Fixed, TEST, Tue Mar 5 18:03:24 2019, iulian Marlene, MUST2, Software, N/A, Calimero problem on Y side 
|
Calimero not working properly on Y side of any mm detector |
Fixed, TEST, Tue Mar 5 18:18:46 2019, iulian Marlene, MUST2, Hardware, 3-alpha, run 97 3a run Muvi3 night run
|
Run 87
stop@ 5:42 am
3a run Muvi3 (MM)
-4 deg
pedestals aligned and suppressed |
Fixed, TEST, Wed Mar 6 15:02:51 2019, Valerian, MUST2, Hardware, 3-alpha, Cooling temperature is relevant for the resolution 
|
Using run 52 -> 13deg and run 87 -> -5deg.
We see that the resolution improves at -5 degree. See attached picture as an example for MM2 X. |
Fixed, TEST, Thu Mar 7 09:29:47 2019, Marlene, GRIT, General, , run 96 double alpha source run shifted 60mm   
|
RUN 96
double alpha source
MG1
MG3
MG4
MG5
MG7
-
-
MG11
MM1
MM2
MM3
MM4
Missing strips in Y the same as in run 40
Problem with the annular MG11 -> no current when bias is put... --> to be checked
Problem with the insertion of the target holder --> solved
I also checked again MG9 (still noisy)
and MG10 with 140V I=0,52uA and counting rate is the same order of magnitude as trapezoid. Spectra are OK (not saved). |
Fixed, TEST, Thu Mar 7 14:02:03 2019, Marlène Iulian, MUST2, General, N/A, test of MUST2 electronics
|
Test with pulser at 20 kHz
The OR of MUVI was scaled down by a factor of 100, to provoke some resets |
Fixed, , Tue Mar 12 10:21:17 2019, Marlène, MUST2, General, , Debug Calimero Y
|
Debug of Calimero
test of channels (mate) masking : OK with DAS, OK with GECCO (see attachment) when done in the "disable channels" of GECCO
With calimero, when we are on Y, when we click right to mask a mate we see 'disable mate 2' instead of 'disable mate 10' !!! |
Fixed, TEST, Mon Mar 18 18:31:18 2019, valerian marlène, GRIT, General, 3-alpha, RUN 20 (com2019) 3 alpha overnight 
|
RUN20
Run with double 3alpha source MUST2+MG1_7+MG11
temperature -4 deg on both cooling
Acquisition with VAMOS+MUGAST coupled (com2019)
Time range =600ns
pedestal aligned and suppressed
run start at 18h23 monday 18
run stop at 8h34 tuesday 19
about 12Go of data |
Fixed, , Tue Mar 19 19:35:53 2019, marlene, GRIT, General, , RUN 98 3alpha source all detectors
|
RUN 98
3 alpha source
all detectors (trap,square, MUST2,annular)
Temp=15deg
Acquisition mugast |
Fixed, TEST, Thu Mar 21 10:37:47 2019, Adrien and Valerian, MUST2, General, N/A, Test TOF must2
|
To make sure the mate work correctly we took an alpha run with a delayed fag on the MUVI stop:
- all mate register a time in the the middle of the range as expected (fag delayed by 350ns, range is 600ns)
Test with time calibrator, all channel are enable, pulser on channel 3 of each mate T1X:
- energy spectrum: pulser where we expect it.
