Status |
ExpNbr |
Date |
Author |
Type |
Category |
Target-Source |
Subject |
Text |
 |
Fixed | e738 |
Sat Jul 14 01:24:51 2018 |
e748 | RUN | General | Cryo-LH2 | run 378 | count rate in Cats : 100 kHz
Start time: 00:42 |
  |
Fixed | e738 |
Sat Jul 14 02:46:34 2018 |
e748 | RUN | General | Cryo-LH2 | run 379 | count rate in Cats : 100 kHz
Start time: 02:41 |
 |
Fixed | e738 |
Sat Jul 14 05:00:37 2018 |
e748 | RUN | General | Cryo-LH2 | run 380 | count rate in Cats : 100 kHz
Start time: 04:38 |
 |
Fixed | e738 |
Sat Jul 14 06:49:03 2018 |
e748 | RUN | General | Cryo-LH2 | run 380 | count rate in Cats : 100 kHz
Start time: 06:39 |
    |
Fixed | e738 |
Sat Jul 14 09:57:36 2018 |
takeshi | TARGET | Hardware | Cryo-LH2 | target temperature during night | I would share the temperature log of the target
as it was liquefied 21:00 13th. |
|
Fixed | e738 |
Sat Jul 14 10:14:00 2018 |
marlčne, jacques, daisuke | RUN | General | Cryo-LH2 | RUN 382 | 12C + liquid H. Before the run, the beam stopped
for 2 hours due to the gate valve of E9 shut
out the beam. This is because the manually |
9x |
Fixed | e738 |
Sat Jul 14 11:37:58 2018 |
marlčne, daisuke | RUN | General | Cryo-LH2 | RUN 383 | 12C + liquid H.
11h33 start.
12h00 Asked PCP to increase the intensity. |
25x |
Fixed | e738 |
Sat Jul 14 14:01:55 2018 |
Daisuke, Jacques, Shumpei, Valérie | RUN | General | Cryo-LH2 | RUNS 384-385 | 12C + liquid H.
RUN 384 start 13h58 stop 15h54
|
16x |
Fixed | e738 |
Sat Jul 14 18:18:33 2018 |
Daisuke, Jean-Charles, Megumi, Nori, Shumpei, Valérie | RUN | General | Cryo-LH2 | RUN 386 TUNING 9C | 9C + liquid H.
SLITS FH31 +/- 2mm then +/-5 mm at the beginning
of the run
|
8x |
Fixed | e738 |
Sat Jul 14 18:36:38 2018 |
Daisuke, Jean-Charles, Megumi, Nori, Shumpei, Valérie | RUN | General | Cryo-LH2 | RUN 387 TUNING 9C | 9C + liquid H.
SLITS FH31 +/- 5 mm F43 opened
I ~ 1.6ľA TRIGGERS CATS2, PLASTIC div
|
|
Fixed | e738 |
Sat Jul 14 18:37:29 2018 |
Daisuke, Jean-Charles, Megumi, Nori, Shumpei, Valérie | RUN | General | Cryo-LH2 | RUN 388 TUNING 9C | 9C + liquid H.
SLITS FH31 +/- 5 mm F43 opened
I ~ 1.6ľA normal TRIGGERS MUST2 CATS div |
  |
Fixed | e738 |
Sat Jul 14 18:54:01 2018 |
Daisuke, Jean-Charles, Megumi, Nori, Shumpei, Valérie | RUN | General | Cryo-LH2 | RUN 389 TUNING 9C | 9C + liquid H.
SLITS FH31 +/- 30 mm F43 opened
I ~ 1.6ľA normal TRIGGERS MUST2 CATS div |
7x |
Fixed | e738 |
Sat Jul 14 19:01:22 2018 |
Daisuke, Jean-Charles, Megumi, Nori, Shumpei, Valérie | RUN | General | Cryo-LH2 | RUN 390 TUNING 9C | 9C + liquid H.
SLITS FH31 +/- 20 mm F43 V 10 mm; FH43 10
mm I~1.9 ľA
|
7x |
Fixed | e738 |
Sat Jul 14 19:38:25 2018 |
Daisuke, Jean-Charles, Shumpei, Valérie | RUN | General | Cryo-LH2 | RUN 391 TUNING 9C | 9C + liquid H.
SLITS FH31 +/- 20 mm F43 V 10 mm; FH43 10
mm I~1.9 ľA
|
 |
Fixed | e738 |
Sat Jul 14 20:16:50 2018 |
Daisuke, Shumpei, Valérie | RUN | General | Cryo-LH2 | RUN 392 9C | 9C + liquid H.
RUN 392 start 19h46 stop 21h47
e748 Exxx 3,5G 14 juil. 21:49 /data/e748X/e755/acquisition/run/run_0392.dat.14-07-18_19h45m58s
|
21x |
Fixed | e738 |
Sat Jul 14 21:53:48 2018 |
Daisuke, Shumpei, Valérie | RUN | General | Cryo-LH2 | RUN 393 9C | 9C + liquid H.
RUN 393 start 21h48 stop 23h49
e748 Exxx 4,0G 14 juil. 23:49 /data/e748X/e755/acquisition/run/run_0393.dat.14-07-18_21h48m17s
|
9x |
Fixed | e738 |
Sun Jul 15 00:48:03 2018 |
takeshi | RUN | General | N/A | run summary | Here are the run summary of E738 experiment
up to 1:00 am 15th.
31.7 hours for 10C + H2
|
|
Fixed | e738 |
Sun Jul 15 00:49:52 2018 |
Megumi, Shumpei, Takeshi, Benoît, Valérie | RUN | General | Cryo-empty | RUN 394 9C | 9C + Empty target 15th JULY
RUN 394 start 0h43 stop 03h20
e748 Exxx 2,9G 15 juil. 2018 /data/e748X/e755/acquisition/run/run_0394.dat.15-07-18_00h43m25s
|
    |
Fixed | e738 |
Sun Jul 15 01:26:49 2018 |
takeshi | TARGET | Hardware | Cryo-LH2 | temperature log of the target | Here are the temperature log of the target
before it was evaporated. |
 |
Fixed | e738 |
Sun Jul 15 01:35:09 2018 |
takeshi, Valérie | ONLINE | General | N/A | problem of the beam image on vigru | The beam image at the target is not clear
on online monitor.
We have confirmed that the target is correctly |
    |