Status |
ExpNbr |
Date |
Author |
Type |
Category |
Target-Source |
Subject |
Pinned | com2019 |
Thu Apr 4 14:45:53 2019 |
Valerian | OTHER | Hardware | N/A | Surveyor's measurements |
Summary of the Surveyors. Joined the pdf and the Excel file |
Fixed | com2019 |
Sun Apr 7 14:24:18 2019 |
Valerian | OFFLINE | Software | CD2 | Ex and E gamma with all statistic (run 256+257) |
|
Fixed | e744s |
Mon Apr 8 11:58:37 2019 |
Valerian | OTHER | General | N/A | Particle identification with CATS or HF |
After discussing about using the HF, I join as a reference what was obtained during experiment e744 of last year. We can see that using an external TAC the time resolution is much worse using HF.
I also join as a reference the same timing using MUVI.
Edit: Added simulation with 3 different time resolution.
Joined plot are :
- TAC MUST2-CATS
- TAC MUST2-HF
- Calibrated ToF on MUVI
- Simulated : CATS (500ps resolution)
- Simulated : HF best case scenario (2ns)
- Simulated : HF as in previous experiment (4ns)
|
Fixed | com2019 |
Tue Apr 9 10:44:40 2019 |
Valerian | MUST2 | Software | CD2 | CsI Calib files from the commissioning for proton |
CsI calibration obtained from the proton data of the commissioning of mugast. |
Fixed | e744s |
Thu Apr 11 11:36:09 2019 |
Valerian | OFFLINE | Software | CH2 | Comparison between the two e744 |
Current calibration is off, a shift of -1.5MeV was done to reproduce the previous data. |
Fixed | e744s |
Thu Apr 11 13:43:26 2019 |
Valerian | OFFLINE | Software | CH2 | Target position for 14N runs |
|
Fixed | e744s |
Thu Apr 11 14:03:45 2019 |
Valerian | CATS | Hardware | N/A | In case of a CATS2 tripped |
Currently, CATS2 is inserted, if the window :
CATS2 has tripped appear, one should do the following :
- Open a terminal
- Type: HV
- Username is : admin
- Password is : admin
- Press enter twice
The list of channels is going to appear.
- Using the arrow of the keyboard, go down until you reach cats2
- then go right until you reach Off
- press space, the dectector should start ramping up
- If it trips again, you can try to put voltage to cats1 (right above cats2)
Two possibility :
- If cats1 trip it is the gas bottle that is empty call : 07 83 34 30 81 (Sebastien)
- If cats1 doesn't trip try cats2 again, and if it trips lower the voltage of cats2
To lower the voltage of cats2 : go to the left until you reach the first cell after cats2 name and lower the voltage 10 volts and try to start cats2 again.
THEN CLOSE THE TERMINAL |
Fixed | e744s |
Fri Apr 12 10:12:45 2019 |
Valerian | OFFLINE | Software | CH2 | Comparison between HF and CATS for ELab ThetaLab |
Using the HF show noises that is not seen with CATS on the ToF spectra |
Fixed | e744s |
Fri Apr 12 10:36:09 2019 |
Valerian | RUN | General | N/A | Procedure to follow during runs |
At the beginning of a run :
- Do screenshots of the scalers and add them to the elog.(Say it is at the beginning of the run)
During a run, one should :
- Check regularly the scalers.
- Look at the different pages on vigru.
- Check if there are any problem concerning the Voltages, a window should be prompted to you if it is the case. If the window has FP written it is on the VAMOS side.
- Do conversion, see corresponding entry (Or paper next to computer)
- Check the last pending issues in the elog and if they are fixed, edit them to fix (any HV trip or over-current are pending and shoudl be switch to fix).
Every hours and before stopping the run:
- Do screenshots of the scalers and add them to the elog.(Say at which time it is done)
- Do screenshots of all the vigru pages of MUGAST and VAMOS and add them to the elog.
|
Fixed | e744s |
Mon Apr 15 17:05:24 2019 |
Valerian | OFFLINE | Software | CH2 | Evolution of deE |
Evolution of dEE between run 122 (8e4pps) and 129 (2.5e5pps) |
Fixed | e744s |
Mon Apr 15 17:10:54 2019 |
Valerian | OFFLINE | Software | CH2 | Evolution of deE |
Evolution of dEE between run 122 (8e4pps) and 130 (2.5e5pps) |
Fixed | e744s |
Tue Apr 16 11:39:40 2019 |
Valerian | OFFLINE | Software | CH2 | two proton kinematics and center of mass reconstruction with all stat |
|
Fixed | e744s |
Thu Apr 18 15:40:57 2019 |
Valerian | RUN | Hardware | N/A | TAC calib runs 226-227 |
After multiple acq issues, TAC calib done...
Calib done with 2.56us range and 0.02us period. using cable with 5+16ns lenght
run 226:
TAC1 Vamos AGATA
TAC2 Fag-HF
TAC4 VAMOS CATS1
TAC5 MUST2 VAMOS (!!! Warning Parameter is wrong, it is called Si AGATA)
TAC6 MUST2 AGATA (!!! Warning Parameter is wrong, it is called Si VAMOS) -> Explains the prompt in AGATA...
TAC7 MUST2 CATS1
TAC8 CATS2 CATS1
TAC9 AGATA HF
run 227
TAC3 CATS1 HF |
Fixed | e744s |
Thu Apr 18 17:45:45 2019 |
Valerian | OTHER | Hardware | N/A | Start heating and stopping Voltage + Acq |
HV+BT are off and heating is started for Arnaud to open the chamber |
Fixed | e744s |
Wed Apr 24 15:01:01 2019 |
Valerian | OTHER | Hardware | N/A | Electronic scheme on the MUGAST side after experiment e744 |
Attached are schematics of the electronics. |
Fixed | e744s |
Fri Apr 26 11:29:02 2019 |
Valerian | OTHER | Software | N/A | Notes about the electronic |
While doing the electronic scheme, I saw that the Inspection line was inducing a bad signal in the coincidence module between fag and CATS1. See joined image.
Also, I broke a cable between CATS1 Fifo and the delay box, the delay is now 2 ns longer. |
Fixed | e786s |
Mon Jul 1 13:27:44 2019 |
Valerian | OTHER | General | N/A | Time calibration didn't work |
Rerunning Time Calibration |
Fixed | TEST |
Fri Feb 21 17:45:54 2020 |
VAMOS | VAMOS | General | N/A | Logbook VAMOS setup preparation e775s |
|
Fixed | |
Tue Jul 23 17:09:43 2019 |
UK refugees | OTHER | Social | | Kipper issues. |
|
Fixed | |
Tue Jul 23 23:22:56 2019 |
UK refugees | OTHER | Social | | Kipper issues. |
I would mail you some but the postage is nuts those days! |