Fixede744 Wed May 23 10:57:13 2018 megumiDAQGeneral Photo of the circuit
photo of the circuit area
Fixede744 Wed May 23 13:15:47 2018 megumiDAQGeneralN/ATime calibration for TDC (EXL)
Time calibrator setting
Range 5.12 us
Period 160 ns


RUN #406 : Time calibration for TDC ch 1,2,3,4,5,6,7,8
ch2 is missing...

RUN #407 : Time calibration for TDC ch 9,10,11,12,13,14,15,16

RUN #408 : Time calibration for TDC ch 17, 31, 32 (PPT, EXL17, EXL18)
but i cannot find those entry in the basic_online...


The calib parameters for EXL detector (energy+time) are:

EXL_E1 -71.1150 0.668983
EXL_E2 132.36 0.519247
EXL_E3 71.2 0.5649
EXL_E4 -58.9582 0.600488
EXL_E5 72.8547 0.579928
EXL_E6 -56.2703 0.598377
EXL_E7 91.2014 0.540216
EXL_E8 95.1007 0.488096
EXL_E9 9.26351 0.610848
EXL_E10 -2.42136 0.560869
EXL_E11 86.8976 0.503247
EXL_E12 105.457 0.464832
EXL_E13 45.8667 0.848081
EXL_E14 68.9514 0.792648
EXL_E15 2.84729 0.799
EXL_E16 18.4952 0.426236
EXL_E17 18.7380 0.485055
EXL_E18 116.032 0.492694
EXL_T1 0 1.73118
EXL_T2 0 1
EXL_T3 0 1.72242
EXL_T4 0 1.7302
EXL_T5 0 1.74106
EXL_T6 0 1.71348
EXL_T7 0 1.73504
EXL_T8 0 1.73337
EXL_T9 0 1.72332
EXL_T10 0 1.75605
EXL_T11 0 1.7177
EXL_T12 0 1.74387
EXL_T13 0 1.74781
EXL_T14 0 1.72464
EXL_T15 0 1.72852
EXL_T16 0 1.72436
EXL_T17 0 1
EXL_T18 0 1
Pinnede744 Wed May 23 15:10:15 2018 iulianOTHERGeneralN/AProcedure to start stop RUNS
Fixede744 Wed May 23 15:40:58 2018 Charles Houarner ValérieMUST2SoftwareN/ATESTS MUVI internal pulser T1-T4 strips X
To check the signals and trigger on T4 we used the internal pulser on T4,
from the SYNCHROTEST pulser at 150 Hz.
The signal was set on the channel 5 of each Mate of the MufeeX card of the T4 telescope:
MM4_STRX_E5, E21, E37, E53, E69, E85, e101, E117.
Figure testGeneInterneT4plotCh5Mate.png
The signal of the pulser can be seen around 9400 to 9850 on the several channels (see the zooms). the pedestal is large, around 8085 to 8100.
on the other channels see for instance the zoom on Strx_E118.
Pulser on channel 5 of 4 Mate of MufeeX TestMust2tel4matePulserInt.png

With the pulser only on channel 5 of Mate-1 of T4,
see the thinner pedestals on the other channels, in the plots:
TestMust2tel4PulserIntMate5.png
Checking the pedestals on the other telescopes: TestMust2telT1toT3andT5mat5onT4.png
Fixede744 Wed May 23 15:42:04 2018 Louis, ValérieMUST2GeneralN/ACALIMERO run 409 - XT - T1 to T4
Started run #409
GMT triggers: GecoCalimeroMuviGMT.png
HT on cf : HTtelescopesMustsWed23May.png
Calimero TC 640ns; period 20ns
XT for T1 to T4 ampli pulser 12MeV
thresholds for telescopes T1 to T3, 400 keV except T4: Threshold 1MeV
cf GecoCalimeroMuviTel4Thr1MeV.png
problem of configuration:
cf configCalim1.png trigger must be external on the calimero pulser interface.
cf good one on the configCalimOkexterne.png (to be done for the next runs)
Pinnede744 Wed May 23 17:23:34 2018 FreddyMUST2General Pedestals and alpha calibration analysis
Calibration coefficients for MUST2 telescopes were extracted from run_0118 (acquired during night from 13th to 14th of May). They are now located in the folder:

/home/e748/analysis/nptool/Projects/e744/Calibration/Energy/Calibration/Summary_run_0118

Based on the analysis of this run we realized that:
  • T4_StripX had pedestal normalization issue (for MATE 1,3,5,7) and alpha peaks were enlarged or doubled.
  • Pedestals used until today (23rd of May) were based on the pedestal measurement of the 28th of April !
Due to that, we remeasured the raw values of the pedestals today and compared them with the one used up to now.
The differences (in channels) between these two pedestal values for each telescope are plotted on the attached figure (X from 1-128 and Y after).
The drifts can be partially understood by the fact that the conditions evolved a lot during one month (cooling system temperature, etc).

For the online analysis, calibration of run_0118 (13/05) will be used but they somewhat lie in time between the two pedestal measurement (28/04 and 23/05).

