Message ID: 110     Entry time: Sun Jul 2 10:31:48 2017
Author: Valérie Lapoux 
ExpNbr: e748 
Type: ONLINE 
Category: Hardware 
Status: Fixed 
Target-Source: CD2 
Subject: Change of the electronics for TAC Plast CATS1 
Shift U (Béa +Vlx) entered in the room to check the electronics of Cats1 and of the TAC plast-Cats1
Now we have taken the output of one of the TAC : START=CATS1_FAG - STOP plast (no val)
We send it to a Linear Fifo from which it is duplicated for the ADC channels:
-ADC of VXI MUST2 parameter T_PL_CATS1 ; add 23
-ADC of VXI CHIO parameter T_PLch_CATS1; add 19
NB:
Now we put 50 Ohms everywhere in the logic Fifo for Cats1 Validated in the CATS electronics.