Status |
ExpNbr |
Date |
Author |
Type |
Category |
Target-Source |
Subject |
Ongoing | e744 |
Mon Mar 26 15:07:06 2018 |
e744 : Valerian et Louis | MUST2 | Hardware | 3-alpha | Energy vs Strip for T6 et T7 |
Weird signal on StripX of T6... might be the copper oxyde projections making a short-circuit
EDIT 27/03/18 : The problem seen on Telescope 6 might be due to either some Asics Problem, or due to some dirt, the current reason in not known currently. The safest way would be to remove the telescope completely and replace it for Daisuke's and Olivier's experiments. |
Attachment 1: StripXE_vs_StripNbr_T6.pdf
|
|
Attachment 2: StripXE_vs_StripNbr_T6_zoom.pdf
|
|
Attachment 3: StripYE_vs_StripNbr_T6.pdf
|
|
Pinned | e744 |
Mon Mar 26 11:44:27 2018 |
e744 : Valerian | OTHER | General | | Current Elog state |
Currently we do not have access to the experiment number. To write an entry for e744 the nickname TEST will be used. |
Fixed | e744 |
Mon Mar 26 11:46:43 2018 |
e744 : Valerian | RUN | General | 3-alpha | Tests runs Ganacq log |
(15:51:33 - 19/03/2018) INFO - rcc_gui - Started run #1
(16:22:01 - 19/03/2018) INFO - rcc_gui - Stopped run #1
(16:25:05 - 19/03/2018) INFO - rcc_gui - Started run #2
Pedestal aligned T1-4
(16:31:10 - 19/03/2018) INFO - rcc_gui - Stopped run #2
(16:32:26 - 19/03/2018) INFO - rcc_gui - Started run #3
realigned the pedestal on T1-4
(16:33:48 - 19/03/2018) INFO - rcc_gui - Stopped run #3
(16:41:52 - 19/03/2018) INFO - rcc_gui - Started run #4
Set polarity of T1-4 correctly and set again the pedestals
(16:49:34 - 19/03/2018) INFO - rcc_gui - Stopped run #4
(16:53:42 - 19/03/2018) INFO - rcc_gui - Started run #5
(16:55:20 - 19/03/2018) INFO - rcc_gui - Stopped run #5
(16:56:40 - 19/03/2018) INFO - rcc_gui - Started run #6
(16:57:11 - 19/03/2018) INFO - rcc_gui - Stopped run #6
(16:58:04 - 19/03/2018) INFO - rcc_gui - Started run #7
(16:58:27 - 19/03/2018) INFO - rcc_gui - Stopped run #7
(17:06:47 - 19/03/2018) INFO - rcc_gui - Stopped run #8
(17:08:44 - 19/03/2018) INFO - rcc_gui - Started run #9
(17:08:49 - 19/03/2018) INFO - rcc_gui - Started run #8
(17:13:44 - 19/03/2018) INFO - rcc_gui - Stopped run #9
(17:14:56 - 19/03/2018) INFO - rcc_gui - Started run #10
(17:15:44 - 19/03/2018) INFO - rcc_gui - Stopped run #10
(17:17:52 - 19/03/2018) INFO - rcc_gui - Started run #11
(17:18:16 - 19/03/2018) INFO - rcc_gui - Stopped run #11
(17:20:54 - 19/03/2018) INFO - rcc_gui - Started run #12
(17:26:05 - 19/03/2018) INFO - rcc_gui - Stopped run #12
(17:26:56 - 19/03/2018) INFO - rcc_gui - Started run #13
(17:32:16 - 19/03/2018) INFO - rcc_gui - Stopped run #13
(17:32:55 - 19/03/2018) INFO - rcc_gui - Started run #14
(17:34:05 - 19/03/2018) INFO - rcc_gui - Stopped run #14
(17:35:25 - 19/03/2018) INFO - rcc_gui - Started run #15
(18:20:40 - 19/03/2018) INFO - rcc_gui - Stopped run #15
(18:21:00 - 19/03/2018) INFO - rcc_gui - Started run #16
