Ongoing, e744, Sat Apr 28 13:36:52 2018, Valerian and Iulian, OTHER, Software, N/A, Problem with DAS configuration
|
There is an issue with the GMT slave. When you click Online and then apply write hardware, if the message : register error on GMTSlave appear, reload a functioning DAS config and do not write hardware twice.
If you use write hardware twice, the error will disappear, but almost no triggering of the GMT will occur. |
Ongoing, e744, Thu May 3 08:50:17 2018, François, VACUUM, General, , stop vacuum
|
turbo pumps stopped at 8H45
problem with the cooling system of the M2C chamber, the liquid was in the pipe but it was stopped, no flow, with a lot of "dusts" (vert de gris) => decision = we purge the pipes and the cooling system, once again ! |
Ongoing, e744, Thu May 3 19:11:14 2018, Valerian Marlene and Francois, MUST2, General, 3-alpha, run 3 alpha T5
|
run #196
3 alpha source and pedestals supressed
Trigger T5 only |
Ongoing, e744, Sat May 5 11:14:33 2018, Iulian & Valerian, RUN, General, 3-alpha, run #204 alpha source    
|
run #204
alpha source
start @11h15 05/05
stop @15h16 06/05
Cooling stopped on T5, the cooling system was beeping with a LLL error, I started it again but it stopped with this error again... I stopped the BT and HT on T5.
One of the BT was tripping. I looked at the DAS, but the temperature seemed Ok... but I have no idea if they reflect well the reality...
I join to this entry screenshots :
- the CAEN 1527 terminal
- the das of MUVI2 channel 1 X&Y
- the vigru screen updated
- The LLL error
After calling Francois and Laurent Menager, I refilled it with alcool from the blue containers. It seemed to be working again. |
Ongoing, e744, Sun May 6 17:55:05 2018, Valerian, OTHER, General, 3-alpha, Update on the cooling system problem 6x
|
After waiting for 1-2 hours. I started the BT again on T5 no tripping BT anymore. While writing hardware with DAS T5 responded well.
After starting the HT, i started a new run :
run #206
start @18h02
stop @18h15
the spectrum seem OK.
In both cooling systems the levels are still good, did we refilled the 0 degree cooling system since the beginning?
The vacuum is @ 9.1e-6 in M2C and 2e-5 in 0 degree chamber.
I then left the cooling ON, but stopped both HT and BT on every telescopes.
I join with this entry screenshots of :
- T5 spectra
- BT&HT current before stopping
- DAS window for X&Y |
Ongoing, e744, Sat May 12 20:09:09 2018, iulian, MUST2, General, 3-alpha, Run #115 3 alfa run Calibration T1-T5 trigger   
|
Run #215
Trigger T1-T5
3 alpha run
start @20h09 12/05
stop 11h40 13/05
Run crashed during the night (looks line NARVAL)...
Needed to stop and start to be able to init VME slave.... VME master was ok |
Ongoing, e744, Sun May 13 12:09:55 2018, iulian, MUST2, General, 3-alpha, Run #116 3 alfa run Calibration T1-T5 trigger
|
Run #115
3 alfa run Calibration T1-T5 trigger
start 12h10
start_online gives a ilegal instruction fault from time to time: |
Ongoing, e744, Sun May 13 19:36:09 2018, Valérian + François, MUST2, General, 3-alpha, Run #116 #117 3 alpha run Calibration T1-T5 trigger 
|
run #116
start @12h07 13/05/18
stop @19h45 13/05/18
I refilled the 0 degree cooler.
run #117
start @19h47 13/05/18
stop @ 9H04 14/05/18
Joined is a screenshot of the HT of MUST2
Vacuum in M2C is 5.7e-6 mbar and ~4e-5 in the 0 degree chamber which is higher than before.
