e744, Fri May 18 10:47:37 2018, Ruxandra, EXL-PPT, Hardware, 60Co, Co60 caliibration 
Thu  May 17 . run 339
60Co calibration
start @19h26 17/05/18
Fixed, e744, Fri May 18 13:28:24 2018, Ruxandra, EXL-PPT, Software, 60Co, new calibration 
The new calibration coefficients for the PPT detector (run 339): E=0.526*ch+32.57
Fixed, , Fri May 18 15:17:19 2018, Megumi and Louis, OTHER, Hardware, , TAC range setting and time calibration 
1 mm-cats 1us
2 mm-hf 200ns
3 mm-exl 1us
Fixed, e744, Fri May 18 17:38:21 2018, Francois and Pedja, OTHER, Hardware, , translator nim to ecl scalers.png
There was a problem with the scalers, not all of them were working. After several tests, we changed the electronic module, from Lecroy ECl-NIM-ECL to module
LPC translator NIM-ECL. We checked all channels, they work. For a while channel N°4 was not working. We changed the nim cable, it works now. 
Ongoing, e744, Sat May 19 15:32:51 2018, Iulian Valerian, EXL-PPT, General, N/A, Started run #346 Room background PPT EXL 
[U][B]run #346[/B][/U]

Room background PPT EXL
Fixed, e744, Sun May 20 18:53:44 2018, iulian Jaromir Cristina, EXL-PPT, General, N/A, Run #347 Background run EXL & PPT triggers PPT_run347.pngEXL_T_run347.pngEXL_E_run347.png
[U][B]Run #347[/B][/U]
Background run EXL & PPT triggers
start @18h53 20/05
Ongoing, e744, Sun May 20 19:11:57 2018, ruxandra cristina giuseppe jaromir, EXL-PPT, Hardware, 60Co, EXL-addback and light leak considerations EXL.pdf
in the middle of the considerations - pdf file 

Content:
Pinned, e744, Mon May 21 11:26:55 2018, iulian cristina, OTHER, Hardware, N/A, error stop run/ run still going error_Narval.pngerror_DAS1.png
After stopping run 347, the narval looks like everything was stopped (blue ready), but I still had FAGs, VALs, and the leds on the GMT were blinking. MUVI
was in ready state (leds green - red). 
Fixed, e744, Mon May 21 11:42:16 2018, iulian cristina, MUST2, Software, N/A, run 348 test comunication with Must. Pulser T1 channel 11 MUST2_Pulser_T1_E11_run348.png
 
Fixed, e744, Tue May 22 10:44:30 2018, iulian Fairouz Valerie, MUST2, Software, N/A, Run #353 Calimero T1-T4 strips X 
Started run #353
Calimero T1-T4 strips X
Time Calibrator 320 ns ; period 20 ns
Fixed, e744, Tue May 22 11:37:50 2018, Valérie, MUST2, Software, N/A, calimero config GECO PlotTel1strxT101calimOk.pngPlotXTel1tXT88Probmate.pngPlotXTel1to4XTProbmate.pngPlotXTel1to4XTcalimero.png
 
Calimero T1-T4 strips X
Time Calibrator 640 ns ; period 20 ns
Fixed, e744, Tue May 22 11:59:06 2018, Valérie, MUST2, Software, N/A, Calimero config GECO 8x
 
Fixed, e744, Tue May 22 12:09:27 2018, iulian Fairouz Valerie, MUST2, Software, N/A, Run #354 Calimero T1-T4 strips X PlotXTel1tXT88Probmate.pngPlotTel1strxT101calimOk.pngPlotXTel1to4XTProbmate.pngPlotXTel1to4XTcalimero.pngPlotXTel1to4XTcalimero.png
Started run #353
Calimero T1-T4 strips X
Time Calibrator 640 ns ; period 20 ns
Fixed, e744, Tue May 22 12:10:27 2018, iulian Fairouz Valerie, MUST2, Software, N/A, Run #355 Calimero T1-T4 strips Y 
Started run #353
Calimero T1-T4 strips Y
Time Calibrator 640 ns ; period 20 ns
Fixed, e744, Tue May 22 13:40:03 2018, Fairouz Valerie, MUST2, Software, N/A, Run #356 Calimero T1-T4 strips Y 
Run #356 
Time Calibrator Calimero stripYT T1to T4 640ns period 20ns
Pinned, e744, Tue May 22 18:33:32 2018, Nicolas, Adrien, OTHER, Software, , How to run Online and Convert raw data files 
[U][B]1. How to run Basic_online or Online code[/B][/U]
[LIST]
[*] From any computer (logged as e748 user), type '[COLOR=pink]online[/COLOR]'. This logs you to the lpcgrit server and the online directory 
Fixed, e744, Tue May 22 19:36:50 2018, Fairouz, Valérie, MUST2, Software, N/A, Run #359 Calimero T1-T4 strips X 8x
Run #359
amplitude of the gene is now set to 10 MeV
Time Calibrator Calimero stripsX  T1to T4 640ns period 20ns
Pending, e744, Tue May 22 19:40:26 2018, Francois, BEAM, General, , Planning of the experiment Chekclist_E744_4.pdf
 
Fixed, e744, Tue May 22 19:40:48 2018, Valérie , MUST2, General, N/A, snapshots for steps in Calimero calibration 11x
 
Fixed, e744, Tue May 22 20:06:15 2018, Fairouz, Valerie, edited by Iulian Megumi, MUST2, Software, N/A, Run #360 Calimero T1-T4 strips Y Calimero_GMTproblem.png
Started run #360
calimero stripsYT T1 to T4 640 ns; period 20 ns
amplitude pulser 10 MeV
Fixed, e744, Tue May 22 21:43:31 2018, iulian & megumi, MUST2, Software, N/A, run 361  T1T4_Xstrips_run361.png
[U][B]run 361[/B][/U] 
start 20h38
stop 21h41
Fixed, e744, Tue May 22 21:57:51 2018, iulian & megumi, MUST2, Software, N/A, Run #362 Calimero T1-T4 strips X again with solution Thresolds_T4_run362.pngT1T4_Xstrips_run362.png
Changed the Thresholds on T4. No longer double peaks...
I guess there is some noise on the T4 and he triggers on the noise from time to time => double peaks
Also T1-T3 have have strip 16 near pidestal who is counting a lot (red)
Fixed, e744, Tue May 22 22:33:09 2018, e744, MUST2, Software, N/A, Run #363 Calimero T1-T4 strips X again with threshold at 50% (same as 40%) T1T4_Xstrips_run363.png
[U][B]Run #363[/B][/U]
NB: Thresholds  are the ones on the pulser amplitude to inject the signal (Calimero Pulser interface on Geco). see snapshots on the Calimero summary.
Calimero with 50% thresholds on T4. Same spectra as with the thresholds @40%. I think T4 is triggering on cross-talk, so when the thresholds it's high
Fixed, e744, Tue May 22 22:50:47 2018, e744, MUST2, Software, N/A, Run #365 Calimero strips Y T1-T4 100% Threshold T1T4_Ystrips_run364.png
[U][B]Run #365[/B][/U]
Calimero strips Y T1-T4
100% threshold on T4
Pinned, e744, Tue May 22 23:42:02 2018, iulian & megumi, EXL-PPT, Software, N/A, Run #366 NARVAL FATAL ERROR error_narval_run366.png
RUN #366
EXL PPT triggers
Falat error from NARAVL
Fixed, e744, Wed May 23 00:30:34 2018, e744, EXL-PPT, General, N/A, RUN #402, EXL PPT trigger 
RUN #402
start exl ppt run for checking coincidence
exl ch 17 put in to adc2 ch 32
Fixed, e744, Wed May 23 10:52:28 2018, Valérie, EXL-PPT, General, N/A, RUN #405, EXL PPT trigger GMTtriggerRun405.pngScalersRun405.pngEXL_E1to16duringRun405.pngEXL_T1to16duringRun405.png
RUN #405
start exl ppt run for checking coincidence
 
Fixed, e744, Wed May 23 10:57:13 2018, megumi, DAQ, General, , Photo of the circuit 15x
photo of the circuit area
Fixed, e744, Wed May 23 13:15:47 2018, megumi, DAQ, General, N/A, Time calibration for TDC (EXL) Capture_du_2018-05-23_13-29-34.png
Time calibrator setting
Range 5.12 us
Period 160 ns
Pinned, e744, Wed May 23 15:10:15 2018, iulian, OTHER, General, N/A, Procedure to start stop RUNS fiche_start_run.pdffiche_stop_run.pdf
 
Fixed, e744, Wed May 23 15:40:58 2018, Charles Houarner Valérie, MUST2, Software, N/A, TESTS MUVI internal pulser T1-T4 strips X testGeneInterneT4plotCh5Mate.pngtestGeneInterneT4plotCh5MatePied.pngTestMust2tel4matePulserInt.pngTestMust2tel4PulserIntMate5.pngTestMust2telT1toT3andT5mat5onT4.png
To check the signals and trigger on T4 we used the internal pulser on T4, 
from the SYNCHROTEST pulser at 150 Hz.
The signal was set on the channel 5 of each Mate of the MufeeX card of the T4 telescope:
Fixed, e744, Wed May 23 15:42:04 2018, Louis, Valérie, MUST2, General, N/A, CALIMERO run 409 - XT - T1 to T4 GecoCalimeroMuviTel4Thr1MeV.pngconfigCalim1.pngconfigCalimOKexterne.pngGecoCalimeroMuviGMT.pngHTtelescopesMustsWed23May.png
Started run #409 
GMT triggers: GecoCalimeroMuviGMT.png 
HT on cf : HTtelescopesMustsWed23May.png
Pinned, e744, Wed May 23 17:23:34 2018, Freddy, MUST2, General, , Pedestals and alpha calibration analysis Plot_DiffPedestals.png
Calibration coefficients for MUST2 telescopes were extracted from run_0118 (acquired during night from 13th to 14th of May). They are now located in the
folder:
Fixed, e744, Wed May 23 18:20:59 2018, e744, MUST2, General, N/A, Test Calimero Run 425 
Started run #425 Calimero  NEW XT  T1toT4
ampl Pulser 12MEV; thr for T4 1 MeV
problem on data taking
Ongoing, e744, Wed May 23 20:52:01 2018, Iulian Valerian, RUN, General, , run #429 and #430 and config gmt config_gmt.pngconfig_gmtslave.pngrun430_E_PPT_vs_T_PPT.pdfrun430_E_PPT_proj.pdfrun430_E_EXL_vs_T_EXLor.pdf
Changed VAL from 2 us to 2.5 us

run #429 exl ppt triggers
Fixed, e744, Wed May 23 23:37:14 2018, Valérie L., MUST2, General, N/A, MUVI configuration DAS 13x
Configurations files of the MUVI 1 MufeeX and Y.
On MufeeX and Y configuration:
Note that the thresholds on Must2 T1 to T3 is at 400 keV on May 23th Midnight (same as before); and for T4, now it is set at 1 MeV (not 400 keV).
Fixed, e744, Thu May 24 01:02:19 2018, Valerian, OTHER, General, N/A, run #431 ED4_TD4_23-05-18_00-58.png
[U][B]run #431[/B][/U]
Trigger LISE
Beam in D4
Fixed, e744, Thu May 24 01:10:30 2018, iuliqn, RUN, General, , run 433 Lise trigger 
Should be ql foil in front of the si detector....
Fixed, e744, Thu May 24 01:11:26 2018, Iulian Valerian, RUN, General, N/A, run 434 Lise trigger ED4_TCATSHF_23-05-18_1-18.pngED4_TCATSHF_23-05-18_1-18_efficiency.png
Cats inserted

efficiency is around ~99%
Fixed, e744, Thu May 24 01:53:28 2018, iulian, RUN, General, N/A, run 438 Lise trigger  run_439_d6_cats_hf.pngrun_439_transmisiond4_d6.png
run 438  D4 in
run 439 d6 in.
Ongoing, e744, Thu May 24 02:30:52 2018, iulian, RUN, General, N/A, RUN 440 14N no target trigger Must & cats %100 run440.png
RUN 440 
14N beam  \
no target 
Fixed, e744, Thu May 24 03:21:37 2018, iulian, OTHER, Hardware, N/A, Position measurements Must2/PPT/EXL STP-2018-E054_E744_I-Stefan_J-Mrazek_LISE-D6.pdf
 
Fixed, e744, Thu May 24 03:57:34 2018, iulian, RUN, General, N/A, run 442 Lise trigger d6 cats_e1_d6_t1_D6_run442.png
 
Fixed, e744, Thu May 24 04:20:34 2018, iulian, RUN, General, N/A, run 443 T1-t5 triggers mm5_run443.pngmm5_2_run443.pngmm5_3_run443.pngmm5_4_run443.png
run 443
T1-T5 triggers
Pinned, e744, Thu May 24 05:44:56 2018, iulian, RUN, General, N/A, Important::analysis of the run 443/ things to do t_mm_PPT_run443.pdft_mmhf_run443.pdft_mm_exlor_run443.pdfcorrelation_run443.pdf
[I][B]No stop on t5, but TAC MM_CATS ok.. So two possibilities: 
1) Stop Cable not connected on Muvi2 
2) Problem with the validation of CATS by FAG
Ongoing, e744, Thu May 24 05:59:44 2018, iulian, MUST2, General, N/A, run 444 t1-t4 trigger no target 14n beam mm5_8_run445.pngmm5_7_run444.pngmm5_6_run444.pngmm5_5_run444.pngmm5_4_run444.png
run 444 
t1-t4 trigger
 no target 
Ongoing, e744, Thu May 24 06:30:27 2018, iulian, RUN, General, N/A, run 445 t1-t4 trigger no target 14n beam no CATS mm5_run445_3.pngmm5_run445_2.pngmm5_run445_1.png
 
Pending, e744, Thu May 24 06:53:12 2018, e748, RUN, General, N/A, run #446 CATS trigger 
 
Fixed, e744, Thu May 24 12:01:54 2018, Valérie for Calimero team - Valérian, Fairouz, MUST2, General, , Bug server Calimero Run #447-449 12x
Calimero on ganp161
Telscopes T1 to T4 thresholds for T1 to T3 400 keV ; T4 : 1 MeV
ampli pulser 12 MeV 
Fixed, e744, Thu May 24 17:18:58 2018, Valérie for Calimero team : Valérian, Louis, MUST2, General, N/A, CALIMERO Tests Runs 451 to 452 (done in D6)  configCalimeroRun452YTthr1MeV.pngPlotCalimrun452YTthr1MeVmaybe.pngPlotCalimrun453YT5thr1MeVtrue.png
Test runs for telescopes T1 to t4 
Nb: The applied threshold is now 1 MeV but it seems to be not the case when we look at the spectra.
Maybe a problem of the read configuration in GECO.
Fixed, e744, Thu May 24 17:23:57 2018, Valérie for Calimero team: Valérian, Louis, MUST2, General, N/A, CALIMERO Runs 453-457 OK 16x
Calimero on ganp1074 in D6
Time Calibrator Range: 640 ns; Period 20 ns Amplitude of pulser (test generator) 9MeV  
Run 453 Telescope T5 (MUVI2-slave) XT see plot
Fixed, e744, Thu May 24 19:05:41 2018, e744 team (shift Valérie), RUN, General, N/A, Runs 458 and 459 ScalersEndofRun458_beam14N.pngRun458plotED4TD4HF.pngRun458plotED4_TcatsLise.png
Run 458
focalisation on D4 LISE
100Hz on Si Lise triggers: Cats1div (3 10**4)  LISE 
Fixed, e744, Thu May 24 19:20:40 2018, e744 Must2 + Lise teams (edit: Valérie), RUN, General, N/A, Run 460-Spiral 14N test Run460plotMM5impact.pngScalersDuringRun460.pngMM5impactendofRun460beam.png
Run 460
Triggers Must2 Telescopes T1 to T5
( MM1 to MM5)
Fixed, e744, Thu May 24 19:32:31 2018, e744 Must2 + Lise teams (edit: Valérie), RUN, General, N/A, Run 461-Spiral 14N test ScalersDuringRun461.pngMM5impactDuringRun461.png
Run 461
Triggers Must2 Telescopes T1 to T5
(MM1 to MM5)
Fixed, e744, Thu May 24 19:34:40 2018, e744 Must2 + Lise teams, RUN, General, N/A, tuning Wien-Spiral 14N test 
Run 24May at 19h50-20pm no storage
Triggers Must2 Telescopes T1 to T5
(MM1 to MM5)
Fixed, e744, Thu May 24 20:18:00 2018, e744 Must2 + Lise teams, RUN, General, N/A, tuning Wien-Spiral 14N test MM5impactWien2kV.pngMM5stripsXYWien0.4et0.4kV.pngMM5impactXYWien0.4et0.4kV.pngscalersduringTuningwithWienfilter.png
Run 24May at 19h50-20pm no storage
Triggers Must2 Telescopes T1 to T5
(MM1 to MM5)
Fixed, e744, Thu May 24 20:19:19 2018, e744 Must2 + Lise teams, RUN, General, N/A, Beam centering on MM5-Spiral 14N test MM5strXYWienCenter.pngMM5impactXYWienCenter.pngScalersTuningWienCenterMM5.png
Run 24May at 19h50-20pm no storage
Triggers Must2 Telescopes T1 to T5
(MM1 to MM5)
Fixed, e744, Thu May 24 20:21:57 2018, e744 Must2 + Lise teams, RUN, General, N/A, Run 462 Beam centering on MM5-Spiral 14N test MM5ImpactsRun462.pngBeamOnMM5stripsXYRun462.pngScalersduringRun462.pngScalersEndRun462.png
Run 462 focalisation on target  24May at 20h15pm storage
Triggers Must2 Telescopes T1 to T5
(MM1 to MM5)
Fixed, e744, Thu May 24 20:31:30 2018, e744 Must2 + Lise teams (edit: Valérie), RUN, General, N/A, Run 463 Beam Spiral 14N test scalersendOfRun463.pngMM5stripsXYERun463.pngMM5ImpactsRun463.png
Run 463 focalisation on Must2  24May at 20h30pm storage
Triggers Must2 Telescopes T1 to T5
(MM1 to MM5)
Fixed, e744, Thu May 24 21:05:05 2018, Valerian Iulian and Francois, TARGET, Hardware, , 14N - 187um target placement 20180524_210115.jpg
For resonant elastic scattering of 14N(pp)14N the 187um target is placed.
Fixed, e744, Thu May 24 21:05:19 2018, e744 Must2 + Lise teams (edit: Valérie), MUST2, Hardware, N/A, change of STOP MUST2 
The STOP of MUST2 with CATS is now directly the CATS "delayed signal".
No coincidence with FAG.
NB: the CATS "delayed signal"is the fast time signal from CATS in D4, which is sent to the DAQ area of D6, then delayed.
Pinned, e744, Thu May 24 21:13:29 2018, Valerian, TARGET, General, N/A, List of target present in M2C 
The list of target present in M2C chamber are the following : 

6 -> [B]CH2 : 187 um[/B] / 17.391 mg/cm2 (Georges) -> Full resonance spectra
Fixed, e744, Thu May 24 21:28:45 2018, e744 Must2 + Lise teams (edit: Valérie), RUN, General, CH2, Run 464 Beam Spiral 14N test TAcrefGAGmmCatsHFRun464.pngScalersDuringRun464at21h30.pngMM5ImpactsRun464.pngMM5ImpactsRun464zoom.pngMM5StrXYRun464.png
Run 464 focalisation on Must2  24May at 21h25m storage
Triggers Must2 Telescopes T1 to T5
(MM1 to MM5)
Fixed, e744, Thu May 24 22:38:44 2018, e744 Must2+lise teams , RUN, General, CH2, Run Beam Spiral 14N centered 7x
  Shift teams: François, Iulan, Freddy, Fairouz, Valérian, Valérie, Mihail
LISE teams during evening: Omar Kamalou, Luc Perrot, Pierre Delahaye
Triggers Must2 Telescopes T1 to T5
Fixed, e744, Thu May 24 22:45:36 2018, e744 Must2+lise teams , RUN, General, CH2, Run 1001 Beam Spiral 14N centered scaler-run1001.pngMMimpactsRun1001.png
Run 1001, cible n°6: 183 um
start @ 21h55; Stop @ 22h36 
 Shift teams: François, Iulan, Freddy, Fairouz, Valérian, Valérie, Mihail
Pinned, e744, Thu May 24 23:20:40 2018, e744 Must2 + Lise teams, RUN, General, CH2, run 1002 scaler-stop-run1002.png
[I][B]run 1002:[/B][/I] 14N beam, CH2 187 um
trigger: MM1,2,3,4,5 + CATS%, EXL%, PPT%
start: 22h41
Fixed, e744, Fri May 25 00:09:03 2018, Cristina , RUN, General, CH2, run 1003 (target no 6 -CH2 180 um) 6x
run 1003

14N
Fixed, e744, Fri May 25 00:41:19 2018, Cristina and Pedja, RUN, General, CH2, run 1004 (target no 6 -CH2 180 um) 7x

Run 1004
the thresholds of MUST detector changed to ~0.5 MeV
Fixed, e744, Fri May 25 01:05:05 2018, Cristina and Pedja, RUN, General, CH2, run 1005 (target no 6 -CH2 180 um) scalers_start_run1005.pngscalers_stop_run1005.pngMMimpactsRun1005.pngTAC_run1005.png

Run 1005
Fixed, e744, Fri May 25 02:35:13 2018, Cristina and Pedja, RUN, General, CH2, run 1006 (target no 6 -CH2 180 um) scalers_start_run1006.pngscaler-stop-run1006.pngtac-run1006.pngmm_impact_run1006.png

Run 1006
Ongoing, e744, Fri May 25 02:57:44 2018, Valerian and Iulian, OFFLINE, General, CH2, Simulation Azure 1H(14N,p) and measurement  o15.pdfE_cm_ThetaLab_0_4.pdfE_cm_ThetaLab_2_3.pdfE_cm_ThetaLab_10_12.pdfE_cm_ThetaLab_15_20.pdf
We can know conclude without any doubt that we were able to measure resonances from 1H(14N,p)14N. The resolution with a rough analysis and the current bad
calibration is around 180keV in the com.
Identification of resonances is still difficult but some structure seems consistent with previous works. Also, at higher energy there are only few measurement
Pinned, e744, Fri May 25 04:02:29 2018, Valerian Iulian Pedja and Cristina, OTHER, General, N/A, General power cut of ganil 
Due to some water leaks, CSS1 CSS2 and CIME as the vacuum system of GANIL are down... Time loss could be considerable... They talked about beam possibility
in the morning but it seems unlikely.
Fixed, e744, Fri May 25 08:37:04 2018, Adrien Matta, MUST2, Hardware, N/A, MUST2 cooling 
Vacuum at 1.7 e-5 torr this morning.
I started the MUST2 cooling, setting both coolers at -5C.
Time of operation 8h35.
Pending, e744, Fri May 25 13:08:44 2018, e748, OTHER, Software, N/A, CSH is broken 
Someone change the .cshrc file this morning this morning at 11h30. None of the alias worked anymore.
Pinned, e744, Fri May 25 14:10:34 2018, Freddy, Louis, Lama, OFFLINE, General, , MM - dE_TOF diagnostic with/without CsI_E T2_diag_dETOF.pdfMM12345_diag_dETOF.pdf
Attached are some plot of dE-TOF PID for run 1004 after the threshold change ( 1 MeV --> 500 keV).

