MUST2 SAMURAI_2018 S3-LEB-LPC SUPERNEMO MUGAST EXPAND SCALP GALATRON HiCARI VELO
  MUST2, Page 18 of 48  Not logged in MUST2
New entries since:Thu Jan 1 01:00:00 1970
Ongoing, e744, Thu Apr 26 19:37:24 2018, Valerian and Freddy, MUST2, Hardware, N/A, Debug of Must2 telescopes debug_mm_telescopes.pdfProblem_on_T5_T6_cable_swap.pdf
Today we found different problems, no time on T4 and no signal on T5 and T6 CsI tripping. After changing cables and a lot of tests with the chamber open
and only the BT ON, T4 and T5 problems seemed to be fixed. 
Ongoing, e744, Sat Apr 28 10:17:22 2018, Valerian and Iulian, MUST2, Hardware, 3-alpha, Status of MUST2 telescopes 27/04/18 Third_good_run_Energy_and_time_for_5_Must2_detectors_2018-04-27_19-32-23.png
Yesterday night we tested T1, T2, T3, T4, T5, and T6.

All telescopes (except T6 which still have a "tripping" CsI) have an Energy and Time signal on X and Y!
Ongoing, e744, Sat Apr 28 13:27:26 2018, Valerian and Iulian, MUST2, Hardware, 3-alpha, multiples runs with two alpha source on T1 T2 T3 T4 and T5 
For the following runs we will use two 3 alpha sources :

On T1, T2, T3, and T4 : [B]11615[/B] : Flux = 1496 alpha in 2 pi
Ongoing, e744, Sat Apr 28 13:36:52 2018, Valerian and Iulian, OTHER, Software, N/A, Problem with DAS configuration 
There is an issue with the GMT slave. When you click Online and then apply write hardware, if the message : [U]register error on GMTSlave[/U] appear, [B]reload
a functioning DAS config[/B] and [B]do not write hardware twice[/B]. 
Pending, , Sat Apr 28 21:12:55 2018, iulian, MUST2, General, 3-alpha, Run 182 end ; problem with cooling end_result_alpha_source_28_April.png
RUN 182 start @13h
Stoped @ 21H
Fixed, e744, Sun Apr 29 20:37:58 2018, Francois, CATS, General, , Chronogram chrono.jpg
 
Fixed, e744, Mon Apr 30 20:38:21 2018, iulian, RUN, General, 3-alpha, 6run 186 3a source 60 co source 
[U][B]run #186[/B][/U] 

start@11h 30/04
Fixed, e744, Mon Apr 30 20:42:34 2018, iulian, RUN, General, 60Co, run 188 60 co source 
[U][B]run #188[/B][/U] [I]60co source EXL+PPT trigger[/I]

Started  @20h42 30/04
Fixed, e744, Tue May 1 10:47:41 2018, iulian & valerian, RUN, General, 60Co, run 189 60 Co source 
[U][B]run #189[/B][/U] [I]60co source EXL+PPT trigger[/I]
Changed the way of codding PPT. for this run ppt is coded with the QDC using first dynode.
Started  @10h48 01/05
Fixed, e744, Wed May 2 18:11:59 2018, Iulian Marlenne Louis, RUN, General, 3-alpha, 3 alpha test run_191.png
Run191 start 18h stop 18h10 
Run ok, saved config DAS with good polarity on the thresholds CSI & piedestal allignement on MM1-MM5
Ongoing, e744, Thu May 3 08:50:17 2018, François, VACUUM, General, , stop vacuum 
turbo pumps stopped at 8H45

problem with the cooling system of the M2C chamber, the liquid was in the pipe but it was stopped, no flow, with a lot of "dusts" (vert de gris) => decision
Fixed, e744, Thu May 3 15:04:03 2018, Iulian Marlenne, MUST2, Hardware, N/A, X and Y possitions on the detector 
Telescope 1 : PCB 5 (ref on pcb: 2274)
Telescope 2 : PCB 4
Telescope 3 : PCB 7
Fixed, e744, Thu May 3 15:20:16 2018, Iulian Marlenne, MUST2, Hardware, N/A, X and Y possitions on the detector 
Telescope 1 : PCB 5 (ref on pcb: 2274)
Telescope 2 : PCB 4
Telescope 3 : PCB 7
Ongoing, e744, Thu May 3 19:11:14 2018, Valerian Marlene and Francois, MUST2, General, 3-alpha, run 3 alpha T5 
[U][B]run #196[/B][/U]
3 alpha source and pedestals supressed
Trigger T5 only
Fixed, e744, Fri May 4 11:20:50 2018, Valerian, MUST2, General, 3-alpha, T5 : 0° telescope  StripX_vs_StripY_T5_100V.pdfSi_E_T5_100V.pdf
After increasing the voltage on T5 DSSD from 80V to 100V the resolution increased from ~40keV sigma to 20keV sigma.

StripX vs StripY bidim and the 3 alpha peaks are joined to this entry.
Fixed, e744, Fri May 4 23:58:07 2018, iulian, RUN, General, 3-alpha, Run #203 alfa source & 60co source run_203_ht.pngrun_203_ppt.pngrun_203_EXL.pngrun_203_must2.png
[U][B]run #203[/B][/U]

alpha source & 60co source
Ongoing, e744, Sat May 5 11:14:33 2018, Iulian & Valerian, RUN, General, 3-alpha, run #204 alpha source BT_tripped_T5.pngT5_das_no_cooling.pngT5_das_no_cooling2.pngT5_vigru_no_cooling.png20180506_152338.jpg
[U][B]run #204[/B][/U]
alpha source
start @11h15 05/05
Fixed, e744, Sun May 6 17:52:21 2018, Valerian, RUN, General, 3-alpha, Run #205 T1 T2 T3 & T4 
[U][B]run #205[/B][/U]
T1 T2 T3 & T4 T5 still in trigger but no HT/BT
start @15h43
Ongoing, e744, Sun May 6 17:55:05 2018, Valerian, OTHER, General, 3-alpha, Update on the cooling system problem 6x
After waiting for 1-2 hours. I started the BT again on T5 no tripping BT anymore. While writing hardware with DAS T5 responded well.

After starting the HT, i started a new run :
Fixed, e744, Mon May 7 10:42:58 2018, Valerian, OTHER, General, 60Co, Update on the cooling system and run gamma (signal problem on PPT) HT_EXL.pngEXL_spectra_run207.pngPPT_spectra_run207.pngEXL_spectra_run209.png
Today, both cooling system are working fine and their levels are OK.
The vacuum are 7e-6 mbar in M2C and 2e-5 in the 0 degree chamber.

ELOG Home Page