Joined spectra. |
Ongoing, e744, Mon May 14 12:57:44 2018, Francois, TARGET, General, , target preparation
|
Cibles Georges
1) Plastique 63 µm
2) 104 µm
3) 200 µm
Cibles GoodFellow
4) Carbone 0.075 mm (je calcule épaisseur de 8,9 mg/cm2)
5) Polyéthylène 63 µm
6) Polyéthylène 0,1 mm = 100 µm
7) 2 cibles de 100 µm en sandwich = 200 µm
|
Ongoing, e744, Tue May 15 09:58:52 2018, Valérian, RUN, General, 3-alpha, run #118 3 alpha
|
run #118
Trigger T1 T2 T3 T4 & T5
EXL + BT not biased but still in trigger
3 alpha
start @18h04 14/05/18
stop @10h00 15/05/18 |
Ongoing, e744, Tue May 15 21:32:46 2018, Iulian Valerian, EXL-PPT, General, 60Co, run #300 60 Co source EXL & PPT trigger
|
Run #300
PPT EXL trigger 60Co
start 21:32:06 15/05/2018 |
Ongoing, e744, Wed May 16 09:49:26 2018, Francois & Ruxandra & Armel, BEAM, Hardware, , E1D6 and E2D6 detectors
|
After struggling with the noise, we achieved ~ 50 keV resolution.
Source = 1 alpha peak 241Am E=5.485 MeV
Detector E1D6 50 µm 25 V in principle, but set to 100 V
Detector E2D6 300 µm 70 V in principle, but set to 100 V
PA gain = 20 mV/MeV
Maximum output signal of the new PA (differential) = 8 V. |
Ongoing, e744, Wed May 16 21:27:55 2018, Iulian Valerian, MUST2, Software, N/A, Run #322 Calimero T1-T4 X strips
|
Run #322
Calimero T1-T4 X strips
1 channel per mate not done (Valerian too slow to cable start stop ) |
Ongoing, e744, Wed May 16 21:45:47 2018, iulian, MUST2, Software, N/A, Run #323 Calimero T1-T4 strips X
|
Run #323
Calimero T1-T4 strips X |
Ongoing, e744, Wed May 16 22:03:13 2018, iulian, EXL-PPT, Software, 60Co, run #324 60Co 
|
run #324
60Co
start 22h02 16/05
stop 10h12 17/05 |
Ongoing, e744, Thu May 17 18:29:16 2018, iulian, MUST2, General, 3-alpha, Run #333 Last alfa run before experiment
|
Run #333
3a source
T1-T5 trigger
start 18h30
ps: If no HT on the detectors but BT on, you will have alfa E&T on X, but not on Y side (except some strips) |
Ongoing, e744, Thu May 17 19:15:21 2018, Iulian , EXL-PPT, General, 60Co, Run #334 Last 60 co run for eficacity before experiment
|
Run #334
start 19h15 |
Ongoing, e744, Sat May 19 15:32:51 2018, Iulian Valerian, EXL-PPT, General, N/A, Started run #346 Room background PPT EXL
|
run #346
Room background PPT EXL
start 15h32 19 Mai
stop 18h52 20 Mai |
Ongoing, e744, Sun May 20 19:11:57 2018, ruxandra cristina giuseppe jaromir, EXL-PPT, Hardware, 60Co, EXL-addback and light leak considerations
|
in the middle of the considerations - pdf file
Content:
Light leak between PM-pair
Zamora theses
Peyre R3B development
Runs 302, 339
There were huge loads, DT not under control, the LaBr and EXL did not coincide.... solved 2018/05/22
Run 347 background - better |
Ongoing, e744, Wed May 23 20:52:01 2018, Iulian Valerian, RUN, General, , run #429 and #430 and config gmt    
|
Changed VAL from 2 us to 2.5 us
run #429 exl ppt triggers
run #430 exl ppt triggers. Changed val on gmtslave also
The correlation between MUST and PPT (run430_E_PPT_vs_T_PPT.pdf) is due to the beta decay of 138La (internal contamination in the LaBr crystal). PPT detects the beta energy with 100% eff, while the gamma rays - emitted in the beta decay process- interacted in MUST detectors. The EXL bidim shows only random events (no internal contamination). |
|