Putting a condition on CsI_E>0 select well punch through event as expected.
Ongoing, e744, Fri May 25 15:10:23 2018, François, CATS, Hardware, , delay on CATS 
CATS delay 500 ns was changed to 300 ns, in order to get the stop signal on MUST2 TAC well within the range of the TAC. 
Ongoing, e744, Fri May 25 15:19:38 2018, Cristina, OFFLINE, General, , isomers present in the 14N runs 14Nruns_isomers_EXL.pdf14Nruns_isomers_PPT.pdf

Attached are some pictures of the energy_vs_time spectra for EXL and PPT detectors recorded during 14N runs
Fixed, e744, Fri May 25 15:29:51 2018, François, OTHER, Hardware, , tac FAG_HF 
A delay of 500 ns was put to the start signal = FAG of the FAG_HF_validated TAC
and a range of 500 ns selected
Fixed, e744, Fri May 25 15:41:50 2018, e744- Valérie, DAQ, General, N/A, DAS configurations for E744-Summary 11x
List of the saved files of the DAS configuration used on May-24h and May-25th:
[Note that:
All the files are used on run with the name "e744.das".
Ongoing, e744, Fri May 25 16:49:53 2018, e748, MUST2, General, CH2, Raw dE-TOF bidim for the 5 telescopes zith the 14N beam Example1.png
Pedestal seems not to be aligned for T4
Fixed, e744, Fri May 25 17:42:21 2018, shumpei, MUST2, Software, N/A, CsI energy calibration for MUST2 telescopes 6x
Calibration parameter for MUST2 CsI crystals are calculated with run1001-1006.
Attached are dE(DSSD)-E(CsI) plot of all the telescopes and parameters.
The parameter files are in
Fixed, e744, Fri May 25 17:51:45 2018, e744 Iulan Valérie, RUN, General, CH2, Run 1008 starting runs with 14N BTdssdMust2_25May18.pngHTdssdMust2_25May.pngHV_EXL_25May.png
[U][B]BAD RUN FOR 14N[/B][/U]

Run 1008 BAD RUN 0 Events
Fixed, e744, Fri May 25 18:15:41 2018, Pierre, MUST2, General, CD2, new dEE PID using Shumpei calibration PID_dEE_newCsIcalib.png
 
Fixed, e744, Fri May 25 21:34:19 2018, e744 Iulan, Fairouz, Valerie, DAQ, Hardware, CH2, Problem of FAG validation +change of ADC parameter for TAC signal ProblemGMTtriggerVXI.png
The Time signal  MM_PPT is now in the parameter MCP_HF of the ADC.
The problem was on the FAG signal validation (bad output of the discriminator) 
Fixed, e744, Fri May 25 21:37:45 2018, iulian nicolas valérie, RUN, General, N/A, run 1012 all triggers 14O beam in D4 Run1012_E1_TcatsHF.pngRun1012_E1_T1HF_D6.png
 
Fixed, e744, Fri May 25 22:03:12 2018, e744 Must2+LISE teams, RUN, General, CH2, RUNS 2000, 2001 6x
Beam 14O
Run 2000 start with all triggers, including LISE trigger, during 1 minute for tests.
 start 22:00:58; stop 
Fixed, e744, Fri May 25 22:46:26 2018, e744 Must2+LISE teams, edit Valérie, RUN, General, CH2, RUN 2004 6x

 Run 2004   Date : 25/05/2018 22:45:58  25/05/2018 23:17:39 
End of Run, error Narval see snapshot ProblemNarvalRCCEndRun2004.png
Ongoing, e744, Fri May 25 23:15:57 2018, Valerian, OFFLINE, General, CH2, Oxygen 15 excitation function Exc_15O.pdf
After a quick analysis, we can conclude that MUST2 is working for resonant elastic scattering. We find a resolution of 125 keV which will improve with a
better analysis, as we are using a basic calibration for CsI Energy.
Fixed, e744, Fri May 25 23:26:23 2018, e744 Must2+LISE teams, edit Valérie, RUN, General, CH2, START NARVAL, new version ResolProblemNarvalEndofRun25may23h.png
the NARVAL version is now reinstalled by Fred Saillant.
see plot  ResolProblemNarvalEndofRun25may23h.png
 
Fixed, e744, Fri May 25 23:33:27 2018, iulian, OTHER, Hardware, CH2, changes after run 2004 impact_matrix_run_2005.png
Target was changed to target number 5 (CH2 100 um GOODFELLOW)
The T_EXL1718 ok
Fixed, e744, Sat May 26 00:24:50 2018, e744 valérie, DAQ, General, CH2, change of trigger and division TRIGGERgmtChangedForCATS.png
TRIGGER entry for CATS, presently IN8, seems to be not running. We put it on IN7(Gatconf =64).
divisions EXL 10**4
PPT 3000
Fixed, e744, Sat May 26 00:38:38 2018, e744 all night shift teams, (edit) Valérie, RUN, General, CH2, Run 2010 20x
RUN 2010
Date : 26/05/2018 00:37:44
 Target n°5  CH2 100 µm 
Fixed, e744, Sat May 26 01:41:19 2018, e744 night shift team, edit valérie, DAQ, General, CH2, summary GMT, DAS config since run2005 chronoGMTmasterRun14O.pngchronogramGMTslave_Run14O.pngConfigDASThresMUST2at1MeV.pngConfigTDCTestParamInpectch0.png
 Triggers: all except LISE

IN1 to IN5 : MM1 to MM5;
Fixed, e744, Sat May 26 02:39:18 2018, Mihai, Pedja, RUN, General, CH2, Run 2011, Target n°5 9x
RUN 2011
Date : 26/05/2018 
Beam used: 14O
Ongoing, e744, Sat May 26 03:23:46 2018, Valerian, OFFLINE, General, CH2, 15O excitation function as a function of ThetaLab Ex_15O.pdf
 
Fixed, e744, Sat May 26 04:24:16 2018, Mihai, Pedja, RUN, General, CH2, Run 2012, Target n°5 Scalers_start_run2012.png
RUN 2012
Date : 26/05/2018 
Beam used: 14O
Ongoing, e744, Sat May 26 05:02:42 2018, Valerian, TARGET, General, CH2, Problem with the target for run 2004 and 2010 Target_Issue_2004_2010.pngtargets.jpg
The target seems identical between the two runs... We will have to investigate to understand what is going on.

The decision is to change the target 5 for the target 4 104um from georges.
Fixed, e744, Sat May 26 05:16:12 2018, Iulian Valerian, pedja, mihai, TARGET, General, CH2, Target change 
Target No 4 is placed in-beam 5h15.
Fixed, e744, Sat May 26 05:23:12 2018, Mihai, Pedja, RUN, General, CH2, Run 2013, Target n°4 Scalers_start_run2013.pngRun2014MM_IMPACT5h53.png
RUN 2013
Date : 26/05/2018 
Beam used: 14O
Fixed, e744, Sat May 26 05:51:00 2018, Mihai, Pedja, RUN, General, CH2, Run 2014, Target n°4 9x
[U][B]RUN 2014[/B][/U]
Date : 26/05/2018 
Beam used: 14O
Fixed, e744, Sat May 26 06:05:13 2018, Iulian Valerian Pedjia, TARGET, General, CH2, Target issue No5 Target_Issue_2004_2010_corrected_withGeorgesTarget.png
In the attached figure it could be seen that with the target No5 (run 2010) lower energy resonances were visible (lower part of the figure), which is not
the case with the target No4 (upper part)from run 2013.
Ongoing, e744, Sat May 26 07:03:12 2018, Valerian and Iulian and Francois, OFFLINE, General, CH2, First picture for 15F from runs 2010-2013 Ex_15F_proj_0_8deg_17_27.pdfsig_theo.jpg
Target -> Thick target (Sandwich target ??)

The predictions are different....  
, , Sat May 26 07:20:03 2018, , , , ,  
 
Ongoing, e744, Sat May 26 07:32:17 2018, Valerian, pedja, mihai, RUN, General, CH2, Run 2015 after vacuum problem of Css1 target 4 Scalers_start_run2015.png
[U][B]Run 2015[/B][/U] 
26/05/18
start @7h29
Fixed, e744, Sat May 26 09:33:48 2018, Giuseppe, Dieter, RUN, General, CH2, run 2015 MUST2_end_run2016.pngScalers_stop_run2015.pngMUST2_y_ongoing_run2018.png
Missing strips:
x
MM1 1
Fixed, e744, Sat May 26 10:03:37 2018, Giuseppe, Dieter, RUN, General, , run 2016& 2017 


Problems with the ACQ (merger), they were solved by making Breakup and Init
Ongoing, e744, Sat May 26 10:06:06 2018, Giuseppe, Dieter, RUN, General, CH2, Run 2018 Scalers_start_run2018.pngScalers_stop_run2018.pngMM_IMPACT_stop_run2018.png
Run 2018 
Start @ 09:56 26/05/2018
Stop @ 10:51
Fixed, e744, Sat May 26 11:19:37 2018, Giuseppe, Dieter, RUN, General, CH2, interruption due to to waterleak ibn CSS1 
10:50 h Water leak at CSS1
        cryo pumps have to be regenerated
        continuation until the expert intervention starts is possible
Fixed, e744, Sat May 26 11:42:03 2018, Giuseppe, Dieter, RUN, General, CH2, run 2019 scalers_start_run2019.pngscalers_stop_run2019.png
Run 2019

Pending, e744, Sat May 26 13:22:08 2018, Francois, BEAM, General, , problem with CSS1 
There is a leakage of water in cavity north of cyclotron CSS1. I discussed with Alain Savale. 

[B]There are 2 options:[/B]
Fixed, e744, Sat May 26 14:03:27 2018, Giuseppe, Dieter, J. Eric, RUN, General, CH2, Run 2020 9x
run 2020

Fixed, e744, Sat May 26 16:31:53 2018, Jaromir, Giuseppe, EXL-PPT, Software, N/A, EXL calibration, light leak batchSelector.CEXL.pdfpairs0102_0910.pdfpairs1112_1718.pdf
Selector.C can be used to adjust energy bad reconstruction in the EXL detectors due to energy leak (see the PDF attached for more information about it)
once we already have the coefficients for the energy on EXL crystals. To operate with it, for first calibration coefficient must be deduced. Once it is
done the slopes and offset of the calibration have to be inserted in Selector.C file at lines 41 (a[19]) and at line 49 (b[19]). After thqt thresholds
Ongoing, e744, Sat May 26 20:20:55 2018, Valerian, OFFLINE, General, CH2, 15F observations for target 4 (100um) Ecm_Thetacm_target4_notes.pdfEx_15F_proj_0_4deg_Ecm_target4.pdfEx_0to40degEcm_15F.pdf
Analysis offline permits us to conclude that the current target has the good size to observe our resonances.
Ongoing, e744, Sat May 26 20:23:52 2018, Cristina Iulian, OFFLINE, General, , PPT gamma spectrum runs_target4_proton_prompt_PPT.pdf
 Attached is the gamma spectrum from PPT detector with a condition on prompt (T_MM_PPT), proton detected in MUST and multiplicity event equal to 1
Pending, e744, Sun May 27 15:36:31 2018, François, BEAM, Social, , News updated 
19H
They succeeded to get 90 % transmission with CSS1 but the energy at the exit was changed by 4%, that is not compatible with the CSS2 limit of 1 %. After
fitting the CSS1 energy they obtained 70-80 % transmission only, but it is enough.  The problem with the HF of CSS2 was solved. They are trying to accelerate
Fixed, e744, Sun May 27 20:47:02 2018, e744- Valérie, DAQ, Hardware, N/A, Info to reboot the crates in case of problem IOLANmust2reboot.pngRunControlE744Ready.png
In case of problems in the run control, if it is not possible to reinstall the crates in the  "Ready" mode status, 
it is possible to reboot them remotely via the software commands.
this can be done using the iolan windows.
Ongoing, e744, Mon May 28 02:07:41 2018, Valerian, OFFLINE, General, CH2, New improved resolution for 14N et 15F Exc_15O_newpos.pdfExc_15F_newpos.pdf
After correcting position for the Must2 detectors by taking into account the real hit position on the target that was (0,15cm,0) and not (0,0,0). The way
to do it was to artificially move every detector 15cm lower.
Fixed, e744, Mon May 28 11:00:07 2018, Valerian and Iulian and Phil, RUN, General, , two protons  e2p_15O.pdf
 
Fixed, e744, Mon May 28 12:22:42 2018, Francois & Marlete, OFFLINE, General, , superposition exp / theory for 15O and 15F sum.jpg15F_final.jpg
 
Pending, e744, Mon May 28 16:14:29 2018, François & Valérie, MUST2, General, N/A, Cooling system 
 Monday 28th 16h10: we refill the cooling system for MUST2. The level should be ok for the rest of the experiment.
(Around 4 days).
Fixed, e744, Mon May 28 16:32:38 2018, E744- Valérie, DAQ, General, N/A, DAS configuration files-References 15x
 
Fixed, e744, Mon May 28 18:27:45 2018, E744- Valérie, DAQ, General, N/A, High Voltages and intensities on MUST2 HT_MUST2withoutBeam28may18.png
 Check regularly the HT on the MUST2.
NB: without beam the current on Telescope 4 is high, between 9 and 11 µA. see snapshot.
NB: The Ioset was increased at 20 µA on Friday 25th (cf Id entry=490) to avoid trips on this telescope due to strong intensity fluctuations due to the
Ongoing, e744, Mon May 28 20:28:50 2018, Valerian and Simon, OFFLINE, General, CH2, Explanation for the 0 degree low energy proton explanation_spotT5.pdf
The 0 degree energy proton are coming from the beam hitting the aluminum target. If you do a cut on the beam projection on T5 you obtain the black dot on
the joined plot.
Fixed, e744, Mon May 28 20:33:39 2018, E744- evening shift LISE+e744 teams (edit Iulan, Valérie), RUN, General, CH2, BEAM AGAIN RUN 2100 Tuning beam_spot_2100_end.png
  See plot of the Must2 impacts, Wien filter set at +/-0.8kV  
Beam on CATS 1.2 10**5 pps
CH2 183 µm
Fixed, e744, Mon May 28 20:38:21 2018, E744- evening shift LISE+MUST2 teams (edit Valérie), RUN, General, CH2, RUN 2101 DATA target 4 12x
[U][B]run #2101[/B][/U]
start @20h27
stop  @22h20
Fixed, e744, Mon May 28 22:11:52 2018, e748- Louis, EXL-PPT, Hardware, CH2, EXL4 trigger excess Scaler_EXLTriggerExeed_Run2101.png
During run 2101, Frequency of the EXL4 channel at 478Hz compared to values around 30Hz for other channels
Fixed, e744, Mon May 28 22:27:14 2018, Simon et Louis, RUN, General, CH2, RUN 2102 DATA target 4  Scaler_start_Run2102.pngScaler_stop_Run2102.png
run #2102
start @22h20
stop @23h30
Ongoing, e744, Mon May 28 23:14:26 2018, Valerian and Iulian and Phil, OFFLINE, General, CH2, New hint of the 5/2- resonance New_resonance_hint.pdf
We see a new hint of a resonance
Fixed, e744, Mon May 28 23:52:19 2018, Simon and Louis (start), Franck (stop), RUN, General, Carbon, RUN 2103 DATA target 1 Carbon Scaler_start_Run2103.pngScaler_stop_Run2103.png
run #2103
start @23h49
stop @1h51
Ongoing, e744, Tue May 29 00:17:18 2018, Night shifter, BEAM, General, Carbon, Beam intensity variation hv_run2103.png
Beam shut down at 00h03. Increase the intensity progressively up to now 00h18.
At 0:28: primary intensity dropped down to 0.
Fixed, e744, Tue May 29 01:08:22 2018, e748, BEAM, General, Carbon, Beam intensity 
At 0:46 primary beam intensity reaches 5 uA -> 1.5e5 pps on CATS.
Ongoing, e744, Tue May 29 01:25:07 2018, Phil, Valerian, Franck, EXL-PPT, General, N/A, LaBr3 Background for reference Response-of-3-3-CeBr-3-and-LaBr-3-Ce-to-natural-background-radiation-Events-due-to.jpg.png
For reference, we include a picture of the LaBr3 background found by some random Google searching until we found a nice happy looking picture.

Remember (I'd forgotten despite having literally had this conversation with someone in the past) that the LaBr3 internal background lies at exactly the
Ongoing, e744, Tue May 29 01:33:58 2018, Phil, Valerian, Franck, EXL-PPT, General, , Gamma-ray spectra from PPT PPTSpectrum2D.pngPPTSpectrumPromptPeak1.pngPPTSpectrumPromptPeak2.png
Attached are plots of gamma-ray energy spectra from PPT.

2-D plot is the PPT-CATS time (from PPT-MUST2 and MUST2-CATS time, obviously).
Fixed, e744, Tue May 29 02:01:58 2018, Franck, Valerian, Phil, RUN, General, Carbon, Run 2104 - Target 1 Carbon Scaler_start_Run2104.pngScaler_stop_Run2104.png
Run 2104
Beam: 14O
Start @ 2:00  29 May 2018
Fixed, e744, Tue May 29 02:38:21 2018, Franck, Valerian, Phil, ONLINE, General, Carbon, Spectra and HV Start Run 2104 11x
 
Fixed, e744, Tue May 29 04:08:52 2018, Franck, Valerian, Phil, RUN, General, Carbon, Run 2105 - Target 1 Carbon Scaler_start_Run2105.pngScaler_stop_Run2105.png
Run 2105

Beam 14O
Ongoing, e744, Tue May 29 05:07:33 2018, Valerian, OFFLINE, General, CH2, Fusion evaporation background and physics data Ex_15F_and_Carbon.pdfrough_backgrund_suppresion.pdf
Comparison between the fusion evaporation background and the data for the telescope 5 ~0degree angles and rough subtraction of this background.
Ongoing, e744, Tue May 29 05:24:34 2018, Valerian, EXL-PPT, General, CH2, Comparison of background and physics data for gamma ray detectors gamma_comparison_CH2_and_Carbon.pdfbackground_substr_gamma_ray.pdf
Gamma ray spectrum for both targets seem extremely close. Subtraction is then made but no gamma show. More statistic is needed
Ongoing, e744, Tue May 29 06:09:58 2018, Franck, Phil, RUN, General, Carbon, Run 2106 - Target 1 Carbon Scaler_start_Run2106.pngScaler_stop_Run2106.png
Run 2106

Beam 14O (CATS: 1.4e5 pps)
Ongoing, e744, Tue May 29 07:39:53 2018, Franck, Phil, RUN, General, Carbon, Run 2107 - Restart after Reboot of VXI - Same problem 
Low FAG rate: 30 /s
Low ORD rates: 0-10 /s, 15 /s on MM5
Ongoing, e744, Tue May 29 08:09:02 2018, e748, RUN, General, Carbon, RUN 2108 - Target1 Carbon 11x
[B][U]Run 2019[/U][/B]

Acq recovered
Ongoing, e744, Tue May 29 08:59:18 2018, Freddy, Iulian, Pierre, RUN, General, CH2, Run 2109 - Target 4 CH2 - Tuning run impact_Run2109_end.png
[U][B]Run 2109[/B][/U]

Beam: 14O (1.5*10^5 pps)
Pinned, e744, Tue May 29 09:30:42 2018, Freddy, Iulian, Pierre, RUN, General, CH2, Run 2110 - Target 4 CH2 Scaler_start_Run2110.pngimpact_Run2110.png
Run 2110

Beam: 14O (1.5*10^5 pps)
Pinned, e744, Tue May 29 09:54:01 2018, Freddy, Iulian, Pierre, RUN, General, CH2, Run 2111 - Target 4 CH2 8x
Run 2111

Beam: 14O (1.5*10^5 pps)
Fixed, e744, Tue May 29 10:42:00 2018, Francois, BEAM, General, , effective beam time os1.jpeg
In total, there were:

1.4 UT of 14O, average 2x10^5 pps
Fixed, e744, Tue May 29 12:06:05 2018, iulian maurycy, OFFLINE, General, CH2, Carbon substraction  Carbon_runs_scale_factor.pdf
The scale factor for Carbon subtraction is 1.224. This means: RealCountsHidrogen=Counts CH2 - 1.224 * CountsCarbon 

runs considered for the CH2 target
Ongoing, e744, Tue May 29 15:53:17 2018, Iulian Maurycy, OFFLINE, General, CH2, Angular distribution per telescope 1-4 ang_dist.pdf
Angular distribution per telescope 1-4
Ongoing, e744, Tue May 29 16:23:56 2018, Valerian Iulian Maurycy, OFFLINE, General, CH2, Hint of a 2p peaks  Two_proton_14Ovs12C.pdf
 