(18:23:36 - 19/03/2018) INFO - rcc_gui - Stopped run #16
(18:23:52 - 19/03/2018) INFO - rcc_gui - Started run #17
(18:30:52 - 19/03/2018) INFO - rcc_gui - Stopped run #17
(18:31:42 - 19/03/2018) INFO - rcc_gui - Started run #18
(18:37:11 - 19/03/2018) INFO - rcc_gui - Stopped run #18
(18:37:43 - 19/03/2018) INFO - rcc_gui - Started run #19
(18:39:44 - 19/03/2018) INFO - rcc_gui - Stopped run #19
(18:40:08 - 19/03/2018) INFO - rcc_gui - Started run #20
(18:43:10 - 19/03/2018) INFO - rcc_gui - Stopped run #20
(18:44:12 - 19/03/2018) INFO - rcc_gui - Started run #21
(18:45:31 - 19/03/2018) INFO - rcc_gui - Stopped run #21
(09:19:38 - 20/03/2018) INFO - rcc_gui - Stopped run #22
(09:19:46 - 20/03/2018) INFO - rcc_gui - Started run #22
(09:21:46 - 20/03/2018) INFO - rcc_gui - Started run #23
(09:23:22 - 20/03/2018) INFO - rcc_gui - Stopped run #23
(09:23:56 - 20/03/2018) INFO - rcc_gui - Started run #24
(09:25:31 - 20/03/2018) INFO - rcc_gui - Stopped run #24
(09:29:18 - 20/03/2018) INFO - rcc_gui - Stopped run #25
(09:31:08 - 20/03/2018) INFO - rcc_gui - Started run #26
(09:31:14 - 20/03/2018) INFO - rcc_gui - Started run #25
(09:32:23 - 20/03/2018) INFO - rcc_gui - Stopped run #26
(09:55:33 - 20/03/2018) ERROR - rcc_gui - Operation forbidden - Storage mode can be changed only in READY state
(09:56:20 - 20/03/2018) INFO - rcc_gui - Started run #26
source alpha, en G3, piedestaux suppression set
(14:24:46 - 20/03/2018) INFO - rcc_gui - Stopped run #26
(14:25:43 - 20/03/2018) INFO - rcc_gui - Started run #27
follow up, same condition as run 26, stopped daq for analysis.
(09:42:36 - 21/03/2018) INFO - rcc_gui - Stopped run #27
(18:06:46 - 21/03/2018) INFO - rcc_gui - Started run #28
(18:09:02 - 21/03/2018) INFO - rcc_gui - Stopped run #28
(18:10:33 - 21/03/2018) INFO - rcc_gui - Started run #29
(18:11:47 - 21/03/2018) INFO - rcc_gui - Stopped run #29
(18:16:59 - 21/03/2018) INFO - rcc_gui - Started run #30
(18:18:15 - 21/03/2018) INFO - rcc_gui - Stopped run #30
(18:25:10 - 21/03/2018) INFO - rcc_gui - Started run #31
(18:26:51 - 21/03/2018) INFO - rcc_gui - Stopped run #31
(18:37:07 - 21/03/2018) INFO - rcc_gui - Started run #32
(18:39:04 - 21/03/2018) INFO - rcc_gui - Stopped run #32
(18:41:49 - 21/03/2018) INFO - rcc_gui - Started run #33
(18:49:13 - 21/03/2018) INFO - rcc_gui - Stopped run #33
(18:53:08 - 21/03/2018) INFO - rcc_gui - Started run #34
(18:53:42 - 21/03/2018) INFO - rcc_gui - Stopped run #34
(18:56:02 - 21/03/2018) INFO - rcc_gui - Started run #35
(18:57:06 - 21/03/2018) INFO - rcc_gui - Stopped run #35
(10:22:37 - 22/03/2018) INFO - rcc_gui - Started run #37
Start source 3a MUVI2 1,2 (MM5 & MM6)
(11:24:12 - 22/03/2018) INFO - rcc_gui - Stopped run #37
(11:25:45 - 22/03/2018) INFO - rcc_gui - Started run #38
correction thresolds Muvi2
(12:26:38 - 22/03/2018) INFO - rcc_gui - Stopped run #38
