Fixede744 Sun May 27 20:47:02 2018 e744- ValérieDAQHardwareN/AInfo to reboot the crates in case of problem
In case of problems in the run control, if it is not possible to reinstall the crates in the "Ready" mode status,
it is possible to reboot them remotely via the software commands.
this can be done using the iolan windows.
first, open a Terminal, then write:
iolan must2 all
Two windows are opened, for each of the VXI crates. see snapshot IOLANmust2reboot.png
then it is possible to reboot the crates by writing in each of the gansterm terminals the "reboot" command.
(Note that a password is asked, it corresponds to the first letter of all the words between (La cigale ...l'été) in the famous sentence of La Fontaine's fable "La Cigale et la Fourmi" ("The Grasshopper and the Ant").
Then after the operation the run Control Narval should be ready (see snapshot).
If not, it means that we need to enter in the D6 room to reboot the crates directly by pushing the "SYS RES" button (using the tiny yellow screw) on the two crates:
start with the Master crate (ganlx1, the one with the main GMT and MUVI1), then press the button of the second crate (ganlx14, with the GMTslave and the second MUVI).
The click-click on each crate means that the reset is done.
(NB: Simultaneously, the two gansterm terminals show the lines of the on-going reboot operations).
Attachment 1: IOLANmust2reboot.png
IOLANmust2reboot.png
Attachment 2: RunControlE744Ready.png
RunControlE744Ready.png
Fixede744 Mon May 28 11:00:07 2018 Valerian and Iulian and PhilRUNGeneral two protons
Attachment 1: e2p_15O.pdf
e2p_15O.pdf
Fixede744 Mon May 28 12:22:42 2018 Francois & MarleteOFFLINEGeneral superposition exp / theory for 15O and 15F
Attachment 1: sum.jpg
sum.jpg
Attachment 2: 15F_final.jpg
15F_final.jpg
Fixede744 Mon May 28 16:32:38 2018 E744- ValérieDAQGeneralN/ADAS configuration files-References
Attachment 1: ConfigGMTexp744Mon28th.png
ConfigGMTexp744Mon28th.png
Attachment 2: ConfigMUVICastelStandardA.png
ConfigMUVICastelStandardA.png
Attachment 3: ConfigMUVICastelStandardB.png
ConfigMUVICastelStandardB.png
Attachment 4: MM5_thresholdAt992keV.png
MM5_thresholdAt992keV.png
Attachment 5: MM1_thresholdAt1MeV.png
MM1_thresholdAt1MeV.png
Attachment 6: ConfigE744actionGanlx14b.png
ConfigE744actionGanlx14b.png
Attachment 7: ConfigE744actionGanlx1b.png
ConfigE744actionGanlx1b.png
Attachment 8: ConfigE744InterfaceU3M.png
ConfigE744InterfaceU3M.png
Attachment 9: ConfigE744paramU2M.png
ConfigE744paramU2M.png
Attachment 10: ConfigE774CentrumMaster.png
ConfigE774CentrumMaster.png
Attachment 11: ConfigMUVICastelMufeeYStd.png
ConfigMUVICastelMufeeYStd.png
Attachment 12: ConfigMUVICastelMufeeXE744.png
ConfigMUVICastelMufeeXE744.png
Attachment 13: ConfigE744Muvi1B.png
ConfigE744Muvi1B.png
Attachment 14: ConfigE744Muvi1A.png
ConfigE744Muvi1A.png
Attachment 15: MM1MufeeYtemp5deg.png
MM1MufeeYtemp5deg.png
Fixede744 Mon May 28 18:27:45 2018 E744- ValérieDAQGeneralN/AHigh Voltages and intensities on MUST2
Check regularly the HT on the MUST2.
NB: without beam the current on Telescope 4 is high, between 9 and 11 µA. see snapshot.
NB: The Ioset was increased at 20 µA on Friday 25th (cf Id entry=490) to avoid trips on this telescope due to strong intensity fluctuations due to the beam.
Attachment 1: HT_MUST2withoutBeam28may18.png
HT_MUST2withoutBeam28may18.png
Fixede744 Mon May 28 20:33:39 2018 E744- evening shift LISE+e744 teams (edit Iulan, Valérie)RUNGeneralCH2BEAM AGAIN RUN 2100 Tuning
See plot of the Must2 impacts, Wien filter set at +/-0.8kV
Beam on CATS 1.2 10**5 pps
CH2 183 µm
Div as before
Attachment 1: beam_spot_2100_end.png
beam_spot_2100_end.png
Fixede744 Mon May 28 20:38:21 2018 E744- evening shift LISE+MUST2 teams (edit Valérie)RUNGeneralCH2 RUN 2101 DATA target 4
run #2101
start @20h27
stop @22h20
target 4

