Pinnede748 Tue Jun 13 11:14:23 2017 Valérie LapouxMUST2General GMT configuration, FAG
The Gatconf parameter is now defined in the action file.
The new configuration for GMT (see chronogramme plot) is attached, with the FAG window width set at 100 ns.
Attachment 1: GMTconfigOKMust2FAG100ns.png
GMTconfigOKMust2FAG100ns.png
Attachment 2: GMTtrigParamActions.png
GMTtrigParamActions.png
Attachment 3: GMTparamDASgatconf.png
GMTparamDASgatconf.png
Pinnede748 Thu Jun 15 10:16:03 2017 Valérie LapouxMUST2Hardware Electronics for GMT trigger and FAG
The GMT is used in a mode where we do not make coincidence and decision, GMT entries are single and all accepted as triggers of the DAQ.
The FAG window for the GMT should be set at a low value, typically 100 ns.
Attachment 1: DaqElectronicsMUST2gmtforE748.pdf
DaqElectronicsMUST2gmtforE748.pdf DaqElectronicsMUST2gmtforE748.pdf DaqElectronicsMUST2gmtforE748.pdf
Fixede748 Wed Jun 28 10:52:15 2017 Valérie LapouxMUST2General Memo for CALIMERO MUST2 Time Calibration
Temporary file indicating the main steps for the time calibration of MUST2 using the Calimero DAQ package program.
Attachment 1: ConfigDAQDasCalimerov2017vlxTMP.pdf
ConfigDAQDasCalimerov2017vlxTMP.pdf ConfigDAQDasCalimerov2017vlxTMP.pdf ConfigDAQDasCalimerov2017vlxTMP.pdf ConfigDAQDasCalimerov2017vlxTMP.pdf ConfigDAQDasCalimerov2017vlxTMP.pdf ConfigDAQDasCalimerov2017vlxTMP.pdf ConfigDAQDasCalimerov2017vlxTMP.pdf ConfigDAQDasCalimerov2017vlxTMP.pdf
Fixede748 Wed Jun 28 10:54:34 2017 Valérie LapouxRUNSoftware DAQ problems due to TCP/IP errors
Problems occurred during the run #29 at 2h38 Wed. 28th June, with the following error messages written in the Run Control GUI window:

Error rcc MUST2:VMECOM :TCP error TCP/IP time-out
Attachment 1: ProblemRun29TCPerror.png
ProblemRun29TCPerror.png
Fixede748 Wed Jun 28 11:02:38 2017 Valérie LapouxRUNGeneral3-alphaCalibration run #31 with Alpha source - MM5 and MM8
Run #31 started at 11:01, Wednesday 28th June.
The alpha source is rotated towards the telescopes 5, 8.
Attachment 1: Run31startNarvalAlphaSource.png
Run31startNarvalAlphaSource.png
Fixede748 Wed Jun 28 15:17:24 2017 Valérie LapouxRUNGeneral End of run 31-status
Run #31 started at 11h01; stopped at 15h13
Problem on ganlx9 VME Chio
TIMEOUT on the stop process.
Attachment 1: Run31stopProbTimeoutGanlx9Chio.png
Run31stopProbTimeoutGanlx9Chio.png
Fixede748 Thu Jun 29 23:26:10 2017 Valérie LapouxRUNGeneralEmptyALL CALIMERO Time Calibration MUVI1
29 JUNE 2017
CONDITIONS FOR CALIMERO CALIBRATIONS
Time calibrator Period 20ns ; range 512 ns
storage /data/e748X/e748/acquisition/run
--------------------------------------------------------------------------
RUN 0035 started 22h01; stop 22:35
RUN 0035 (run_0035.dat.29-06-17_22h01m28s.1) started 22h35 stop at 22h50
MUVI 1 TRIGGER IN GMT: MM1, MM2, MM3, MM4
MATE validated: STRIP-X T (enable MUFEEX, disable SiLi )

1048576000 29 juin 22:35 run_0035.dat.29-06-17_22h01m28s
431554560 29 juin 22:50 run_0035.dat.29-06-17_22h01m28s.1


The time to calibrate all stripXT is 50 minutes, when the statistics requested for one spectrum is 100000.

