Fixed, e738, Sun Jul 15 08:04:12 2018, daisuke, RUN, General, Cryo-empty, RUN 397 32x
|
9C + empty.
08h00 start. 12C 1.8 micro A.
|
Fixed, e738, Sun Jul 15 10:04:13 2018, daisuke, RUN, General, Cryo-empty, RUN 398
|
9Cc + empty
10h01 start
|
Fixed, e738, Sun Jul 15 13:57:59 2018, daisuke, RUN, General, Cryo-empty, RUN 415 34x
|
9C + empty run.
From 10 to 13h45, we had several issues with DAQ. All data from RUN 398 to 414 are JUNK.
|
Fixed, e738, Mon Jul 16 15:13:21 2018, daisuke, RUN, General, 3-alpha, RUN 419  
|
MUST2 3 alpha source at center
13h22 start
15h05 stop. |
Fixed, e738, Mon Jul 16 16:13:00 2018, daisuke, RUN, General, 3-alpha, RUN 420   
|
MUST2 3 alpha shooting a bit left
15h10-16h08 |
Fixed, e738, Mon Jul 16 16:44:43 2018, daisuke, RUN, General, 3-alpha, RUN 422
|
MUST2 + 3 alpha shooting left |
Fixed, e738, Mon Jul 16 17:25:22 2018, daisuke, RUN, General, 3-alpha, RUN 422  
|
MUST2 + 3 alpha shooting right. |
Fixed, e738, Mon Jul 16 18:46:34 2018, daisuke, RUN, General, 3-alpha, RUN 423   
|
MUST2 + 3 alpha shooting center. |
Fixed, e748, Tue Jul 4 05:01:21 2017, Yorick, RUN, General, CD2, Runs 248-250
|
These are long runs with CD2
MUST8 is in GMT 15.
Missing Times: T7 X and Y; T5 Y.
|
Fixed, e744, Wed May 30 00:17:02 2018, Valérie, Louis, RUN, General, CH2, Run #2114 8x
|
[B]RUN #2114 30 mai 2018 start @ 0h15; stop @ 2h58[/B]
BEAM STOP DUE to the shut down of the deviation element at the entrance of our D6 area.
target n°4. CH2 104 µm
|
Fixed, e744, Wed May 30 01:15:58 2018, Valérie, Louis, RUN, General, CH2, Run #2115 6x
|
[B]Since 2h58 : WAITING FOR THE BEAM TO START THE RUN[/B]
[B]RUN #2115 30 mai 2018 start @ 03h20; stop @ 4h56[/B]
|
Ongoing, e744, Wed May 30 03:09:09 2018, Valérie, Louis, RUN, General, CH2, BEAM LINE PROBLEMS, alarm "water leakage"
|
The beam was stopped at 4h56, due to the alarm of "water leakage" on equipments, indicated in the D6 area.
All QPole in D6 were automatically put to 0.
Wien filter and DAP were put OFF to stop the beam and enter in the D6 area.
|
Fixed, e744, Thu May 24 17:23:57 2018, Valérie for Calimero team: Valérian, Louis, MUST2, General, N/A, CALIMERO Runs 453-457 OK 16x
|
Calimero on ganp1074 in D6
Time Calibrator Range: 640 ns; Period 20 ns Amplitude of pulser (test generator) 9MeV
Run 453 Telescope T5 (MUVI2-slave) XT see plot
|
Fixed, e744, Thu May 24 17:18:58 2018, Valérie for Calimero team : Valérian, Louis, MUST2, General, N/A, CALIMERO Tests Runs 451 to 452 (done in D6)  
|
Test runs for telescopes T1 to t4
Nb: The applied threshold is now 1 MeV but it seems to be not the case when we look at the spectra.
Maybe a problem of the read configuration in GECO.
|
Fixed, e744, Thu May 24 12:01:54 2018, Valérie for Calimero team - Valérian, Fairouz, MUST2, General, , Bug server Calimero Run #447-449 12x
|
Calimero on ganp161
Telscopes T1 to T4 thresholds for T1 to T3 400 keV ; T4 : 1 MeV
ampli pulser 12 MeV
|
Fixed, e738, Mon Jul 9 18:03:48 2018, Valérie Louis, RUN, General, Cryo-LH2, RUN 312 25x
|
Run 312
First RUN of 9C on filled LH2 target
|
Fixed, e748, Thu Jun 8 18:57:14 2017, Valérie Lapoux, MUST2, Hardware, , Currents and Voltages on MUST2
|
Thursday 8th June.
Vacuum in the chamber 9e-05 mbar; MUST2 temperature at -5°C.
Low voltages and HV ON
|
Pinned, e748, Fri Jun 9 15:49:46 2017, Valérie Lapoux, MUST2, Hardware, , MUST2 configuration 
|
The MUST2 configurations for telescopes in the chamber and low/High voltage Caen crate are given in the attached file. |
Pinned, e748, Fri Jun 9 15:51:44 2017, Valérie Lapoux, MUST2, Hardware, , General Trigger GMT for MUST2 electronics
|
The GMT configuration for the trigger inputs and the inputs from MUST2 electronics are given in the file. |
Fixed, e748, Mon Jun 12 22:48:45 2017, Valérie Lapoux, MUST2, General, , Tests of the DAQ with the Alpha Source 8x
|
12Th June. 3-peak Alpha source rotated towards the telescopes MM1 to MM4 (square wall of 4 telescopes).
MUVI configurations are fixed on the DAS. See pictures below. Thresholds : 402 keV.
We have DAS error messages for telescopes T2 and T7 with problems of data transmission, "I2C errors" = logic signals problems, maybe due to
|
|