MUST2
SAMURAI_2018
S3-LEB-LPC
SUPERNEMO
MUGAST
EXPAND
SCALP
GALATRON
HiCARI
VELO
|
MUGAST |
Not logged in |
|
|
Message ID: 3845
Entry time: Mon Apr 8 11:58:37 2019
|
Author: |
Valerian |
ExpNbr: |
e744s |
Type: |
OTHER |
Category: |
General |
Status: |
Fixed |
Target-Source: |
N/A |
Subject: |
Particle identification with CATS or HF |
|
|
After discussing about using the HF, I join as a reference what was obtained during experiment e744 of last year. We can see that using an external TAC the time resolution is much worse using HF.
I also join as a reference the same timing using MUVI.
Edit: Added simulation with 3 different time resolution.
Joined plot are :
- TAC MUST2-CATS
- TAC MUST2-HF
- Calibrated ToF on MUVI
- Simulated : CATS (500ps resolution)
- Simulated : HF best case scenario (2ns)
- Simulated : HF as in previous experiment (4ns)
|
|
|
|
|
|
|
|
|
|
|
|
|