Fixede748 Thu Jun 29 23:26:10 2017 Valérie LapouxRUNGeneralEmptyALL CALIMERO Time Calibration MUVI1
29 JUNE 2017
CONDITIONS FOR CALIMERO CALIBRATIONS
Time calibrator Period 20ns ; range 512 ns
storage /data/e748X/e748/acquisition/run
--------------------------------------------------------------------------
RUN 0035 started 22h01; stop 22:35
RUN 0035 (run_0035.dat.29-06-17_22h01m28s.1) started 22h35 stop at 22h50
MUVI 1 TRIGGER IN GMT: MM1, MM2, MM3, MM4
MATE validated: STRIP-X T (enable MUFEEX, disable SiLi )

1048576000 29 juin 22:35 run_0035.dat.29-06-17_22h01m28s
431554560 29 juin 22:50 run_0035.dat.29-06-17_22h01m28s.1


The time to calibrate all stripXT is 50 minutes, when the statistics requested for one spectrum is 100000.

NB: DSSD Telescope 2 tripped round 23h50 29 june !!! I ~ 4.9 µA
-------------------------------------------------------------------------
RUN 0038 started 23h03 ; stop 00H14 30 juin
MUVI 1 TRIGGER IN GMT: MM1, MM2, MM3, MM4
MATE validated: STRIP-Y T (enable MUFEEX, disable CsI)
Exxx 1048576000 29 juin 23:28 run_0038.dat.29-06-17_23h03m18s
Exxx 1048576000 29 juin 23:53 run_0038.dat.29-06-17_23h03m18s.1
Exxx 846856192 30 juin 00:14 run_0038.dat.29-06-17_23h03m18s.2

--------------------------------------------------------------------------
Attachment 1: CalimeroRunControl.png
CalimeroRunControl.png
Attachment 2: ConfigCalimeroStat.png
ConfigCalimeroStat.png
Attachment 3: CalibTmuvi1Yperiod20nsrange600ns.png
CalibTmuvi1Yperiod20nsrange600ns.png
Attachment 4: TimeMust2X_MUVI1_uncalib.png
TimeMust2X_MUVI1_uncalib.png
Attachment 5: TimeMust2Y_MUVI1_uncalib.png
TimeMust2Y_MUVI1_uncalib.png
Fixede748 Fri Jun 30 00:33:36 2017 Valérie LapouxRUNGeneralEmptyALL CALIMERO Time Calibration MUVI2
30 JUNE 2017
CONDITIONS FOR CALIMERO CALIBRATIONS
Time calibrator Period 20ns ; range 512 ns
storage /data/e748X/e748/acquisition/run
--------------------------------------------------------------------------
RUN 0039 started 0h19 ; stop 00H45

MUVI 2 TRIGGER IN GMT: MM5, MM6, MM7, MM8
BUT ALL MUVI2 MATE at 300 ns !!!!
MATE validated: STRIP-X T (enable MUFEEX, disable SiLi )

The time to calibrate all stripXT is 25 minutes, when the statistics requested for one spectrum is 50000.

Exxx 761004032 30 juin 00:45 run_0039.dat.30-06-17_00h19m45s
-------------------------------------------------------------------------
Attachment 1: CalibTimeMUVI2stripXT.png
CalibTimeMUVI2stripXT.png
Attachment 2: SpectresMUVI2stripXT300ns.png
SpectresMUVI2stripXT300ns.png
Fixede748 Fri Jun 30 01:01:08 2017 Valérie LapouxRUNGeneralEmptyALL CALIMERO Time Calibration MUVI2 GOOD RUNS 600ns
RANGE TAC MUST2 600ns
CALIMERO TIME CALIBRATOR PERIOD 20ns; Range 512ns

RUN 40 started 00H53 ; stop 30 juin 01:19
MUVI 2 TRIGGER IN GMT: MM5, MM6, MM7, MM8
MATE validated: STRIP-X T (enable MUFEEX, disable SiLi)


---------------------------------------------------------
RUN 41 started ; stop 30 juin stop 31st of june 01:47
MUVI 2 TRIGGER IN GMT: MM5, MM6, MM7, MM8
MATE validated: STRIP-Y T (enable MUFEEY, disable CsI)

---------------------------------------------------------
Attachment 1: TimeMust2X_MUVI2_uncalib.png
TimeMust2X_MUVI2_uncalib.png
Attachment 2: TimeMust2Y_MUVI2_uncalib.png
TimeMust2Y_MUVI2_uncalib.png
Fixede748 Fri Jun 30 02:00:44 2017 e748MUST2HardwareN/AWarming up of detector started
All LV and HT off, vaccumm at 1.3e-5 mbar, starting warm up sequence.
Fixede748 Fri Jun 30 11:09:59 2017 FreddyOFFLINEGeneral Analysis of DSSD Energy Calibration - alpha source
We made a calibration with the last alpha source runs:
-run 19 for T1-2-3-4
-run 29 for T5 and T8
-run 31 for T6 and T7

Here are some plots of the analysed runs using this calibration.
In general one can see that telescope 2 has the worst resolution, has an EX energy shifted. It is also the detector with the largest (increasing) leakage current. It has to be investigated in more details...