Fixed, e744, Tue May 29 17:14:41 2018, François, Freddy, Valérie, BEAM, General, , Beam back in D6 HV_MUST2_29mayAt17h20.pngHV_EXL_29mayAt17h21.png
At 17pm Tuesday 29th we have beam coming back in D6. Run (without storage)
NB: The current on T4 (with Hv set 60V) is fluctuating between 4 and 6.5 µA.
Ongoing, e744, Tue May 29 18:49:21 2018, Valerian, OFFLINE, General, CH2, Comparison of gamma prompt spectrum for EXL and PPT prompt_energyEXL_12C_14O.pdfprompt_energyPPT_12C_14O.pdf
Quick note, there is less data seen in EXL prompt. This should be investigated
Fixed, e744, Tue May 29 19:03:38 2018, Valérie (edit), RUN, General, CH2, Run #2112 BEAM BACK 14x
run #2112
Beam back given by the machine. 
Beam+ Lise team: Omar K and Pierre Delahaye, Jean-Charles T.
Fixed, e744, Tue May 29 21:41:55 2018, Valérie, RUN, General, CH2, Run #2113 9x
[B]RUN #2113 start @ 21h37; stop 0h14 @ [/B] 
 target n°4. CH2 104 µm
All triggers, (no LISE)
Fixed, e744, Wed May 30 00:17:02 2018, Valérie, Louis, RUN, General, CH2, Run #2114 8x
[B]RUN #2114 30 mai 2018 start @ 0h15; stop  @ 2h58[/B] 
BEAM STOP DUE to the shut down of the deviation element at the entrance of our D6 area.
 target n°4. CH2 104 µm
    Fixed, e744, Wed May 30 01:15:58 2018, Valérie, Louis, RUN, General, CH2, Run #2115 6x
[B]Since 2h58 : WAITING FOR THE BEAM TO START THE RUN[/B]

[B]RUN #2115 30 mai 2018 start @ 03h20; stop  @ 4h56[/B] 
Ongoing, e744, Wed May 30 01:30:34 2018, Valerian, OFFLINE, General, CH2, Checking the T4 
After checking every telescope, it seems that the calibration of T4 is very off, I think that for now, it might be a good thing to consider this telescope
out of the analysis ?
Ongoing, e744, Wed May 30 03:09:09 2018, Valérie, Louis, RUN, General, CH2, BEAM LINE PROBLEMS, alarm "water leakage" HT_MUST2_Wed30May_At5h52.png
 The beam was stopped at 4h56, due to the alarm of "water leakage" on equipments, indicated in the D6 area.
All QPole in D6 were automatically put to 0.
Wien filter and DAP were put OFF to stop the beam and enter in the D6 area.
Fixed, e744, Wed May 30 07:06:58 2018, François, Louis, Valérie, RUN, General, CH2, Run 2116 Run2116_initScalers.pngHT_MUST2_Wed30May_At7h05.pngRun2116_MMimpacts_At7h23.png
Wednesday 30th May.
Beam back at 6h59. Run 2116 started at 6h69. STOP at 8h33 (beam rate decreasing at the end of the run due to machine problems).
Fixed, e744, Wed May 30 08:34:51 2018, Valérie, RUN, General, CH2, Run 2117- low or no beam Run2117_scalersINIT.png
Wednesday 30th May.
Run 2117 started at 8h36 ; Stop at 8h45:   BEAM STOP.  
Beam decreased at the end of Run 2116, still very low at the beginning of run 2117, 300 pps then 3 pps.
Ongoing, e744, Wed May 30 09:24:28 2018, Valérie, Adrien, Freddy, RUN, General, CH2, Run 2118 Run2118_scalersINIT.pngRun2118_HT_EXLat9h29.pngRun2118_scalersIat9h33.pngRun2118_MMimpacts.pngRun2118_CsIExlandETimePPT.png
Wednesday 30th May.
Run 2118 started at 9h23 ; 
Stop at: 11h25
Ongoing, e744, Wed May 30 11:17:00 2018, Valerian maurycy and Olivier, OFFLINE, General, CH2, Condition on time T5 SiEvsSiT_T5_issue.png
One should add the condition Si_TX < 150 for T5, problem from Ta?
Ongoing, e744, Wed May 30 11:22:16 2018, Valerian maurycy and Olivier, OFFLINE, General, CH2, Checking the cuts 
cut_DeE : 

- T1 OK
Fixed, e744, Wed May 30 11:42:41 2018, Freddy, Adrien, RUN, General, CH2, Run 2119 - Target 4 CH2 Run2119_initScalers.pngRun2119_MMimpacts_At11h25.pngRun2119_TAC.pngRun2119_Trigger.pngRun2119_HT.png
[U][B]Run 2119[/B][/U]

Start: 11h25m53s  
Fixed, e744, Wed May 30 13:25:57 2018, Phil, Freddy, RUN, General, CH2, Run 2020 - target number 4 Scalers_start_run2020.pngRun2020_leakages_13h35.png
Run 2020

Start: 13h24m
Ongoing, e744, Wed May 30 13:48:02 2018, Phil, DAQ, General, N/A, Pulser values 
Here's a list of pulser values taken from the last few runs as a reference for what rate the "100-Hz" pulser is actually seeing.

All rates in Hz.
Pending, e744, Wed May 30 15:26:40 2018, Francois Marlete, BEAM, General, , problem with beam 
14H00 : The primary beam was misaligned, they are still working on it. No 14O beam.
Ongoing, e744, Thu May 31 16:42:30 2018, iulian, EXL-PPT, General, 60Co, Run 3000 60Co source PPT & EXL triggers Scalers_start_run3001.pngScalers_stop_run3000.pngppt_exl_run3000.pngppt_exl2_run3000.png
Run 3000 
60Co source 
PPT & EXL triggers
Ongoing, e744, Thu May 31 17:45:21 2018, iulian, MUST2, General, 3-alpha, run #3001 alpha source T1-T5 scaler_startt_run3001.pngscaler_stop_run3002.png
run #3001 
alpha source T1-T5
Fixed, , Fri Jun 1 11:11:13 2018, e748, EXL-PPT, General, 60Co, run #3002 ppt trigger scaler_start_run3003.png
run #3002 ppt trigger

start 11h11
Fixed, e744, Fri Jun 1 12:06:47 2018, Valerian, EXL-PPT, General, 60Co, run #3002 Calib PPT scaler_start_run3002.pngscaler_stop_run3002.png
run #3002
start @11h09
stop  @12h04
Fixed, e744, Fri Jun 1 13:12:16 2018, Valérian, EXL-PPT, General, 60Co, run #3003 Calib EXL scaler_start_run3003_ok.pngscaler_stop_run3003_ok.png
run #3003
start @12h06
stop @13h08
Fixed, e744, Fri Jun 1 19:19:20 2018, Valerian, MUST2, General, N/A, Calimero end 
For the end of e744 the calimero runs are the following ones :

run 3009 X T1-4
Fixed, e744, Fri Jun 1 19:29:17 2018, Valérian, EXL-PPT, General, 60Co, EXL efficiency 
To test EXL efficiency I start a long run with the source in front of it.
run 3014
start @19h25
Fixed, e744, Mon Jun 4 18:45:15 2018, shumpei, MUST2, Hardware, N/A, No data for two CsIs of MUST2 csin.pdfcsip.pdf
During E744 experiment, two CsI crystals (number 1 & 10) of MM2 had no data as attached.
When the M2C chamber was opened today, I found at least connection for CsI number 1 of MM2 has a problem.
It takes some time to fix the connection for CsI, so it may be going to be fixed after some hardware problems are found in this week.
Fixed, e755, Thu Jun 7 09:46:47 2018, Louis, MUST2, Hardware, 3-alpha, MUST2 test MMYE1_4_3alpha_06062022.pngMMYE1_4_3alpha_06062021.pngMMYE1_4_3alpha_06062020.pngMMYE1_4_3alpha_06062019.png
The 8 MUST2 telescopes have been installed and pluged in final configuration. Energy signal have been tested with 2 3-alphas sources, one in front of T5-T6
and one in front of the others. 
Energy signal for all telescopes looks ok exept for telescopes 5. Concidering their position with respect to the source T5 and T6 should have the same
Fixed, e755, Thu Jun 7 12:19:18 2018, Louis, MUST2, Hardware, N/A, MUST2 configuration, X1Y1 and PCB numbers  Config_MUST2.jpgConfig_MUST2_T56.jpg
Pictures showing the MUST2 configuration. 
X and Y positions and PCB numbers are as folow are as follow: 
Fixed, e755, Thu Jun 7 13:54:59 2018, Louis, MUST2, Hardware, N/A, MUST2 Time MMXT1_4_07062018.pngMMYT1_4_07062018.pngMMYT5_8_07062018.pngMMXT5_8_07062018.png
MUST2 time have been tested for T1 to T8 for X and Y. FAG has been delayed with 150ns and 500ns and sent as stop in MUVI 1 and 2. One can see two pics in
all spectrum. All scales of TAC have been setted to 600ns.
Fixed, e755, Thu Jun 7 17:12:38 2018, Louis, MUST2, Hardware, 3-alpha, Calib Alpha MMYE1_4_08062020.pngMMYE5_8_08062020.pngMMXE1_4_08062019.pngMMXE5_8_08062019.png
Run 3028: Calib 3 alpha started at 17h05
Run3029:Calib 3 alpha started at 17h54
Fixed, e755, Sun Jun 10 19:51:52 2018, Louis, MUST2, Hardware, 3-alpha, Calibration run MMYE1_4_11062020.pngMMYE5_8_11062020.pngMMXE1_4_11062020.pngMMXE5_8_projection_11062020.png
Run3031:Calib 3 alpha started at 19h49
stoped at 9h15
Fixed, e755, Mon Jun 11 12:50:56 2018, Louis, MUST2, Hardware, 3-alpha, Impact matrix 8x
Impact matrix for Telescope 1 to 8 from the run 3029 calibrated
Fixed, e755, Mon Jun 11 13:28:21 2018, Louis, ONLINE, Hardware, 3-alpha, Energy resolution MUST2 
Energy resolution of the 8 MUST2 telescopes from central pic of run 3029 calibrated with 3 alpha source.

T1: mean = 5.389MeV  ,  sigma = 15.0keV
Fixed, e755, Wed Jun 13 11:40:18 2018, Adrien Valérian Louis, MUST2, Hardware, 3-alpha, RUN Source 4 Alpha EY_T1_4_13062020.pngEY_T5_8_13062020.pngEX_T1_4_13062020.pngEX_T5_8_13062020.png
run 1: 4 alpha source, without heat shield, 1 bar air inside the target cell.

Data has been taken with a 4 alpha source: 3 alpha around 5Mev plus one around 8.7MeV
Fixed, e755, Wed Jun 13 18:20:02 2018, linda, Daisuke, Louis, MUST2, Hardware, 3-alpha, Run test with heat shield EX_T5_8_14062021.pngEX_T1_4_14062021.pngEY_T1_4_14062021.pngEY_T5_8_14062021.png
Run 9: heat shield added with two MYLAR foil of 2um, vacuum has been made inside target cell. 4 alpha source
Fixed, e755, Thu Jun 14 19:03:06 2018, shumpei, OFFLINE, Hardware, N/A, 8MeV alpha source T5&T6 tqrget.pdf
8MeV alpha source image on the target was reconstructed from T5&T6 hit position and target position information.
The target is something like 2 cm diameter collimator.
Now the center of the image is a little bit close to T6(bottom) maybe because the center of the target is placed to bottom side at room temperature since
Ongoing, e755, Sun Jun 17 11:12:57 2018, takeshi, TARGET, Hardware, N/A, current cooling status of the cryogenic target 
This is the temperature log of the cryogenic hydrogen target during the cooling test done last night.
The temperature of the heat shield (green line) and the cell (blue line) increased while it went the minimum values at once.
Fixed, e755, Sun Jun 17 11:25:31 2018, takeshi, TARGET, Hardware, N/A, current cooling status of the cryogenic target temperaturelog.pngpeak.pngboilingpoint.png
This is the temperature log (temperaturelog.png) of the cryogenic hydrogen target during the cooling test done last night.
The temperature of the heat shield (green line) and the cell (blue line) increased while it went the minimum values at once.
In addition to the overall behaviour, a narrow peak was found (peak,png) in the cell temperature which anti-correlate to that of the heat shield. We consider
Fixed, e755, Wed Jun 20 16:45:00 2018, Cherry Mx Team, TARGET, Hardware, 3-alpha, Cryo target is filled targefilled.png
We dont see any alpha in detector 1-6m but we see them in detector 7-8.

Fixed, e755, Thu Jun 21 07:16:51 2018, daisuke, RUN, General, 3-alpha, RUN0039 three alpha source calibration MUST2 2018-06-21_run0039_01.png2018-06-21_run0039_02.png2018-06-21_run0039_03.png2018-06-21_run0039_04.png
alpha source run over night. 
Fixed, e755, Thu Jun 21 08:30:48 2018, shumpei, daisuke, RUN, General, 3-alpha, RUN0040 8 MeV source run with liquid hydrogen 2018-06-21_run0040_04.png2018-06-21_run0040_03.png2018-06-21_run0040_02.png2018-06-21_run0040_01.png
RUN 0040. started 7:23 am 
 
8 MeV source was set upstream at 0 degrees to confirm that the target is filled with liquid. The target has been cooled since 4 pm yesterday. From the
Fixed, e755, Thu Jun 21 09:16:01 2018, Kitamura, TARGET, Hardware, N/A, Vapor pressure isobutane.pngcf4.png
Vapor pressures of isobutane and CF4. The paramateres of the Antoine equation were taken from the following NIST
pages.
Fixed, e755, Thu Jun 21 16:08:32 2018, Valerian, MUST2, Hardware, N/A, Run 3045 : Calimero T1-4 X Calimero_T14X.png
[U][B]run 3045 :[/B][/U] 
start @ 15h35
stop  @ 15h59
Pinned, e755, Thu Jun 21 17:07:14 2018, Valerian, MUST2, General, N/A, run 3046 : Calimero T1-4Y Calimero_T14Y.png
[U]run 3046 :[/U] Calimero T1-4Y
start @ 16h28
stop @ 16h53
Fixed, e755, Thu Jun 21 18:52:42 2018, takeshi, TARGET, Hardware, N/A, target temperature entire.pngheatshield.pngcell.png
Here I attached the temperature graph which is daisuke discussed at the meeting.
Both the heat shield (blue line) and the cell (green) increase after the minimum at 8 hours.
They had a second minimum at 21 hours and now they are increasing.
Fixed, e755, Fri Jun 22 03:11:51 2018, takeshi, VACUUM, Hardware, N/A, the vacuum pressure and the target temperature M2CvsE.pngM2CvsA.png
We suspect the impurity of the vacuum causes the rebound behavior of the target temperature.
Here is the data of the vacuum level v.s. the target temperature as it increasing.
As Daisuke explained at the meeting, we are monitoring two point as temperature reference,  the cell (A) and the heat shield (E).
Fixed, e755, Fri Jun 22 11:14:01 2018, Valerian Pierre Adrien Fred Fairouz, MUST2, General, N/A, run 3061 Calimero T5-8X Calimero_T56X.png
[U][B]run 3061[/B][/U] Calimero T5-8X
Fixed, e755, Fri Jun 22 13:06:29 2018, daisuke, MECH, Hardware, N/A, Alpha source ladder instruction Photos_porte_source_E755_et_E738.pdf
Instruction to translate and rotate the ladder for the alpha sources (by Vincent).
Fixed, e755, Fri Jun 22 13:22:19 2018, daisuke, BEAM, Social, N/A, Beam time schedule Planning_Faisceaux_2018_run2.1.0.pdf
 
Fixed, e755, Fri Jun 22 13:45:22 2018, takeshi, TARGET, Hardware, N/A, target temperature status tamperature2206.pngheatshield2206.pngcell2206.png
I would report the temperature log of the target up to now.
We started cooling the target at 2:21 last night.
The attached file is the temperature graph. The black lines are the today and the other colors are for reference. The thicker line is the heat shield and
Fixed, e755, Fri Jun 22 16:57:27 2018, daisuke, OTHER, Social, N/A, Who is in GANIL? 
https://docs.google.com/spreadsheets/d/1jyfw2LT3RGfDY4bcN-9zepZoe2uE89b5CnF4tXzqzj8/edit#gid=0
Fixed, e755, Fri Jun 22 21:29:05 2018, Pierre Fairouz Adrien Valerian, CATS, General, N/A, Mask reconstruction mask1.pdfmask2.pdf
Mask reconstruction after adding the correction shift for CATS.
CATS1X = +1.2
CATS1Y = -0.1
Fixed, e755, Fri Jun 22 22:12:43 2018, daisuke, MECH, Hardware, N/A, positions, geometry and dimensions 2018-06-13_e738_setup.pdf
 
Fixed, e755, Fri Jun 22 22:14:30 2018, daisuke, MECH, Hardware, N/A, How to open the gate valve Procedure_d'ouverture_de_vanne_d'isolement.pdf
 
Pinned, e755, Fri Jun 22 22:15:45 2018, daisuke, MECH, Hardware, N/A, Geometrical survey report E755_Listing_DSSD_X_Y_Z_repère_géomètre.xlsxSTP-2018-E071_D6_E755_Sorlin_Suzuki.pdfE755_Listing_DSSD_X_Y_Z.pdf
 
Fixed, e755, Sat Jun 23 00:39:33 2018, takeshi, TARGET, Hardware, N/A, target temperature temperature2306.pngheatshield2306.pngcell2306.png
Here is the target temperature up to now. The black lines are today, and bule lines are reference.
The thicker line is for the heat shield and the thinner is for the cell.
Once we reached flat region at 15 hours, and but got a sudden increase of cell temperature at 19.5 hours.
Fixed, e755, Sat Jun 23 00:47:19 2018, Pierre Valerian, CATS, General, N/A, NEW GOOD mask reconstruction mask1.pdfmask2.pdf
New shift for CATS after fixing Z position of CATS detectors.

ConfigCATS
Fixed, e755, Sat Jun 23 01:55:34 2018, Louis, BEAM, General, CH2, Beam tunning  beam_tunnig23_06_1h_24m.png
Beam was tunned around 1am to center the beam on the target. On the picture, up is after tunning and down is before tunning
Fixed, e755, Sat Jun 23 02:28:03 2018, daisuke, louis, jean-charles, RUN, Software, N/A, RUN 63 (40Ca + liq. H) scalers and histograms 10x
 
Fixed, e755, Sat Jun 23 04:16:03 2018, Louis, OFFLINE, General, CH2, deltaE E dEE_noCalib_run0063.jpg
here a plot of energy loss in DSSD in function of energy in CsI. One can distinguish proton and alpha. Energy calibration of the CsI is needed to identify
clearly the tritons
Fixed, e755, Sat Jun 23 06:10:01 2018, shumpei, OFFLINE, Software, CH2, 40Ca(p,d)39 reaction tgt.pdfd.pdf40capd.pdfspectre_en_energie_39Ca.PNG
Quick off-line analysis for 40Ca(p,d)39 reaction is shown.
Used gate - target image and dE-E cut for deutron locus
Kinematics is also shown. Energy is shifted but seems good.
, e755, Sat Jun 23 06:16:25 2018, Louis, OFFLINE, , ,  
 
Fixed, e755, Sat Jun 23 14:07:40 2018, Valerian Fairouz, RUN, General, N/A, Problem from Narval narval_crash_problem.png
Narval actors went crazy see joined images

run 75 must be trash as it created 18 files of 4Go in 10 minutes : 
Fixed, e755, Sat Jun 23 17:07:35 2018, daisuke, RUN, Social, Cryo-LH2, Run summary 40Ca(p,t) 

total 698 min or 11.6 hours (RUN 63 to 81)
Fixed, e755, Sat Jun 23 18:01:58 2018, Valerian Maurycy, OFFLINE, General, Cryo-LH2, Kinematics Line ELab_Theta_2H.pdfELab_Theta_3H.pdfELab_Theta_3He.pdfELab_Theta_4He.pdf
Using Run 63-64 we drew Kinematics Lines.
Ongoing, e755, Sat Jun 23 19:10:23 2018, Nori, OFFLINE, General, Cryo-LH2,  
 
Fixed, e755, Sat Jun 23 19:41:49 2018, Valerian, OFFLINE, General, Cryo-LH2, De_E plot DE_E_run81.pdf
 
Fixed, e755, Sat Jun 23 19:23:19 2018, Nori, OFFLINE, General, Cryo-LH2, 40Ca(p,d) analysis 7x
Analysis of run0072 (two hours accumulation).

Attachment 1:
    Fixed, e755, Sat Jun 23 20:07:49 2018, Nori, OFFLINE, General, Cryo-LH2, 40Ca(p,d) analysis 
Order-of-magnitude estimate of the target thickness.

