MUST2 SAMURAI_2018 S3-LEB-LPC SUPERNEMO MUGAST EXPAND SCALP GALATRON HiCARI VELO
  MUST2, Page 46 of 48  Not logged in MUST2
New entries since:Thu Jan 1 01:00:00 1970
Fixed, e738, Fri Jul 13 09:03:11 2018, takeshi, RUN, General, Cryo-LH2, run summary 9C + H2 
Here is the run summary of the setting 9C beam + liquid H2 target.
Up to now, we have obtained 78 hours data, including missing strips in CATS , MUST2*BEAM trigger test, and half-filled target.
We will go to 9C + empty setting from 9:10.

See spreadsheet for the detail.
https://docs.google.com/spreadsheets/d/1yErcQcrXPdJjEOfUd9D9KPWWkWQpw5kX4wFze6vwij4/edit#gid=805236919
Fixed, e738, Fri Jul 13 09:35:26 2018, Olivier, Serge, Jacques, J-C, thomas, shumpei, daisuke, RUN, General, Cryo-empty, RUN 370 visu_2018-07-13_09h36m18s.pngscaler_2018-07-13_09h36m16s.png
Empty target + 9C.
9h29 The beam is back. start 9h28 stop 11h21
e748 Exxx 2,1G 13 juil. 11:21 /data/e748X/e755/acquisition/run/run_0370.dat.13-07-18_09h28m21s
Fixed, e738, Fri Jul 13 13:41:48 2018, Daisuke, Jacques, Megumi, Olivier, Otsu, Takeshi, Valérie, RUN, General, Cryo-empty, RUNS 371-372 32x
Empty target + 9C.
Run 371 start 11h20 stop 13h20
e748 Exxx 2,1G 13 juil. 13:20 /data/e748X/e755/acquisition/run/run_0371.dat.13-07-18_11h20m03s
Run 371 start 13h20 stop

I primary beam ~ 1.8 µA large fluctuations down to 0.6 µA
CATS1 ~ 180kpps CATS2 ~ 164 kpps Plastic ~ 154 kpps
CATS1 HV 670V I~0.12 µA ; CATS2 HV 650V 0.10 µA
Fixed, e738, Fri Jul 13 16:41:49 2018, Antoine, Maurycy, OFFLINE, Social, Cryo-LH2, Multiparticles from (p,t) up to 5 Light Charged Particles in Must ! 15x
Fixed, e738, Fri Jul 13 18:07:04 2018, J-C, cristelle, nori, olivier, daisuke, RUN, General, Cryo-empty, RUN 373 scaler_2018-07-13_17h43m06s.pngvisu_2018-07-13_17h43m05s.png
12C 5+ beam. CATS2 trigger.
17h29 start
17h41 stop
Fixed, e738, Fri Jul 13 18:08:31 2018, J-C, cristelle, nori, olivier, daisuke, RUN, General, Cryo-empty, RUN 374 6x
12C5+ beam. Trigger T1-8 + CATS1%30000 + CATS2%30000 + Plastic%10000.
Target empty (under cooling).
beam intensity 350 enA
Fente 31 +/-5 mm
Fente 43 +/-10 mm (both H and V)
Beam energy 55.02 MeV/u
Fixed, e738, Fri Jul 13 21:15:53 2018, J-C, nori, shumpei, takeshi, hide, didier, serge, daisuke, RUN, General, Cryo-empty, RUN 375: 12C pilot run 8x
12C beam + empty target after measurement of 9C momentum distribution.
trigger t1-8 + cats 1 2 %30000 + plastic %10000
start 20h47 / stop 21h08
During this run, wien filter was tuned to center the beam vertically. Final setting is 2.5 kV for negative and 2.5 kV for positive.
The run started with a primary beam intensity of 350 enA. We found that CAVIAR is counting too much and leakage current of CATS1 (0.18 micro A) and 2 (0.14 micro A) are higher than in the 9C measurement. We reduced the beam intensity to 220 enA. The leakage current of CATS1 and 2 are 0.10 and 0.08 micro A, respectively. The plastic rate is about 80 kpps.
Fixed, e738, Fri Jul 13 22:00:59 2018, didier, nori, takeshi, shumpei, hide, daisuke, RUN, General, Cryo-LH2, RUN 376: 12C first run 22x
12C + liquid H.
start 21h44
stop 22h43
Fixed, e738, Fri Jul 13 23:10:55 2018, e748, RUN, General, Cryo-LH2, run 377 13x
count rate in Cats : 100 kHz
Start time: 22:44
Stop: 00:42
Fixed, e738, Fri Jul 13 23:22:26 2018, Shumpei, OFFLINE, General, Cryo-LH2, 12C beam analysis 12c.pdf
Used data run0376 (about 1 hour)

Only target position and recoil pid (deuteron or triton) is gated.
(top left) kinematics for 12C(p,d)11C
(top right) excitation energy of 11C
(bottom left) kinematics for 12C(p,t)10C
(bottom right) excitation energy of 10C

~ 500 counts/ 1 hour 12C(p,t)10C (g.s. + 2+) for T1-T6 total
Fixed, e738, Sat Jul 14 00:32:55 2018, Shumpei, OFFLINE, General, Cryo-empty, empty target analysis for 9C beam setting pd.pdfpd_60deg.pdfpt.pdfpt_60deg.pdf
H2 filled: run0312-0355
empty: run0370-0372

Scale factor for empty run is 10.0

Gate for target position and recoil pid (deuteron or triton)
Gate for theta_cm < 60 deg.

