MUST2 SAMURAI_2018 S3-LEB-LPC SUPERNEMO MUGAST EXPAND SCALP GALATRON HiCARI VELO
  MUST2, Page 12 of 48  Not logged in MUST2
Status ExpNbr Date Author Type Category Target-Source Subject Text Attachments
Fixede748 Thu Jul 6 07:23:22 2017 e748MUST2SoftwareCD2MUST2 : VMECOM : TCP error - TCP/IP : time-out"MUST2 : VMECOM : TCP error - TCP/IP : time-out"
at 7:19.
RRC shows MUST2 "OFFLINE"
  
Fixede748 Thu Jul 6 07:58:09 2017 e748MUST2GeneralCD2SiLi 1/T5 tripedSiLi 1/T5 triped at 7:30. We leave it off
while trying to restart the run control.
We turn it on again at 8:03.
  
Fixede748 Thu Jul 6 08:22:08 2017 Valérie LRUNGeneralCD2Problem of DAQ and networks problemsAfter the problem on Run control and the offline
of MUST2, the DAQ on numexo could not be
started again.
 ProblèmeDAQ6juillet8h.pngProblemGUIRuncontrolNumExo.pngRebootsoftCrateAGAVApassword.pngProblemDAQ5juilletNumExo.png 
Fixede748 Thu Jul 6 09:54:53 2017 Valérie LRUNGeneralCD2Run control OK -Runs 339 and 340After the reboot soft of the AGAVA NUMEXO
and realignment of the TGS (time stamp Agava)
the situation is stabilized.
 CorrelBidimChioandplotCatsRun340.pngRun339scalers.pngScalersAnalyserRun340.png 
Fixede748 Thu Jul 6 10:35:50 2017 Valérie LMUST2GeneralCD2Sili-1/T5 tripThe Sili1 of T5 has tripped (again) at 10h30.
On again. 400V; I ~ 20µA at 10h40, still
increasing 25.6µA at 11h30.(The limit Io
  
Fixede748 Thu Jul 6 10:39:09 2017 BéaF & ValérieL - shift UOFFLINEGeneral Test of merge on Run 339spectra of the merge checked by Béa.
The merge is correct on the correlations
cf plots below.
 run339_ICEdiff_LTSDIff_TrigM2.pngrun339_TAC_LTSDIff_TrigM2.png 
Fixede748 Thu Jul 6 11:41:20 2017 Valérie LDAQGeneralN/AMEMO START/STOP + AGAVA configuration in DASSTART/STOP of the DAQ
---------------------------------------------------------------------
START acquisition e748chio  (DAQ Numexo;
 AfterRebootAgavaRegStatusOx80entréeAfterAlignt.pngDasVMEChioCheckSamplesNumber.pngRunControl748On.pngRunControlNarvalE748chioON.pngParameterListWatcherOnRCe748chio.png 
Fixede748 Thu Jul 6 13:21:49 2017 DaisukeRUNHardwareCD2RUN340During RUN340 

13h10 The beam intensity dropped from 35
  
Fixede748 Thu Jul 6 13:33:23 2017 e748RUNGeneralCD2Stop of Run 340 due to beam problemsThe run 340 was stopped at 13h32. Before the
stop fo the run the beam was unstable and
stopped by machine team.
  
Fixede748 Thu Jul 6 13:37:22 2017 Valérie LRUNGeneralCD2Run 341Run 341 START AT 13h37 STOP AT 15h21 (beam
stop see the ELOG entry Id=239)
At the beginning (cf scalers below) the beam
 ScalersRun341Beginning.pngScalersRun341At14h35.png 
Fixede748 Thu Jul 6 13:37:37 2017 Adrien MattaOFFLINEGeneralN/AEnergy loss table for d, 3He and 3HHere it is!  20x 
Fixede748 Thu Jul 6 14:07:20 2017 BeaOFFLINEGeneralCD2Convert & Merge Numexo Runs in ganp166To Convert run DAQ_general

offline
  
Fixede748 Thu Jul 6 15:24:25 2017 e748-shift UBEAMGeneralCD2Beam stop, end of run 341The beam was stopped due to vacuum problem
at CSS2.
End of run 341 at 15h21.
  
Fixede748 Thu Jul 6 17:05:51 2017 Valérie LRUNGeneralCD2run 342 +overview of TACBeam recovered after shut down due to the
vacuum problem (power supply on the vacuum
system was off). Beam was off during 1h30.
 ScalersRun342at17h10.pngCorrelDatTrigGatconfRun342.pngCorrelTpulserChiorun342.pngRun342_Tcats12.pngRun342_TACcats1.png 
Fixede748 Thu Jul 6 19:17:12 2017 e748 MARUNGeneralCD2RUN 343Run 343
same conditions as run 342
beam=7uA
  
Fixede748 Thu Jul 6 20:07:46 2017 Daisuke + Thomas R+ Valérie LCHIOGeneralCD2Problem of counting on ChioIt seems that the ChIo is counting at a very
low rate, around 100/s instead of 5000/s
in previous runs.
 ScalersRun343At20h09.png 
Fixede748 Thu Jul 6 20:46:15 2017 Thomas R + shift U (Valérie L) +S (Daisuke, Marlène, Shumpei) RUNGeneralCD2Run 345 DAQ+344 chio after chio problemThe HV on cathode is now set again at 2900V.
At 20h50 we get back the beam for the run.
(Grid still ok at 920V)
 ScalersRun345at20h54.png 
Fixede748 Thu Jul 6 21:27:52 2017 Thomas R + shift U (Valérie L) +S (Daisuke, Marlène, Shumpei) RUNGeneralCD2Run 345 beam intensity lossThe beam rate was low after intervention with
the CHIO HV. 
  
Fixede748 Thu Jul 6 21:35:29 2017 Thomas R + shift U (Valérie L) +S (Daisuke, Marlène, Shumpei) RUNGeneralCD2Run 346 e748+e748chio
Run 346 started at 21h37
Beam around 7µA CATS 2 46k
 6x 
Fixede748 Fri Jul 7 00:25:16 2017 e748MUST2SoftwareCD2Calibration for CsIRough energy calibration for CsI was performed
(only for MM1 and MM4).
  

ELOG Home Page