We have about 5000 counts of 40Ca(p,d)39Ca(g.s.) in an angular range of 10-30 degrees.
Fixed, e755, Sat Jun 23 20:09:00 2018, e755 - Louis, Valérie, RUN, General, Cryo-LH2, Summary of Runs 83 and 84 19x
CATS beam 1.7 10**5 /s
Run 84 start @ 19h54 stop @ 20h16 on problem with CO. 
the PCP said: Maybe 10 minutes of beam stop. Let's see.
Fixed, e755, Sat Jun 23 20:56:15 2018, e755 - Louis, Valérie, RUN, General, Cryo-LH2, Run 85 Run85_scalersAt20h48.pngrun85Catsprofiles.png
CATS beam 1.8 10**5 /s
Beam back at 20h46
Run 85 start @ 20h46 stop @21h02
Fixed, e755, Sat Jun 23 21:17:03 2018, e755 - Louis, Daisuke,Shumpei, Takeshi, Nori, Valérie, RUN, General, Cryo-LH2, Run 86-Test measurement, (heating target) run86Scalersat21h17.png
CATS beam 1.8 10**5 /s
 Target temperature increasing during the run. 
Run 86 start @ 21h05 stop @21h41
Fixed, e755, Sat Jun 23 21:51:04 2018, e755 - Louis, Daisuke,Shumpei, Takeshi, Nori, Valérie, RUN, General, Cryo-LH2, Run 87-Empty target measurement run87Scalersat21h50.png
CATS beam 1.8 10**5 /s
  
Run 87 start @ 21h42 stop @ 21h52
Fixed, e755, Sat Jun 23 21:52:01 2018, takeshi, TARGET, Hardware, N/A, evaporation of the H2 target evapolation2206.png
Here is the temperature log when we evaporate the liquid H2 by heater.
The black line is what we call sensor A, which we monitor usually, and the red line is sensor B, which is the closest sensor to the target window.
Fixed, e755, Sat Jun 23 22:03:17 2018, takeshi, TARGET, Hardware, , temperasure log of the target temperature2306_3.pngheatshield2306_3.pngcell2306_3.png
I would report the temperature log of the liquid hydrogen target.
We consider it was liquid during the beam time up to now by the beam profile data on the target.
Fixed, e755, Sat Jun 23 22:08:43 2018, e755 - Louis, Daisuke,Shumpei, Takeshi, Nori, Valérie, RUN, General, Cryo-LH2, Run 88-Empty target measurement 10x
CATS beam 1.8 10**5 /s
  
Run 88 start @ 22h07 
Fixed, e755, Sat Jun 23 22:42:33 2018, e755 - Louis, Valérie, MUST2, Hardware, Cryo-LH2, Status of MUST2 telescopes 23 june 18 TempMuvi1MufeeXTel1.pngTempMuvi2MufeeYTel6.pngTempMuvi2MufeeXTel6.pngTempMuvi2MufeeXTel8.pngRun88scalersAt23hORDI.png
Temperatures on the Mufeex-Y cards:

Temperature set on the regulator -4°C. 
Fixed, e755, Sat Jun 23 22:47:21 2018, daisuke, TARGET, Hardware, N/A, Target images for Liq. H and empty target run85Catsprofiles.pngRun88emptyT_CATSbeam.png
Attachment 1: RUN 85 with liq.H
Attachment 2: RUN 88 with empty cell. 
Fixed, e755, Sat Jun 23 23:31:12 2018, e755 - Louis, Valérie, RUN, General, Cryo-LH2, Run 89-Empty target measurement Run89CatsProfile.png
CATS beam 1.5 10**5 /s
  
Run 89 start @ 23h29 
Fixed, e755, Sat Jun 23 23:38:32 2018, takeshi, RUN, Social, Cryo-LH2, run summary for 40Ca beam 
run 63-85, total 15.4 hours data was taken

start                           stop          duration  runname
Fixed, e755, Sun Jun 24 09:48:46 2018, Francois, BEAM, General, , No beam 
9H10: D5 stopped at 9H10. We asked for the beam.

9H48: Still no beam.  There is a problem with the beam current limits set in the accelerator. They have to change it from 40 nAe between CO1 and CSS1 
Fixed, e755, Sun Jun 24 12:10:35 2018, takeshi, TARGET, Hardware, , target temperature during warming up warming2406.png
I would share the temperature log of the target cell during warming it up.
The thick line is the heat shield and the thin line is the cell. 
The heat shield may takes 2 hours to reach 200 K and 6 hours for 270K.
Fixed, e755, Sun Jun 24 13:20:51 2018, takeshi, TARGET, Hardware, N/A, start target cooling cooling.png
We started cooling the target cell at 13h03.
It would take 4 - 5 hours to cooling the cell enough low for liquifying hydrogen.
 
Fixed, e755, Sun Jun 24 13:25:30 2018, Fred, valérian, daisuke, DAQ, Software, N/A, Scalers to be recorded run_0092_scaler_record_check.png
The U2M scaler data cannot be recorded to the data in the current version of Narval. So there were no scaler data during the measurement of 40Ca.

To resolve the situation, we added register parameters for specified channels of U2M. This allows us to record the counts of a given channel at each event.
Fixed, e755, Sun Jun 24 16:11:38 2018, daisuke, ONLINE, Software, N/A, Automated screenshot screenshot_2018-06-24_18h06m11s.pngscreenshot.sh
automated screenshot commands

shot: Capture the window selected by the mouse
Fixed, e755, Sun Jun 24 19:51:09 2018, Faïrouz, daisuke, MUST2, Software, N/A, MUST2 threshold from 1 MeV to 0.4 MeV das_2018-06-24_19h33m36s.pngdas_2018-06-24_19h49m33s.png
It was found that the energy threshold of the strips was as high as 1 MeV. This threshold setting was chosen for the calibration and was never set back
to the nominal threshold (0.4 MeV) for experiments.
Fixed, e755, Sun Jun 24 21:12:25 2018, e755- Valérie, DAQ, Hardware, , GMT chronogrammes GMTchronoMaster.pngGMTslaveChrono.png
Since Run 103 
MASTER FAG 100 ns
SLAVE 100 ns
Fixed, e755, Sun Jun 24 21:36:24 2018, e755-Daisuke, Louis, Olivier, Pierre, Valérie, RUN, General, Cryo-empty, Summary of the evening runs 101-105 
 run 101 Trigger Cats 2 div; div =1
Run 102
run 103
Fixed, e755, Sun Jun 24 22:13:29 2018, takeshi, TARGET, Hardware, N/A, temperature log of the target temperature2406.pngliquiefy2406.png
We liquefied the hydrogen target around 22:00. 
I would share the temperature log of the liquid hydrogen target during cooling and liquifying.
Black line is today and the other colors represent the references , The thicker liens are the heat shield and the thinner lines are the cell.
Fixed, e755, Sun Jun 24 22:13:30 2018, valérie, daisuke, RUN, General, Cryo-empty, RUN 106 empty target run 6x
 Run 106 Trigger: MUST2 all
start @ 21h31; stop @21h44
e748 Exxx 168154021 24 juin 21:44 /data/e748X/e755/acquisition/run/run_0106.dat.24-06-18_21h31m26s
Fixed, e755, Sun Jun 24 22:18:50 2018, Daisuke, Louis, Olivier, Valérie, RUN, General, Cryo-LH2, RUN 107  Run107scalersAt22h17.pngTriggerMMandCATSRun107.pngTriggerMM2Run107ProfileCats.png
run 107 start@ 22h15; stop@ 22h37
e748 Exxx  689278077 24 juin  22:37 /data/e748X/e755/acquisition/run/run_0107.dat.24-06-18_22h15m16s
Fixed, e755, Sun Jun 24 22:25:53 2018, shumpei, MUST2, Hardware, Cryo-empty, threshold for DSSDs of MUST2 pid_threshold.pdf
Threshold of DSSDs were changed (see entry 638).
Run 106 was analyzed and now the threshold seems about 0.4 MeV.
Fixed, e755, Sun Jun 24 22:26:46 2018, Daisuke, Louis, Olivier, Valérie, MUST2, General, Cryo-LH2, HV on MUST2, currents, CATS HVonMUST2mm1to4.pngHVonMUST2mm5to8andCats.png
NB: SiLi1 T7 has tripped during the evening (since Run 104)
It should be put on again (better to increase the HV during a beam stop) 
Fixed, e755, Sun Jun 24 22:45:41 2018, Daisuke, Fairouz, Louis, Olivier, Valérie, RUN, General, Cryo-LH2, RUN 108 Run108_TriggersCats.pngRun108_scalersAt22h43.png
Run 108 24 june start @ 22h38 stop@ 22h54
e748 Exxx   10068143 24 juin  22:54 /data/e748X/e755/acquisition/run/run_0108.dat.24-06-18_22h38m15s
Triggers Cats 1 and Cats2 DIV= 3.10**4
Fixed, e755, Sun Jun 24 23:07:45 2018, Daisuke, Fairouz, Louis, Olivier, Valérie, RUN, General, Cryo-LH2, RUN 109 Run109_ScalersAt22h56.pngRun109_CaTSslits10-8.5mm_W1.4kV.pngRun109_CaTSslitsFV43at10mm_W2kV.pngRun109filledTargetOKat16KprojBinY.pngRun109_ProfileCatsTargetFrame.png
Run 109 24 june start @ 22h54 stop@ 23h14
e748 Exxx    9723325 24 juin  23:14 /data/e748X/e755/acquisition/run/run_0109.dat.24-06-18_22h54m26s
Triggers Cats 1 and Cats2 DIV= 3.10**4
Fixed, e755, Sun Jun 24 23:17:01 2018, Daisuke, Fairouz, Olivier, Valérie, RUN, General, Cryo-LH2, RUN 110 Run110-projCATS2-CAVIAR.png
Run 110 24 june start @  23h15 stop @ 23h56 
e748 Exxx 1339167483 24 juin  23:56 /data/e748X/e755/acquisition/run/run_0110.dat.24-06-18_23h14m53s
All Triggers: MUST2 and Cats 1 and Cats2 DIV= 3.10**4
Fixed, e755, Mon Jun 25 00:13:48 2018, Valérie +Lise team: Jean-Charles+Target: Takeshi, RUN, General, Cryo-LH2, RUN 111 16x
Run 111  25th June start @ 0h stop @1h13

e748 Exxx 3590054877 25 juin  01:14 /data/e748X/e755/acquisition/run/run_0111.dat.24-06-18_23h59m52s
Fixed, e755, Mon Jun 25 01:17:47 2018, Valérie +Lise team: Jean-Charles+Target: Takeshi, RUN, General, Cryo-LH2, RUN 112 6x
Run 112 25th June start @ 1h14 stop @ 2h34
e748 Exxx 3769078581 25 juin  02:34 /data/e748X/e755/acquisition/run/run_0112.dat.25-06-18_01h14m03s
 Target seems to be still ok and filled! see CATS plot on target
Fixed, e755, Mon Jun 25 02:34:30 2018, Valérie +Target: Takeshi, RUN, General, Cryo-LH2, RUN 113 11x
Run 113 25th June start @ 2h34 stop @ 3h57
e748 Exxx 3957925525 25 juin  03:57 /data/e748X/e755/acquisition/run/run_0113.dat.25-06-18_02h34m10s
  
Fixed, e755, Mon Jun 25 03:14:38 2018, e755- Valérie, MUST2, Hardware, Cryo-LH2, HV on MUST2, currents, CATS 
HV and currents on DSSDs and SiLi at 3h20

Telescopes T
Fixed, e755, Mon Jun 25 03:58:22 2018, Valérie +Target: Takeshi, RUN, General, Cryo-LH2, RUN 114 9x
Run 114 25th June start @ 3h57 stop @5h34

 e748 Exxx 4015552641 25 juin  05:34 /data/e748X/e755/acquisition/run/run_0114.dat.25-06-18_03h57m34s
Fixed, e755, Mon Jun 25 05:34:53 2018, Valérie +Target: Takeshi, RUN, General, Cryo-LH2, RUNS 115, 115.1 and 116 Run115ScalersAt5h37.pngRun115ScalersAt6h39.pngRun115b1_scalersAt7h20.pngRun115b1BeamProfile.pngRun116_ScalersAt8h26.png
Run 115 25th June start @ 5h34 stop@6h57
 e748 Exxx 4190541701 25 juin  06:57 /data/e748X/e755/acquisition/run/run_0115.dat.25-06-18_05h34m33s
  -------------------------------------------------------------------------------
Fixed, e755, Mon Jun 25 07:41:54 2018, e755- Valérie, MUST2, Hardware, Cryo-LH2, SUMMARY-Missing strips MUST2 Run116_MMimpacts.pngRun116_Mm1toMM4StrXYE.png
 
Telescopes MM1 to MM8, XY ET missing strips
----------------------------------------------------
Fixed, e755, Mon Jun 25 08:38:34 2018, e755 Louis Francois Marlene, OFFLINE, General, Cryo-LH2, 38Ca(p,d)37Ca 38Capd_Run_110.pdf38Capd_Run_110_deE.pdf
Here Kine;atics line for th 38Ca(p,d)37Ca Channel from run 110
Fixed, e755, Mon Jun 25 10:42:47 2018, daisuke, TARGET, Software, Cryo-empty, RUN 106 (38Ca with empty target) S/N 7x
p, d, t ratio of events from the target frame and from the target aperture (covered by Havar 6.5 micron and Mylar 2 micron)

R(d/p) = 0.3 (frame)  0.14 (target)
Fixed, e755, Mon Jun 25 11:12:40 2018, Marlene, Louis, RUN, General, Cryo-LH2, Run 117, 38Ca, Target filled 6x
Run 117 started @ 10h54
stopped @ 11h32 to enter in the room
Fixed, e755, Mon Jun 25 13:40:41 2018, Marlene, Louis, RUN, General, Cryo-LH2, RUN 118 CAVIAR setting 
run 118 started @ 13h13
stopped @ 13h43
Fixed, e755, Mon Jun 25 14:04:17 2018, Marlene, Louis, RUN, General, Cryo-LH2, RUN 119 to 121 
Test for CAVIAR and CHIO:

run 119 with two 1/15 reductors   13h54 to 14h01
Fixed, e755, Mon Jun 25 16:09:24 2018, Benoit Louis, RUN, General, Cryo-LH2, Beam and CHIO tunning Run126_deTOF.pngRun127_BeamProfil.pngRun126_Scaler.png
During run 126:
Beam was tuned to be centered and homogeneous in the target
efficiency and resolution of the CHIO was improved
Fixed, e755, Mon Jun 25 17:23:49 2018, Cherry Mx Team, CATS, General, Cryo-LH2, Confirmation of CATS reconsctruction 
Gating on T1 to T4 and looking at the the CATS reconstruction on Target we confirm that;
  - CATS is correlated to MUST
  - Telescope Position matches CATS Position, so Telescope numerotation is correct and there is no inversion in CATS.
Fixed, e755, Mon Jun 25 17:27:59 2018, Cherry Mx Team, CATS, General, Cryo-LH2, Confirmation of CATS reconsctruction CATS_TELESCOPE.pngCATS_TELESCOPE_M2.png
Gating on T1 to T4 and looking at the the CATS reconstruction on Target we confirm that;
  - CATS is correlated to MUST
  - Telescope Position matches CATS Position, so Telescope numerotation is correct and there is no inversion in CATS.
Fixed, e755, Mon Jun 25 11:23:03 2018, daisuke, TARGET, Hardware, Cryo-LH2, Liquid hydrogen target logger screenshot_2018-06-25_11.17.25.png
 
    Fixed, e755, Mon Jun 25 17:28:03 2018, Nori, TARGET, Hardware, Cryo-LH2, Liquid hydrogen target logger screenshot_2018-06-25_17.20.41.pngscreenshot_2018-06-25_20.56.47.png
There was a sudden increase of the temperature at 4pm. Fortunately the cell is still filled with liquid.
Fixed, e755, Mon Jun 25 17:31:27 2018, daisuke, benoït, TARGET, Software, Cryo-LH2, RUN 127 (Still filled with liquid? test with Wien filter) Run127_BeamProfil.pngvisu_2018-06-25_16h55m02s.pngvisu_2018-06-25_17h01m48s.pngRun127_target_frame_projection.png
Beam spot is now too small to see the cell frames. Moved the beam spot down and up by using the Wien filter. It is not conclusive, but the gap between the
cell frame and the liquid surface is increasingly apart toward outside in X. It is possible that liquid filling  the upper part of the cell has been evaporated.
Should carefully monitor the cell temperature and the beam image.
Fixed, e755, Mon Jun 25 17:40:44 2018, daisuke, benoït, RUN, Software, Cryo-LH2, RUN 128 (Still filled with liquid?) 10x
 
Fixed, e755, Mon Jun 25 19:59:55 2018, marlène, freddy, benoït, MUST2, Software, N/A, CsI disabled in MUVI/DAS das_2018-06-25_19h59m19s.png
 
Fixed, e755, Mon Jun 25 20:01:07 2018, olivier, daisuke, DAQ, Hardware, N/A, Another deat time scaler 
After RUN 128, we entered D6 to add another deat time measuring pulses to U2M channel 9. This is supposed to correctly measure dead time both for MUVI1
in the master and MUVI2 in the slave. For detail, see page 85 in the logbook.
Fixed, e755, Mon Jun 25 20:10:21 2018, daisuke, benoît, RUN, General, Cryo-LH2, RUN 130 scaler_2018-06-25_20h10m53s.pngvisu_2018-06-25_20h09m45s.png
 
Fixed, e755, Mon Jun 25 20:51:28 2018, daisuke, benoît, RUN, General, Cryo-LH2, RUN 132 9x
Previous run (RUN 131), MUST2 threshold was raised to 500 keV to see how the dead time (DESC/ORDD) is improved (found not effective). The threshold was
set back to 400 keV.
Fixed, e755, Mon Jun 25 22:40:38 2018, daisuke, benoît, RUN, General, Cryo-LH2, Run 133 6x
same as before
Fixed, e755, Mon Jun 25 23:17:56 2018, Nori, MUST2, General, Cryo-LH2, DSSD multiplicity run0128_simult.pngrun0128_allstripsfired.pngAll_strip_fired.png
Data analysis of run0128 (38Ca physics run). The multiplicity distribution of DSSD x-strips is shown in
Attachment 1. The second peak centered at around 128, which is the number of strips of one detector, corresponds
to events where beam-like heavy ions are hitting the detector.
Fixed, e755, Tue Jun 26 00:09:40 2018, Pierre, Shumpei, RUN, General, Cryo-LH2, RUN 134 scaler_2018-06-26_00h08m24s.pngvisu_2018-06-26_00h08m16s.pngvisu_2018-06-26_00h42m01s.png
Start: 26/06 at 00h05
Stop: 00h40 for PCP to improve beam tuning 
Fixed, e755, Tue Jun 26 01:02:42 2018, Pierre, Shumpei, RUN, General, Cryo-LH2, RUN 135 scaler_2018-06-26_01h02m13s.pngvisu_2018-06-26_01h04m13s.png
start: 01h02
stop: 01h39
Trigger: MM+CATS DIV
Fixed, e755, Tue Jun 26 01:46:56 2018, Pierre, Shumpei, RUN, General, Cryo-LH2, RUN 136 scaler_2018-06-26_01h44m28s.pngvisu_2018-06-26_01h47m09s.pngvisu_2018-06-26_02h53m01s.png
start: 01h41
stop: 03h37
Fixed, e755, Tue Jun 26 03:40:15 2018, Pierre, Shumpei, RUN, General, Cryo-LH2, RUN 137 scaler_2018-06-26_03h38m54s.pngvisu_2018-06-26_03h42m20s.pngvisu_2018-06-26_04h05m34s.png
start: 03h38
stop: 05h30
Fixed, e755, Tue Jun 26 05:32:35 2018, Pierre, Shumpei, RUN, General, Cryo-LH2, RUN 138 scaler_2018-06-26_05h32m06s.pngvisu_2018-06-26_05h36m34s.png
start: 05h31
stop: 07h23
Fixed, e755, Tue Jun 26 05:40:52 2018, Pierre, OFFLINE, General, Cryo-LH2, Kinematic lines and Ex for 38Ca(p,d) and 38Ca(p,t) kine_38Capd_run0128.pdfkine_38Capt.pdf
-> 38Ca(p,d) uses run 128 

-> 38Ca(p,t) uses run from 128 up to 136
Fixed, e755, Tue Jun 26 06:55:51 2018, shumpei, OFFLINE, Software, Cryo-LH2, 38Ca (p,t) 36Ca fig.pdf
Run 111 - 134 (almost 1 day) data was analyzed.

38Ca (p,t) 36 Ca was reconstructed only from Telescope 3.

About 500 events for most likely 36 Ca g.s.
Fixed, e755, Tue Jun 26 07:24:59 2018, Pierre, Shumpei, Yorick, Valérie, RUN, General, Cryo-LH2, RUN 139 scaler_2018-06-26_07h23m43s.pngvisu_2018-06-26_07h26m37s.pngrun139_scalersAt8h42.png
start: 07h23
stop: 8h52
748 Exxx 3003199093 26 juin  08:52 /data/e748X/e755/acquisition/run/run_0139.dat.26-06-18_07h22m11s
Fixed, e755, Tue Jun 26 08:13:02 2018, e755-Valérie, RUN, General, Cryo-LH2, data Run summary 25+26 june 
 RUNS since 25 june pm till 26th june 7am

r--r--r-- 1 e748 Exxx  626093289 25 juin  14:38 /data/e748X/e755/acquisition/run/run_0123.dat.25-06-18_14h18m37s
Fixed, e755, Tue Jun 26 08:15:29 2018, e755 Valérie, MUST2, General, Cryo-LH2, MUST2 configuration summary MUST2thresholdsMUVI1tel1.pngrun139_CsIpadsMUST2.png
MUST2 summary 26th June 8am

MUST2 thresholds 402 keV
Fixed, e755, Tue Jun 26 09:01:23 2018, Daisuke, Takeshi, Yorick, Valérie, RUN, General, Cryo-LH2, RUN 140 21x
Run 140 start: 8h55 ;  stop: 9h59
748 Exxx 3348489513 26 juin  09:59 /data/e748X/e755/acquisition/run/run_0140.dat.26-06-18_08h55m32s
 The Csi Mate were put on the trigger again "ENABLE" in the DAS. see snapshot DAS_MUVIenableMateCsI.png
Fixed, e755, Tue Jun 26 09:28:10 2018, takeshi, TARGET, Hardware, N/A, temperature of the target temperature2606.pngcell2606.pngscreenshot_2018-06-26_10.30.45.pngscreenshot_2018-06-26_17.49.29.png
<p>Here is the temperature log of the target up to now. The black lines are today, The thicker line is the cell window this time, not the heat shield and
the thinner line is the cell (same as previous). Though the temperature is rather high, it seems stable. We started cooling 13h00 24th and about 40 hours
has passed since that.</p>
Fixed, e755, Tue Jun 26 09:52:35 2018, e755 Valérie, RUN, General, Cryo-LH2, Summary of MUST2 plots during RUN 140 Run140_MM1toMM4StrXYE.pngRun140_MM5toMM8StrXYE.pngRun140_MMCsiIpads.pngRun140_MMImpacts.png
 
 The Csi Mate were put on the trigger again "ENABLE" in the DAS. see snapshot DAS_MUVIenableMateCsI.png entry id=685
Fixed, e755, Tue Jun 26 10:03:29 2018, Adrien, Freddy, Marlène, Yorick, Valérie, target team: Daisuke, Takeshi, RUN, General, Cryo-LH2, RUN 141 Run141_scalersAt10h.pngRun141_SiLiT7andT8.pngRun141_scalersAt10h55.pngRun141_scalersAt10h56.pngRun141_scalersAt10h57.png
Run 141 26th june start@ 9h59 stop: 11h12
e748 Exxx 3449521865 26 juin  11:12 /data/e748X/e755/acquisition/run/run_0141.dat.26-06-18_09h59m57s
Fixed, e755, Tue Jun 26 11:47:16 2018, NPTeam, OFFLINE, General, Cryo-LH2, 38Ca(p,d)37Ca with zero deg gate 37Ca_getzero.pdf
We did a gate on IC_E:PlasticQ on particle with same Z as the beam.

