MUST2 SAMURAI_2018 S3-LEB-LPC SUPERNEMO MUGAST EXPAND SCALP GALATRON HiCARI VELO
  MUST2, Page 5 of 48  Not logged in MUST2
Status ExpNbr Date Author Type Category Target-Source Subject Text Attachments
Fixede748 Thu Jun 29 23:26:10 2017 Valérie LapouxRUNGeneralEmptyALL CALIMERO Time Calibration MUVI129 JUNE 2017 
CONDITIONS FOR CALIMERO CALIBRATIONS
Time calibrator Period 20ns ; range 512 ns
 CalimeroRunControl.pngConfigCalimeroStat.pngCalibTmuvi1Yperiod20nsrange600ns.pngTimeMust2X_MUVI1_uncalib.pngTimeMust2Y_MUVI1_uncalib.png 
Fixede748 Fri Jun 30 00:33:36 2017 Valérie LapouxRUNGeneralEmptyALL CALIMERO Time Calibration MUVI230 JUNE 2017
CONDITIONS FOR CALIMERO CALIBRATIONS
Time calibrator Period 20ns ; range 512 ns
 CalibTimeMUVI2stripXT.pngSpectresMUVI2stripXT300ns.png 
Fixede748 Fri Jun 30 01:01:08 2017 Valérie LapouxRUNGeneralEmptyALL CALIMERO Time Calibration MUVI2 GOOD RUNS 600ns[B]RANGE TAC MUST2 600ns
CALIMERO TIME CALIBRATOR PERIOD 20ns; Range
512ns[/B]
 TimeMust2X_MUVI2_uncalib.pngTimeMust2Y_MUVI2_uncalib.png 
Fixede748 Fri Jun 30 02:00:44 2017 e748MUST2HardwareN/AWarming up of detector startedAll LV and HT off, vaccumm at 1.3e-5 mbar,
starting warm up sequence.
  
Fixede748 Fri Jun 30 11:09:59 2017 FreddyOFFLINEGeneral Analysis of DSSD Energy Calibration - alpha sourceWe made a calibration with the last alpha
source runs:
-run 19 for T1-2-3-4
 run19_Summary_EX.pdfrun19_Summary_EY.pdf 
Fixede748 Fri Jun 30 12:24:17 2017 Valérie LapouxDAQGeneral DAQ Parameters: TAC, Caviar, LISE D4, D6, Caviar   DASParamVXIMust2CatsTACLise.pngDASParamVXIChioQDC.pngDASParamVXIChioADClisepar.png 
Fixede748 Fri Jun 30 16:49:49 2017 Valérie LapouxDAQGeneral GMT triggers and chronographConfigurations for the GMT inputs.
30 June 2017 pm
all Must2 telescopes,
 DASConfigTriggerGMT.pngChronogrammeGMT30juinFAG100nsCT5µs.png 
Fixede748 Fri Jun 30 16:55:04 2017 Valérie LapouxDAQGeneral Run control for global DAQ with NUMEXOThe run start/stop sequence for the global
DAQ including the NUMEXO:
 RunControlAll748ModeMonitoring.pngNarvalRunControlAllE748.png 
Fixede748 Fri Jun 30 17:53:35 2017 Valérie LapouxDAQGeneral Scalers parameters U2M   Actionse748ganlx11withU2M.pngScalerAnalyzerU2M.png 
Fixede748 Fri Jun 30 20:46:16 2017 Valérie LapouxTARGETGeneral TARGET configurationList of the reaction target in the chamber
from bottom to up:
  
Fixede748 Sat Jul 1 09:27:46 2017 Adrien MattaOTHERGeneralN/ASHIFT TABLE    
Fixede748 Sat Jul 1 10:47:18 2017 Adrien MattaBEAMGeneralN/APrimary beam energy measurementPCP delivered the primary beam energy measurement  IMG_1984.JPG 
Fixed  Sat Jul 1 12:45:25 2017 Anastasia CATSGeneral CATS Calibratedrun_0026 CATS 1 X Y
run_0027 CATS 2 X Y
 cats_calibrated.png 
Fixede748 Sat Jul 1 14:32:02 2017 Valérie LapouxDAQGeneral Scalers U2M, parametersU2M configuration +Actions ganlx11

The signals for the scalers are converted
 ScalersU2Mok.pngCompilActionsganlx11ScalerGr1to4..png 
Fixede748 Sat Jul 1 14:45:17 2017 Valérie LapouxDAQGeneral Parameters for correlation checkingsThe [B]parameters[/B] to be used for the checking
of the correlations between crates/VME/VXI
and good running of the merging
  
Fixede748 Sat Jul 1 15:12:01 2017 Valérie LapouxONLINEHardware Conditions for Bidiv and TAC 1st July 15pm(Update the file CONDTIONS748.txt during the
experiment)
  
Fixed  Sat Jul 1 17:09:04 2017 e748MUST2General TIME CAL CHECKrun_0040_CalMust2Histos.root  must2_time_cal_run40.png 
Fixede748 Sat Jul 1 22:16:46 2017 e748DAQGeneralN/AProblem of MergeThe DAQ was not merging properly.
We figured out that the centrum was goiging
out of sync when the run was stopped.
  
Fixede748 Sun Jul 2 03:46:11 2017 e748OTHERHardware UPDATE OF TAC settingsHere are several changes made during the night
to optimize timing for TACs:
  
Fixede748 Sun Jul 2 04:58:36 2017 e748RUNGeneralN/ARun 74: MASK INStarting Run 74 with trigger plastic and MASK
at target position.
  

ELOG Home Page