Pinned | com2019 |
Thu Apr 4 14:45:53 2019 |
Valerian | OTHER | Hardware | N/A | Surveyor's measurements |
Summary of the Surveyors. Joined the pdf and the Excel file |
Attachment 1: GANIL-0057_E744_I-Stefan.pdf
|
|
Attachment 2: E744_XYZ_détecteurs_Si.xlsx
|
Fixed | com2019 |
Sun Apr 7 14:24:18 2019 |
Valerian | OFFLINE | Software | CD2 | Ex and E gamma with all statistic (run 256+257) |
|
Attachment 1: bilan_run256_and_257_Ex_Egamma.png
|
|
Fixed | e744s |
Mon Apr 8 11:58:37 2019 |
Valerian | OTHER | General | N/A | Particle identification with CATS or HF |
After discussing about using the HF, I join as a reference what was obtained during experiment e744 of last year. We can see that using an external TAC the time resolution is much worse using HF.
I also join as a reference the same timing using MUVI.
Edit: Added simulation with 3 different time resolution.
Joined plot are :
- TAC MUST2-CATS
- TAC MUST2-HF
- Calibrated ToF on MUVI
- Simulated : CATS (500ps resolution)
- Simulated : HF best case scenario (2ns)
- Simulated : HF as in previous experiment (4ns)
|
Attachment 1: TMMCATS.pdf
|
|
Attachment 2: TMMHF.pdf
|
|
Attachment 3: TMMMUVI.pdf
|
|
Attachment 4: ToF_simulated_500ps.pdf
|
|
Attachment 5: ToF_simulated_2ns.pdf
|
|
Attachment 6: ToF_simulated_4ns.pdf
|
|
Fixed | com2019 |
Tue Apr 9 10:44:40 2019 |
Valerian | MUST2 | Software | CD2 | CsI Calib files from the commissioning for proton |
CsI calibration obtained from the proton data of the commissioning of mugast. |
Attachment 1: Cal_CsI_E_MM1.cal
|
MUST2_T1_CsI1_E -349.193 0.0426562
MUST2_T1_CsI2_E -365.544 0.0445866
MUST2_T1_CsI3_E -395.1 0.0481881
MUST2_T1_CsI4_E -339.257 0.0413942
MUST2_T1_CsI5_E -300.562 0.036683
MUST2_T1_CsI6_E -305.873 0.0373042
MUST2_T1_CsI7_E -306.176 0.0372682
MUST2_T1_CsI8_E -306.058 0.0372823
MUST2_T1_CsI9_E -379.8 0.046326
MUST2_T1_CsI10_E -389.184 0.0452695
MUST2_T1_CsI11_E -323.838 0.0394854
MUST2_T1_CsI12_E -345.276 0.0421109
MUST2_T1_CsI13_E -346.313 0.0419908
MUST2_T1_CsI14_E -323.431 0.0394665
MUST2_T1_CsI15_E -381.394 0.0465157
MUST2_T1_CsI16_E -366.608 0.0447318
|
Attachment 2: Cal_CsI_E_MM2.cal
|
MUST2_T2_CsI1_E -395.198 0.0482442
MUST2_T2_CsI2_E -358.257 0.0437269
MUST2_T2_CsI3_E -222.987 0.0272904
MUST2_T2_CsI4_E -320.924 0.0391246
MUST2_T2_CsI5_E -304.016 0.0371591
MUST2_T2_CsI6_E -360.763 0.044042
MUST2_T2_CsI7_E -338.862 0.0413499
MUST2_T2_CsI8_E -323.388 0.0395278
MUST2_T2_CsI9_E -297.329 0.0362987
MUST2_T2_CsI10_E -353.491 0.0431759
MUST2_T2_CsI11_E -336.682 0.0410607
MUST2_T2_CsI12_E -322.943 0.0393981
MUST2_T2_CsI13_E -352.883 0.0430912
MUST2_T2_CsI14_E -265.011 0.0323568
MUST2_T2_CsI15_E -411.526 0.0502348
MUST2_T2_CsI16_E -381.945 0.0466196
|
Attachment 3: Cal_CsI_E_MM3.cal
|
MUST2_T3_CsI1_E 0 0
MUST2_T3_CsI2_E -233.624 0.0285431
MUST2_T3_CsI3_E -269.869 0.0329581
MUST2_T3_CsI4_E -198.672 0.0244026
MUST2_T3_CsI5_E -167.381 0.020794
MUST2_T3_CsI6_E -285.043 0.0347164
