For runs 80- 81:
for test purposes, we changed the coincidence mode for CATS: we put FAG instead of the Seq1 coming from the gamer.
Run 80 start 11h33; stop 11h40
e748 Exxx 15794176 2 juil. 11:40 run_0080.dat.02-07-17_11h33m07s
CD2 2.5 mg/cm2
change of the trigger conditions only CATS1 div =100
(all bidiv at 100)
-------------------------------------------------------------------------------------------
Run 81 start 11h42; stop 11h48 triggers IN1 to IN8, all Must2
e748 Exxx 4128768 2 juil. 11:48 run_0081.dat.02-07-17_11h42m27s
-------------------------------------------------------------------------------------------
CONDITIONS FOR TAC:
START STOP RANGE PARAMETER ADDRESS VXI MODULE
-------------------------------------------------------------------------------------------
CATS1_FAG CAVIAR (del 550ns) 1µs T_CATS1_CAV ADC VXI MUST2 add=19
CATS1_FAG CATS2_FAG (del 33ns) 200ns T_CATS1_2 ADC VXI MUST2 add=28
OU_MUVI CATS1_FAG 500ns T_MUVI_CATS1 ADC VXI MUST2 add=21
CATS2_FAG PLAST (val) 200ns T_PL_CATS2 ADC VXI MUST2 add=22
CATS1_FAG PLAST (no val) 200 ns T_PL_CATS1 ADC VXI MUST2 add=23
-------------------------------------------------------------------------------------------
CATS1_FAG PLAST (no val) 200ns T_PLch_CATS1 ADC VXI CHIO add=19
PLAST val Gamer ChIo CHIO (no val) 2µs T_PL_CHIO ADC VXI CHIO add=3
-------------------------------------------------------------------------------------------
TAC EXL HF 200 ns EXL_HF ADC VXI MUST2 add=18 |