Fixede744 Wed May 23 10:57:13 2018 megumiDAQGeneral Photo of the circuitphoto of the circuit area  15x 
Fixede744 Wed May 23 13:15:47 2018 megumiDAQGeneralN/ATime calibration for TDC (EXL)Time calibrator setting
Range 5.12 us
Period 160 ns
 Capture_du_2018-05-23_13-29-34.png 
Pinnede744 Wed May 23 15:10:15 2018 iulianOTHERGeneralN/AProcedure to start stop RUNS   fiche_start_run.pdffiche_stop_run.pdf 
Fixede744 Wed May 23 15:40:58 2018 Charles Houarner ValérieMUST2SoftwareN/ATESTS MUVI internal pulser T1-T4 strips XTo check the signals and trigger on T4 we
used the internal pulser on T4, 
from the SYNCHROTEST pulser at 150 Hz.
 testGeneInterneT4plotCh5Mate.pngtestGeneInterneT4plotCh5MatePied.pngTestMust2tel4matePulserInt.pngTestMust2tel4PulserIntMate5.pngTestMust2telT1toT3andT5mat5onT4.png 
Fixede744 Wed May 23 15:42:04 2018 Louis, ValérieMUST2GeneralN/ACALIMERO run 409 - XT - T1 to T4Started run #409 
GMT triggers: GecoCalimeroMuviGMT.png 
HT on cf : HTtelescopesMustsWed23May.png
 GecoCalimeroMuviTel4Thr1MeV.pngconfigCalim1.pngconfigCalimOKexterne.pngGecoCalimeroMuviGMT.pngHTtelescopesMustsWed23May.png 
Pinnede744 Wed May 23 17:23:34 2018 FreddyMUST2General Pedestals and alpha calibration analysisCalibration coefficients for MUST2 telescopes
were extracted from run_0118 (acquired during
night from 13th to 14th of May). They are
 Plot_DiffPedestals.png 
Fixede744 Wed May 23 18:20:59 2018 e744MUST2GeneralN/ATest Calimero Run 425Started run #425 Calimero  NEW XT  T1toT4
ampl Pulser 12MEV; thr for T4 1 MeV
problem on data taking
  
Ongoinge744 Wed May 23 20:52:01 2018 Iulian ValerianRUNGeneral run #429 and #430 and config gmtChanged VAL from 2 us to 2.5 us

run #429 exl ppt triggers
 config_gmt.pngconfig_gmtslave.pngrun430_E_PPT_vs_T_PPT.pdfrun430_E_PPT_proj.pdfrun430_E_EXL_vs_T_EXLor.pdf 
Fixede744 Wed May 23 23:37:14 2018 Valérie L.MUST2GeneralN/AMUVI configuration DASConfigurations files of the MUVI 1 MufeeX
and Y.
On MufeeX and Y configuration:
 13x 
Fixede744 Thu May 24 01:02:19 2018 ValerianOTHERGeneralN/Arun #431[U][B]run #431[/B][/U]
Trigger LISE
Beam in D4
 ED4_TD4_23-05-18_00-58.png 
Fixede744 Thu May 24 01:10:30 2018 iuliqnRUNGeneral run 433 Lise triggerShould be ql foil in front of the si detector....   
Fixede744 Thu May 24 01:11:26 2018 Iulian ValerianRUNGeneralN/Arun 434 Lise triggerCats inserted

efficiency is around ~99%
 ED4_TCATSHF_23-05-18_1-18.pngED4_TCATSHF_23-05-18_1-18_efficiency.png 
Fixede744 Thu May 24 01:53:28 2018 iulianRUNGeneralN/Arun 438 Lise trigger run 438  D4 in
run 439 d6 in.
 run_439_d6_cats_hf.pngrun_439_transmisiond4_d6.png 
Ongoinge744 Thu May 24 02:30:52 2018 iulianRUNGeneralN/ARUN 440 14N no target trigger Must & cats %100RUN 440 
14N beam  \
no target 
 run440.png 
Fixede744 Thu May 24 03:21:37 2018 iulianOTHERHardwareN/APosition measurements Must2/PPT/EXL   STP-2018-E054_E744_I-Stefan_J-Mrazek_LISE-D6.pdf 
Fixede744 Thu May 24 03:57:34 2018 iulianRUNGeneralN/Arun 442 Lise trigger d6   cats_e1_d6_t1_D6_run442.png 
Fixede744 Thu May 24 04:20:34 2018 iulianRUNGeneralN/Arun 443 T1-t5 triggersrun 443
T1-T5 triggers
 mm5_run443.pngmm5_2_run443.pngmm5_3_run443.pngmm5_4_run443.png 
Pinnede744 Thu May 24 05:44:56 2018 iulianRUNGeneralN/AImportant::analysis of the run 443/ things to do[I][B]No stop on t5, but TAC MM_CATS ok..
So two possibilities: 
1) Stop Cable not connected on Muvi2 
 t_mm_PPT_run443.pdft_mmhf_run443.pdft_mm_exlor_run443.pdfcorrelation_run443.pdf 
Ongoinge744 Thu May 24 05:59:44 2018 iulianMUST2GeneralN/Arun 444 t1-t4 trigger no target 14n beamrun 444 
t1-t4 trigger
 no target 
 mm5_8_run445.pngmm5_7_run444.pngmm5_6_run444.pngmm5_5_run444.pngmm5_4_run444.png 
Ongoinge744 Thu May 24 06:30:27 2018 iulianRUNGeneralN/Arun 445 t1-t4 trigger no target 14n beam no CATS   mm5_run445_3.pngmm5_run445_2.pngmm5_run445_1.png 