NB: DSSD Telescope 2 tripped round 23h50 29 june !!! I ~ 4.9 µA
-------------------------------------------------------------------------
RUN 0038 started 23h03 ; stop 00H14 30 juin
MUVI 1 TRIGGER IN GMT: MM1, MM2, MM3, MM4
MATE validated: STRIP-Y T (enable MUFEEX, disable CsI)
Exxx 1048576000 29 juin 23:28 run_0038.dat.29-06-17_23h03m18s
Exxx 1048576000 29 juin 23:53 run_0038.dat.29-06-17_23h03m18s.1
Exxx 846856192 30 juin 00:14 run_0038.dat.29-06-17_23h03m18s.2

--------------------------------------------------------------------------
Attachment 1: CalimeroRunControl.png
CalimeroRunControl.png
Attachment 2: ConfigCalimeroStat.png
ConfigCalimeroStat.png
Attachment 3: CalibTmuvi1Yperiod20nsrange600ns.png
CalibTmuvi1Yperiod20nsrange600ns.png
Attachment 4: TimeMust2X_MUVI1_uncalib.png
TimeMust2X_MUVI1_uncalib.png
Attachment 5: TimeMust2Y_MUVI1_uncalib.png
TimeMust2Y_MUVI1_uncalib.png
Fixede748 Fri Jun 30 00:33:36 2017 Valérie LapouxRUNGeneralEmptyALL CALIMERO Time Calibration MUVI2
30 JUNE 2017
CONDITIONS FOR CALIMERO CALIBRATIONS
Time calibrator Period 20ns ; range 512 ns
storage /data/e748X/e748/acquisition/run
--------------------------------------------------------------------------
RUN 0039 started 0h19 ; stop 00H45

MUVI 2 TRIGGER IN GMT: MM5, MM6, MM7, MM8
BUT ALL MUVI2 MATE at 300 ns !!!!
MATE validated: STRIP-X T (enable MUFEEX, disable SiLi )

The time to calibrate all stripXT is 25 minutes, when the statistics requested for one spectrum is 50000.

Exxx 761004032 30 juin 00:45 run_0039.dat.30-06-17_00h19m45s
-------------------------------------------------------------------------
Attachment 1: CalibTimeMUVI2stripXT.png
CalibTimeMUVI2stripXT.png
Attachment 2: SpectresMUVI2stripXT300ns.png
SpectresMUVI2stripXT300ns.png
Fixede748 Fri Jun 30 01:01:08 2017 Valérie LapouxRUNGeneralEmptyALL CALIMERO Time Calibration MUVI2 GOOD RUNS 600ns
RANGE TAC MUST2 600ns
CALIMERO TIME CALIBRATOR PERIOD 20ns; Range 512ns

RUN 40 started 00H53 ; stop 30 juin 01:19
MUVI 2 TRIGGER IN GMT: MM5, MM6, MM7, MM8
MATE validated: STRIP-X T (enable MUFEEX, disable SiLi)


---------------------------------------------------------
RUN 41 started ; stop 30 juin stop 31st of june 01:47
MUVI 2 TRIGGER IN GMT: MM5, MM6, MM7, MM8
MATE validated: STRIP-Y T (enable MUFEEY, disable CsI)

---------------------------------------------------------
Attachment 1: TimeMust2X_MUVI2_uncalib.png
TimeMust2X_MUVI2_uncalib.png
Attachment 2: TimeMust2Y_MUVI2_uncalib.png
TimeMust2Y_MUVI2_uncalib.png
Fixede748 Fri Jun 30 12:24:17 2017 Valérie LapouxDAQGeneral DAQ Parameters: TAC, Caviar, LISE D4, D6, Caviar
Attachment 1: DASParamVXIMust2CatsTACLise.png
DASParamVXIMust2CatsTACLise.png
Attachment 2: DASParamVXIChioQDC.png
DASParamVXIChioQDC.png
Attachment 3: DASParamVXIChioADClisepar.png
DASParamVXIChioADClisepar.png
Fixede748 Fri Jun 30 16:49:49 2017 Valérie LapouxDAQGeneral GMT triggers and chronograph
Configurations for the GMT inputs.
30 June 2017 pm
all Must2 telescopes,
divided inputs: Cats 1 (IN9) and Cats2 (IN10); Plast (IN11); ChIo (IN12);
TriggerLISE (IN13).
GMT chronograph FAG 100ns; CT 5µs.
Attachment 1: DASConfigTriggerGMT.png
DASConfigTriggerGMT.png
Attachment 2: ChronogrammeGMT30juinFAG100nsCT5µs.png
ChronogrammeGMT30juinFAG100nsCT5µs.png
Fixede748 Fri Jun 30 16:55:04 2017 Valérie LapouxDAQGeneral Run control for global DAQ with NUMEXO
The run start/stop sequence for the global DAQ including the NUMEXO:

