MUST2 SAMURAI_2018 S3-LEB-LPC SUPERNEMO MUGAST EXPAND SCALP GALATRON HiCARI VELO
  MUGAST, Page 67 of 132  Not logged in MUGAST
Fixed, e768s, Fri Jul 12 17:51:06 2019, mugast (Sylvain, Chloe, François, Marlène, Nicolas), OTHER, General, , Monitoring of beam profile with BAF2 
In order to provide a efficient way for PCP to monitor beam profile a new TAC measurement has set up. 

A BAF2 detector has been inserted close to the reaction chamber (in position 7 of AGATA structure frame). Operating voltage of BaF2 is 1800V and the typical
Fixed, TEST, Wed Feb 12 16:24:52 2020, Marlène, Freddy & Franco, MUST2, Hardware, , Modifications on the electronic scheme 
We cleaned the electronic scheme.
Now the HF CLEAN VAMOS is taken directly from VAMOS and not re-cleaned by us.
TACs are all ok. Inspection lines have been checked and labeled.
Fixed, TEST, Wed Dec 4 19:19:38 2019, Marlène, GRIT, Hardware, , Modifications of set-up 
We have installed the new MUFEE board in the reaction chamber for MG2. This board is a new version with ATHED.

We have moved the MG9 board to become the board to read the future MUST2 detector at 90 deg. This board is now perpendicular to the other ones. We have
Fixed, e744s, Thu Apr 11 02:12:42 2019, François, TARGET, General, , Measured target thicknesses 

[COLOR=blue]CATS2[/COLOR]
Incident beam 14N7+  Brho 0.79 Tm
Fixed, e768s, Mon Jul 15 14:29:47 2019, Marlène, MUST2, General, , Masks for MUST2 & Kapton changed for MG5 IMG_20190715_121646_crop_flip.jpgIMG_20190715_122035.jpg
Masks are now correctly mounted

All 4 kaptons from MG5 have been changed
Fixed, e768s, Fri Jul 12 12:07:56 2019, mugast, OTHER, General, N/A, Masks for MUST2 masks_MUST2.jpgmasques_Must_pour_Mugast.pngmatrixImpact_shield_MM2.png
Masks for MUST2 are now mounted. 

NOTE: one mask is not properly screwed (top left) and should be mounted again on Monday morning when we open.
Fixed, com2019, Fri Apr 5 11:26:09 2019, Adrien, Freddy and the world, OFFLINE, General, N/A, Mask reconstruction CATS1-CATS2 run 223 MaskCATS1CATS2_run223.pdfmugast.detectorConfigCATS.dat
Mask between CATS1 and CATS2 in Z=-2190 Reconsctruction with nptool and attached mugast.detector and ConfigCATS.dat attached.

The beam seems to be shifted strongly to the [B]left[/B] of the beam line during the run. not clear yet if the shift of the mask is due to :


 shift of cats
shift of the mask itself
Fixed, com2019, Thu Apr 4 14:41:52 2019, Jenn, TARGET, General, N/A, Mask Target_Frame.jpg
[IMG]elog:3696/1[/IMG]

Image of the Mask position in the target frame.
Fixed, e793s, Wed Mar 3 17:18:42 2021, Franco, GRIT, General, N/A, MUVI's scheme and connections on the chamber connections_chamber_MUGAST.pngMUVI.PNG
 
Fixed, TEST, Mon Mar 4 14:34:31 2019, Valerian, Marlène, Iulian, MUST2, General, N/A, MUST2 positions (based on e755) Screenshot_2019-03-04_at_14.39.02.png
Based on experiment e755, the MUST2 config is the following :

Fixed, e768s, Wed Jul 17 09:50:44 2019, mugast, MUST2, General, N/A, MUST2 CAEN alim burned down 
Yesterday at around 23h the CAEN alim stopped working.
 - The 48V power supply is blown up
 - The Main controller is still starting
Fixed, e793s, Fri Jan 29 15:11:54 2021, Adrien, VACUUM, General, N/A, MUGAST undervacuum and powered up 
MUGAST is undervacuum thanks to Arnaud and Laurent. 

I switch on all BT and HT. everything fine so far. Keeping the HV to check there is no trip on the silicon
    Fixed, TEST, Tue Feb 2 16:41:17 2021, Franco, VACUUM, Hardware, N/A, MUGAST undervacuum and powered up 
I put back the supply of MM1 to the channel 1 of the MUST2 box (as in the normal configuration) and polarized the detectors to make a rapid re-check. I
didn't see any detector tripping. MM1, switched on only for a couple of minutes, had a stable current at 1.3 uA. The stability of the detectors over time
should anyway be checked better tomorrow leaving them polarized for a longer time.
Fixed, e786s, Mon Jun 3 18:00:10 2019, Marlène, GRIT, General, , MUGAST detectors status --> MG4T  
The problem of MG4T ha sbeen solved by changing the feedthrough.
The pulser on Y was not working and we were seeing no events (no ORD) because there was a problem with the bias of board. The issue is due to the feedthrough.
So now MG4T (HT &BT) are plugged in a free feedthrough (below MG1T) and I see pulser signals on Y. 
Fixed, e775s, Fri Feb 28 22:58:31 2020, Franck, Sylvain, ONLINE, General, CD2, MUGAST Spectra Run 153 RUN153_ElabThetaLab.pngRUN153_impact.pngRUN153_tac.pngRUN153_tof.png
Run 153 (target #2 CD2+Au)

MUGAST Spectra reset at start of run (~ 20h)
Fixed, e775s, Thu Feb 27 19:29:24 2020, Chloé, Franck, ONLINE, General, CD2, MUGAST Spectra RUN143_ana_Elab_Thetalab_19h23.pngRUN143_impact_19h24.pngRUN143_tac_19h25.pngRUN143_tof_19h26.png
 
Fixed, e775s, Fri Feb 28 00:35:02 2020, Chloé, Franck, Michal, ONLINE, General, CD2, MUGAST Spectra RUN143_ana_Elab_Thetalab_0h32.pngRUN143_impact_0h30.pngRUN143_tac_0h32.pngRUN143_tof_0h31.png
 
Fixed, e793s, Fri Mar 12 09:55:30 2021, Franco, GRIT, General, CD2, MM5 square_shifted_theta.pngsquare_shifted_Z.png
The first plot attached has been done by artificially removing 7 deg in theta lab, just to see if the the kinematic lines of 47K(d,d) and 47K(p,p) can be
reproduced. Of course the energy losses are not optimized in this case but anyway the agreement seems nice.
In the second plot I moved MM5 forward (in z) by 17.5 mm, without any re-orientation in x and y. We should compare this position with the one measured
Fixed, TEST, Tue May 28 11:08:10 2019, mugast, MUST2, Hardware, 3-alpha, MG3 is tripping 
MG3T is tripping, tryied to set max current to 20uA but it still trip around 30V.
    Fixed, TEST, Fri Feb 14 10:49:22 2020, Marlène & Franco, RUN, General, 3-alpha, MG11 issues 
We analyzed the behaviour of the annular. We realized that the 4-peaks behaviour on X was already present last year but only on one sector, now it's on
two sectors. We noticed that there is a correlation between the malfunctioning sectors and the missing strips on Y. Last year there was only a missing
strip on Y, affecting only one sector on X; now 3 strips are missing on Y, affecting 2 sectors on X. We believe that the fact that the boundings are missing