Fixed, e748, Sat Jun 24 21:41:30 2017, e748, MUST2, General, , Pedestal alignement and calibration 
MUSt2 pedestal aligned for all telescope.

Started alpha run with all telescope in trigger as well as EXL.

Sili1 T5 and Sili2 T8 tripped.

EXL back on (LV and HV on)
Fixed, e748, Mon Jun 26 17:38:32 2017, e748, MUST2, General, N/A, CALIMERO 
Luc and Greg fixed Calimero, We have to perform the calibration but there is some work going on with CATS.
Fixed, e748, Wed Jun 28 10:52:15 2017, Valérie Lapoux, MUST2, General, , Memo for CALIMERO MUST2 Time Calibration ConfigDAQDasCalimerov2017vlxTMP.pdf
Temporary file indicating the main steps for the time calibration of MUST2 using the Calimero DAQ package program.
Fixed, e748, Fri Jun 30 02:00:44 2017, e748, MUST2, Hardware, N/A, Warming up of detector started 
All LV and HT off, vaccumm at 1.3e-5 mbar, starting warm up sequence.
Fixed, , Sat Jul 1 17:09:04 2017, e748, MUST2, General, , TIME CAL CHECK must2_time_cal_run40.png
run_0040_CalMust2Histos.root
Fixed, e748, Tue Jul 4 05:08:30 2017, e748, MUST2, Hardware, , MUST2 signql check in offline analysis 
RUN248
MUST2 DSSD XE signal for all telescopes T1-T8 confirmed.
MUST2 DSSD YE signal for all telescopes T1-T8 confirmed.
MUST2 DSSD XT signal for all telescopes T1-T6,T8 confirmed. No T7.
MUST2 DSSD XT signal for all telescopes T1-T4,T6,T8 confirmed. No T5,7.

MUST2 Csi E signal for all telescopes T1-T4,T6,T7 confirmed.
MUST2 Csi t signal for no telescopes T1-T8. This is normal.

MUST2 SiLi E signal for all telescopes T5,T8 confirmed.
MUST2 SiLi T signal for all telescopes T5,T8 confirmed.
Fixed, e748, Tue Jul 4 05:11:20 2017, e748, MUST2, Hardware, , MUST2 signql check in offline analysis 10x
RUN248
MUST2 DSSD XE signal for all telescopes T1-T8 confirmed.
MUST2 DSSD YE signal for all telescopes T1-T8 confirmed.
MUST2 DSSD XT signal for all telescopes T1-T6,T8 confirmed. No T7.
MUST2 DSSD XT signal for all telescopes T1-T4,T6,T8 confirmed. No T5,7.

MUST2 Csi E signal for all telescopes T1-T4,T6,T7 confirmed.
MUST2 Csi t signal for no telescopes T1-T8. This is normal.

MUST2 SiLi E signal for all telescopes T5,T8 confirmed.
MUST2 SiLi T signal for all telescopes T5,T8 confirmed.
Fixed, , Tue Jul 4 14:49:17 2017, e748, MUST2, General, , CsI THRESHOLD RUN 297 Pedestal_adjustment_CsIE.png
By removing the threshold in the CsI we can clearly see now the light particles well separated in the DE/E
new Pedestal suppression window : 8180
8210

In the following picture we can clearly see the difference.
Fixed, e748, Tue Jul 4 18:29:39 2017, e748, MUST2, Software, N/A, Start a new acquisition with Numexo CaptureSResetCHIODig.png
-To start a run :

START Acquisition NUMEXO
START Acquisiton MUST2

Note both run number inside the elog

Don't forget during the run to check if digitizer signal are OK
-> Preamp signal (with baseline)
If not -> STOP RUN MUST2
-> STOP RUN NUMEXO
-> Open DAS
-> Go Online
-> Update Hardware: click cancel
-> Click on VME_CHIO
-> Click inside the « sample number » box and press enter
-> Click inside the « with samples number before STOP » box and press enter
-> Click on Validate
-> Click DAS offline
-> START Acquisition NUMEXO
-> START Acquisiton MUST2

- At the end of the run :

STOP Acquisiton MUST2
STOP Acquisition NUMEXO

- To Convert a NUMEXO run :

ssh -X e748chio@ganp976 //To acces NUMEXO computer
GRU+ // Alias to start the new version of GRU
cd ganacq_manip/e748chio/GRU_NUMEXO
GRU GruConvTree.C(put your run number here)