(12:46:48 - 22/03/2018) INFO - rcc_gui - Started run #39
(12:49:47 - 22/03/2018) INFO - rcc_gui - Stopped run #39
(12:59:48 - 22/03/2018) INFO - rcc_gui - Started run #40
(15:44:26 - 22/03/2018) INFO - rcc_gui - Stopped run #40
(09:11:26 - 23/03/2018) INFO - rcc_gui - Started run #41
test
(09:13:41 - 23/03/2018) INFO - rcc_gui - Stopped run #41
(09:13:48 - 23/03/2018) ERROR - rcc_gui - Operation forbidden - Storage mode can be changed only in READY state
(09:41:06 - 23/03/2018) INFO - rcc_gui - Started run #41
MM5 connected to MM8
MM6 connected to MM5
correct piedestal
3 pics alpha source
(14:02:04 - 23/03/2018) INFO - rcc_gui - Stopped run #41
(14:25:59 - 23/03/2018) INFO - rcc_gui - Started run #42
channel MM5 = real MM7
channel MM6 = real MM6
alpha source
(14:31:33 - 23/03/2018) INFO - rcc_gui - Stopped run #42
(14:33:42 - 23/03/2018) INFO - rcc_gui - Started run #43
same after change in the piedestals
(15:54:10 - 23/03/2018) INFO - rcc_gui - Stopped run #43 |
Fixed | e744 |
Mon Mar 26 14:20:22 2018 |
e744 : Valerian | MUST2 | Hardware | 3-alpha | Bidimensional graphs for Telescope 7 and 6 |
WARNING T5 == T7
EDIT 27/03/18 : WARNING X and Y are inverted, this entry should be ignored see entry : Bidim for T1 T3 T4 T5 T6 T7 T8 |
Attachment 1: T6_3alpha.pdf
|
|
Attachment 2: T7_3alpha.pdf
|
|
Ongoing | TEST |
Tue Mar 27 10:47:39 2018 |
e744 : Valerian | MUST2 | Hardware | 3-alpha | Choice of DSSSDs |
|
Ongoing | e744 |
Tue Mar 27 11:11:04 2018 |
e744 : Valerian | MUST2 | Hardware | 3-alpha | Choice of DSSSDs |
Different plots of Strip channel vs Strip number for X and Y in order to make our choice |
Attachment 1: StripXE_vs_StripNbr_T1.pdf
|
|
Attachment 2: StripYE_vs_StripNbr_T1.pdf
|
|
Attachment 3: StripXE_vs_StripNbr_T3.pdf
|
|
Attachment 4: StripYE_vs_StripNbr_T3.pdf
|
|
Attachment 5: StripXE_vs_StripNbr_T4.pdf
|
|
Attachment 6: StripYE_vs_StripNbr_T4.pdf
|
|
Attachment 7: StripXE_vs_StripNbr_T5.pdf
|
|
Attachment 8: StripYE_vs_StripNbr_T5.pdf
|
|
Attachment 9: StripXE_vs_StripNbr_T6.pdf
|
|
Attachment 10: StripYE_vs_StripNbr_T6.pdf
|
|
Attachment 11: StripXE_vs_StripNbr_T7.pdf
|
|
Attachment 12: StripYE_vs_StripNbr_T7.pdf
|
|
Attachment 13: StripXE_vs_StripNbr_T8.pdf
|
|
Attachment 14: StripYE_vs_StripNbr_T8.pdf
|
|
Fixed | e744 |
Tue Mar 27 16:26:29 2018 |
e744 : Valerian | MUST2 | General | 3-alpha | Bidim for T1 T3 T4 T5 T6 T7 T8 |
|
Attachment 1: StripX_vs_StripY_T1.pdf
|
|
Attachment 2: StripX_vs_StripY_T3.pdf
|
|
Attachment 3: StripX_vs_StripY_T4.pdf
|
|
Attachment 4: StripX_vs_StripY_T5.pdf
|
|
Attachment 5: StripX_vs_StripY_T6.pdf
|
|
Attachment 6: StripX_vs_StripY_T7.pdf
|
|
Attachment 7: StripX_vs_StripY_T8.pdf
|
|
Ongoing | e744 |
Tue Mar 27 17:22:24 2018 |
e744 : Valerian | MUST2 | Hardware | 3-alpha | Choosing the DSSSDs |
We can see that the DSSSDs on T1(CsI) T3(CsI) T4(CsI) and T5(SiLi) are in good shape (cf :Bidim for T1 T3 T4 T5 T6 T7 T8 ).
