MUST2 SAMURAI_2018 S3-LEB-LPC SUPERNEMO MUGAST EXPAND SCALP GALATRON HiCARI VELO
  MUST2  Not logged in MUST2
Message ID: 97     Entry time: Sat Jul 1 14:32:02 2017
Author: Valérie Lapoux 
ExpNbr: e748 
Type: DAQ 
Category: General 
Status: Fixed 
Target-Source:  
Subject: Scalers U2M, parameters 
U2M configuration +Actions ganlx11

The signals for the scalers are converted from NIM to ECL in a 16 channel module NIM-ECL.
The cable is PHYSICALLY connected from the NIM-ECL module to the U2M on Groups 1 & 2.
Normally we should read these scalers on the U2M from channel 1 to 16 BUT
we found that the good channels are running on channels 17 to 32. See below.
We have defined the actions for all possible channels of the U2M registers 1 to 16 (Groups 1 and 2), and 17 to 32
(Groups 3 and 4)
Attachment 1: ScalersU2Mok.png  71 kB  Uploaded Sat Jul 1 15:44:25 2017  | Hide | Hide all
ScalersU2Mok.png
Attachment 2: CompilActionsganlx11ScalerGr1to4..png  185 kB  Uploaded Sat Jul 1 15:44:44 2017  | Hide | Hide all
CompilActionsganlx11ScalerGr1to4..png

ELOG Home Page