MUST2
SAMURAI_2018
S3-LEB-LPC
SUPERNEMO
MUGAST
EXPAND
SCALP
GALATRON
HiCARI
VELO
MUGAST, Page 13 of 132
Not logged in
Find
|
Login
Full
| Summary |
Threaded
2636 Entries
Goto page
Previous
1
,
2
,
3
...
12
, 13,
14
...
130
,
131
,
132
Next
Status
ExpNbr
Date
Author
Type
Category
Target-Source
Subject
Text
Pinned
com2019
Thu Apr 4 14:45:53 2019
Valerian
OTHER
Hardware
N/A
Surveyor's measurements
Summary of the Surveyors. Joined the pdf and
the Excel file
Fixed
com2019
Sun Apr 7 14:24:18 2019
Valerian
OFFLINE
Software
CD2
Ex and E gamma with all statistic (run 256+257)
Fixed
e744s
Mon Apr 8 11:58:37 2019
Valerian
OTHER
General
N/A
Particle identification with CATS or HF
After discussing about using the HF, I join
as a reference what was obtained during experiment
e744 of last year. We can see that using
6x
Fixed
com2019
Tue Apr 9 10:44:40 2019
Valerian
MUST2
Software
CD2
CsI Calib files from the commissioning for proton
CsI calibration obtained from the proton data
of the commissioning of mugast.
Fixed
e744s
Thu Apr 11 11:36:09 2019
Valerian
OFFLINE
Software
CH2
Comparison between the two e744
Current calibration is off, a shift of -1.5MeV
was done to reproduce the previous data.
Fixed
e744s
Thu Apr 11 13:43:26 2019
Valerian
OFFLINE
Software
CH2
Target position for 14N runs
Fixed
e744s
Thu Apr 11 14:03:45 2019
Valerian
CATS
Hardware
N/A
In case of a CATS2 tripped
Currently, CATS2 is inserted, if the window
:
Fixed
e744s
Fri Apr 12 10:12:45 2019
Valerian
OFFLINE
Software
CH2
Comparison between HF and CATS for ELab ThetaLab
Using the HF show noises that is not seen
with CATS on the ToF spectra
Fixed
e744s
Fri Apr 12 10:36:09 2019
Valerian
RUN
General
N/A
Procedure to follow during runs
[SIZE=4][B][SIZE=3]At the beginning of a run
:
[/B]
Fixed
e744s
Mon Apr 15 17:05:24 2019
Valerian
OFFLINE
Software
CH2
Evolution of deE
Evolution of dEE between run 122 (8e4pps)
and 129 (2.5e5pps)
Fixed
e744s
Mon Apr 15 17:10:54 2019
Valerian
OFFLINE
Software
CH2
Evolution of deE
Evolution of dEE between run 122 (8e4pps)
and 130 (2.5e5pps)
Fixed
e744s
Tue Apr 16 11:39:40 2019
Valerian
OFFLINE
Software
CH2
two proton kinematics and center of mass reconstruction with all stat
Fixed
e744s
Thu Apr 18 15:40:57 2019
Valerian
RUN
Hardware
N/A
TAC calib runs 226-227
After multiple acq issues, TAC calib done...
Calib done with 2.56us range and 0.02us period.
Fixed
e744s
Thu Apr 18 17:45:45 2019
Valerian
OTHER
Hardware
N/A
Start heating and stopping Voltage + Acq
HV+BT are off and heating is started for Arnaud
to open the chamber
Fixed
e744s
Wed Apr 24 15:01:01 2019
Valerian
OTHER
Hardware
N/A
Electronic scheme on the MUGAST side after experiment e744
Attached are schematics of the electronics.
Fixed
e744s
Fri Apr 26 11:29:02 2019
Valerian
OTHER
Software
N/A
Notes about the electronic
While doing the electronic scheme, I saw that
the Inspection line was inducing a bad signal
in the coincidence module between fag and
Fixed
e786s
Mon Jul 1 13:27:44 2019
Valerian
OTHER
General
N/A
Time calibration didn't work
Rerunning Time Calibration
Fixed
TEST
Fri Feb 21 17:45:54 2020
VAMOS
VAMOS
General
N/A
Logbook VAMOS setup preparation e775s
Fixed
Tue Jul 23 17:09:43 2019
UK refugees
OTHER
Social
Kipper issues.
Fixed
Tue Jul 23 23:22:56 2019
UK refugees
OTHER
Social
Kipper issues.
I would mail you some but the postage is nuts
those days!
Goto page
Previous
1
,
2
,
3
...
12
, 13,
14
...
130
,
131
,
132
Next
ELOG Home Page