NUMEXO run are in /data/e748chioX/e748chio/acquisition/run

Quality Control:
- Written by Valerian
- Checked by Nicolas
- Aggreed upon by Franck
- Corrected by Freddy
- Approved by Adrien
Fixed, e748, Wed Jul 5 11:10:48 2017, Valérie L., MUST2, General, CD2, Geometrical configurations for MUST2 ConfigGEOMImpactMUST2e748.pdf
Fixed, e748, Wed Jul 5 11:13:27 2017, Valérie L., MUST2, General, CD2, Power boards HV and LV for MUST2 ConfigHVetLVExpE748MUST2d6v2017.pdf
Fixed, e748, Thu Jul 6 01:00:21 2017, Freddy, MUST2, Hardware, N/A, Problem with position of télescopes 6&7 Nouveau_document_2017-07-06.pdf
Due to a cabling problem telescope 6 was seen as telescope 7 and inversly.
Fixed, e748, Thu Jul 6 05:48:26 2017, e748, MUST2, General, CD2, SiLi 1/T5 trip 
Restart SiLi 1/T5 that reached 26 uA and tripped a few minutes ago.
Current = 21 uA when biased up again, and reaches 24 uA in a few minutes.
Fixed, e748, Thu Jul 6 07:17:05 2017, e748, MUST2, General, CD2, SiLi 1/T5 trip 
SiLi 1/T5 tripped at 7:16.
We turn it on again immediately -> 23 uA
Fixed, e748, Thu Jul 6 07:23:22 2017, e748, MUST2, Software, CD2, MUST2 : VMECOM : TCP error - TCP/IP : time-out 
"MUST2 : VMECOM : TCP error - TCP/IP : time-out" at 7:19.
RRC shows MUST2 "OFFLINE"
We stop run 331 -> Doesn't stop
We try TK, KNA -> no effect
We try KALL, RC -> RC doesn't start
We enter D6 and reboot MUST2 VXI and AGAVA VME and restart RC
No events... -> time out...
Probably a betwork problem
We're trying to get in touch with an astreinte
Fixed, e748, Thu Jul 6 07:58:09 2017, e748, MUST2, General, CD2, SiLi 1/T5 triped 
SiLi 1/T5 triped at 7:30. We leave it off while trying to restart the run control.
We turn it on again at 8:03.
Fixed, e748, Thu Jul 6 10:35:50 2017, Valérie L, MUST2, General, CD2, Sili-1/T5 trip 
The Sili1 of T5 has tripped (again) at 10h30.
On again. 400V; I ~ 20µA at 10h40, still increasing 25.6µA at 11h30.(The limit Io is set at 26µA)
To regulate this detector the Vo set is put at 380V instead of 400V. Now I ~ 24.4µA.
We wil check that the current is stabilized below 24µA, and after the V will be set again at 400V.
Fixed, e748, Fri Jul 7 00:25:16 2017, e748, MUST2, Software, CD2, Calibration for CsI 
Rough energy calibration for CsI was performed (only for MM1 and MM4).

Calibration file is at
/home/e748/analysis/nptool/Projects/e748/Calibration/Energy/Calibration/CsI_test/
Fixed, e748, Fri Jul 7 00:42:50 2017, Shumpei, MUST2, Software, CD2, Calibration for CsI CsICalib.pdf
Rough energy calibration for CsI was performed (only for MM1 and MM4).
Method;
Gate DSSD (300 um) energy = 2 MeV. This corresponds to
p energy remain 12.3 MeV
d energy remain 25.5 MeV
t energy remain 38.7 MeV
Gate DSSD (300 um) energy = 6 MeV. This corresponds to
alpha energy remain 72.5 MeV
4 points liner fit for cristal by cristal.

Calibration file is at
/home/e748/analysis/nptool/Projects/e748/Calibration/Energy/Calibration/CsI_test/
Fixed, e748, Fri Jul 7 00:43:51 2017, Shumpei, MUST2, Software, CD2, Calibration for CsI CsICalib.pdf
Rough energy calibration for CsI was performed (only for MM1 and MM4).
Method;
Gate DSSD (300 um) energy = 2 MeV. This corresponds to
p energy remain 12.3 MeV
d energy remain 25.5 MeV
t energy remain 38.7 MeV
Gate DSSD (300 um) energy = 6 MeV. This corresponds to
alpha energy remain 72.5 MeV
4 points liner fit for cristal by cristal.

Calibration file is at
/home/e748/analysis/nptool/Projects/e748/Calibration/Energy/Calibration/CsI_test/