MUST2_T3_CsI7_E -306.174 0.0372958
MUST2_T3_CsI8_E -289.492 0.0353261
MUST2_T3_CsI9_E -262.419 0.0320755
MUST2_T3_CsI10_E -262.419 0.0320755
MUST2_T3_CsI11_E -339.706 0.0412583
MUST2_T3_CsI12_E -276.843 0.0338448
MUST2_T3_CsI13_E -283.321 0.0345096
MUST2_T3_CsI14_E -282.583 0.0344342
MUST2_T3_CsI15_E -280.308 0.034049
MUST2_T3_CsI16_E -239.464 0.0292454
|
Attachment 4: Cal_CsI_E_MM4.cal
|
MUST2_T4_CsI1_E -274.041 0.0334448
MUST2_T4_CsI2_E -238.158 0.029079
MUST2_T4_CsI3_E -212.05 0.0259187
MUST2_T4_CsI4_E -328.425 0.040072
MUST2_T4_CsI5_E -238.067 0.0290967
MUST2_T4_CsI6_E -255.208 0.0311713
MUST2_T4_CsI7_E -274.469 0.0334524
MUST2_T4_CsI8_E -264.172 0.0322145
MUST2_T4_CsI9_E -228.564 0.0279046
MUST2_T4_CsI10_E -274.475 0.0335075
MUST2_T4_CsI11_E -313.537 0.0382149
MUST2_T4_CsI12_E -333.735 0.0405833
MUST2_T4_CsI13_E -241.099 0.0294403
MUST2_T4_CsI14_E -214.379 0.026157
MUST2_T4_CsI15_E -212.264 0.0258707
MUST2_T4_CsI16_E -250.657 0.0305457
|
Fixed | e744s |
Thu Apr 11 11:36:09 2019 |
Valerian | OFFLINE | Software | CH2 | Comparison between the two e744 |
Current calibration is off, a shift of -1.5MeV was done to reproduce the previous data. |
Attachment 1: current_exp_old_e744.png
|
|
Fixed | e744s |
Thu Apr 11 13:43:26 2019 |
Valerian | OFFLINE | Software | CH2 | Target position for 14N runs |
|
Attachment 1: XY_run14N.png
|
|
Attachment 2: Xshift_run14N.png
|
|
Attachment 3: Yshift_run14N.png
|
|
Fixed | e744s |
Thu Apr 11 14:03:45 2019 |
Valerian | CATS | Hardware | N/A | In case of a CATS2 tripped |
Currently, CATS2 is inserted, if the window :
CATS2 has tripped appear, one should do the following :
- Open a terminal
- Type: HV
- Username is : admin
- Password is : admin
- Press enter twice
The list of channels is going to appear.
- Using the arrow of the keyboard, go down until you reach cats2
- then go right until you reach Off
- press space, the dectector should start ramping up
- If it trips again, you can try to put voltage to cats1 (right above cats2)
Two possibility :
- If cats1 trip it is the gas bottle that is empty call : 07 83 34 30 81 (Sebastien)
- If cats1 doesn't trip try cats2 again, and if it trips lower the voltage of cats2
To lower the voltage of cats2 : go to the left until you reach the first cell after cats2 name and lower the voltage 10 volts and try to start cats2 again.
THEN CLOSE THE TERMINAL |
Fixed | e744s |
Fri Apr 12 10:12:45 2019 |
Valerian | OFFLINE | Software | CH2 | Comparison between HF and CATS for ELab ThetaLab |
Using the HF show noises that is not seen with CATS on the ToF spectra |
Attachment 1: ELabThetaLabrun87_E744_HFvsCATS.png
|
|
Fixed | e744s |
Fri Apr 12 10:36:09 2019 |
Valerian | RUN | General | N/A | Procedure to follow during runs |
At the beginning of a run :
- Do screenshots of the scalers and add them to the elog.(Say it is at the beginning of the run)
During a run, one should :
- Check regularly the scalers.
