MUST2 SAMURAI_2018 S3-LEB-LPC SUPERNEMO MUGAST EXPAND SCALP GALATRON HiCARI VELO
  MUST2, Page 36 of 48  Not logged in MUST2
Fixed, e755, Wed Jun 27 18:42:09 2018, e755 Daisuke, Olivier, Valérie, RUN, General, Cryo-empty, RUN 159 New input in GMT trigger +scalers Run159ICDEtacatsHf.pngRun159ICDEtacatsHf_Wien100kV74kV.pngRun159Trajectories_Wien100kV74kV.pngRun159_GMTalltriggerINewN12.png
Change of the GMT Trigger:
New entry IN12 corresponding to the CATS2 with no division.
This input is taken from the output of the  bidiv of CATS1 "N" (duplicating the entry CATS2) 
Fixed, e755, Wed Jun 27 19:26:13 2018, e755 Daisuke, Olivier, Pierre, Valérie, RUN, General, Cryo-empty, Run 160 -36Ca Run160CDEtacatsHf_Wien100kV74kV.png
TAC Cats2 HF delay of 30 ns is removed

Run 160 start@ 19h13 stop@ 19h23
Fixed, e755, Wed Jun 27 19:27:52 2018, e755 Daisuke, Olivier, Valérie, RUN, General, Cryo-empty, Run 161 -36Ca Run161CDEtacatsHf_noWienSlitsFH31at8mm.pngRun161_scalers.pngRun161EdeTOFcats.pngRun161TrajectoriesCats.pngRun161mmImpactswithSourcealpha.png

Run 161 start @ 19h25 stop@20h30
e748 Exxx 2411656699 27 juin  20:30 /data/e748X/e755/acquisition/run/run_0161.dat.27-06-18_19h25m55s
Fixed, e755, Wed Jun 27 20:39:44 2018, e755 Daisuke, Olivier, Valérie, RUN, General, Cryo-empty, Run 162-38Ca run162_Trajectories38Ca.pngRun162_ICDE1TcatsHF.png
TUNING OF 38Ca to be ready during the night, after the change of CO source at the machine between 21h ans 2am (maybe). 
LISE team: Omar K, Jean-Charles T.
Tuning made for 38Ca
Fixed, e755, Wed Jun 27 21:13:40 2018, e755 Daisuke, Olivier, edited by Valérie, RUN, General, Cryo-empty, Conditions for the night runs GECOIonizationTrigger.png
TUNING OF 38Ca to be ready during the night, after the change of CO source at the machine between 21h and 2am (maybe). 
LISE team: Omar K, Jean-Charles T. Tuning made for 38Ca at 21h for Run 162. 
 
Fixed, e755, Wed Jun 27 21:25:41 2018, takeshi, shunpei, TARGET, Hardware, Cryo-LH2, temperature log during liquefying temperature2706.png
Here is the temperature log before and during liquefying.
The temperature trend seems almost same as previous.
Fixed, e755, Wed Jun 27 22:11:20 2018, Pierre Louis, OFFLINE, General, Cryo-LH2, Offline analysis of 38Ca(p,d)37Ca 38Ca_pd_128_156.png38Ca_pd_128_156_kinematics.png
Here are some plot summarizing the analysis status on the 38Ca(p,d) channel.

Run concerned: 128-156 (from 25/06 @ 17h11 to 27/06 @ 7h03)
Fixed, e755, Thu Jun 28 00:59:55 2018, e755 Daisuke, Olivier, Pierre, Marlène, Valérie (: edit), RUN, General, Cryo-empty, Run 162-38Ca 8x
 38Ca  Beam at ~ 2. 10**5 pps
F62 +/- 11 mm
SLITS FH31 +/-5mm (moment)
Fixed, e755, Thu Jun 28 01:22:43 2018, Nori, BEAM, General, N/A, Brho2 scan for 36Ca brho2scan_1.pngbrho2scan_2.pngbrho2scan_3.png
We scanned Brho2 values so that the yield for 36Ca is maximized (LISE run0282-0284, F31 = +/-6 mm). 

Attachment 1:
Fixed, e755, Thu Jun 28 01:26:34 2018, daisuke, TARGET, Hardware, Cryo-LH2, Liquid hydrogen target logger 6x
 
Fixed, e755, Thu Jun 28 01:39:58 2018, Nori, BEAM, General, N/A, Discussion for 37Ca run281.pngScreen_Shot_2018-06-27_at_23.16.13.png
Offline analysis of LISE run0281. F31 = +/-0.6 mm, without wedge.
The number of counts of 37Ca was 900/50 = 18 times larger than 36Ca.
Comparing this result with a LISE++ simulation, if the Brho setting is optimized for 37Ca,
Fixed, e755, Thu Jun 28 08:20:54 2018, e755, RUN, General, Cryo-LH2, Summary Run 165-169 run169_tof_cats_hf.png
[U][B]Run 165[/B][/U][LIST]
[*] start: 2h12
[*] start: 3h11
Fixed, e755, Thu Jun 28 08:29:08 2018, Louis, CATS, General, Cryo-LH2, CATS-HF time shift during the night  6x
noticed that the time between CATS and HF shifted during the night.
run 164 to 169
Fixed, e755, Thu Jun 28 08:34:30 2018, Fredd, Louis, Daisuke, RUN, General, Cryo-LH2, Run 170 Run170_TCATSHF.pngscreenshot_2018-06-28_08h15m27s.pngRun170_Target.pngRun170_CATSRAWt.pngRun171_M2Energy.png
[U][B]Run 170[/B][/U][LIST]
[*] start: 8h07
[*] start: 
Fixed, e755, Thu Jun 28 10:38:58 2018, Freddy, MUST2, General, N/A, T4 Comparison of calibration runs Comparison_T4X_calibbeforeexp.pngComparison_T4Y_calibbeforeexp.png
Attached is a comparison of two calibrations performed before the experiment (2 weeks and one day before) for Telescope 4 (the one having a degraded resolution
in Ex on the offline). 
One can see that:[LIST]
Fixed, e755, Thu Jun 28 11:08:54 2018, Freddy, Louis, Valerian, RUN, General, 3-alpha, Intermediate alpha calibration T1234 Run171_M2_EX_RAW.pngRun171_M2_EY_RAW.png
Run 171

3alpha source in front of T1234
Fixed, e755, Thu Jun 28 13:53:28 2018, Freddy, Louis, Valerian, RUN, General, 3-alpha, Pedestal run + Alpha calibration with T4 at 80V 
[U][B]Run 172[/B][/U][LIST]
[*] Pedestal run on T1234
[/LIST]
Fixed, e755, Thu Jun 28 19:58:12 2018, shumpei, OTHER, General, N/A, Kinematics for the reactions kinematics.pdf
Kinematics for the reaction of E755 and E738 experiments are shown.
Fixed, e755, Fri Jun 29 00:59:15 2018, Louis, OFFLINE, General, Cryo-LH2, Analysis of run 63 to 89 in 40Ca(p,t)38ca reaction Chek_cuts_40Capt.pngKinematics_40Ca.pngTelescope_Ex_40Capt.pngKinematics_38Capt_withoutCutZero.png
Here are some plot summarizing the analysis status on the [B]40Ca(p,t)38Ca[/B] channel.

Run concerned: 63-89 
Fixed, e755, Fri Jun 29 07:04:35 2018, takeshi, TARGET, Hardware, Cryo-LH2, target temperature temperature2906.png
 

ELOG Home Page