We obtain the 37Ca bound state spectrum. The spectrum is coherent with known state at 0 1.6 2.9 MeV (green thick line) and no count above Sp (dashed red
Fixed, e755, Tue Jun 26 12:06:41 2018, Marlène, Yorick, Valérie, RUN, General, Cryo-LH2, RUN 142 ChangeThresholdsAllMateXMUST2.pngRun142_scalersAt11h17.png
Run 142 26th june start@ 11h15 ; stop @11h27
 
e748 Exxx  492791993 26 juin  11:27 /data/e748X/e755/acquisition/run/run_0142.dat.26-06-18_11h15m39s
Fixed, e755, Tue Jun 26 12:18:08 2018, Marlène, Yorick, Valérie, RUN, General, Cryo-LH2, RUN 143 Run143scalersAt11h32.pngMMthresSilIMate17beforRun143PROB.pngMMthresSilIMate17run143okSiLi.png
Run 143 -- 26th June start@ 11h30  ; stop @ 11h39 
 e748 Exxx  306151179 26 juin  11:39 /data/e748X/e755/acquisition/run/run_0143.dat.26-06-18_11h30m28s
 
Fixed, e755, Tue Jun 26 12:22:56 2018, Marlène, Yorick, Valérie, RUN, General, Cryo-LH2, RUN 144 6x
Run 144 -- 26th June start@ 11h51  ; stop @ 13h04
  
Trigger: all MM + CATS DIV
Fixed, e755, Tue Jun 26 13:37:44 2018, Louis, RUN, General, Cryo-LH2, RUN 145 run_145_CATScal.pngrun_145_CATSpos.pngrun_145_scalers.png
Run 145 -- 26th June start@ 13h07 ; stop @ 13h53
e748 Exxx 2239017281 26 juin  13:53 /data/e748X/e755/acquisition/run/run_0145.dat.26-06-18_13h06m30s
Trigger: all MM + CATS DIV
Fixed, e755, Tue Jun 26 13:41:02 2018, NPTeam, MUST2, General, N/A, Change in strips firing firing_strips_X.pngfiring_strips_Y.png
After changing in the MUST2 the range of pedestal suppression (Ex < 8192 are rejected and Ey > 8192 are rejected). we can clearly see that there are no
more firing of all the strips for X and Y.
Fixed, e755, Tue Jun 26 14:29:36 2018, Daisuke, Louis, Olivier, Valérie, RUN, General, Cryo-LH2, RUN 146 
Run 146 -- 26th June start@ 14h07 stop @14h26
e748 Exxx  844513015 26 juin  14:26 /data/e748X/e755/acquisition/run/run_0146.dat.26-06-18_14h07m32s
 The run was stopped: no beam due to the source disjonction.
Pinned, e755, Tue Jun 26 14:36:55 2018, NPteam, OFFLINE, General, , 36Ca(p,t)36Ca analysis with zero degree gate kine_38Capt_zrodeg_gated.pdfkine_38Capt_zrodeg_gatedZ19.pdf
Here is an update of the analysis results for the 36Ca(p,t)36Ca channel.

Run concerned: 128 to 137
Fixed, e755, Tue Jun 26 14:39:52 2018, Charles H, Fred, Valérie, RUN, General, Cryo-LH2, RUN 147 6x
Run 147 -- 26th June start@ 14h34

We make some checkings of DT during the beam stop due to the source disjonction.
Fixed, e755, Tue Jun 26 16:38:31 2018, daisuke, thomas, RUN, General, Cryo-LH2, RUN 148 38Ca beam is back 20x
 
Fixed, e755, Tue Jun 26 16:40:12 2018, Adrien, OFFLINE, Software, Cryo-LH2, Offline analysis of p,t 38Capt_zero.pdf
Looking at the pt reaction and gating on z = 20 (solid blue) and z=19 (hashed orange) we see a total of three states.
Fixed, e755, Tue Jun 26 18:28:45 2018, Nori, OFFLINE, General, Cryo-LH2, 37K,36Ar(p,t) run0128_0146_37K.pngrun0128_0146_36Ar.png
Offline analysis of run0128-0146.

Cuts: tritons, target aperture, beam, and multiplicity=1. Zero-degree infomation was not used.
Fixed, e755, Tue Jun 26 18:41:59 2018, e755 Valérie, RUN, General, Cryo-LH2, DAS save Summary of MUST2 conditions -26 june 
The DAS configuration was saved under e755.das and .e755_Exp26juin18Mmthreshd.das at 18h40 on June 26th.
Main changes in the DAS on 26 JUNE were:
 
Pinned, e755, Tue Jun 26 18:43:35 2018, Valerian, DAQ, General, N/A, In case of a data acqusition crash  
[CODE]If the acquisition crash :  

In the acquisition terminal : 
Fixed, e755, Tue Jun 26 20:33:17 2018, daisuke, TARGET, Hardware, Cryo-LH2, Liquid hydrogen target logger screenshot_2018-06-26_20.31.03.png
 
Fixed, e755, Wed Jun 27 01:14:54 2018, takeshi, RUN, General, N/A, online run summary 
I made a run summary up to now in the google spreadsheet.
You can see it on
https://docs.google.com/spreadsheets/d/1yErcQcrXPdJjEOfUd9D9KPWWkWQpw5kX4wFze6vwij4/edit?usp=sharing
Fixed, e755, Wed Jun 27 01:34:28 2018, Freddy Louis, RUN, General, Cryo-LH2, run153 12x
RUN 153

started @ 1h26  stopped at 3h20
Fixed, e755, Wed Jun 27 03:29:32 2018, Freddy Louis, RUN, General, Cryo-LH2, RUN 154 Run154_scaler.pngRun154_scaler_stop.pngRun154_pos.png
RUN 154
started @ 3h21    stopped @ 5h16
Fixed, e755, Wed Jun 27 04:12:57 2018, Freddy, Louis, OFFLINE, General, , Summary 38Ca(p,t) - Run 128 to 152 kine_38Capt_zrodeg_r128_152.pdfkine_38Capt_zrodeg_r128_152_T1.pdfkine_38Capt_zrodeg_r128_152_T3.pdfkine_38Capt_zrodeg_r128_152_telescope.pdf
Here are some plot summarizing the analysis status on the 38Ca(p,t) channel.

Run concerned: 128-152 (from 25/06 @ 17h11 to 26/06 @ 22h43)
Fixed, e755, Wed Jun 27 04:46:00 2018, Freddy, Louis, OFFLINE, General, , Summary 36Ar(p,t) - Run 128 to 152  kine_36Arpt_zrodeg_gatedZ18.pdfkine_36Arpt_zrodeg_gatedZ18_r128_152_T1.pdfkine_36Arpt_zrodeg_gatedZ18_r128_152_telescope.pdf
Here are some plot summarizing the analysis status on the 36Ar(p,t) similar method as in the previous entry:

Run concerned: 128-152 (from 25/06 @ 17h11 to 26/06 @ 22h43)
Fixed, e755, Wed Jun 27 05:20:22 2018, Freddy Louis, RUN, General, Cryo-LH2, RUN 155 Run155_pos.pngRun155_scaler.pngRun155_scaler_stop.png
RUN 155
started @ 5h16
stoppd at 7h19
Fixed, e755, Wed Jun 27 05:57:49 2018, takeshi, TARGET, General, Cryo-LH2, liquid hydrogen target temperature log target2706.png
It seems stable.
We liquified H2 around 22:00 24th (10 hours in the plot), so the target kept liquefying about 55 hours at 6:00 27th.   
 
Fixed, e755, Wed Jun 27 07:23:41 2018, Freddy Louis, RUN, General, Cryo-LH2, RUN 156 Run156_scaler.png
RUN 156
start at 7h17
Fixed, e755, Wed Jun 27 09:26:32 2018, daisuke, TARGET, Hardware, Cryo-LH2, Liquid hydrogen target logger (end of 38Ca) screenshot_2018-06-27_09.24.30.png
 
Fixed, e755, Wed Jun 27 09:49:37 2018, gib, RUN, General, Cryo-LH2, RUN 155 visu_2018-06-27_09h50m34s.pngvisu_2018-06-27_09h51m31s.pngvisu_2018-06-27_09h51m43s.png
run 156 for ref. LH2 empty next
Fixed, e755, Wed Jun 27 10:08:41 2018, gib, RUN, General, Cryo-empty, RUN 157 : empty target 17x
 
Fixed, e755, Wed Jun 27 10:15:36 2018, takeshi, RUN, General, Cryo-LH2, run summary for 38Ca + liq. H2 
Here is the summary of the measurement of 38Ca + liq H2 setting.
We obtain 49.45-hour data acquisition time, which contains 1.4 * 10^6 CATS DIV triggered event. 
The CATS DIV factor is 30000 for each CATS, so we can estimate the "gated beam rate", the beam rate including dead time of the DAQ, was 1.2 * 10^5 cps.
Fixed, e755, Wed Jun 27 11:38:09 2018, gib, OTHER, General, Cryo-empty, end of empty run. Now tuning for 36Ca visu_2018-06-27_12h28m12s.pngvisu_2018-06-27_12h28m20s.png
 
Fixed, e755, Wed Jun 27 16:03:26 2018, Valerian, OFFLINE, General, Cryo-LH2, Status on 38Ca pt 38Ca_pt_Canvas.pdf
 
Ongoing, e738, Wed Jun 27 17:42:14 2018, daisuke, OTHER, General, N/A, Toward E738 2018-06-13_e738_setup.pdf2018-06-27_e738_chio_energy_loss.pdf2018-06-27_e738_light_tof.pdfpt_sim_phase_plot_7c_t.pdfpt_sim_phase_plot_8c_d.pdf
 
Fixed, e755, Wed Jun 27 17:46:55 2018, e755 Daisuke, Olivier, Nori, Valérie, RUN, General, Cryo-empty, Run 158 Beam tuning for 36Ca Run158TrajectoriesWien1kV.pngRun158_trajectoriesWien5kV.pngRun158_trajectoriesWien5kVok.png
At 17h20 the beam was back in D6, ready for tuning by the LISE team, Christelle, Jean-Charles and Omar.
 
Run 158 start @ 18h06 stop@18h22
Fixed, e755, Wed Jun 27 18:34:31 2018, NPTeam, OFFLINE, General, Cryo-LH2, Update on the offline Analysis for 38Ca pt run 128-156 kine_38Capt_zrodeg_r128_156_telescope.pdfkine_38Capt_zrodeg_r128_156.pdf
 
Fixed, e755, Wed Jun 27 18:42:09 2018, e755 Daisuke, Olivier, Valérie, RUN, General, Cryo-empty, RUN 159 New input in GMT trigger +scalers Run159ICDEtacatsHf.pngRun159ICDEtacatsHf_Wien100kV74kV.pngRun159Trajectories_Wien100kV74kV.pngRun159_GMTalltriggerINewN12.png
Change of the GMT Trigger:
New entry IN12 corresponding to the CATS2 with no division.
This input is taken from the output of the  bidiv of CATS1 "N" (duplicating the entry CATS2) 
Fixed, e755, Wed Jun 27 19:26:13 2018, e755 Daisuke, Olivier, Pierre, Valérie, RUN, General, Cryo-empty, Run 160 -36Ca Run160CDEtacatsHf_Wien100kV74kV.png
TAC Cats2 HF delay of 30 ns is removed

Run 160 start@ 19h13 stop@ 19h23
Fixed, e755, Wed Jun 27 19:27:52 2018, e755 Daisuke, Olivier, Valérie, RUN, General, Cryo-empty, Run 161 -36Ca Run161CDEtacatsHf_noWienSlitsFH31at8mm.pngRun161_scalers.pngRun161EdeTOFcats.pngRun161TrajectoriesCats.pngRun161mmImpactswithSourcealpha.png

Run 161 start @ 19h25 stop@20h30
e748 Exxx 2411656699 27 juin  20:30 /data/e748X/e755/acquisition/run/run_0161.dat.27-06-18_19h25m55s
Fixed, e755, Wed Jun 27 20:39:44 2018, e755 Daisuke, Olivier, Valérie, RUN, General, Cryo-empty, Run 162-38Ca run162_Trajectories38Ca.pngRun162_ICDE1TcatsHF.png
TUNING OF 38Ca to be ready during the night, after the change of CO source at the machine between 21h ans 2am (maybe). 
LISE team: Omar K, Jean-Charles T.
Tuning made for 38Ca
Fixed, e755, Wed Jun 27 21:13:40 2018, e755 Daisuke, Olivier, edited by Valérie, RUN, General, Cryo-empty, Conditions for the night runs GECOIonizationTrigger.png
TUNING OF 38Ca to be ready during the night, after the change of CO source at the machine between 21h and 2am (maybe). 
LISE team: Omar K, Jean-Charles T. Tuning made for 38Ca at 21h for Run 162. 
 
Fixed, e755, Wed Jun 27 21:25:41 2018, takeshi, shunpei, TARGET, Hardware, Cryo-LH2, temperature log during liquefying temperature2706.png
Here is the temperature log before and during liquefying.
The temperature trend seems almost same as previous.
Fixed, e755, Wed Jun 27 22:11:20 2018, Pierre Louis, OFFLINE, General, Cryo-LH2, Offline analysis of 38Ca(p,d)37Ca 38Ca_pd_128_156.png38Ca_pd_128_156_kinematics.png
Here are some plot summarizing the analysis status on the 38Ca(p,d) channel.

Run concerned: 128-156 (from 25/06 @ 17h11 to 27/06 @ 7h03)
Fixed, e755, Thu Jun 28 00:59:55 2018, e755 Daisuke, Olivier, Pierre, Marlène, Valérie (: edit), RUN, General, Cryo-empty, Run 162-38Ca 8x
 38Ca  Beam at ~ 2. 10**5 pps
F62 +/- 11 mm
SLITS FH31 +/-5mm (moment)
Fixed, e755, Thu Jun 28 01:22:43 2018, Nori, BEAM, General, N/A, Brho2 scan for 36Ca brho2scan_1.pngbrho2scan_2.pngbrho2scan_3.png
We scanned Brho2 values so that the yield for 36Ca is maximized (LISE run0282-0284, F31 = +/-6 mm). 

Attachment 1:
Fixed, e755, Thu Jun 28 01:26:34 2018, daisuke, TARGET, Hardware, Cryo-LH2, Liquid hydrogen target logger 6x
 
Fixed, e755, Thu Jun 28 01:39:58 2018, Nori, BEAM, General, N/A, Discussion for 37Ca run281.pngScreen_Shot_2018-06-27_at_23.16.13.png
Offline analysis of LISE run0281. F31 = +/-0.6 mm, without wedge.
The number of counts of 37Ca was 900/50 = 18 times larger than 36Ca.
Comparing this result with a LISE++ simulation, if the Brho setting is optimized for 37Ca,
Fixed, e755, Thu Jun 28 08:20:54 2018, e755, RUN, General, Cryo-LH2, Summary Run 165-169 run169_tof_cats_hf.png
[U][B]Run 165[/B][/U][LIST]
[*] start: 2h12
[*] start: 3h11
Fixed, e755, Thu Jun 28 08:29:08 2018, Louis, CATS, General, Cryo-LH2, CATS-HF time shift during the night  6x
noticed that the time between CATS and HF shifted during the night.
run 164 to 169
Fixed, e755, Thu Jun 28 08:34:30 2018, Fredd, Louis, Daisuke, RUN, General, Cryo-LH2, Run 170 Run170_TCATSHF.pngscreenshot_2018-06-28_08h15m27s.pngRun170_Target.pngRun170_CATSRAWt.pngRun171_M2Energy.png
[U][B]Run 170[/B][/U][LIST]
[*] start: 8h07
[*] start: 
Fixed, e755, Thu Jun 28 10:38:58 2018, Freddy, MUST2, General, N/A, T4 Comparison of calibration runs Comparison_T4X_calibbeforeexp.pngComparison_T4Y_calibbeforeexp.png
Attached is a comparison of two calibrations performed before the experiment (2 weeks and one day before) for Telescope 4 (the one having a degraded resolution
in Ex on the offline). 
One can see that:[LIST]
Fixed, e755, Thu Jun 28 11:08:54 2018, Freddy, Louis, Valerian, RUN, General, 3-alpha, Intermediate alpha calibration T1234 Run171_M2_EX_RAW.pngRun171_M2_EY_RAW.png
Run 171

3alpha source in front of T1234
Fixed, e755, Thu Jun 28 13:53:28 2018, Freddy, Louis, Valerian, RUN, General, 3-alpha, Pedestal run + Alpha calibration with T4 at 80V 
[U][B]Run 172[/B][/U][LIST]
[*] Pedestal run on T1234
[/LIST]
Fixed, e755, Thu Jun 28 19:58:12 2018, shumpei, OTHER, General, N/A, Kinematics for the reactions kinematics.pdf
Kinematics for the reaction of E755 and E738 experiments are shown.
Fixed, e755, Fri Jun 29 00:59:15 2018, Louis, OFFLINE, General, Cryo-LH2, Analysis of run 63 to 89 in 40Ca(p,t)38ca reaction Chek_cuts_40Capt.pngKinematics_40Ca.pngTelescope_Ex_40Capt.pngKinematics_38Capt_withoutCutZero.png
Here are some plot summarizing the analysis status on the [B]40Ca(p,t)38Ca[/B] channel.

Run concerned: 63-89 
Fixed, e755, Fri Jun 29 07:04:35 2018, takeshi, TARGET, Hardware, Cryo-LH2, target temperature temperature2906.png
 
Fixed, e755, Fri Jun 29 08:06:42 2018, e755 Valérie, RUN, General, Cryo-LH2, Summary- Runs 175 to 184 29x
 RUNS during night Friday 29th June From 3am to 8am
RUNS 175 to 184 - cf Scalers, and TcatsHF plots
Run 175 start @ 3h38 stop @3h53
Fixed, e755, Fri Jun 29 08:08:47 2018, e755 Valérie, target :Takeshi, RUN, General, Cryo-LH2, Run 185 13x
 Run 185 Friday 29th June start@ 8h stop@
All triggers Must2+cats1 and Cats 2 div.
Mean intensity of the beam between 1.5 to 1.8 10**5/s during the run, with large fluctuations.
Fixed, e755, Fri Jun 29 09:08:50 2018, e755 Valérie, RUN, General, Cryo-LH2, Plots of Must2 and Cats during run 185 14x
 Run 185 Friday 29th June see entry 742
 
Mean intensity of the beam between 1.5 to 1.8 10**5/s during the run, with large fluctuations.
Fixed, e755, Fri Jun 29 09:53:33 2018, e755 Valérie, target :Takeshi, RUN, General, Cryo-LH2, Run 186 problem Numexo-Narval Run186_TNarvalECCerror.png
 Run 186 Friday 29th June start@ 9h48 stop@9h51
e748 Exxx        551 29 juin  09:50 run_0186.dat.29-06-18_09h48m46s
All triggers Must2+cats1 and Cats 2 div.
Fixed, e755, Fri Jun 29 10:03:06 2018, e755 Valérie, target :Takeshi, RUN, General, Cryo-LH2, Run 187 
 Run 187 Friday 29th June start@ 9h53 stop@10h05
e748 Exxx   95976431 29 juin  10:05 run_0187.dat.29-06-18_09h53m29s
All triggers Must2+cats1 and Cats 2 div.
Fixed, e755, Fri Jun 29 10:41:00 2018, e755 Olivier, Omar, Valérie, target : Nori, Takeshi, RUN, General, Cryo-LH2, Run 188 
 Run 188 Friday 29th June start@10h36 stop@10h40
   
e748 Exxx   18078991 29 juin  10:40 run_0188.dat.29-06-18_10h35m20s
Fixed, e755, Fri Jun 29 12:39:34 2018, Louis, OFFLINE, General, Cryo-LH2, Analysis 38Ar(p,t)36Ar run 128 to 156 Kinematics_36Arpt_FIT1Ex.pngKinematics_36Arpt_FITGS.pngTelescope_Ex_36Arpt.pngTelescope_Ex_36Arpt_fit_exited.png36Ar_level_list.png
Here are some plot summarizing the analysis status on the [B]36Ar(p,t)34Ar[/B] channel.

Run concerned: 128-156 
Fixed, e755, Fri Jun 29 14:00:51 2018, takeshi, RUN, General, Cryo-LH2, summary for 38Ca + liq. H2, updated 
I would summarize the statistics of 38Ca + liq H2 target measurement.
We have obtained the data of 49.5 hours until 28/6, and we added 3.5 hours more data last night.
Fixed, e755, Fri Jun 29 17:43:46 2018, daisuke, TARGET, General, Cryo-LH2, liquid hydrogen target logger 10x
last update at 6 am on June 30
Fixed, e755, Sat Jun 30 01:55:35 2018, Daisuke Louis, RUN, General, Cryo-LH2, RUN 191 FIRST PHYSICS RUN IN 37Ca  21x
[B]RUN 191:[/B]

started at 1:20
Fixed, e755, Sat Jun 30 03:18:14 2018, louis, Daisuke, RUN, Software, Cryo-LH2, Beam image after retracting CHIO visu_2018-06-30_03h12m04s.png
the beam seems more focused after retracting CHIO upstream of M2C. Screenshot taken during RUN 193.
Fixed, e755, Sat Jun 30 04:54:55 2018, louis, daisuke, RUN, General, Cryo-LH2, RUN 194 45x
Continue 37ca data taking.
Fixed, e755, Sat Jun 30 08:24:07 2018, Freddy, Shumpei, Louis, RUN, General, Cryo-LH2, Run 195 r195_scalers.pngr195_CATS.pngr195_TOFin.pngr195_PIDout.pngr195_CATS_cal.png
[U][B]Run 195[/B][/U]

start: 8h08
Fixed, e755, Sat Jun 30 09:17:25 2018, Louis, OFFLINE, General, Cryo-LH2, Offline analysis of 37Ca(p,d)36Ca reaction 7x
Here are some plot summarizing the analysis status on the [B]37Ca(p,d)36Ca[/B] channel. Plots shows performance of the setup in optimal conditions and preli;inary
results.
Fixed, e755, Sat Jun 30 11:25:59 2018, Freddy, Shumpei, BEAM, General, Cryo-LH2, Beam profile on the target target_profile_triggerall.pngtarget_profile_catstrigger.png
The beam profile on the target for each isotope is shown for all trigger and CATS trigger (GATCONF > 500).
X position seems not to depend on the isotope, while Y position depends on the isotope.
Now, 37Ca is a little bit higher form the center of the target, while 36K is almost at the center.
Fixed, e755, Sat Jun 30 13:25:27 2018, Freddy, Shumpei , RUN, General, Cryo-LH2, Run 196 r196_TOF.pngr196_CATS.pngr196_MMImpact.png
[U][B]Run 196[/B][/U]

start: 12h09
Fixed, e755, Sat Jun 30 15:07:43 2018, Shumpei, OFFLINE, General, Cryo-LH2, 37Ca (p,d) 36Ca 37Capd.pdf37Capd_ex.pdf
37Ca (p,d) 36Ca reaction is analyzed (run 191-195).