I. ssh e748chio@ganp976
pw (same as for the experiment)
II. start_acq e748chio
-->the RC window of the e748chio is opened
III. START (on the RC e748chio)
IV. START (on the RC e748)
V. STOP (on the RC e748)
VI. STOP (on the RC e748chio)
==================================================================================
Attachment 1: RunControlAll748ModeMonitoring.png
RunControlAll748ModeMonitoring.png
Attachment 2: NarvalRunControlAllE748.png
NarvalRunControlAllE748.png
Fixede748 Fri Jun 30 17:53:35 2017 Valérie LapouxDAQGeneral Scalers parameters U2M
Attachment 1: Actionse748ganlx11withU2M.png
Actionse748ganlx11withU2M.png
Attachment 2: ScalerAnalyzerU2M.png
ScalerAnalyzerU2M.png
Fixede748 Fri Jun 30 20:46:16 2017 Valérie LapouxTARGETGeneral TARGET configuration
List of the reaction target in the chamber from bottom to up:

6. EMPTY FRAME (no frame)
5. CD2 2.5 mg/cm2
4. CD2 1.5 mg/cm2
3. CD2 2.5 mg/cm2
2. CD2 1.5 mg/cm2
1. MASK

MASK viewed from the beam coming to the target position :
cf photograph of entry ELOG Id=83 https://caeelog.in2p3.fr/MUST2/83
____________________________
----*-----*-----*------
----------*-------------
----*-----*--*--*---
-------*-----*--------
----*-----*-----*------
_________________________


SYSTEM of 3 blocks to fix the target position :
I small one
II long one III long one; II = III

To have the target n°1 mask: no block
To have target n°2 block I
target n°3: block II
target n°4: blocks I+II
target n°5: blocks II+III
target n°6: blocks I+II+III
Fixede748 Sat Jul 1 14:32:02 2017 Valérie LapouxDAQGeneral Scalers U2M, parameters
U2M configuration +Actions ganlx11

The signals for the scalers are converted from NIM to ECL in a 16 channel module NIM-ECL.
The cable is PHYSICALLY connected from the NIM-ECL module to the U2M on Groups 1 & 2.
Normally we should read these scalers on the U2M from channel 1 to 16 BUT
we found that the good channels are running on channels 17 to 32. See below.
We have defined the actions for all possible channels of the U2M registers 1 to 16 (Groups 1 and 2), and 17 to 32
(Groups 3 and 4)
Attachment 1: ScalersU2Mok.png
ScalersU2Mok.png
Attachment 2: CompilActionsganlx11ScalerGr1to4..png
CompilActionsganlx11ScalerGr1to4..png
Fixede748 Sat Jul 1 14:45:17 2017 Valérie LapouxDAQGeneral Parameters for correlation checkings
The parameters to be used for the checking of the correlations between crates/VME/VXI and good running of the merging
conditions of the different DAQs are :
- for MUST2 VXI with the GMT: GATCONF
- for CATS VXI: DATATRIG
- for CHIO VXI: DATATRIG_CHIO
- for CAVIAR crate: CONFDEV
- for AGAVA: CONFDEV_AGAVA

Check correlations on the following bidim:
parameter T_PL_CATS1 coded in ADC VXI MUST2
parameter T_PLch_CATS1 coded in ADC VXI CHIO

check T_CATS1_CAV
Fixede748 Sat Jul 1 15:12:01 2017 Valérie LapouxONLINEHardware Conditions for Bidiv and TAC 1st July 15pm
(Update the file CONDTIONS748.txt during the experiment)

JULY 1st 15pm

Bidiv = 1 for CATS1 and 2
Bidiv = 10 for Plast and ChIo

TAC ranges

START STOP RANGE PARAMETER ADDRESS VXI MODULE
-------------------------------------------------------------------
-------------------------------------------------------------------
CATS1_FAG CAVIAR 1µs T_CATS1_CAV ADC VXI MUST2 add=19
CATS1_FAG CATS2_FAG 500ns T_CATS1_CAV ADC VXI MUST2 add=20
OU_MUVI CATS1_FAG 500ns T_MUVI_CATS1 ADC VXI MUST2 add=21
PLAST_FAG CATS1_FAG 1µs T_PL_CATS2 ADC VXI MUST2 add=22
PLAST_FAG CATS1_FAG 1µs T_PL_CATS1 ADC VXI MUST2 add=23
-------------------------------------------------------------------
PLAST_FAG CATS1_FAG 1µs T_PLch_CATS1 ADC VXI CHIO add=19
PLAST_FAG CHIO 1µs T_PL_CHIO ADC VXI CHIO add=3
-------------------------------------------------------------------
-------------------------------------------------------------------
Fixede748 Sun Jul 2 08:06:53 2017 Valérie LapouxRUNGeneralCD2Run 77 global check
Conditions of Run 77

