MUST2 SAMURAI_2018 S3-LEB-LPC SUPERNEMO MUGAST EXPAND SCALP GALATRON HiCARI VELO
  MUST2  Not logged in MUST2
Message ID: 735     Entry time: Thu Jun 28 10:38:58 2018
Author: Freddy 
ExpNbr: e755 
Type: MUST2 
Category: General 
Status: Fixed 
Target-Source: N/A 
Subject: T4 Comparison of calibration runs 
Attached is a comparison of two calibrations performed before the experiment (2 weeks and one day before) for Telescope 4 (the one having a degraded resolution in Ex on the offline).
One can see that:
  • The T4 resolution for strips X has been degraded between the two source runs.
  • The T4 resolution for strips Y remains ok and should be used for the analysis (slightly degraded only)
  • From the pedestal extrapolation, it also seems that there was a global drift for some channels.
Attachment 1: Comparison_T4X_calibbeforeexp.png  173 kB  Uploaded Thu Jun 28 12:17:51 2018  | Hide | Hide all
Comparison_T4X_calibbeforeexp.png
Attachment 2: Comparison_T4Y_calibbeforeexp.png  145 kB  Uploaded Thu Jun 28 12:18:09 2018  | Hide | Hide all
Comparison_T4Y_calibbeforeexp.png