MUST2 SAMURAI_2018 S3-LEB-LPC SUPERNEMO MUGAST EXPAND SCALP GALATRON HiCARI VELO
  MUST2  Not logged in MUST2
Message ID: 429     Entry time: Wed May 23 13:15:47 2018
Author: megumi 
ExpNbr: e744 
Type: DAQ 
Category: General 
Status: Fixed 
Target-Source: N/A 
Subject: Time calibration for TDC (EXL) 
Time calibrator setting
Range 5.12 us
Period 160 ns


RUN #406 : Time calibration for TDC ch 1,2,3,4,5,6,7,8
ch2 is missing...

RUN #407 : Time calibration for TDC ch 9,10,11,12,13,14,15,16

RUN #408 : Time calibration for TDC ch 17, 31, 32 (PPT, EXL17, EXL18)
but i cannot find those entry in the basic_online...


The calib parameters for EXL detector (energy+time) are:

EXL_E1 -71.1150 0.668983
EXL_E2 132.36 0.519247
EXL_E3 71.2 0.5649
EXL_E4 -58.9582 0.600488
EXL_E5 72.8547 0.579928
EXL_E6 -56.2703 0.598377
EXL_E7 91.2014 0.540216
EXL_E8 95.1007 0.488096
EXL_E9 9.26351 0.610848
EXL_E10 -2.42136 0.560869
EXL_E11 86.8976 0.503247
EXL_E12 105.457 0.464832
EXL_E13 45.8667 0.848081
EXL_E14 68.9514 0.792648
EXL_E15 2.84729 0.799
EXL_E16 18.4952 0.426236
EXL_E17 18.7380 0.485055
EXL_E18 116.032 0.492694
EXL_T1 0 1.73118
EXL_T2 0 1
EXL_T3 0 1.72242
EXL_T4 0 1.7302
EXL_T5 0 1.74106
EXL_T6 0 1.71348
EXL_T7 0 1.73504
EXL_T8 0 1.73337
EXL_T9 0 1.72332
EXL_T10 0 1.75605
EXL_T11 0 1.7177
EXL_T12 0 1.74387
EXL_T13 0 1.74781
EXL_T14 0 1.72464
EXL_T15 0 1.72852
EXL_T16 0 1.72436
EXL_T17 0 1
EXL_T18 0 1
Attachment 1: Capture_du_2018-05-23_13-29-34.png  46 kB  Uploaded Wed May 23 14:30:03 2018  | Hide | Hide all
Capture_du_2018-05-23_13-29-34.png

ELOG Home Page