MUST2 SAMURAI_2018 S3-LEB-LPC SUPERNEMO MUGAST EXPAND SCALP GALATRON HiCARI VELO
  MUST2, Page 1 of 48  Not logged in MUST2
New entries since:Thu Jan 1 01:00:00 1970
Status ExpNbr Date Author Type Category Target-Source Subject Text Attachments
Pinnede748 Thu Mar 23 11:19:13 2017 Adrien Matta   ScheduleThis message will contain the update schedule
of the preparation of e748.
  
PinnedGeneral Fri Mar 24 09:32:11 2017 Adrien MattaMUST2Software Usefull document for MUST2 operationsDAS Configuration:
http://wiki.ganil.fr/gap/wiki/Documentation/Software/DAS
 NOTICE_UTILISATION_MUVI_HARD_et_SOFT_(ver_081013).pdfMUVI_card_USER_MANUAL_(ver_081013).pdf 
Fixede748 Wed May 24 09:07:59 2017 Adrien MattaOTHERGeneral e748 PlanningFeel free to edit this spread sheet.

  
Pinnede748 Wed May 24 09:19:57 2017 Adrien MattaOTHERSocial e748 CollaboratorsList of Collaborators (Please edit if anyone
is missing):
  
Fixede748 Wed May 24 09:32:41 2017 Adrien MattaMUST2Hardware Mounting of the telescope in G3The telescope has been mounted in there stand
in G3. 
  
Fixede748 Wed May 24 09:35:00 2017 Adrien MattaCATSHardware BTD chambers mounting in D6Sebastient started mounting the BTD chamber
in D6. 
The frame is in place, BTD chambers one and
  
Fixede748 Wed May 24 15:48:24 2017 Adrien MattaMUST2Hardware PCB number for each telescope[LIST]
[*] T1 PCB 5
[*] T2 PCB 9
  
Fixede748 Thu Jun 1 09:29:50 2017 Adrien MattaMUST2Hardware Telescope cabling debbug in G3Test performed without vaccum, in the dark,
cooling at 20.
  
Fixede748 Thu Jun 1 09:32:38 2017 Adrien MattaMUST2Hardware MUST2 cabling schemeThe MUST2 cabling scheme has been change so
Telescope 1 to 4 and 5 to 8 are on two independent
set of distribution box and HV Card.
  
Fixede748 Fri Jun 2 12:03:32 2017 Adrien, Laurent, ShumpeiMUST2Hardware M2C vacuum testWe mounted 2 dry pump on the chamber and started
pumping at 11h.
Pressure was about 6e-1 mbar around 11h45.
  
Fixede748 Tue Jun 6 09:07:34 2017 Adrien MattaBEAMGeneral Moving to D6M2C Chamber now in D6 after a smooth ride,
ready to be aligned.
  
Ongoinge748 Tue Jun 6 17:57:07 2017 Valérian et FrançoisEXLHardware Hardware coupling of EXL with MUST2
EXL seems to fit in Adrien's setup. We still
have to check if it fits in the chamber.
 EXL_MUST2_top.png 
Fixede748 Tue Jun 6 18:17:03 2017 Valérian et FrançoisEXLHardware Hardware coupling of EXL with MUST2EXL seems to fit with Adrien's setup. 
We still have to test if it fits inside the
chamber.
 EXL_MUST2_top.jpgEXL_MUST2_side.jpg 
Fixede748 Wed Jun 7 11:29:55 2017 AdrienMECHHardwareN/ASurveyor mesurementThe surveyor are carrying out the measurement
of the detectors in D6.
The measurement should take the day, starting
  
Fixede748 Wed Jun 7 18:03:02 2017 FranckOTHERHardware LPC electronicsCaen N568B: 509, 490
Ortec TAC: 1102, 1479, 1480, 1481
Lecroy GDG222: E2557, 01175C, 831
  
Fixede748 Thu Jun 8 18:57:14 2017 Valérie LapouxMUST2Hardware Currents and Voltages on MUST2 Thursday 8th June. 
Vacuum in the chamber 9e-05 mbar; MUST2 temperature
at -5°C.
  
Fixede748 Fri Jun 9 12:30:49 2017 AdrienVACUUMHardware Vacuum LeaksWe reach a stable 1e-5 mbar. We performed
a leak check and identify that the Ionisation
chamber gate valve is not totally tight,
  
Fixede748 Fri Jun 9 12:33:25 2017 AdrienMECHGeneral MUST2 positionAfter a the surveyor came we figured out the
MUST2 telescope are 1cm too high with respect
to the beam line.
  
Fixede748 Fri Jun 9 12:34:18 2017 AdrienDAQHardware HubWe are currentlky waiting for the hub to be
configured so we can start the MUST2 DAQ.
Should be done in the afternoon.
  
Fixede748 Fri Jun 9 12:35:46 2017 AdrienMUST2Hardware CsI trip on T6The detector were left on during the night.
T6 CsI trip and cannot be switch on again.
Once we established that all the MUFFEE works
  

ELOG Home Page