MUST2 SAMURAI_2018 S3-LEB-LPC SUPERNEMO MUGAST EXPAND SCALP GALATRON HiCARI VELO
  MUGAST, Page 1 of 132  Not logged in MUGAST
Status ExpNbr Date Author Typedown Category Target-Source Subject Text Attachments
FixedTEST Fri Mar 29 10:00:52 2019 Iulian VAMOSGeneralN/AGMT channel4 corresponds to VAMOS nowVoie4 GMT = trigger Vamos   
Fixedcom2019 Sat Apr 6 13:10:11 2019 mugastVAMOSHardwareCD2check in VAMOS HVtarget drift chamber HV checked. They are
OK
  
Fixede744s Thu Apr 11 02:36:15 2019 Daniele, AndreaVAMOSGeneralN/AVAMOS cfg[TABLE border="1"]
VAMOS BRO= 0.64050 Phi= 45 Dtrans= 0.66m
T-xFoc=7.995m 
  
Fixede744s Thu Apr 11 06:38:12 2019 DiegoVAMOSHardware TACS modification+300 ns of delay in the HF validated signal
that gives the STOP of T_FPMW_HF && T_CATS2_HF.
  
Fixede744s Fri Apr 12 19:44:09 2019 diegoVAMOSSoftware SetAlias script for VAMOS identification   SetAlias.C 
Fixede744s Fri Apr 12 20:17:52 2019 mugastVAMOSGeneral Increasing Pressure VAMOS ICWe have increased the pressure of VAMOS-IC
from 50 mbar to 55 mbar in order to stop
the beam in the pad n4 and not having few
  
Fixede744s Sat Apr 13 17:31:54 2019 mugastVAMOSHardware new Threshold on DC1 Channel 127Channel 127 of DC1 had a reduction of gain
from yesterday, I corrected the gain by calibration
and I reduced the threshold from 2114 to
  
Fixede744s Sat Apr 13 20:16:05 2019 DiegoVAMOSGeneral Vamos Efficiency***************************************RUN
118************************************************
  
Fixede744s Sat Apr 13 22:40:00 2019 DiegoVAMOSGeneral Saturation in the WIRES of Drift chamber due to Pile-UpThere is Saturation in the Energy of the WIRES
due to the Pile-up, it is not urgent to correct
it because these parameters are not needed
 DC_Wire_saturation.png 
Fixede744s Sun Apr 14 15:05:06 2019 A. LemassonVAMOSHardware Change of Offset in DC Numexo[LIST]
[*] Increasing offset to minimize saturation.
 DC_NUMEXO_AfterChange.pngDC_NUMEXO_BeforeChnage.png 
Fixede744s Sun Apr 14 15:26:48 2019 Nikola Dieter Nicolas Beyhan KseniiaVAMOSHardwareCH2New thresholds values for DC0 and DC3Thresholds are lowered from 4V to 2V for DC0
Thresholds are lowered from 6V to 4V for
DC3
  
Fixede744s Sun Apr 14 16:55:57 2019 Iulian Antoine VAMOSHardwareCH2rTarget change and Brho change VAMOS before run 125 for off resonance measurement16:30 start run 124
setting brho for next run
brho old = 0.519964
  
Fixede744s Mon Apr 15 01:57:08 2019 iulian Jaromir ValerianVAMOSHardwareN/AVamos efficiency 125_0to obtain it:
>lpcgrit
>npp mugast
 EffCheck.C 
Fixede744s Mon Apr 15 08:03:21 2019 Damien, Faïrouz, Marion, Nikola, Magda, ChloeVAMOSHardwareCH2Vamos efficiency 125_1============================================================
          offline/root_vamos/run_0125_1.root
============================================================
  
Fixede744s Mon Apr 15 08:04:57 2019 Damien, Faïrouz, Marion, Nikola, Magda, ChloeVAMOSHardwareCH2Vamos efficiency 125_2root [1] .x macros/EffCheck.C 
============================================================
          offline/root_vamos/run_0125_2.root
  
Fixede744s Mon Apr 15 10:00:01 2019 Damien, Faïrouz, Marion, Nikola, ChloeVAMOSHardwareCH2Vamos efficiency 125_3============================================================
          offline/root_vamos/run_0125_3.root
============================================================
  
Fixede744s Mon Apr 15 10:07:23 2019 AntoineVAMOSHardware Brho VAMOS
During the change, Johan entered in G1 and
connected a mass cable for the drift chambers.
 20190415_094107.jpg 
Fixede744s Mon Apr 15 12:33:52 2019 A. LemassonVAMOSHardware Test Run 127 : Change if IC ShapingTry to change IC Shaping to solve the pb of
Continuous Line in IC0 vs IC1
Change Shaping on all IC during run 126 Change
 IC_Threshold_BeforeChange_run126.pngIC_Decay_BeforeChange_run127.pngIC_CHange_Shaping__run127.pngIC_Shaping_Restore_run127.png 
Fixede744s Mon Apr 15 12:39:45 2019 Damien, Faïrouz, Nikola, ChloeVAMOSHardwareCH2Vamos efficiency 126_0============================================================
          offline/root_vamos/run_0126_0.root
============================================================
  
Fixede744s Mon Apr 15 14:14:30 2019 Damien, Faïrouz, Nikola, Iulian, and allVAMOSHardwareCH2Vamos efficiency 128_0============================================================
          offline/root_vamos/run_0128_0.root
============================================================
  

ELOG Home Page