However it is important right after the experiment to perform a new alpha calibration in conditions much closer to the measurement.
Fixede744 Wed May 23 18:20:59 2018 e744MUST2GeneralN/ATest Calimero Run 425
Started run #425 Calimero NEW XT T1toT4
ampl Pulser 12MEV; thr for T4 1 MeV
problem on data taking
Ongoinge744 Wed May 23 20:52:01 2018 Iulian ValerianRUNGeneral run #429 and #430 and config gmt
Changed VAL from 2 us to 2.5 us

run #429 exl ppt triggers

run #430 exl ppt triggers. Changed val on gmtslave also

The correlation between MUST and PPT (run430_E_PPT_vs_T_PPT.pdf) is due to the beta decay of 138La (internal contamination in the LaBr crystal). PPT detects the beta energy with 100% eff, while the gamma rays - emitted in the beta decay process- interacted in MUST detectors. The EXL bidim shows only random events (no internal contamination).
Fixede744 Wed May 23 23:37:14 2018 Valérie L.MUST2GeneralN/AMUVI configuration DAS
Configurations files of the MUVI 1 MufeeX and Y.
On MufeeX and Y configuration:
Note that the thresholds on Must2 T1 to T3 is at 400 keV on May 23th Midnight (same as before); and for T4, now it is set at 1 MeV (not 400 keV).
On Muvi/CAS configuration :
+ suppression of Energy and time pedestals, see the page in two snapshot files, ConfigMANIPMUVI2CASTel1A.png ; ConfigMANIPMUVI1CASTelB.png
(all green; in contrast with time calib configuration :red squares cf for instance : configCalimMUVI2CASTel8.png)
+ ORDi
checking temperature on the Mufee MUST2 cards:
example of good temperature on card (around 4 to 8°C when the cooling sytem is set at -4°C) : ConfigDASMuvi1Tel5mufeeXokTemp.png
Example of temperature problem on card (cooling system not running correctly, bad situation on April 25th) : Problem25AprilTemptTel4mufeeX.png

Configuration of the modules of the second Slave crate which includes MUVI2, GMT slave and Centrum slave:
Must2Crate2GMTslave.png ; MUVIcrate2ConfigCentrumSlave.png
Fixede744 Thu May 24 01:02:19 2018 ValerianOTHERGeneralN/Arun #431
run #431
Trigger LISE
Beam in D4
start @ 00h36
stop @ 1h34
Fixede744 Thu May 24 01:10:30 2018 iuliqnRUNGeneral run 433 Lise trigger
Should be ql foil in front of the si detector....
Fixede744 Thu May 24 01:11:26 2018 Iulian ValerianRUNGeneralN/Arun 434 Lise trigger
Cats inserted

efficiency is around ~99%
Fixede744 Thu May 24 01:53:28 2018 iulianRUNGeneralN/Arun 438 Lise trigger
run 438 D4 in
run 439 d6 in.

D4 D6 transmision with CATS in:

83425./106149.=7.85923560278476430e-01
Ongoinge744 Thu May 24 02:30:52 2018 iulianRUNGeneralN/ARUN 440 14N no target trigger Must & cats %100
RUN 440
14N beam \
no target
trigger t1-t5
cats %100

some counts in t5. Very low transmission . max 30 while in cats we had 500
Fixede744 Thu May 24 03:21:37 2018 iulianOTHERHardwareN/APosition measurements Must2/PPT/EXL
Fixede744 Thu May 24 03:57:34 2018 iulianRUNGeneralN/Arun 442 Lise trigger d6
Fixede744 Thu May 24 04:20:34 2018 iulianRUNGeneralN/Arun 443 T1-t5 triggers
run 443
T1-T5 triggers

still problems to recover the counting on must2. Cats: 5000 pps , T5: 50 pps max


Below changes in tuning with little change in counting...

The energy for 14N7+ at the entrance of must2 should be 28.44 meV if the beam dump thickness is correct (34 um). If a dead layer of 0.5 um of Al is included, the energy became 27.849. This looks very close to what we see on X strip, and about 1 MeV off on Y strips.
Pinnede744 Thu May 24 05:44:56 2018 iulianRUNGeneralN/AImportant::analysis of the run 443/ things to do
No stop on t5, but TAC MM_CATS ok.. So two possibilities:
1) Stop Cable not connected on Muvi2
2) Problem with the validation of CATS by FAG

HF validated by FAG was not working

Dead time scaler was not working

We need to erase all the scalers at the beginning of the run, including the part from Muvi (ORD, DESC, etc). Atm we erase only the U2M not the other part

The big problem is the transmission between LISE silicon detector D6 and T5 must with CATS on or off. 3000 counts/s on silicon d6 or CATS -> maximum 300 on T5. Is there a way to miss counting in Must2?


TAC_CATS_HF ok
TAC_MM_CATS ok
T_MM_EXLor present with prompt from cosmics?!
T_MM_HF ok
T_MM_HFv not present
Ongoinge744 Thu May 24 05:59:44 2018 iulianMUST2GeneralN/Arun 444 t1-t4 trigger no target 14n beam
run 444
t1-t4 trigger
no target
14n beam
Ongoinge744 Thu May 24 06:30:27 2018 iulianRUNGeneralN/Arun 445 t1-t4 trigger no target 14n beam no CATS