As for now, we would like to keep the telescope as is. M2C should be moved tomorrow (28/03/18).
After that we would like to use the two spare DSSSDs available on both T2 and on the O degree telescope (now called T5(CsI)).
If the spare DSSSDs are judged not be good enough for the experiment, we will swap current T5(SiLi) DSSDs on the 0 degree Telescope T5(CsI). |
Ongoing | e744 |
Wed Mar 28 13:21:32 2018 |
e744 : Valerian | MUST2 | Hardware | 3-alpha | Choosing the DSSSDs |
e744 : Valerian wrote: | We can see that the DSSSDs on T1(CsI) T3(CsI) T4(CsI) and T5(SiLi) are in good shape (cf :Bidim for T1 T3 T4 T5 T6 T7 T8 ).
As for now, we would like to keep the telescope as is. M2C should be moved tomorrow (28/03/18).
After that we would like to use the two spare DSSSDs available on both T2 and on the O degree telescope (now called T5(CsI)).
If the spare DSSSDs are judged not be good enough for the experiment, we will swap current T5(SiLi) DSSDs on the 0 degree Telescope T5(CsI). |
Which telescope should we take for T5? T7 or T6? |
Ongoing | e744 |
Wed Mar 28 16:35:01 2018 |
e744 : Valerian | MUST2 | Hardware | 3-alpha | Choosing the DSSSDs |
e744 : Valerian wrote: |
e744 : Valerian wrote: | We can see that the DSSSDs on T1(CsI) T3(CsI) T4(CsI) and T5(SiLi) are in good shape (cf :Bidim for T1 T3 T4 T5 T6 T7 T8 ).
As for now, we would like to keep the telescope as is. M2C should be moved tomorrow (28/03/18).
After that we would like to use the two spare DSSSDs available on both T2 and on the O degree telescope (now called T5(CsI)).
If the spare DSSSDs are judged not be good enough for the experiment, we will swap current T5(SiLi) DSSDs on the 0 degree Telescope T5(CsI). |
Which telescope should we take for T5? T7 or T6? |
Looking at the previous Calimero tests Adrien did during his experiment, neither telescope are good as is... the T7 has no time calibration and T6 might have some Asics problem...
We can either use T6 and check if the problem we saw on it's DSSDs are due to some electronics problem or use a completly different telescope from the spare we have...
EDIT 29/03/18 : After discussion with Laurent the option to use a new DSSD on T6 seems more appropriate, still ongoing. |
Attachment 1: TimeMust2X_MUVI2_uncalib.png
|
|
Attachment 2: TimeMust2Y_MUVI2_uncalib.png
|
|
Attachment 3: SpectresMUVI2stripXT300ns.png
|
|
Fixed | e744 |
Tue Apr 3 10:44:38 2018 |
e744 : Valérian | MUST2 | Hardware | | Update on Must2 telescopes |
For the next day, the plan is to check the DSSD's connections of T6 & T7 followed by an alpha run, if the problem seen on T6 are not resolved, we will change the DSSD of T6 and re-do another alpha run, the last option would be to change the Muffee card.
Just for a quick visual update, telescopes 5&8 are dismounted and a new DSSD is mounted on T2 as you can see ! |
Attachment 1: 20180403_103732.jpg
|
|
Ongoing | e744 |
Tue Apr 3 15:30:49 2018 |
e744 : Valérian | MUST2 | Hardware | | Cabling of T6 & T7 |
After checking the cable of T6 & T7 it seems that there were in fact an inversion during experiment e748. T6 is the bottom one, and T7 the top one.
During e748, it seems that there were some difference regarding the position, between the hardware and software position...
If it was the case, it would mean that it is T6 that has the time calibration problem, not T7.
re-
In conclusion, it is T6 that has both the time calibration problem on X and Y, and the weird signal seen during the calibration.