Gate condition;
Fixed, e755, Sat Jun 30 16:04:11 2018, takeshi, Didier, RUN, General, Cryo-LH2, run 197 scaler_2018-06-30_16h01m46s.pngvisu_2018-06-30_16h03m02s.pngvisu_2018-06-30_16h03m18s.pngvisu_2018-06-30_16h03m32s.png
RUN 197
start: 15h39
stop : 17h38
Fixed, e755, Sat Jun 30 17:45:17 2018, takeshi, Didier, RUN, General, Cryo-LH2, run 198 scaler_2018-06-30_17h46m13s.pngvisu_2018-06-30_17h46m31s.pngvisu_2018-06-30_17h47m00s.pngvisu_2018-06-30_17h47m36s.png
RUN 198

start: 17h40
Fixed, e755, Sat Jun 30 18:09:53 2018, Nori, BEAM, General, N/A, Brho1 and Brho2 optimization for 37Ca ca37brho1.pngca37brho2_yield.pngca37brho2_purity.png
Summary of Brho1 and Brho2 optimizations for the 37Ca beam.

Attachment 1:
Fixed, e755, Sat Jun 30 20:08:27 2018, didier, takeshi, daisuke, RUN, General, Cryo-LH2, RUN 199 37C + liq. H 28x
 
Ongoing, e755, Sat Jun 30 20:12:33 2018, takeshi, TARGET, Hardware, Cryo-LH2, target temperature cell3006.pngheatshield3006.pngscreenshot_2018-07-01_12.17.48.pngscreenshot_2018-07-01_12.22.29.png
Latest update at 12:15 pm on July 1
Here are the temperature logs up to 7:00pm 30/6.
Fixed, e755, Sat Jun 30 23:47:45 2018, takeshi, daisuke, didier, BEAM, General, Cryo-LH2, result of Wien filter tuning wienfiltertuning3006.pngposition37Carun200.pdfposition37Carun201.pdfposition37Carun202.pdf
Here is the summary of the tuning of the Wien filter.
We tried to tune the correction magnet of the wien filter to change the Y position of the beam, especially for 37Ca, which seemed to be at slightly higher
position. 
Fixed, e755, Sun Jul 1 01:48:23 2018, Adrien, RUN, General, Cryo-LH2, Run 205 run205.psr205_HT.pngr205_HT0.pngr205_scaler.png
Starting Run 205 at 1:45.
CATS 1 : 22kps
CATS 2 : 23kps
Fixed, e755, Sun Jul 1 06:42:28 2018, e748, OFFLINE, General, Cryo-LH2, offline of run 192-206 37Capd_192-207.pdf
Here are te plot of analysis of all the available statistic on 37Ca pd.
Fixed, e755, Sun Jul 1 09:43:58 2018, Benoit, Franck, RUN, General, Cryo-LH2, Run 209 9x
Sun 1 July 2018

Start 9:26
Fixed, e755, Sun Jul 1 09:48:44 2018, Benoit, Franck, RUN, General, Cryo-LH2, Run 208 (ENTRY POSTPONED) 7x
Sun 1 July

Start 7:17
Fixed, e755, Sun Jul 1 11:52:27 2018, Benoit, Franck, RUN, General, Cryo-LH2, Run 210 7x
Sun 1 July 2018

Start 11:46
Fixed, e755, Sun Jul 1 17:11:55 2018, freddy, shumpei, daisuke, RUN, General, Cryo-LH2, RUN 214 scaler_2018-07-01_17h10m39s.pngvisu_2018-07-01_17h10m37s.pngvisu_2018-07-01_17h13m30s.png
from 17h01 to 18h39 (anoxia alert. PCP to inspect). 40ca ~3.0 micro A. 
Fixed, e755, Sun Jul 1 18:44:24 2018, freddy, shumpei, daisuke, RUN, General, N/A, RUN 215 scaler_2018-07-01_19h19m32s.pngvisu_2018-07-01_19h19m32s.pngvisu_2018-07-01_19h19m40s.png
Alpha source run. no beam
18h41 started 
19h22 ended
Fixed, e755, Sun Jul 1 19:22:32 2018, freddy, shumpei, daisuke, RUN, General, Cryo-LH2, RUN 216 scaler_2018-07-01_20h05m43s.pngvisu_2018-07-01_20h05m44s.pngvisu_2018-07-01_20h05m52s.pngscaler_2018-07-01_21h18m41s.pngvisu_2018-07-01_21h15m41s.png
37Ca + liquid H 
19h20 started 
21h18 ended.
Fixed, e755, Sun Jul 1 21:21:18 2018, Louis, RUN, General, Cryo-LH2, RUN 217 scaler_2018-07-01_21h22m54s.pngvisu_2018-07-01_21h24m16s.pngvisu_2018-07-01_21h24m33s.pngvisu_2018-07-01_21h24m48s.png
RUN 217

37Ca beam at 2.104pps
Fixed, e755, Sun Jul 1 23:18:21 2018, freddy, louis, shumpei, daisuke, RUN, General, Cryo-LH2, RUN 219 7x
37ca + liq.H
22h50 started
1h00 ended
Fixed, e755, Mon Jul 2 00:53:49 2018, Louis, OFFLINE, General, Cryo-LH2, Update offline analysis on 37Ca(p,d)36Ca 37Capd_All_192_0277.pdf37Capd_Z19_FIT_192_0277.pdf37Capd_Z20_192_0277.pdf
Update of offline Analysis of the [B]37Ca(p,d)36Ca[/B] reaction:

Run 192 to 207
Fixed, e755, Mon Jul 2 01:01:15 2018, daisuke, TARGET, General, Cryo-LH2, cryogenic target logger screenshot_2018-07-02_01.00.23.pngscreenshot_2018-07-02_02.57.45.pngscreenshot_2018-07-02_02.58.23.png
 
Fixed, e755, Mon Jul 2 01:05:12 2018, louis, daisuke, RUN, General, Cryo-LH2, RUN 220 scaler_2018-07-02_01h04m12s.pngvisu_2018-07-02_01h13m50s.pngvisu_2018-07-02_01h14m29s.pngscaler_2018-07-02_01h56m52s.png
37ca + liq.H. 
1h01 started
1h56 ended.Beam stopped due to the trouble with HF C0.
Ongoing, e738, Mon Jul 2 01:29:58 2018, daisuke, OTHER, General, N/A, Q values ensdf_10c_via_pt.pdfPhysRevC.3.543.pdf
 
 Reaction : 9C(1H,3H)7C  Q -29.5098 MeV  Ex 0 MeV
    9C  Z   6 A   9  Mass excess    28911.0 keV 
Fixed, e755, Mon Jul 2 01:58:07 2018, louis daisuke, RUN, General, Cryo-LH2, RUN 221 6x
37ca + liquid H (no beam at times)
1h56 started. no beam
2h03 beam came back with low intensity. Keep running.
Fixed, e755, Mon Jul 2 04:02:15 2018, louis daisuke, RUN, General, Cryo-LH2, RUN 222 8x
37Ca + liq. H
4h00 started
5h57 ended.
Fixed, e755, Mon Jul 2 06:01:35 2018, louis daisuke, RUN, General, Cryo-LH2, RUN 223 7x
37Ca + liquid H. 
5h59 started.40Ca  3.3 micro A.
6h17 beam stop. A few issues including RF. 
Fixed, e755, Mon Jul 2 07:23:34 2018, Louis, OFFLINE, General, Cryo-LH2, 36Ca and 37Ca(p,t)35Ca reaction Ex_all_pd_192to222.pngKinematics_pt_192to222_Z20.pngpt36Ca_Ex_all_192_222.pngKinematics_pt_192to222_Z20_without_line.png
RUN 192 to 222
Beam time: 62h
Fixed, e755, Mon Jul 2 07:37:50 2018, Louis, OFFLINE, General, Cryo-LH2, Background Background.pdf
RUN: 86 to 89
Beam time: 2h30
Beam 40Ca with empty target
Fixed, e755, Mon Jul 2 08:02:52 2018, louis, daisuke, takeshi, didier, RUN, General, Cryo-LH2, RUN 224 scaler_2018-07-02_08h49m14s.pngvisu_2018-07-02_08h49m47s.pngvisu_2018-07-02_08h50m07s.png
37ca + liquid H
8h00 started
10h01 stopped
Fixed, e755, Mon Jul 2 10:12:29 2018, takeshi, didier, RUN, General, Cryo-LH2, RUN225 6x
RUN 225
37Ca beam + liq. H2 target 
10h02 started
Fixed, e755, Mon Jul 2 12:09:56 2018, takeshi, Didier, olivier, RUN, General, Cryo-LH2, RUN 226 6x
RUN 226
37Ca + liq. H2
12h03 started
Fixed, e755, Mon Jul 2 14:37:44 2018, takeshi, didier, olivier, RUN, General, Cryo-LH2, RUN 229 
RUN 229
Ca37 + liq. H2
Beam is back 14h30
Fixed, e755, Mon Jul 2 15:18:21 2018, takeshi, didier, olivier, RUN, General, Cryo-LH2, RUN 230 7x
RUN 230
37Ca + liq. H2
15h11 started
Ongoing, e755, Mon Jul 2 16:16:40 2018, takeshi, TARGET, Hardware, Cryo-LH2, temperature log of the target heatshield0207.pngcell0207.png
 
Fixed, e755, Mon Jul 2 16:50:10 2018, Pierre, Louis, RUN, General, Cryo-LH2, Run 231 scaler_2018-07-02_16h51m31s.pngvisu_2018-07-02_16h52m17s.png
start: 16h47
stop: 18h48
Fixed, e755, Mon Jul 2 18:51:11 2018, Pierre, RUN, General, Cryo-LH2, Run 232 31x
start: 18h49
stop: 20h41
Fixed, e755, Mon Jul 2 20:44:46 2018, pierre, takeshi, louis, nori, daisuke, RUN, General, Cryo-LH2, RUN 233 scaler_2018-07-02_20h45m47s.pngscaler_2018-07-02_21h31m38s.png
37ca + liquid H 
20h43 started.
21h31 stop
Fixed, e755, Mon Jul 2 22:07:27 2018, takeshi, RUN, General, Cryo-LH2, run summary for 37Ca 
Here is the run summary for the 37Ca beam + liq. H2 target setting.
We have obtained totally 65.7 hours data from 0:44 30/6 until 22:00 2/7 for this settings including 1 hour wien filter tuning.
Fixed, e755, Mon Jul 2 23:09:55 2018, Pierre Louis, OFFLINE, General, Cryo-LH2, 37Ca(p,d)36Ca 37Ca_pd_192_231.pdf
 
Fixed, e755, Mon Jul 2 23:29:32 2018, Louis Pierre, OTHER, Hardware, N/A, New division for CATS and plastic 
Division for CATS and Plastic: 3x10^4

Plastic => Chanel 16 of GMT
Fixed, e755, Tue Jul 3 10:47:01 2018, Louis, RUN, General, Cryo-LH2, Run beam tuning 
RUN 236:
started 10h46,  stop at 11h09
Fixed, e755, Tue Jul 3 11:48:30 2018, Louis, RUN, General, Cryo-LH2, Run 238 40Ca 18x
RUN 238:

START 11h23    STOP 12h50
Fixed, e755, Tue Jul 3 13:37:19 2018, Louis, RUN, General, Cryo-LH2, RUN 239 scaler_2018-07-03_13h39m44s.pngvisu_2018-07-03_13h39m45s.pngvisu_2018-07-03_13h41m15s.png
Run 239
 start at  13h30,  stop at 15h18
Fixed, e755, Tue Jul 3 15:22:26 2018, Louis, RUN, General, Cryo-LH2, RUN 240 scaler_2018-07-03_15h23m18s.png
Run 240
start at 15h17, stop at 
Fixed, e755, Tue Jul 3 17:54:44 2018, Louis, RUN, General, Cryo-LH2, Run 241, 242 22x
RUN 241

start at 17h12, stop at 17h35
Fixed, e755, Tue Jul 3 17:55:01 2018, takeshi, RUN, General, Cryo-LH2, run summary for 40Ca + liq. H2 
We have obtained 6 hours data for the 40Ca + liq. hydogen setting today. 
Note that we have already taken 15.6 hours data for this setting at the beginning of the BT.
Fixed, e755, Tue Jul 3 18:19:30 2018, daisuke, OTHER, General, N/A, Data saved after experiment 7x
DAS:    /home/e748/ganacq_manip/e755/das-save/2018-07-03_fin_e755
VIGRU:  /home/e748/analysis/GRU/GRU_18_03_12/vigru_e755_final_2018-07-03_18h15.xml
Online: /home/e748/analysis/nptool/Projects/e755/online/2018-07-03_18h24
Fixed, e755, Tue Jul 3 18:48:52 2018, takeshi, TARGET, Hardware, Cryo-LH2, temperature log of the target cell0307.pngheatshield0307.png
Here is the temperature log of the liquid hydrogen target,
We kept it about 6 days. 
Fixed, e755, Wed Jul 4 15:34:34 2018, Nori, BEAM, General, N/A, 37Ca PID at D6 run332_pid.pdf
A particle identification plot of 37Ca from LISE run 332.
Pinned, e738, Wed Jul 4 17:10:28 2018, daisuke, DAQ, Software, N/A, Second VXI for CATS and syncrhonisation diagnosis 8x
Second VXI crate was addedd for CATS. If the synchronisation is not working, there will be error messages in the display of the chassis in trouble (Desktop
IOLAN).
Fixed, e738, Wed Jul 4 18:11:44 2018, louis, daisuke, RUN, General, 3-alpha, RUN 243  scaler_2018-07-04_18h07m35s.pngvisu_2018-07-04_18h12m36s.pngvisu_2018-07-04_18h12m43s.pngvisu_2018-07-04_18h12m49s.png
MUST2 data taking with the 3 alpha source (positioned downstream of the target to shoot T1 to T8). 
Fixed, e738, Wed Jul 4 18:43:29 2018, daisuke, RUN, General, 3-alpha, RUN 244 scaler_2018-07-04_18h38m39s.pngvisu_2018-07-04_18h39m26s.pngvisu_2018-07-04_18h42m32s.pngvisu_2018-07-04_18h43m12s.png
3 alpha source at 'off-beam-axis' position (right center view from  upstream). FAG ~40 Hz (mostly from T1-4)
Fixed, e738, Thu Jul 5 10:47:42 2018, louis, serge, pierre, daisuke, RUN, General, 3-alpha, RUn 245 scaler_2018-07-05_10h26m15s.pngvisu_2018-07-05_10h26m16s.pngvisu_2018-07-05_10h26m37s.pngvisu_2018-07-05_10h26m46s.pngvisu_2018-07-05_10h27m13s.png
3 alpha source, off beam, low down position . FAG 40 Hz. Likely due to beta rays (see the attachment)
Fixed, e738, Thu Jul 5 10:49:40 2018, louis, serge, pierre, daisuke, RUN, General, 3-alpha, RUn 245 scaler_2018-07-05_10h26m15s.pngvisu_2018-07-05_10h26m16s.pngvisu_2018-07-05_10h26m37s.pngvisu_2018-07-05_10h26m46s.pngvisu_2018-07-05_10h27m13s.png
3 alpha source, off beam, low down position . FAG 40 Hz. Likely due to beta rays (see the attachment)
Fixed, e738, Thu Jul 5 11:08:04 2018, pierre, louis daisuke, RUN, General, N/A, RUN 249 scaler_2018-07-05_11h04m06s.pngvisu_2018-07-05_11h04m05s.png
cats 1 pulser calibration. trigger cats1%1
Fixed, e738, Thu Jul 5 14:12:18 2018, Louis, MUST2, General, 3-alpha, RUN 253 calib alpha scaler_2018-07-05_13h24m41s.pngvisu_2018-07-05_13h24m40s.pngvisu_2018-07-05_13h24m48s.pngvisu_2018-07-05_13h25m03s.pngvisu_2018-07-05_13h26m10s.png
 
Pinned, e738, Thu Jul 5 18:33:54 2018, gilles,fred,J-C,daisuke, DAQ, Hardware, N/A, Caviar DAQ merged. rc_2018-07-05_18h32m56s.pngdas_2018-07-05_18h32m46s.pngdas_2018-07-05_18h32m18s.pngscaler_2018-07-05_18h32m06s.pngdesktop_2018-07-05_18h25m17s.png
The VME crate of CAVIAR was integraded to the DAQ controlled by the GMT master of MUST2. 

One caution. The visual scaler will not refresh if the TGV module of CAVIAR is listed in the configuration files
Fixed, e738, Thu Jul 5 19:22:18 2018, daisuke, RUN, General, 3-alpha, RUN 256 scaler_2018-07-05_19h21m55s.pngvisu_2018-07-05_19h21m38s.pngvisu_2018-07-05_19h21m41s.pngvisu_2018-07-05_19h21m44s.png
3 alpha measurement after merging CAVIAR vme to the DAQ
Pinned, e738, Thu Jul 5 19:26:31 2018, daisuke, MUST2, Hardware, N/A, MUST2 BT/HT screenshot_2018-07-05_19h23m54s.pngscreenshot_2018-07-05_19h24m07s.pngscreenshot_2018-07-05_19h24m17s.pngscreenshot_2018-07-05_19h24m24s.png
 
Pinned, e738, Fri Jul 6 09:40:04 2018, daisuke, OTHER, General, N/A, kinematics plots pt_kinema_30deg_1050um.pdfpt_kinema_30deg_2250um.pdfpt_kinema_30deg_750um_7be.pdf
 
Fixed, e738, Fri Jul 6 17:14:50 2018, daisuke, ONLINE, Software, N/A, Online analysis code: e755.detector screenshot_2018-07-06_17h14m09s.pngscreenshot_2018-07-06_17h14m25s.pngscreenshot_2018-07-06_17h16m43s.png
The file e755.detector was updated to include the following parameters to ModularLeaf. 

    Fixed, e738, Fri Jul 6 18:43:39 2018, Nori, ONLINE, Software, N/A, Online analysis code: e755.detector Capture_du_2018-07-06_18-46-31.png
The modular label file has to be modified.

lpcgrit:/home/e748/analysis/nptool/Projects/e755 $ cat ModularLabel_new.txt 
Fixed, e738, Sat Jul 7 08:16:50 2018, daisuke, MUST2, Hardware, N/A, MUST2 BT/HT screenshot_2018-07-07_08h15m39s.pngscreenshot_2018-07-07_08h15m54s.pngscreenshot_2018-07-07_08h16m04s.pngscreenshot_2018-07-07_08h16m13s.png
 
Pinned, e738, Sat Jul 7 08:26:27 2018, Nori, BEAM, General, N/A, Beam production procedure e738beamproduction.pdf
 
Pinned, e738, Sat Jul 7 08:29:53 2018, daisuke, OTHER, Social, N/A, Shift table 2018-05-08_lise_must2_crypta_schedule_-_Shift_(July_7_to_15).pdf
https://docs.google.com/spreadsheets/d/1jyfw2LT3RGfDY4bcN-9zepZoe2uE89b5CnF4tXzqzj8/edit#gid=716299251
Fixed, e738, Sat Jul 7 14:33:45 2018, shumpei takeshi megumi, TARGET, Hardware, Cryo-LH2, Liquid H2 status liquefying0707.png
We start liquifying H2 at 14:09 and seems to be filled at 14:29.
Fixed, e738, Sat Jul 7 19:47:21 2018, daisuke, MUST2, Hardware, N/A, MUST2 BT/HT screenshot_2018-07-07_19h46m29s.pngscreenshot_2018-07-07_19h46m19s.pngscreenshot_2018-07-07_19h46m00s.pngscreenshot_2018-07-07_19h45m41s.pngscreenshot_2018-07-07_19h45m13s.png
 
Fixed, e738, Sun Jul 8 00:45:44 2018, takeshi, RUN, General, N/A, run summary 
The runsummary for this E738 experiment is available at the same place as previous e755 experiment.

https://docs.google.com/spreadsheets/d/1yErcQcrXPdJjEOfUd9D9KPWWkWQpw5kX4wFze6vwij4/edit#gid=805236919
Fixed, e738, Sun Jul 8 01:24:16 2018, Pierre, RUN, General, Cryo-LH2, Run 284 scaler_2018-07-08_01h25m36s.pngvisu_2018-07-08_01h26m12s.pngscaler_2018-07-08_03h10m42s.png
start: 1h15 
stop: 3h11
Fixed, e738, Sun Jul 8 03:13:35 2018, Pierre, RUN, General, Cryo-LH2, Run 285 scaler_2018-07-08_03h13m06s.pngvisu_2018-07-08_03h19m50s.pngvisu_2018-07-08_03h19m13s.pngvisu_2018-07-08_03h19m27s.pngvisu_2018-07-08_03h20m19s.png
start: 03h12
stop: 05h10
Fixed, e738, Sun Jul 8 05:09:11 2018, Pierre, RUN, General, Cryo-LH2, Run 286 13x
start: 05h11
stop: 07h00
Fixed, e738, Sun Jul 8 07:00:46 2018, Pierre, RUN, General, Cryo-LH2, Run 287 8x
start: 07h01
stop: 08h55
Fixed, e738, Sun Jul 8 07:19:45 2018, Shumpei, OFFLINE, General, Cryo-LH2, Analysis for 10C(p,d)9C and 10C(p,t)8C pd_fig1.pdfpd_fig2.pdfpt_fig1.pdfpt_fig2.pdf
Used data : Run 0284 &  0285 (about 4 hours data)
CsI energy calibration parameters are from previous experiment, optimized for deuteron
Ongoing, e738, Sun Jul 8 08:53:44 2018, takeshi, TARGET, Hardware, Cryo-LH2, temperature log of the target cell0807.pngheatshield0807.pngtempepature0807.png
 