Calibration summary for each detector can be found in:
/home/e748/analysis/nptool/Projects/e748/Calibration/Energy/Calibration/Juin16_CalE
Attachment 1: run19_Summary_EX.pdf
run19_Summary_EX.pdf
Attachment 2: run19_Summary_EY.pdf
run19_Summary_EY.pdf
Fixede748 Fri Jun 30 12:24:17 2017 Valérie LapouxDAQGeneral DAQ Parameters: TAC, Caviar, LISE D4, D6, Caviar
Attachment 1: DASParamVXIMust2CatsTACLise.png
DASParamVXIMust2CatsTACLise.png
Attachment 2: DASParamVXIChioQDC.png
DASParamVXIChioQDC.png
Attachment 3: DASParamVXIChioADClisepar.png
DASParamVXIChioADClisepar.png
Fixede748 Fri Jun 30 16:49:49 2017 Valérie LapouxDAQGeneral GMT triggers and chronograph
Configurations for the GMT inputs.
30 June 2017 pm
all Must2 telescopes,
divided inputs: Cats 1 (IN9) and Cats2 (IN10); Plast (IN11); ChIo (IN12);
TriggerLISE (IN13).
GMT chronograph FAG 100ns; CT 5µs.
Attachment 1: DASConfigTriggerGMT.png
DASConfigTriggerGMT.png
Attachment 2: ChronogrammeGMT30juinFAG100nsCT5µs.png
ChronogrammeGMT30juinFAG100nsCT5µs.png
Fixede748 Fri Jun 30 16:55:04 2017 Valérie LapouxDAQGeneral Run control for global DAQ with NUMEXO
The run start/stop sequence for the global DAQ including the NUMEXO:

I. ssh e748chio@ganp976
pw (same as for the experiment)
II. start_acq e748chio
-->the RC window of the e748chio is opened
III. START (on the RC e748chio)
IV. START (on the RC e748)
V. STOP (on the RC e748)
VI. STOP (on the RC e748chio)
==================================================================================
Attachment 1: RunControlAll748ModeMonitoring.png
RunControlAll748ModeMonitoring.png
Attachment 2: NarvalRunControlAllE748.png
NarvalRunControlAllE748.png
Fixede748 Fri Jun 30 17:53:35 2017 Valérie LapouxDAQGeneral Scalers parameters U2M
Attachment 1: Actionse748ganlx11withU2M.png
Actionse748ganlx11withU2M.png
Attachment 2: ScalerAnalyzerU2M.png
ScalerAnalyzerU2M.png
Fixede748 Fri Jun 30 20:46:16 2017 Valérie LapouxTARGETGeneral TARGET configuration
List of the reaction target in the chamber from bottom to up:

6. EMPTY FRAME (no frame)
5. CD2 2.5 mg/cm2
4. CD2 1.5 mg/cm2
3. CD2 2.5 mg/cm2
2. CD2 1.5 mg/cm2
1. MASK

MASK viewed from the beam coming to the target position :
cf photograph of entry ELOG Id=83 https://caeelog.in2p3.fr/MUST2/83
____________________________
----*-----*-----*------
----------*-------------
----*-----*--*--*---
-------*-----*--------
----*-----*-----*------
_________________________


SYSTEM of 3 blocks to fix the target position :
I small one
II long one III long one; II = III

To have the target n°1 mask: no block
To have target n°2 block I
target n°3: block II
target n°4: blocks I+II
target n°5: blocks II+III
target n°6: blocks I+II+III
Fixede748 Sat Jul 1 09:27:46 2017 Adrien MattaOTHERGeneralN/ASHIFT TABLE