- we expect to see a time calibrator spectrum on channel 3 of each mate. instead we see times spectrum on Channel 3 of mate 1 and 2, channel 12 of mate 1, channel 14 of mate2. nothing else
Conclusion
The problem was that the synctst had to be checked and ord unchecked |
Fixed, TEST, Thu Mar 21 13:28:06 2019, Valerian and Adrien, DAQ, Software, N/A, First fully functionnal time calibration run on X and Y of MG1 
|
Our program is able to perform the time calibration of our detector for both X and Y, see picture attached. |
Fixed, TEST, Fri Mar 22 17:28:09 2019, Otto, RUN, General, N/A, TimeCalibratorRun
|
*** Run Time Calibrator FSC ***
- Run: 117
- MUVI: MUVI1
- Side : MUFEE X (Junction)
- Telescope: 1, 2, 3, 4 |
Fixed, TEST, Fri Mar 22 17:37:37 2019, Otto, RUN, General, N/A, TimeCalibratorRun
|
*** Run Time Calibrator FSC ***
- Run: 118
- MUVI: MUVI1
- Side : MUFEE Y (Ohmic)
- Telescope: 1, 2, 3, 4 |
Fixed, TEST, Fri Mar 22 17:47:04 2019, Otto, RUN, General, N/A, TimeCalibratorRun
|
*** Run Time Calibrator FSC ***
- Run: 119
- MUVI: MUVI2
- Side : MUFEE X (Junction)
- Telescope: 1, 2, 3, 4 |
Fixed, TEST, Fri Mar 22 17:56:37 2019, Otto, RUN, General, N/A, TimeCalibratorRun
|
*** Run Time Calibrator FSC ***
- Run: 120
- MUVI: MUVI2
- Side : MUFEE Y (Ohmic)
- Telescope: 1, 2, 3, 4 |
Fixed, TEST, Fri Mar 22 18:06:11 2019, Otto, RUN, General, N/A, TimeCalibratorRun
|
*** Run Time Calibrator FSC ***
- Run: 121
- MUVI: MUVI3
- Side : MUFEE X (Junction)
- Telescope: 1, 2, 3, 4 |
Fixed, TEST, Fri Mar 22 18:15:39 2019, Otto, RUN, General, N/A, TimeCalibratorRun
|
*** Run Time Calibrator FSC ***
- Run: 122
- MUVI: MUVI3
- Side : MUFEE Y (Ohmic)
- Telescope: 1, 2, 3, 4 |
Fixed, TEST, Sat Mar 23 15:26:06 2019, Adrien Matta, OTHER, Software, N/A, To do list
|
FSC:
- Autoconf programme to set all regular parameter (PAC gain, TAC range, ORD, no mask, no pulser)
Sentinel:
- Making the program
- Preparing start script
- Preparing stop script
- Preparing init script
Online/offline:
- Look into ZMQ to replace GRU
- Datum through zmq
- Switch NPSpectraServer/Client to ZMQ and datum
- CsI Calibration with db scan
- 3-alpha calibration using NPCalibration
HV:
- Remote read
- Auto logging
- Alert on trip
- Bt/HV/sector on/off
|
Fixed, TEST, Wed Mar 27 11:06:33 2019, Valerian and Cyril, GRIT, Hardware, 3-alpha, Evolution of resolution with temperature 
|
For the mugast telescope, changing the temperature from 13deg to minus 4deg doesn't seem to have an impact as strong as for the MUST2 telescopes.
Still, the resolution improve with a lower temperature, but the improvement is of only 0.1 channel... (See joined screenshots) |
Fixed, TEST, Thu Mar 28 14:22:25 2019, OttoRun, RUN, General, N/A, TEST
|
Run : 146
Date : 28/03/2019
Start: 14:22:25
asdasdasdasd
Stop: 14:22:42
asdasdasdasd |
Fixed, TEST, Thu Mar 28 15:39:01 2019, Valerian, OFFLINE, Software, N/A, Status of the converion with VAMOS program
|
The conversion with VAMOS program was validated using run_0020 from com2019
Program output as a ref :
T1 : 9978458
T2 : 9978458
checking multiplicities
Reading: 99.9152 %MULTIPLICITIES OK!
checking values
Reading: 99.9152 %%
DETECTOR NUMBERS ARE OK!!!!!
STRIP NUMBERS ARE OK!!!!!
ENERGY VALUES ARE OK!!!!!
TIME VALUES ARE OK!!!!! |
|