Fixed, e738, Sun Jul 8 09:14:18 2018, takeshi, Didier, Valérie, RUN, General, Cryo-LH2, RUNS 288-290 11x
RUN 288
10C + liq H2
start 08h56 stop 10h56
Fixed, e738, Sun Jul 8 14:23:43 2018, Valérie, RUN, General, Cryo-LH2, RUN Summary and MUST2, DAQ conditions 12x
MUST2 
Physical thresholds ~ 400 keV see DASmust2T4Thres400keV.png 
Pedestals see snapshots DASmust2T1pedestalsThr.png ; 
Fixed, e738, Sun Jul 8 14:57:40 2018, Daisuke, Didier, Valérie, RUN, General, Cryo-LH2, RUN 291 overview 14x
Beam 10C between 9.10**4 and 10**5/s 
dead time between 7 and 12%
 Run 291 start 13h47 stop 15h51
Fixed, e738, Sun Jul 8 16:03:06 2018, Daisuke, Didier, Valérie, RUN, General, Cryo-LH2, RUN 292 -still 10C run292ScalersAt16h02.png
Beam 10C around 1. and 1.1 10**5/s 
dead time between 6 and 12%
 Run 292 start 15h51 stop 16h19 to change CATS HV.
Fixed, e738, Sun Jul 8 16:28:56 2018, Daisuke, Didier, Valérie, RUN, General, Cryo-LH2, RUN 293 run293ScalersAt16h31.png
From Run 293  CATS1 HV = 640V I ~ 0.16 µA ; CATS2 660V I ~ 0.10 µA 
 Run 293 start 16h22; stop at 17h30   
e748 Exxx 1,9G  8 juil. 17:30 run_0293.dat.08-07-18_16h19m54s
Fixed, e738, Sun Jul 8 17:36:47 2018, Daisuke, Didier, Valérie, RUN, General, Cryo-LH2, RUN 294 run294ScalersAt17h35.png
Run 294 start 17h31  stop 17h50 due to the trip of CATS1.
748 Exxx 403M  8 juil. 17:50 run_0294.dat.08-07-18_17h31m47s
Fixed, e738, Sun Jul 8 17:59:12 2018, Daisuke, Takeshi, Valérie, RUN, General, Cryo-LH2, RUN 295 26x
Run 295 start 17h52 stop at 19h52
Beam stop occurred during 19h39 and 19h42 (alarm at the machine)
Fixed, e738, Sun Jul 8 20:00:42 2018, Daisuke, Takeshi, Valérie, RUN, General, Cryo-LH2, RUN 296 +(on-line) eff of CATS 11x
Run 296 start 19h52 stop at 21h51

e748 Exxx 3,1G  8 juil. 21:51 run_0296.dat.08-07-18_19h52m46s
Pinned, e738, Sun Jul 8 21:05:50 2018, daisuke, OTHER, General, N/A, Phase space simulation: 10C(p,t)8C and 9C(p,d)8C pt_sim_phase_plot_8c_t.pdfpt_sim_phase_plot_8c_d.pdf
 
Fixed, e738, Sun Jul 8 21:50:58 2018, Daisuke, Takeshi, Valérie, RUN, General, Cryo-LH2, RUN 297 15x
Run 297 start 21h51 (8th July)  stop at 0h (9th July)
e748 Exxx 3,0G  9 juil. 00:00 run_0297.dat.08-07-18_21h50m55s
MISSING STRIP, Y12 of CATS1 since run 296. see run297_CATSQRaw.png
Fixed, e738, Mon Jul 9 00:03:24 2018, Benoit, Megumi, Takeshi, Valérie, RUN, General, Cryo-LH2, RUN 298 run298_ScalersAt0h10.pngscaler_2018-07-09_02h01m34s.pngvisu_2018-07-09_02h01m41s.pngvisu_2018-07-09_02h01m44s.pngvisu_2018-07-09_02h01m52s.png
Run 298 start 0h (9th July) stop at 02h02
e748 Exxx 2,9G  9 juil. 02:02 run_0298.dat.08-07-18_23h59m40s
Beam stop occurred from 01h06 to 01h09 (rotation speed failing of the LISE target)
Fixed, e738, Mon Jul 9 00:25:30 2018, Nori, CATS, General, N/A, CATS tracking efficiency 8x
We noticed that the tracking efficiency was only 70% while the timing efficiencies were around 95%.
By lowering the thresholds (see Attachment 5-8) 89% tracking efficiency was achieved.
Note: analyzed run 293 (CATS1 640V, CATS2 670V), first 10000 events, only CATS trigger was selected.
Fixed, e738, Mon Jul 9 02:16:19 2018, Benoit, Megumi, RUN, General, Cryo-LH2, RUN 299 scaler_2018-07-09_02h20m00s.pngvisu_2018-07-09_04h04m37s.pngvisu_2018-07-09_04h04m53s.png
Run 299 start 02h01 (9th July) stop at 04h03
e748 Exxx 2,9G  9 juil. 04:03 run_0299.dat.09-07-18_02h01m29s
Fixed, e738, Mon Jul 9 04:22:21 2018, Benoit, Megumi, RUN, General, Cryo-LH2, RUN 300 scaler_2018-07-09_04h17m03s.pngvisu_2018-07-09_05h55m54s.pngvisu_2018-07-09_05h56m57s.pngvisu_2018-07-09_06h00m30s.png
Run 300 start 04h02 (9th July) stop at 06h04
e748 Exxx 2,8G  9 juil. 06:05 run_0300.dat.09-07-18_04h02m08s
Fixed, e738, Mon Jul 9 06:21:54 2018, Benoit, Megumi, RUN, General, Cryo-LH2, RUN 301 scaler_2018-07-09_06h13m13s.pngscaler_2018-07-09_07h51m37s.png
Run 301 start 06h04 (9th July) stop at 7h51

Fixed, e738, Mon Jul 9 07:55:05 2018, Pierre, RUN, General, Cryo-LH2, Run 302 scaler_2018-07-09_07h57m43s.pngvisu_2018-07-09_07h59m57s.pngvisu_2018-07-09_08h00m04s.pngvisu_2018-07-09_08h04m11s.png
start: 07h53
stop: 08h19
Fixed, e738, Mon Jul 9 08:00:11 2018, takeshi, TARGET, Hardware, Cryo-LH2, temperature log of the target heatshield0907.pngcell0907.png
Here are the temperature log of the cyo H2 target during the 10C setting.
Fixed, e738, Mon Jul 9 08:55:13 2018, Pierre Daisuke, RUN, General, Empty, Run 303 
start: 08h27
stop: 08h50
Fixed, e738, Mon Jul 9 08:56:50 2018, Pierre Daisuke, RUN, General, Cryo-empty, Run 304 scaler_2018-07-09_08h57m21s.pngvisu_2018-07-09_09h03m24s.pngvisu_2018-07-09_09h03m30s.pngvisu_2018-07-09_09h04m05s.pngvisu_2018-07-09_09h04m21s.png
start: 08h54
stop: 10h00
Fixed, e738, Mon Jul 9 15:43:50 2018, Pierre Valérie, RUN, General, Cryo-empty, Run 309 scaler_2018-07-09_15h38m55s.pngscaler_2018-07-09_16h10m56s.png
start: 15h36
stop: 16h10
Fixed, e738, Mon Jul 9 17:18:55 2018, e748, RUN, General, Cryo-empty, RUN 311 13x
Run 311
Beam/Detectors Tuning
Fixed, e738, Mon Jul 9 18:03:48 2018, Valérie Louis, RUN, General, Cryo-LH2, RUN 312 25x
Run 312

First RUN of 9C on filled LH2 target
Fixed, e738, Mon Jul 9 19:16:13 2018, Freddy Louis, RUN, General, Cryo-LH2, RUN 313 to 316 Run317_discri_GECO.png
From RUN 313 to RUN 316:

Tuning dor the Drift Chamber:
Fixed, e738, Mon Jul 9 19:24:06 2018, Freddy Valérie Louis, RUN, General, Cryo-LH2, RUN 317 scaler_2018-07-09_19h26m05s.pngvisu_2018-07-09_19h26m13s.pngvisu_2018-07-09_19h28m52s.pngvisu_2018-07-09_19h29m09s.pngscaler_STOP_2018-07-09_19h32m05s.png
Run 317

start: 19h08 stop: 19h30
Fixed, e738, Mon Jul 9 20:28:09 2018, Daisuke, Freddy, Louis, Valérie, RUN, General, Cryo-LH2, RUNS 318 to 320 ProblemDAQcrateCATS1RCAt20h.pngProblemDAQcrateCATS1iolan.pngProblemMergerCATSbranch.png
From RUN 318 to RUN 320:
initial problem was that the stop process was not correctly taken into account on Narval. Geco acor was still running. 
We killed Narval. 
Fixed, e738, Mon Jul 9 20:33:00 2018, Daisuke Louis Valérie , RUN, General, Cryo-LH2, RUN 321- ok again ! 20x
Run 321 start 20:09 
Total beam on CATS ~ 1.7 10**5 /s 
Beam of 9C, 7Be, 8B and 6Li
Fixed, e738, Mon Jul 9 22:15:04 2018, DIdier Daisuke Nori Louis Valérie, RUN, General, Cryo-LH2, RUN 322, strip CATS2 X 19 off 7x
Run 322 start: 22h00 stop: 0h21
e748 Exxx 3,7G 10 juil. 00:21 run_0322.dat.09-07-18_21h58m34s
Beam: 9C
Ongoing, e738, Mon Jul 9 23:21:55 2018, takeshi, TARGET, Hardware, Cryo-LH2, temperature log of the target heatshield0907-2.pngcell0907-2.pngregenerate0907.png
Here are the temperature logs of the liquid H2 target up to now.
I would share the log during the regeneration.
Fixed, e738, Mon Jul 9 23:25:10 2018, takeshi, RUN, General, Cryo-LH2, run summary for 10C beam 
With 10C beam, we have obtained 
31.7 hours of liq. H2 target and
1.2  hours of empty target.
Fixed, e738, Tue Jul 10 00:46:26 2018, Shumpei, Valérie, RUN, General, Cryo-LH2, RUN 323 + Brho line settings Run323_scalersAt0h36.pngRun323_TOFcatsHF.pngRun323_ScalersEndRun.png
Run 323 start: 0h20  stop: 2h45
e748 Exxx 3,5G 10 juil. 02:45 run_0323.dat.10-07-18_00h20m04s 
Beam: 9C
Fixed, e738, Tue Jul 10 01:26:21 2018, Shumpei, OFFLINE, General, Cryo-LH2, Analysis for 10C(p,d)9C and 10C(p,t)8C updated 6x
Used data run run0284-0302 (almost all for 10C beam)
CsI calibration parameters are the same as E755 exp (deuteron optimized),
Fixed, e738, Tue Jul 10 02:47:10 2018, Shumpei, Valérie, RUN, General, Cryo-LH2, RUN 324 24x
Run 324 start: 2h45 stop 5h10
 e748 Exxx 3,8G 10 juil. 05:10 run_0324.dat.10-07-18_02h44m52s
Beam: 9C
Fixed, e738, Tue Jul 10 05:12:31 2018, Shumpei, Valérie, RUN, General, Cryo-LH2, RUN 325 Run325_scalersAt5h12.pngRun325_EDECsIMMpidZoomZ3Z4.pngRun325_scalersEndRunCats1TRIP.png
Run 325 start: 5h10 stop 6h53 due to CATS1 -->tripping
 e748 Exxx 2,5G 10 juil. 06:53 run_0325.dat.10-07-18_05h09m53s
Beam: 9C
Fixed, e738, Tue Jul 10 05:23:19 2018, Shumpei, OFFLINE, General, Cryo-LH2, Analysis for 9C beam setting be7li6pd.pngc9b8pd.pngmissing_invariant_mass.png
Used data: run0312 (about 80 minutes data taking).
Analysis for (p,d) channel and invariant mass
Fixed, e738, Tue Jul 10 05:25:42 2018, Shumpei, BEAM, General, Cryo-LH2, triton contamination in the 9C beam setting triton_contaminant0.pngtriton_contaminant1.pngtriton_contaminant2.png
In MUST2 dE-E plot, strong locus for triton E ~ 40 MeV exists.
Kinematics for triton bellow 45 MeV matches the kinematics of triton 40MeV beam proton elastic scattering.
If coincidence of proton required, still exists for some region (proton forward scattering with enough energy to pass through DSSD).
Fixed, e738, Tue Jul 10 07:16:16 2018, Shumpei, Valérie, RUN, General, Cryo-LH2, RUN 326 9x
Run 326 start: 6h59
  
Beam: 9C
Fixed, e738, Tue Jul 10 12:51:37 2018, marlène, olivier, J-C, daisuke, RUN, General, Cryo-LH2, RUN 330 28x
9C + liquid H. Data taking after replacing CATS1. 
12h03 started
13h54 stop 
Fixed, e738, Tue Jul 10 13:59:09 2018, jacques, daisuke, freddy, RUN, General, Cryo-LH2, RUN 331 6x
9C + liquid H 
13h56 start. 12C 1.7 electric micro A. 
16h51 stop
Fixed, e738, Tue Jul 10 14:22:22 2018, Nori, BEAM, General, Cryo-LH2, Beam image on target run330_imagemust.pngrun330_imagepla.pngrun330_imagecats.png
Reconstructed beam images from run0330.
Fixed, e738, Mon Jul 9 23:29:18 2018, Nori, CATS, General, Cryo-LH2, CATS tracking efficiency run312_plasticq.pngrun312_effexample.png
Analyzed run 312 (9C physics run). CATS calibration files with lowered threshold values
(/home/e748/analysis/nptool/Projects/e755/Calibration/cats/CATS1_X.e738.npt, etc.) were used.
Using the total E information from the plastic, tracking efficiencies for each beam species were estimated.
    Fixed, e738, Tue Jul 10 15:17:21 2018, Nori, CATS, General, Cryo-LH2, CATS tracking efficiency run330_catstracking.png
Tracking efficiencies deduced from run 330 (after replacing CATS1).

9C  89% (see Attachment 1)
Fixed, e738, Tue Jul 10 16:28:53 2018, daisuke, OTHER, Social, N/A, 6Li(p,d)5Li be7li6pd.png2018-07-10_5li_via_pd_spectrum.png2018-07-10_5li_via_pd_level_scheme.png5li_via_pd_msu_kull_pr_163_1066_1967.pdf
The peak near 16 MeV was observed in a measurement in the 1960s. The resonance is close to the 3He-d threshold. The narrow width indicates a binary cluster
of 3He and d formed in 5Li. 
Fixed, e738, Tue Jul 10 17:02:02 2018, jacques, daisuke, freddy, louis, RUN, General, Cryo-LH2, RUN 332 run_332_ScalerStartRun.pngrun_332_ScalerEndRun.pngrun_332_TargetImpact.png
12C primary: 1.7 uA
start: 16h52
stop: 17h52
Fixed, e738, Tue Jul 10 18:23:01 2018, daisuke, OTHER, Social, N/A, mirror reaction of 7Be(p,d)6Be 2018-07-10_6he_via_nd_spectrum.png6he_via_nd_ucdavis_pr_16_31_1977.pdf
 
Fixed, e738, Tue Jul 10 21:26:48 2018, didier, daisuke, RUN, General, Cryo-LH2, RUN 334 17x
9C + liquid H. Probably nobody cares this post right now, but the beam is back. 

21h00 the beam back to LISE. 
Fixed, e738, Tue Jul 10 23:14:31 2018, DD, RUN, General, Cryo-LH2, RUN 335 scaler_2018-07-10_23h16m13s.png
9C + Liquid H run. 
23h11 start. 1.7 electric micro A. Wien filter 1 kV.
01h06 stop.
Fixed, e738, Wed Jul 11 02:52:54 2018, Marlene, RUN, General, Cryo-LH2, RUN336 6x
run336 start 1:07 / stop 2:48
fluctuations of beam intensity
Fixed, e738, Wed Jul 11 02:55:44 2018, e748, RUN, General, Cryo-LH2, RUN 337 run_337_HT_BT_cats.pngrun_337_cats_pos.pngrun_337_scaler.png
RUN 337 start 2:49 /stop 4:09

Beam  intensity CATS 200k pps
Ongoing, e738, Wed Jul 11 03:57:50 2018, e748, OFFLINE, General, Cryo-LH2, Conversion problem conversion_problem.png
Conversion of runs 335 gives the following error (attached)
Size of raw file =3.5 Go 
Size of root file = 1.5Go
Fixed, e738, Wed Jul 11 04:16:04 2018, Nori, BEAM, General, Cryo-LH2, Caviar status run335_cavxcats1hf.pngrun335_cavmult.png
Caviar is now operating at 700 V. TOF-CaviarX position correlations are clearly seen (Attachment 1).
Position efficiencies for each beam species were estimated by applying plastic Q gates on wire multiplicity
distributions (Attachment 2).
Fixed, e738, Wed Jul 11 05:11:19 2018, e748, RUN, General, Cryo-LH2, RUN 338 run_338_scaler.png
RUN 338
9C beam 200 k pps
start 4:09 /stop 5:10
Fixed, e738, Wed Jul 11 06:11:50 2018, e748, RUN, General, Cryo-LH2, RUN 339 9x
RUN 339
9C 210 k pps
start 5:11 / stop 6:08 (beam stopped)
Fixed, e738, Wed Jul 11 06:17:19 2018, e748, RUN, General, Cryo-LH2, RUn 340 
RUn 340
start 6:10 / stop 7:43
Pending, e738, Wed Jul 11 06:29:00 2018, e748, CATS, General, Cryo-LH2, CATS2 status run_340_cats.pngrun_339_cats.png
CATS2 current fluctuates a lot and has increased up to 0.26uA in run 340
In run 340 I observe that a second wire is missing, which is new (see attached file for run 339 and run 440)
Fixed, e738, Wed Jul 11 07:49:12 2018, Marlène, Franck, Jacques, Daisuke, RUN, General, Cryo-LH2, RUN 341 run_341_scaler.pngrun_341_cats.pngrun_341-ht_bt_cats.png
RUn 341
start 7:44 /stop 9h29
Fixed, e738, Wed Jul 11 08:18:00 2018, Nori, CATS, General, Cryo-LH2, CATS efficiency run341_catstracking.png
The tracking efficiency is diminishing probably due to damaged CATS2.
Ongoing, e738, Wed Jul 11 08:32:42 2018, takeshi, TARGET, Hardware, Cryo-LH2, temperature log of the target heatshield1107.pngcell1107.png
 
Fixed, e738, Wed Jul 11 09:32:37 2018, Franck, Jacques, Daisuke, RUN, General, Cryo-LH2, Run 342 10x
Wed 11 July 2018

Start @ 9:19
Fixed, e738, Wed Jul 11 12:02:14 2018, NPTeam, OFFLINE, General, Cryo-LH2, Lauching parrallel analysis of multiple run 
We made  a parralel conversion script in the conversion folder.
You can run up to 5 run in parallel using the command (for run 331-334 in this example):
Fixed, e738, Wed Jul 11 12:04:29 2018, Franck, Jacques + CATS Team, CATS, General, N/A, Run 343 - CATS2 pulser calibration visu_2018-07-11_12h07m59s.png
Start 11:53
Stop 11:59
Fixed, e738, Wed Jul 11 13:24:34 2018, Daisuke,CATS team: Séb, Thom ; Franck, Pierre, Valérie, RUN, General, Cryo-LH2, Runs 344-345 12x
Wed 11 July 2018
run 344 start 12h43 ; stop 13h03
e748 Exxx 900M 11 juil. 13:03 /data/e748X/e755/acquisition/run/run_0344.dat.11-07-18_12h43m33s
Fixed, e738, Wed Jul 11 14:51:13 2018, Daisuke, Franck, Shumpei, Valérie, RUN, General, Cryo-LH2, Run 346 run346_ScalersAt14h57.png
Wed 11 July 2018
run 346 start 14h50; stop 15h14
748 Exxx 777M 11 juil. 15:14 /data/e748X/e755/acquisition/run/run_0346.dat.11-07-18_14h48m47s
Ongoing, e738, Wed Jul 11 15:41:33 2018, Franck, Jacques, Daisuke, RUN, General, Cryo-LH2, Run 347 run347_HT_CATS.pngscaler_2018-07-11_15h36m47s.pngvisu_2018-07-11_15h37m23s.pngvisu_2018-07-11_15h37m37s.png
Run 347 Start 15:28 stop 17h17
e748 Exxx 3,6G 11 juil. 17:17 /data/e748X/e755/acquisition/run/run_0347.dat.11-07-18_15h28m32s
CATS thresholds lowered from 40 to 24 mV
Fixed, e738, Wed Jul 11 16:51:50 2018, Nori, CATS, General, Cryo-LH2, CATS efficiency run347_catseff.png
The tracking efficiency recovered after replacing CATS2.