Fixede748 Sat Jul 1 10:47:18 2017 Adrien MattaBEAMGeneralN/APrimary beam energy measurement
PCP delivered the primary beam energy measurement
Attachment 1: IMG_1984.JPG
IMG_1984.JPG
Fixed  Sat Jul 1 12:45:25 2017 Anastasia CATSGeneral CATS Calibrated
run_0026 CATS 1 X Y
run_0027 CATS 2 X Y
Attachment 1: cats_calibrated.png
cats_calibrated.png
Fixede748 Sat Jul 1 14:32:02 2017 Valérie LapouxDAQGeneral Scalers U2M, parameters
U2M configuration +Actions ganlx11

The signals for the scalers are converted from NIM to ECL in a 16 channel module NIM-ECL.
The cable is PHYSICALLY connected from the NIM-ECL module to the U2M on Groups 1 & 2.
Normally we should read these scalers on the U2M from channel 1 to 16 BUT
we found that the good channels are running on channels 17 to 32. See below.
We have defined the actions for all possible channels of the U2M registers 1 to 16 (Groups 1 and 2), and 17 to 32
(Groups 3 and 4)
Attachment 1: ScalersU2Mok.png
ScalersU2Mok.png
Attachment 2: CompilActionsganlx11ScalerGr1to4..png
CompilActionsganlx11ScalerGr1to4..png
Fixede748 Sat Jul 1 14:45:17 2017 Valérie LapouxDAQGeneral Parameters for correlation checkings
The parameters to be used for the checking of the correlations between crates/VME/VXI and good running of the merging
conditions of the different DAQs are :
- for MUST2 VXI with the GMT: GATCONF
- for CATS VXI: DATATRIG
- for CHIO VXI: DATATRIG_CHIO
- for CAVIAR crate: CONFDEV
- for AGAVA: CONFDEV_AGAVA

Check correlations on the following bidim:
parameter T_PL_CATS1 coded in ADC VXI MUST2
parameter T_PLch_CATS1 coded in ADC VXI CHIO

check T_CATS1_CAV
Fixede748 Sat Jul 1 15:12:01 2017 Valérie LapouxONLINEHardware Conditions for Bidiv and TAC 1st July 15pm
(Update the file CONDTIONS748.txt during the experiment)

JULY 1st 15pm

Bidiv = 1 for CATS1 and 2
Bidiv = 10 for Plast and ChIo

TAC ranges

START STOP RANGE PARAMETER ADDRESS VXI MODULE
-------------------------------------------------------------------
-------------------------------------------------------------------
CATS1_FAG CAVIAR 1µs T_CATS1_CAV ADC VXI MUST2 add=19
CATS1_FAG CATS2_FAG 500ns T_CATS1_CAV ADC VXI MUST2 add=20
OU_MUVI CATS1_FAG 500ns T_MUVI_CATS1 ADC VXI MUST2 add=21
PLAST_FAG CATS1_FAG 1µs T_PL_CATS2 ADC VXI MUST2 add=22
PLAST_FAG CATS1_FAG 1µs T_PL_CATS1 ADC VXI MUST2 add=23
-------------------------------------------------------------------
PLAST_FAG CATS1_FAG 1µs T_PLch_CATS1 ADC VXI CHIO add=19
PLAST_FAG CHIO 1µs T_PL_CHIO ADC VXI CHIO add=3
-------------------------------------------------------------------
-------------------------------------------------------------------
Fixed  Sat Jul 1 17:09:04 2017 e748MUST2General TIME CAL CHECK
run_0040_CalMust2Histos.root
Attachment 1: must2_time_cal_run40.png
must2_time_cal_run40.png
Fixede748 Sat Jul 1 22:16:46 2017 e748DAQGeneralN/AProblem of Merge
The DAQ was not merging properly.
We figured out that the centrum was goiging out of sync when the run was stopped.
Fred added in the action file the reset of the event number in the INIT RUN block.
First few test seems to have solved the issue.
Fixede748 Sun Jul 2 03:46:11 2017 e748OTHERHardware UPDATE OF TAC settings
Here are several changes made during the night to optimize timing for TACs:

TAC PL-CATS1
START: CATS1 val FAG
STOP: PL no val

TAC PL-CATS2
START: CATS2 val FAG
STOP: PL no val

TAC CAVIAR - CATS1
START: CATS1 val FAG
STOP: CAVIAR delayed of 550 ns
range: 1 us

TAC CATS1-CATS2
CATS2 delayed of 33 ns
range: 200 ns
now channel 29 in ADC (starting from 1)

TAC PL CHIO:
START: PL val GAMER CHIO
STOP: CHIO no val
Fixede748 Sun Jul 2 04:58:36 2017 e748RUNGeneralN/ARun 74: MASK IN
Starting Run 74 with trigger plastic and MASK at target position.

Intensity is set around 6-10kHz

ELOG Home Page