MUST2 SAMURAI_2018 S3-LEB-LPC SUPERNEMO MUGAST EXPAND SCALP GALATRON HiCARI VELO
  MUST2  Not logged in MUST2
Entry  Tue Mar 27 17:22:24 2018, e744 : Valerian, e744, MUST2, Hardware, Ongoing, 3-alpha, Choosing the DSSSDs 
    Reply  Wed Mar 28 13:21:32 2018, e744 : Valerian, e744, MUST2, Hardware, Ongoing, 3-alpha, Choosing the DSSSDs 
       Reply  Wed Mar 28 16:35:01 2018, e744 : Valerian, e744, MUST2, Hardware, Ongoing, 3-alpha, Choosing the DSSSDs TimeMust2X_MUVI2_uncalib.pngTimeMust2Y_MUVI2_uncalib.pngSpectresMUVI2stripXT300ns.png
Message ID: 336     Entry time: Wed Mar 28 16:35:01 2018     In reply to: 335
Author: e744 : Valerian 
ExpNbr: e744 
Type: MUST2 
Category: Hardware 
Status: Ongoing 
Target-Source: 3-alpha 
Subject: Choosing the DSSSDs 

e744 : Valerian wrote:

e744 : Valerian wrote:
We can see that the DSSSDs on T1(CsI) T3(CsI) T4(CsI) and T5(SiLi) are in good shape (cf :Bidim for T1 T3 T4 T5 T6 T7 T8 ).

As for now, we would like to keep the telescope as is. M2C should be moved tomorrow (28/03/18).

After that we would like to use the two spare DSSSDs available on both T2 and on the O degree telescope (now called T5(CsI)).

If the spare DSSSDs are judged not be good enough for the experiment, we will swap current T5(SiLi) DSSDs on the 0 degree Telescope T5(CsI).


Which telescope should we take for T5? T7 or T6?


Looking at the previous Calimero tests Adrien did during his experiment, neither telescope are good as is... the T7 has no time calibration and T6 might have some Asics problem...

We can either use T6 and check if the problem we saw on it's DSSDs are due to some electronics problem or use a completly different telescope from the spare we have...

EDIT 29/03/18 : After discussion with Laurent the option to use a new DSSD on T6 seems more appropriate, still ongoing.
Attachment 1: TimeMust2X_MUVI2_uncalib.png  83 kB  Uploaded Wed Mar 28 17:50:06 2018  | Hide | Hide all
TimeMust2X_MUVI2_uncalib.png
Attachment 2: TimeMust2Y_MUVI2_uncalib.png  68 kB  Uploaded Wed Mar 28 17:50:08 2018  | Hide | Hide all
TimeMust2Y_MUVI2_uncalib.png
Attachment 3: SpectresMUVI2stripXT300ns.png  46 kB  Uploaded Wed Mar 28 17:50:10 2018  | Hide | Hide all
SpectresMUVI2stripXT300ns.png

ELOG Home Page