For (p,t) reaction, proton elastic scattering of beam triton contamination cannot be subtracted.
See entry 864
https://elog.lpc-caen.in2p3.fr/MUST2/864
Fixed, e738, Sat Jul 14 01:24:51 2018, e748, RUN, General, Cryo-LH2, run 378 scaler_2018-07-14_00h46m48s.pngvisu_2018-07-14_00h48m31s.pngvisu_2018-07-14_00h52m28s.png
count rate in Cats : 100 kHz
Start time: 00:42
Fixed, e738, Sat Jul 14 02:46:34 2018, e748, RUN, General, Cryo-LH2, run 379 scaler_2018-07-14_02h44m19s.pngvisu_2018-07-14_02h45m36s.png
count rate in Cats : 100 kHz
Start time: 02:41
Fixed, e738, Sat Jul 14 05:00:37 2018, e748, RUN, General, Cryo-LH2, run 380 scaler_2018-07-14_04h41m20s.pngvisu_2018-07-14_04h49m58s.png
count rate in Cats : 100 kHz
Start time: 04:38
Fixed, e738, Sat Jul 14 06:49:03 2018, e748, RUN, General, Cryo-LH2, run 380 scaler_2018-07-14_06h43m26s.pngscreenshot_2018-07-14_06h42m28s.pngvisu_2018-07-14_06h44m35s.pngvisu_2018-07-14_06h48m04s.pngvisu_2018-07-14_06h50m58s.png
count rate in Cats : 100 kHz
Start time: 06:39
Fixed, e738, Sat Jul 14 09:57:36 2018, takeshi, TARGET, Hardware, Cryo-LH2, target temperature during night liquiefy1307.png
I would share the temperature log of the target as it was liquefied 21:00 13th.
Fixed, e738, Sat Jul 14 10:14:00 2018, marlčne, jacques, daisuke, RUN, General, Cryo-LH2, RUN 382 9x
12C + liquid H. Before the run, the beam stopped for 2 hours due to the gate valve of E9 shut out the beam. This is because the manually operate turbo pump was turned off by itself due to unknown reason. Sébastien came to close the valve of this turbo pump and evacuate E9 using another turbo pump only. The vacuum of E9 is about 4e-5 mbar as of 9 am.The interlock is set at 9e-5 mbar.

09h27 start
10h30 increased primary beam intensity slightly. Before 80 kpps on plastic, after 95 kpps. Leakage current of CATs 0.10/0.08 micro A to 0.12/0.10 micro A.
11h35 stop.
Fixed, e738, Sat Jul 14 11:37:58 2018, marlčne, daisuke, RUN, General, Cryo-LH2, RUN 383 25x
12C + liquid H.
11h33 start.
12h00 Asked PCP to increase the intensity. CATS1,2 120 kpps. Plastic 100 kpps. CATS1/2 0.14/0.10 micro A. CATS2 current bursts to ~0.5 micro A once every 30 sec.
12h10 Asked PCP to decrease the intensity. CATS1,2 110 kpps. Plastic 90 kpps. CATS1/2 0.12/0.10 micro A. CATS2 current bursts to ~0.4 micro A once every 30 sec.
12h45 Asked PCP to increase the intensity. CATS1,2 110 kpps. Plastic 90 kpps. CATS1/2 0.12/0.10 micro A.
14h00 stop.
Fixed, e738, Sat Jul 14 14:01:55 2018, Daisuke, Jacques, Shumpei, Valérie, RUN, General, Cryo-LH2, RUNS 384-385 16x
12C + liquid H.

RUN 384 start 13h58 stop 15h54
CATS1/2 110 kHz, 0.12/0.10 micro A Plastic 90 kHz.
e748 Exxx 2,1G 14 juil. 15:54 /data/e748X/e755/acquisition/run/run_0384.dat.14-07-18_13h58m20s

RUN 385 start 15h54 stop 18h05
e748 Exxx 2,5G 14 juil. 2018 /data/e748X/e755/acquisition/run/run_0385.dat.14-07-18_15h53m48s
Fixed, e738, Sat Jul 14 18:18:33 2018, Daisuke, Jean-Charles, Megumi, Nori, Shumpei, Valérie, RUN, General, Cryo-LH2, RUN 386 TUNING 9C 8x
9C + liquid H.
SLITS FH31 +/- 2mm then +/-5 mm at the beginning of the run
RUN 386 start 18h16 stop 18h28
e748 Exxx 1,3G 14 juil. 2018 /data/e748X/e755/acquisition/run/run_0386.dat.14-07-18_18h15m43s

ELOG Home Page