EDIT 4/04/18 : For the experiment e748 and before the time calibration, the inversion had been made, as a conclusion what was previously stated is wrong, it is T7 that has no time calibration... Anyhow, wee will re-do the time calibration for T6 and T7 to check if the problem are still present. |
Attachment 1: Inversion_between_telescopes.pdf
|
|
Ongoing | e744 |
Wed Apr 4 17:49:05 2018 |
e744 : Valérian | EXL-PPT | Hardware | | Update on EXL |
The EXL detector has been mounted, it is very close to the target ~4cm and doesn't do any shadow on the M2 telescopes. But it isn't at 90° anymore. The cable have been plugged-in (cf photos). With a new mapping of the detector (cf drawing). |
Attachment 1: 20180404_113303.jpg
|
|
Attachment 2: 20180404_113312.jpg
|
|
Attachment 3: 20180404_135324.jpg
|
|
Attachment 4: 20180404_135334.jpg
|
|
Attachment 5: EXL_cables.pdf
|
|
Attachment 6: Mapping_of_EXL.pdf
|
|
Fixed | e744 |
Tue May 22 22:33:09 2018 |
e744 | MUST2 | Software | N/A | Run #363 Calimero T1-T4 strips X again with threshold at 50% (same as 40%) |
Run #363
NB: Thresholds are the ones on the pulser amplitude to inject the signal (Calimero Pulser interface on Geco). see snapshots on the Calimero summary.
Calimero with 50% thresholds on T4. Same spectra as with the thresholds @40%. I think T4 is triggering on cross-talk, so when the thresholds it's high it's ok. |
Attachment 1: T1T4_Xstrips_run363.png
|
|
Fixed | e744 |
Tue May 22 22:50:47 2018 |
e744 | MUST2 | Software | N/A | Run #365 Calimero strips Y T1-T4 100% Threshold |
Run #365
Calimero strips Y T1-T4
100% threshold on T4
Something is wrong with the masking?! |
Attachment 1: T1T4_Ystrips_run364.png
|
|
Fixed | e744 |
Wed May 23 00:30:34 2018 |
e744 | EXL-PPT | General | N/A | RUN #402, EXL PPT trigger |
RUN #402
start exl ppt run for checking coincidence
exl ch 17 put in to adc2 ch 32 |
Fixed | e744 |
Wed May 23 18:20:59 2018 |
e744 | MUST2 | General | N/A | Test Calimero Run 425 |
Started run #425 Calimero NEW XT T1toT4
ampl Pulser 12MEV; thr for T4 1 MeV
problem on data taking |
Fixed | e755 |
Sat Jun 30 20:08:27 2018 |
didier, takeshi, daisuke | RUN | General | Cryo-LH2 | RUN 199 37C + liq. H |
|
Attachment 1: scaler_2018-06-30_19h41m59s.png
|
|
Attachment 2: visu_2018-06-30_19h42m32s.png
|
|
Attachment 3: visu_2018-06-30_20h04m35s.png
|
|
Attachment 4: visu_2018-06-30_20h04m46s.png
|
|
Attachment 5: visu_2018-06-30_20h04m51s.png
|
|
Attachment 6: visu_2018-06-30_20h04m59s.png
|
|
Attachment 7: visu_2018-06-30_20h05m12s.png
|
|
Attachment 8: visu_2018-06-30_20h05m17s.png
|
|
Attachment 9: visu_2018-06-30_20h05m23s.png
|
|
Attachment 10: visu_2018-06-30_20h05m29s.png
|
|
Attachment 11: visu_2018-06-30_20h05m35s.png
|
|
Attachment 12: visu_2018-06-30_20h05m44s.png
|
|
Attachment 13: visu_2018-06-30_20h05m50s.png
|
|
Attachment 14: visu_2018-06-30_20h06m05s.png
|
|
Attachment 15: visu_2018-06-30_20h06m13s.png
|
|
Attachment 16: visu_2018-06-30_20h06m20s.png
|
|
Attachment 17: visu_2018-06-30_20h06m26s.png
|
|
Attachment 18: visu_2018-06-30_20h06m31s.png
|
|
Attachment 19: visu_2018-06-30_20h06m39s.png
|
|
Attachment 20: visu_2018-06-30_20h06m45s.png
|
|
Attachment 21: visu_2018-06-30_20h06m54s.png
|
|
Attachment 22: visu_2018-06-30_20h07m04s.png
|
|
Attachment 23: visu_2018-06-30_20h07m10s.png
|
|
Attachment 24: visu_2018-06-30_20h07m20s.png
|
|
Attachment 25: visu_2018-06-30_20h07m25s.png
|
|
Attachment 26: visu_2018-06-30_20h07m33s.png
|
|
Attachment 27: visu_2018-06-30_20h07m45s.png
|
|
Attachment 28: visu_2018-06-30_20h07m55s.png
|
|
Fixed | e738 |
Fri Jul 13 22:00:59 2018 |
didier, nori, takeshi, shumpei, hide, daisuke | RUN | General | Cryo-LH2 | RUN 376: 12C first run |
12C + liquid H.