9C  91%
Ongoing, e738, Wed Jul 11 17:25:11 2018, Louis, Daisuke, Nori, Valérie, RUN, General, Cryo-LH2, Run 348 run348_scalersAt17h26.pngvisu_2018-07-11_17h39m20s.pngvisu_2018-07-11_17h39m25s.pngscaler_STOP_2018-07-11_18h09m53s.png
Run 348 Start 17h17

Beam: 9C at 2.3*10⁵pps in CATS1, 2uA of intensity of the primary beam
Fixed, e738, Wed Jul 11 18:31:23 2018, Jacques, Didier, Louis, RUN, General, Cryo-LH2, Run 349 6x
Run 349 

Start 18h22  Stop 18h47
Fixed, e738, Wed Jul 11 19:08:40 2018, Didier, Louis, RUN, General, Cryo-LH2, RUN 350 10x
Run 350

Start 19h00 Stop 19h11
Fixed, e738, Wed Jul 11 19:17:20 2018, Didier, Louis, RUN, General, Cryo-LH2, RUN 351 scaler_2018-07-11_19h20m33s.pngvisu_2018-07-11_19h21m57s.pngvisu_2018-07-11_19h22m00s.pngvisu_2018-07-11_19h22m58s.pngscaler_STOP_2018-07-11_19h57m00s.png
Run 351

Start 19h14 Stop 19h53
Fixed, e738, Wed Jul 11 20:00:01 2018, Didier, Valérie, Louis, RUN, General, Cryo-LH2, RUN 352 7x
Run 352

Start 19h57 Stop 21h51
Fixed, e738, Wed Jul 11 21:55:23 2018, Daisuke, Didier, Valérie, Louis, RUN, General, Cryo-LH2, RUN 353 6x
Run 353

Start 21h50 Stop 
Fixed, e738, Wed Jul 11 23:36:27 2018, Didier, Louis, Freddy, Shumpei, RUN, General, Cryo-LH2, RUN 354 scaler_2018-07-11_23h42m26s.pngvisu_2018-07-11_23h40m27s.pngvisu_2018-07-11_23h42m12s.pngvisu_2018-07-11_23h42m15s.pngvisu_2018-07-11_23h43m02s.png
Run 354

Start 23h33 Stop 1h37
Fixed, e738, Thu Jul 12 02:12:20 2018, Shumpei, Freddy, RUN, General, Cryo-LH2, RUN 355 7x
[U][B]RUN 355[/B][/U]

start: 2h04
Fixed, e738, Thu Jul 12 04:40:32 2018, Shumpei, CATS, General, Cryo-LH2, Analysis with only one of the CATSs cats1.pngcats2.pngcats3.pngcats4.png
Analyzed data : run 0331
Used reaction : 7Be(p,d)6Be (ground state and 2+ state 1.6 MeV are mainly populated).
Fixed, e738, Thu Jul 12 05:03:49 2018, Shumpei, Freddy, RUN, General, Cryo-LH2, RUN 356 7x
[U][B]RUN 356[/B][/U]

start: 4h24
Fixed, e738, Thu Jul 12 07:05:53 2018, Shumpei, Freddy, Megumi, Valérie, RUN, General, Cryo-LH2, RUN 357 7x
[U][B]RUN 357[/B][/U]

start: 6h39
Fixed, e738, Thu Jul 12 07:43:25 2018, Shumpei, OFFLINE, General, Cryo-LH2, Analysis of 9C beam setting c9b8pd2.pngbe7li6pt.pngc9b8pt.png
Used data : run0312-0355

For (p,t) reaction, the value of the mass for N=1 isotone is taken from proposal, so it can be shifted.
Fixed, e738, Thu Jul 12 08:16:21 2018, Daisuke, Megumi, Valérie, RUN, General, Cryo-LH2, RUN 358 20x
[U][B]RUN 358[/B][/U]
start: 8h14 stop: 9h48
Fixed, e738, Thu Jul 12 09:52:07 2018, Daisuke, Megumi, Valérie, RUN, General, Cryo-LH2, RUN 359 6x
RUN 359

start: 9h48 stop: 11h25
Fixed, e738, Thu Jul 12 11:28:46 2018, Daisuke, Megumi, Valérie, RUN, General, Cryo-LH2, RUN 360 10x
RUN 360
e748 Exxx 3,4G 12 juil. 13:08 /data/e748X/e755/acquisition/run/run_0360.dat.12-07-18_11h24m44s
start: 11h25 stop: 13h08
Fixed, e738, Thu Jul 12 13:09:14 2018, Daisuke, Megumi, Valérie, RUN, General, Cryo-LH2, RUN 361 6x
RUN 361
e748 Exxx 3,5G 12 juil. 15:01 /data/e748X/e755/acquisition/run/run_0361.dat.12-07-18_13h07m40s
start: 13h08 stop: 14h59
Ongoing, e738, Thu Jul 12 13:49:38 2018, takeshi, TARGET, Hardware, Cryo-LH2, temperature log of the target heatshield1207.pngcell1207.png
 
Fixed, e738, Thu Jul 12 15:07:43 2018, Daisuke, Louis, Marlène, Megumi, Valérie, RUN, General, Cryo-LH2, RUN 362-TRIGGER TESTS 11x
RUN 362 WITH CHANGE OF TRIGGERS FOR TESTS see below
e748 Exxx 1,7G 12 juil. 16:09 /data/e748X/e755/acquisition/run/run_0362.dat.12-07-18_15h08m50s
start: 15h08  stop: 16h08
Fixed, e738, Thu Jul 12 15:27:56 2018, daiuske, MUST2, General, N/A, MUST2*CATS coincidence trigger 2018-07-09_message_adrien.pdfScreenshot_2018-07-09_()_-_document.png
Message from Adrien.
Fixed, e738, Thu Jul 12 16:22:43 2018, Frank, Louis, RUN, General, Cryo-LH2, RUN 363 10x
RUN 363
 
start: 16h09  stop: 18h10
Fixed, e738, Thu Jul 12 18:12:33 2018, Frank, Louis, RUN, General, Cryo-LH2, RUN 364 12x
RUN 364
 
start: 18h11  stop: 20h45
Pinned, e738, Thu Jul 12 18:47:32 2018, Nori, BEAM, General, N/A, Summary of Brho2 values 



Beam
Brho2 RMN (Tm)
Brho2 L++ (Tm)




9C
1.6352
1.6343


10C
1.8345
1.8335


40Ca
(high)
2.2448
2.2432


37Ca
1.9242
1.9228


38Ca
1.9860
1.9846


40Ca
Fixed, e738, Thu Jul 12 20:47:32 2018, Frank, Louis, RUN, General, Cryo-LH2, RUN 365 10x
RUN 365
 
start: 20h46  stop: 22h43
Fixed, e738, Thu Jul 12 22:45:50 2018, Frank, Louis, RUN, General, Cryo-LH2, RUN 366 15x
RUN 366
 
start: 22h44  stop: 00h42
Fixed, e738, Fri Jul 13 00:45:45 2018, Pierre, RUN, General, Cryo-LH2, Run 367 
start: 00h44
Fixed, e738, Fri Jul 13 00:47:23 2018, Pierre, RUN, General, Cryo-LH2, Run 367 scaler_2018-07-13_00h46m09s.pngvisu_2018-07-13_00h51m01s.pngvisu_2018-07-13_00h50m40s.png
RUN 367

start: 00h44
Fixed, e738, Fri Jul 13 02:45:44 2018, Pierre, RUN, General, Cryo-LH2, Run 368 7x
RUN 368

start: 02h44
Fixed, e738, Fri Jul 13 04:09:10 2018, takeshi, TARGET, Hardware, Cryo-LH2, temperature of the target cell1307.png
We found the target temperature suddenly increased at around 3:40 13th.
The online beam image is still indicating the target is filled up to now.
Fixed, e738, Fri Jul 13 04:48:19 2018, Pierre, RUN, General, Cryo-LH2, Run 369 7x
RUN 369

start: 04h47
Fixed, e738, Fri Jul 13 06:02:31 2018, takeshi, pierre, TARGET, General, Cryo-LH2, target is half filled target1307.pdfcell1307_2.png
We found the liquid hydrogen target is filled only half during the run 368, around 4:10.
We will continue the measurement for now.
Fixed, e738, Fri Jul 13 09:03:11 2018, takeshi, RUN, General, Cryo-LH2, run summary 9C + H2 
Here is the run summary of the setting 9C beam + liquid H2 target.
Up to now, we have obtained 78 hours data, including missing strips in CATS , MUST2*BEAM trigger test, and half-filled target.
We will go to 9C + empty setting from 9:10.
Fixed, e738, Fri Jul 13 09:35:26 2018, Olivier, Serge, Jacques, J-C, thomas, shumpei, daisuke, RUN, General, Cryo-empty, RUN 370 visu_2018-07-13_09h36m18s.pngscaler_2018-07-13_09h36m16s.png
Empty target + 9C. 
9h29 The beam is back. start 9h28 stop 11h21
e748 Exxx 2,1G 13 juil. 11:21 /data/e748X/e755/acquisition/run/run_0370.dat.13-07-18_09h28m21s
Fixed, e738, Fri Jul 13 13:41:48 2018, Daisuke, Jacques, Megumi, Olivier, Otsu, Takeshi, Valérie, RUN, General, Cryo-empty, RUNS 371-372 32x
Empty target + 9C. 
Run 371 start 11h20 stop 13h20
 e748 Exxx 2,1G 13 juil. 13:20 /data/e748X/e755/acquisition/run/run_0371.dat.13-07-18_11h20m03s
Fixed, e738, Fri Jul 13 16:41:49 2018, Antoine, Maurycy, OFFLINE, Social, Cryo-LH2, Multiparticles from (p,t) up to 5 Light Charged Particles in Must ! 15x
 
Fixed, e738, Fri Jul 13 18:07:04 2018, J-C, cristelle, nori, olivier, daisuke, RUN, General, Cryo-empty, RUN 373 scaler_2018-07-13_17h43m06s.pngvisu_2018-07-13_17h43m05s.png
12C 5+ beam. CATS2 trigger. 
17h29 start 
17h41 stop
Fixed, e738, Fri Jul 13 18:08:31 2018, J-C, cristelle, nori, olivier, daisuke, RUN, General, Cryo-empty, RUN 374 6x
12C5+ beam. Trigger T1-8 + CATS1%30000 + CATS2%30000 + Plastic%10000. 
Target empty (under cooling). 
beam intensity 350 enA
Fixed, e738, Fri Jul 13 21:15:53 2018, J-C, nori, shumpei, takeshi, hide, didier, serge, daisuke, RUN, General, Cryo-empty, RUN 375: 12C pilot run 8x
12C beam + empty target after measurement of 9C momentum distribution. 
trigger t1-8 + cats 1 2 %30000 + plastic %10000
start 20h47 / stop 21h08 
Fixed, e738, Fri Jul 13 22:00:59 2018, didier, nori, takeshi, shumpei, hide, daisuke, RUN, General, Cryo-LH2, RUN 376: 12C first run 22x
12C + liquid H. 
start 21h44
stop 22h43
Fixed, e738, Fri Jul 13 23:10:55 2018, e748, RUN, General, Cryo-LH2, run 377 13x
count rate in Cats : 100 kHz
Start time: 22:44
Stop: 00:42
Fixed, e738, Fri Jul 13 23:22:26 2018, Shumpei, OFFLINE, General, Cryo-LH2, 12C beam analysis 12c.pdf
Used data run0376 (about 1 hour)

Only target position and recoil pid (deuteron or triton) is gated.
Fixed, e738, Sat Jul 14 00:32:55 2018, Shumpei, OFFLINE, General, Cryo-empty, empty target analysis for 9C beam setting pd.pdfpd_60deg.pdfpt.pdfpt_60deg.pdf
H2 filled: run0312-0355
empty: run0370-0372
Fixed, e738, Sat Jul 14 01:24:51 2018, e748, RUN, General, Cryo-LH2, run 378 scaler_2018-07-14_00h46m48s.pngvisu_2018-07-14_00h48m31s.pngvisu_2018-07-14_00h52m28s.png
count rate in Cats : 100 kHz
Start time: 00:42
Fixed, e738, Sat Jul 14 02:46:34 2018, e748, RUN, General, Cryo-LH2, run 379 scaler_2018-07-14_02h44m19s.pngvisu_2018-07-14_02h45m36s.png
count rate in Cats : 100 kHz
Start time: 02:41
Fixed, e738, Sat Jul 14 05:00:37 2018, e748, RUN, General, Cryo-LH2, run 380 scaler_2018-07-14_04h41m20s.pngvisu_2018-07-14_04h49m58s.png
count rate in Cats : 100 kHz
Start time: 04:38
Fixed, e738, Sat Jul 14 06:49:03 2018, e748, RUN, General, Cryo-LH2, run 380 scaler_2018-07-14_06h43m26s.pngscreenshot_2018-07-14_06h42m28s.pngvisu_2018-07-14_06h44m35s.pngvisu_2018-07-14_06h48m04s.pngvisu_2018-07-14_06h50m58s.png
count rate in Cats : 100 kHz
Start time: 06:39
Fixed, e738, Sat Jul 14 09:57:36 2018, takeshi, TARGET, Hardware, Cryo-LH2, target temperature during night liquiefy1307.png
I would share the temperature log of the target as  it was liquefied 21:00 13th.
Fixed, e738, Sat Jul 14 10:14:00 2018, marlène, jacques, daisuke, RUN, General, Cryo-LH2, RUN 382 9x
12C + liquid H. Before the run, the beam stopped for 2 hours due to the gate valve of E9 shut out the beam. This is because the manually operate turbo pump
was turned off by itself due to unknown reason. Sébastien came to close the valve of this turbo pump and evacuate E9 using another turbo pump only. The
vacuum of E9 is about 4e-5 mbar as of 9 am.The interlock is set at 9e-5 mbar. 
Fixed, e738, Sat Jul 14 11:37:58 2018, marlène, daisuke, RUN, General, Cryo-LH2, RUN 383 25x
12C + liquid H. 
11h33 start. 
12h00 Asked PCP to increase the intensity. CATS1,2 120 kpps. Plastic 100 kpps. CATS1/2 0.14/0.10 micro A. CATS2 current bursts to ~0.5 micro A once every
Fixed, e738, Sat Jul 14 14:01:55 2018, Daisuke, Jacques, Shumpei, Valérie, RUN, General, Cryo-LH2, RUNS 384-385 16x
12C + liquid H. 

RUN 384 start 13h58 stop 15h54
Fixed, e738, Sat Jul 14 18:18:33 2018, Daisuke, Jean-Charles, Megumi, Nori, Shumpei, Valérie, RUN, General, Cryo-LH2, RUN 386 TUNING 9C 8x
9C + liquid H. 
SLITS FH31 +/- 2mm then +/-5 mm at the beginning of the run 
RUN 386 start 18h16 stop 18h28
Fixed, e738, Sat Jul 14 18:36:38 2018, Daisuke, Jean-Charles, Megumi, Nori, Shumpei, Valérie, RUN, General, Cryo-LH2, RUN 387 TUNING 9C 
9C + liquid H. 
SLITS FH31 +/- 5 mm F43 opened
I ~ 1.6µA  TRIGGERS CATS2, PLASTIC div
Fixed, e738, Sat Jul 14 18:37:29 2018, Daisuke, Jean-Charles, Megumi, Nori, Shumpei, Valérie, RUN, General, Cryo-LH2, RUN 388 TUNING 9C Run388_ScalersCaviarFH31_5mm_I1.6µA.pngRun388_Scalers.pngRun388_TOF.png
9C + liquid H. 
SLITS FH31 +/- 5 mm F43 opened
I ~ 1.6µA  normal TRIGGERS  MUST2 CATS div Plastic div 
Fixed, e738, Sat Jul 14 18:54:01 2018, Daisuke, Jean-Charles, Megumi, Nori, Shumpei, Valérie, RUN, General, Cryo-LH2, RUN 389 TUNING 9C 7x
9C + liquid H. 
SLITS FH31 +/- 30 mm F43 opened
I ~ 1.6µA  normal TRIGGERS  MUST2 CATS div Plastic div 
Fixed, e738, Sat Jul 14 19:01:22 2018, Daisuke, Jean-Charles, Megumi, Nori, Shumpei, Valérie, RUN, General, Cryo-LH2, RUN 390 TUNING 9C 7x
9C + liquid H. 
SLITS FH31 +/- 20 mm F43 V 10 mm; FH43 10 mm  I~1.9 µA
Fixed, e738, Sat Jul 14 19:38:25 2018, Daisuke, Jean-Charles, Shumpei, Valérie, RUN, General, Cryo-LH2, RUN 391 TUNING 9C Run391_TOF.pngRun391_scalers.png
9C + liquid H. 
SLITS FH31 +/- 20 mm F43 V 10 mm; FH43 10 mm  I~1.9 µA
Fixed, e738, Sat Jul 14 20:16:50 2018, Daisuke, Shumpei, Valérie, RUN, General, Cryo-LH2, RUN 392 9C 21x
9C + liquid H. 
RUN 392 start 19h46 stop 21h47
e748 Exxx 3,5G 14 juil. 21:49 /data/e748X/e755/acquisition/run/run_0392.dat.14-07-18_19h45m58s
Fixed, e738, Sat Jul 14 21:53:48 2018, Daisuke, Shumpei, Valérie, RUN, General, Cryo-LH2, RUN 393 9C 9x
9C + liquid H. 
RUN 393 start 21h48  stop  23h49
e748 Exxx 4,0G 14 juil. 23:49 /data/e748X/e755/acquisition/run/run_0393.dat.14-07-18_21h48m17s
Fixed, e738, Sun Jul 15 00:48:03 2018, takeshi, RUN, General, N/A, run summary 
Here are the run summary of E738 experiment up to 1:00 am 15th.
31.7 hours for 10C + H2
1.2  hours for 10C + empty
Fixed, e738, Sun Jul 15 00:49:52 2018, Megumi, Shumpei, Takeshi, Benoît, Valérie, RUN, General, Cryo-empty, RUN 394 9C Run394_scalersAt0h45.pngRun394_CatsStrRaw.pngRun394_BeamTracks.pngRun394_TOF.pngvisu_2018-07-15_03h20m53s.png
9C + Empty target  15th JULY
RUN 394 start 0h43  stop   03h20
e748 Exxx 2,9G 15 juil.  2018 /data/e748X/e755/acquisition/run/run_0394.dat.15-07-18_00h43m25s
Fixed, e738, Sun Jul 15 01:26:49 2018, takeshi, TARGET, Hardware, Cryo-LH2, temperature log of the target heatshiled1507.pngcell1507.png
Here are the temperature log of the target before it was evaporated.
Fixed, e738, Sun Jul 15 01:35:09 2018, takeshi, Valérie, ONLINE, General, N/A, problem of the beam image on vigru run394.pngtarget_run393.pdftarget_run394.pdftargetY_run393.pdftargetY_run394.pdf
The beam image at the target is not clear on online monitor.
We have confirmed that the target is correctly evacuated to empty now (and fully filled before that) by offline.
Fixed, e738, Sun Jul 15 03:27:25 2018, Megumi, Benoît, RUN, General, Cryo-empty, RUN 395 9C scaler_2018-07-15_03h30m58s.pngvisu_2018-07-15_06h00m44s.pngvisu_2018-07-15_06h00m56s.pngvisu_2018-07-15_06h01m02s.pngvisu_2018-07-15_06h01m11s.png
9C + Empty target  15th JULY
RUN 395 start 03h20  stop  05h59
e748 Exxx 2,8G 15 juil. 06:01 /data/e748X/e755/acquisition/run/run_0395.dat.15-07-18_03h20m21s
Fixed, e738, Sun Jul 15 06:17:04 2018, Megumi, Benoît, RUN, General, Cryo-empty, RUN 396 9C 8x
9C + Empty target  15th JULY
RUN 396 start 06h00  stop  7h59
Fixed, e738, Sun Jul 15 08:04:12 2018, daisuke, RUN, General, Cryo-empty, RUN 397 32x
9C + empty. 

08h00 start. 12C 1.8 micro A. 
Fixed, e738, Sun Jul 15 10:04:13 2018, daisuke, RUN, General, Cryo-empty, RUN 398 scaler_2018-07-15_10h05m09s.png
9Cc + empty 

10h01 start 
Fixed, e738, Sun Jul 15 13:57:59 2018, daisuke, RUN, General, Cryo-empty, RUN 415 34x
9C + empty run. 

From 10 to 13h45, we had several issues with DAQ. All data from RUN 398 to 414 are JUNK. 
Fixed, e738, Sun Jul 15 19:05:20 2018, takeshi, RUN, General, N/A, run summary of E738 
Runsmmary of the E738 experiment.
31.7 hours for 10C + H2
1.2 hours for 10C + empty
Fixed, e738, Mon Jul 16 11:22:26 2018, thomas, daisuke, RUN, General, N/A, RUN 416 visu_2018-07-16_11h14m17s.png
CATS1 pulser calibration. trigger CATS1.
Attenuation 1/1, 1/2, 1/4, 1/5, 1/10 and pedestal.v
Fixed, e738, Mon Jul 16 11:23:55 2018, thomas, daisuke, RUN, General, N/A, RUN 417 visu_2018-07-16_11h25m58s.pngscaler_2018-07-16_11h25m58s.png
CATS2 pulser calibration. trigger CATS2. 
Attenuation 1/1, 1/2, 1/4, 1/5, 1/10 and pedestal.
Fixed, e738, Mon Jul 16 15:13:21 2018, daisuke, RUN, General, 3-alpha, RUN 419 visu_2018-07-16_14h58m37s.pngvisu_2018-07-16_14h58m45s.pngvisu_2018-07-16_14h58m55s.png
MUST2 3 alpha source at center 
13h22 start 
15h05 stop. 
Fixed, e738, Mon Jul 16 16:13:00 2018, daisuke, RUN, General, 3-alpha, RUN 420 scaler_2018-07-16_16h10m10s.pngvisu_2018-07-16_16h09m59s.pngvisu_2018-07-16_16h10m02s.pngvisu_2018-07-16_16h10m05s.png
MUST2 3 alpha shooting a bit left

15h10-16h08 
Fixed, e738, Mon Jul 16 16:44:43 2018, daisuke, RUN, General, 3-alpha, RUN 422 visu_2018-07-16_16h32m59s.png
MUST2 + 3 alpha shooting left 
Fixed, e738, Mon Jul 16 17:25:22 2018, daisuke, RUN, General, 3-alpha, RUN 422 visu_2018-07-16_17h22m02s.pngvisu_2018-07-16_17h05m26s.pngscaler_2018-07-16_17h22m04s.png
MUST2 + 3 alpha shooting right. 
Fixed, e738, Mon Jul 16 18:46:34 2018, daisuke, RUN, General, 3-alpha, RUN 423 scaler_2018-07-16_18h40m56s.pngvisu_2018-07-16_18h03m27s.pngvisu_2018-07-16_18h39m46s.pngvisu_2018-07-16_18h39m49s.png
MUST2 + 3 alpha shooting center.
Fixed, , Tue Feb 26 12:16:10 2019, iulian freddy francois, MUST2, Software, N/A, run 41 Calimero run MUVI 1 sector1X 
[U][B]Run 41[/B][/U]

Calimero WORKS!!