MUST2 SAMURAI_2018 S3-LEB-LPC SUPERNEMO MUGAST EXPAND SCALP GALATRON HiCARI VELO
  MUGAST  Not logged in MUGAST
Message ID: 5562     Entry time: Wed Feb 12 16:24:52 2020
Author: Marlène, Freddy & Franco 
ExpNbr: TEST 
Type: MUST2 
Category: Hardware 
Status: Fixed 
Target-Source:  
Subject: Modifications on the electronic scheme 
We cleaned the electronic scheme.
Now the HF CLEAN VAMOS is taken directly from VAMOS and not re-cleaned by us.
TACs are all ok. Inspection lines have been checked and labeled.
GMT and Scalers are like below.

GMT:
1 - MUVI 1 (MG1, MG3, MG4, MG5)
2 - MUVI 2 (MG7, MG2, MG6, MG11)
3 - MUVI 3 (MM1, MM2, MM3, MM4)
4 - MUVI 4 (MG9 90-deg MUST2)
5 - COINCIDENCE VAMOS-AGATA
6 - VAMOS DIV
7 - MUST2 DIV
8 - broken
9 - SQUARE DIV
10 - AGATA DIV
11 - VAMOS
12 - empty
13 - empty
14 - empty
15 - broken
16 - empty

SCALERS:
1 - FAG
2 - OR MUGAST
3 - AGATA
4 - VAMOS
5 - empty
6 - DEAD TIME MUGAST
7 - 100 Hz PULSER
8 - DEAD TIME
9 - MUVI 1 (MG1, MG3, MG4, MG5)
10 - MUVI 2 (MG7, MG2, MG6, MG11)
11 - MUVI 3 (MM1, MM2, MM3, MM4)
12 - MUVI 4 (MG9 90-deg MUST2)
13 - empty
14 - empty
15 - CATS2
16 - FINGER

ELOG Home Page