start 21h44
stop 22h43 |
Attachment 1: scaler_2018-07-13_21h59m16s.png
|
|
Attachment 2: screenshot_2018-07-13_21h54m55s.png
|
|
Attachment 3: visu_2018-07-13_21h54m41s.png
|
|
Attachment 4: visu_2018-07-13_21h58m06s.png
|
|
Attachment 5: visu_2018-07-13_21h58m08s.png
|
|
Attachment 6: visu_2018-07-13_21h58m10s.png
|
|
Attachment 7: visu_2018-07-13_21h58m13s.png
|
|
Attachment 8: visu_2018-07-13_21h58m15s.png
|
|
Attachment 9: visu_2018-07-13_21h58m17s.png
|
|
Attachment 10: visu_2018-07-13_21h58m23s.png
|
|
Attachment 11: visu_2018-07-13_21h58m28s.png
|
|
Attachment 12: visu_2018-07-13_21h58m32s.png
|
|
Attachment 13: visu_2018-07-13_21h58m36s.png
|
|
Attachment 14: visu_2018-07-13_21h58m41s.png
|
|
Attachment 15: visu_2018-07-13_21h58m23s.png
|
|
Attachment 16: visu_2018-07-13_21h58m28s.png
|
|
Attachment 17: visu_2018-07-13_21h58m32s.png
|
|
Attachment 18: visu_2018-07-13_21h58m36s.png
|
|
Attachment 19: visu_2018-07-13_21h58m41s.png
|
|
Attachment 20: visu_2018-07-13_21h58m45s.png
|
|
Attachment 21: visu_2018-07-13_21h58m49s.png
|
|
Attachment 22: visu_2018-07-13_21h58m54s.png
|
|
Fixed | e738 |
Tue Jul 10 21:26:48 2018 |
didier, daisuke | RUN | General | Cryo-LH2 | RUN 334 |
9C + liquid H. Probably nobody cares this post right now, but the beam is back.
21h00 the beam back to LISE.
21h03 start. Tune the wien filter 3.0 to 0.0 kV to optimize the transmission from CATS to PLASTIC (with visual scaler). TOF spectrum is the same as before.
21h32 1.7 electric micro A.
22h20 Wien filter 0 to 1.0 kV. Scaler Plastic/CATS2 ratio is the highest (93%) with this setting.
23h11 stop |
Attachment 1: scaler_2018-07-10_21h21m21s.png
|
|
Attachment 2: visu_2018-07-10_21h23m07s.png
|
|
Attachment 3: visu_2018-07-10_21h23m10s.png
|
|
Attachment 4: visu_2018-07-10_21h23m12s.png
|
|
Attachment 5: visu_2018-07-10_21h23m18s.png
|
|
Attachment 6: visu_2018-07-10_21h23m21s.png
|
|
Attachment 7: visu_2018-07-10_21h23m23s.png
|
|
Attachment 8: visu_2018-07-10_21h23m28s.png
|
|
Attachment 9: visu_2018-07-10_21h23m38s.png
|
|
Attachment 10: visu_2018-07-10_21h23m50s.png
|
|
Attachment 11: visu_2018-07-10_21h23m53s.png
|
|
Attachment 12: visu_2018-07-10_21h23m56s.png
|
|
Attachment 13: visu_2018-07-10_21h23m59s.png
|
|
Attachment 14: visu_2018-07-10_21h24m08s.png
|
|
Attachment 15: visu_2018-07-10_21h24m11s.png
|
|
Attachment 16: screenshot_2018-07-10_22h26m19s.png
|
|