- Look at the different pages on vigru.
- Check if there are any problem concerning the Voltages, a window should be prompted to you if it is the case. If the window has FP written it is on the VAMOS side.
- Do conversion, see corresponding entry (Or paper next to computer)
- Check the last pending issues in the elog and if they are fixed, edit them to fix (any HV trip or over-current are pending and shoudl be switch to fix).
Every hours and before stopping the run:
- Do screenshots of the scalers and add them to the elog.(Say at which time it is done)
- Do screenshots of all the vigru pages of MUGAST and VAMOS and add them to the elog.
|
Fixed | e744s |
Mon Apr 15 17:05:24 2019 |
Valerian | OFFLINE | Software | CH2 | Evolution of deE |
Evolution of dEE between run 122 (8e4pps) and 129 (2.5e5pps) |
Attachment 1: DeEEvolutionWithIntensity.png
|
|
Fixed | e744s |
Mon Apr 15 17:10:54 2019 |
Valerian | OFFLINE | Software | CH2 | Evolution of deE |
Evolution of dEE between run 122 (8e4pps) and 130 (2.5e5pps) |
Attachment 1: DeEEvolutionWithIntensityIC1vsIC2.png
|
|
Fixed | e744s |
Tue Apr 16 11:39:40 2019 |
Valerian | OFFLINE | Software | CH2 | two proton kinematics and center of mass reconstruction with all stat |
|
Attachment 1: All_stat_2p.png
|
|
Fixed | e744s |
Thu Apr 18 15:40:57 2019 |
Valerian | RUN | Hardware | N/A | TAC calib runs 226-227 |
After multiple acq issues, TAC calib done...
Calib done with 2.56us range and 0.02us period. using cable with 5+16ns lenght
run 226:
TAC1 Vamos AGATA
TAC2 Fag-HF
TAC4 VAMOS CATS1
TAC5 MUST2 VAMOS (!!! Warning Parameter is wrong, it is called Si AGATA)
TAC6 MUST2 AGATA (!!! Warning Parameter is wrong, it is called Si VAMOS) -> Explains the prompt in AGATA...
TAC7 MUST2 CATS1
TAC8 CATS2 CATS1
TAC9 AGATA HF
run 227
TAC3 CATS1 HF |
Fixed | e744s |
Thu Apr 18 17:45:45 2019 |
Valerian | OTHER | Hardware | N/A | Start heating and stopping Voltage + Acq |
HV+BT are off and heating is started for Arnaud to open the chamber |
Fixed | e744s |
Wed Apr 24 15:01:01 2019 |
Valerian | OTHER | Hardware | N/A | Electronic scheme on the MUGAST side after experiment e744 |
Attached are schematics of the electronics. |
Attachment 1: MUGAST_Electronic_scheme_afterE744.pdf
|
|
Fixed | e744s |
Fri Apr 26 11:29:02 2019 |
Valerian | OTHER | Software | N/A | Notes about the electronic |
While doing the electronic scheme, I saw that the Inspection line was inducing a bad signal in the coincidence module between fag and CATS1. See joined image.
Also, I broke a cable between CATS1 Fifo and the delay box, the delay is now 2 ns longer. |
Attachment 1: Signal_oscilloscope_coinc_module.jpeg
|
|
Fixed | e786s |
Mon Jul 1 13:27:44 2019 |
Valerian | OTHER | General | N/A | Time calibration didn't work |
Rerunning Time Calibration |
Fixed | TEST |
Fri Feb 21 17:45:54 2020 |
VAMOS | VAMOS | General | N/A | Logbook VAMOS setup preparation e775s |
|
Attachment 1: LogBook_e775s-comprimido.pdf
|
|
Fixed | |
Tue Jul 23 17:09:43 2019 |
UK refugees | OTHER | Social | | Kipper issues. |
|
Attachment 1: 3948.jpg
|
|
Fixed | |
Tue Jul 23 23:22:56 2019 |
UK refugees | OTHER | Social | | Kipper issues. |
I would mail you some but the postage is nuts those days! |