2 July - start at 6h29 - stop at 8h38
e748 Exxx 126943232 2 juil. 08:38 run_0077.dat.02-07-17_06h29m23s

N.B: The run is stopped at 8h38 to check the bidim of correlations TPL_CATS1 coded in VXI MUST2 and VXI CHIO.
GMT Triggers all MUST2 T1 to T8
----------------------------------------------------------------------------------------------------
CD2 2.5 mg/cm2 POSITION 3
CATS rate ~ 10 K/s to 12K /s; SCaler Analyzer see plot below
Muvi1 and Muvi2 counting rates: plots below

The merge configuration is checked with the parameters CONFDEV GATCONF etc...see plot below at 8h00
----------------------------------------------------------------------------------------------------
Attachment 1: CheckMergeConf2july17at8h00.png
CheckMergeConf2july17at8h00.png
Attachment 2: RunControlOnlineNarvalRun77.png
RunControlOnlineNarvalRun77.png
Attachment 3: ScalerAnalyzerRun77At8h15.png
ScalerAnalyzerRun77At8h15.png
Attachment 4: ScalerMuvi1Run77.png
ScalerMuvi1Run77.png
Attachment 5: ScalerMuvi2Run77.png
ScalerMuvi2Run77.png
Attachment 6: GMTConfigRun77.png
GMTConfigRun77.png
Fixede748 Sun Jul 2 08:40:25 2017 Valérie LapouxRUNGeneralCD2Run 78 - 2 July - 18O beam
Run #78 CD2 2.5 mg/cm2 position 3 - 18O beam
Same conditions as for Run 77
Triggers all MUST2, T1 to T8, GMT IN1 to IN8
RUN 78 2nd July START at 8h39, STOP 10h01
e748 Exxx 92405760 2 juil. 10:01 run_0078.dat.02-07-17_08h39m30s

STOP of the beam and of the run to enter in D6, to make some checking of electronics and of the timing.
Attachment 1: Run78ConfdevDataTrig.png
Run78ConfdevDataTrig.png
Attachment 2: RUN78tPLcats1CORREL.png
RUN78tPLcats1CORREL.png
Attachment 3: Run78CorrelWindowtimePlastCats1.png
Run78CorrelWindowtimePlastCats1.png
Attachment 4: Run78TACplastCats.png
Run78TACplastCats.png
Attachment 5: Run78TrigMM2impact.png
Run78TrigMM2impact.png
Fixede748 Sun Jul 2 08:46:13 2017 Valérie LapouxDAQHardwareCD2Summary of the TAC conditions
JULY 2nd 8pm

Bidiv = 1 for CATS1 and 2
Bidiv = 1 for Plast and ChIo

TAC ranges

START STOP RANGE PARAMETER ADDRESS VXI MODULE
-------------------------------------------------------------------------------------------
-------------------------------------------------------------------------------------------
CATS1_FAG CAVIAR (del 550ns) 1µs T_CATS1_CAV ADC VXI MUST2 add=19
CATS1_FAG CATS2_FAG (del 33ns) 200ns T_CATS1_2 ADC VXI MUST2 add=28
OU_MUVI CATS1_FAG 500ns T_MUVI_CATS1 ADC VXI MUST2 add=21
CATS2_FAG PLAST (val) 1µs T_PL_CATS2 ADC VXI MUST2 add=22
CATS1_FAG PLAST (no val) 1µs T_PL_CATS1 ADC VXI MUST2 add=23
-------------------------------------------------------------------------------------------
CATS1_FAG PLAST (no val) 1µs T_PLch_CATS1 ADC VXI CHIO add=19
PLAST val Gamer ChIo CHIO (no val) 2µs T_PL_CHIO ADC VXI CHIO add=3
-------------------------------------------------------------------------------------------
TAC EXL HF 100ns EXL_HF ADC VXI MUST2 add=18
-------------------------------------------------------------------------------------------

ELOG Home Page