Evening shift team:
LISE and E744 François, Iulan, Valérian, Louis, Jean-Charles, Marlete A., Pierre D., Simon G., Valérie L.
E744
Beam on CATS 1.2 10**5 pps
CH2 183 µm // ERROR ?? this should be 100um
Div as before
All Triggers in GMT (without LISE)
Attachment 1: ScalersDuringRun2101.png
ScalersDuringRun2101.png
Attachment 2: HV_EXL_28May18.png
HV_EXL_28May18.png
Attachment 3: TACduringRun2101.png
TACduringRun2101.png
Attachment 4: TMM5stripsXYETrun2101.png
TMM5stripsXYETrun2101.png
Attachment 5: MM1toMM4strYE_run2101.png
MM1toMM4strYE_run2101.png
Attachment 6: MM1toMM4strXT_run2101.png
MM1toMM4strXT_run2101.png
Attachment 7: MM1toMM4strYT_run2101.png
MM1toMM4strYT_run2101.png
Attachment 8: MM1toMM4impactsMM5_Run2101.png
MM1toMM4impactsMM5_Run2101.png
Attachment 9: TACcoincMMppt_Run2101.png
TACcoincMMppt_Run2101.png
Attachment 10: HV_MUST2duringRun2101.png
HV_MUST2duringRun2101.png
Attachment 11: EXLCsiPads_Run2101.png
EXLCsiPads_Run2101.png
Attachment 12: Scaler_end_Run2101.png
Scaler_end_Run2101.png
Fixede744 Mon May 28 22:11:52 2018 e748- LouisEXL-PPTHardwareCH2EXL4 trigger excess
During run 2101, Frequency of the EXL4 channel at 478Hz compared to values around 30Hz for other channels
Attachment 1: Scaler_EXLTriggerExeed_Run2101.png
Scaler_EXLTriggerExeed_Run2101.png
Fixede744 Mon May 28 22:27:14 2018 Simon et LouisRUNGeneralCH2RUN 2102 DATA target 4
run #2102
start @22h20
stop @23h30
target 4

Evening shift team:
LISE and E744 François, Iulan, Valérian, Louis, Jean-Charles, Marlete A., Pierre D., Simon G., Valérie L.
E744
Beam on CATS 1.3 10**5 pps
CH2 183 µm // ERROR THIS SHOULD BE 100um
Div as before
All Triggers in GMT (without LISE)
Attachment 1: Scaler_start_Run2102.png
Scaler_start_Run2102.png
Attachment 2: Scaler_stop_Run2102.png
Scaler_stop_Run2102.png
Fixede744 Mon May 28 23:52:19 2018 Simon and Louis (start), Franck (stop)RUNGeneralCarbonRUN 2103 DATA target 1 Carbon
run #2103
start @23h49
stop @1h51
target 1 Carbon

Evening shift team:
LISE and E744 François, Iulan, Valérian, Louis, Jean-Charles, Marlete A., Pierre D., Simon G., Valérie L.
E744
Beam on CATS 1.3 10**5 pps
Carbon 75um
Div as before
All Triggers in GMT (without LISE)
Attachment 1: Scaler_start_Run2103.png
Scaler_start_Run2103.png
Attachment 2: Scaler_stop_Run2103.png
Scaler_stop_Run2103.png
Fixede744 Tue May 29 01:08:22 2018 e748BEAMGeneralCarbonBeam intensity
At 0:46 primary beam intensity reaches 5 uA -> 1.5e5 pps on CATS.
Fixede744 Tue May 29 02:01:58 2018 Franck, Valerian, PhilRUNGeneralCarbonRun 2104 - Target 1 Carbon
Run 2104
Beam: 14O
Start @ 2:00 29 May 2018
Stop @ 4:01 29 May 2018

Target 1 Carbon
Franck, Phil, Valerian

Beam rate (CATS): 1.4e5 pps
Attachment 1: Scaler_start_Run2104.png
Scaler_start_Run2104.png
Attachment 2: Scaler_stop_Run2104.png
Scaler_stop_Run2104.png
Fixede744 Tue May 29 02:38:21 2018 Franck, Valerian, PhilONLINEGeneralCarbonSpectra and HV Start Run 2104
Attachment 1: GATCONF_stop_run2103.png
GATCONF_stop_run2103.png
Attachment 2: MM5_E_T_start_run2104.png
MM5_E_T_start_run2104.png
Attachment 3: MM14_EX_start_run2104.png
MM14_EX_start_run2104.png
Attachment 4: MM14_EY_start_run2104.png
MM14_EY_start_run2104.png
Attachment 5: MM14_TX_start_run2104.png
MM14_TX_start_run2104.png
Attachment 6: MM14_TY_start_run2104.png
MM14_TY_start_run2104.png
Attachment 7: MM_Impact_start_run2104.png
MM_Impact_start_run2104.png
Attachment 8: TAC_start_run2104.png
TAC_start_run2104.png
Attachment 9: EXL17_start_run2104.png
EXL17_start_run2104.png
Attachment 10: EXL_start_run2104.png
EXL_start_run2104.png
Attachment 11: hv_run2104.png
hv_run2104.png
Fixede744 Tue May 29 04:08:52 2018 Franck, Valerian, PhilRUNGeneralCarbonRun 2105 - Target 1 Carbon
Run 2105

Beam 14O

Start 4:06 29 May 2018
Stop 6:06 29 May 2018

Target 1 Carbon

Franck, Valerian, Phil
Attachment 1: Scaler_start_Run2105.png
Scaler_start_Run2105.png
Attachment 2: Scaler_stop_Run2105.png
Scaler_stop_Run2105.png
Fixede744 Tue May 29 10:42:00 2018 FrancoisBEAMGeneral effective beam time
In total, there were:

1.4 UT of 14O, average 2x10^5 pps
0.7 UT of 14N, calibration
0.7 UT of background subtraction (carbon)


+ plot of the beam current during the last day.
Attachment 1: os1.jpeg
os1.jpeg
Fixede744 Tue May 29 12:06:05 2018 iulian maurycyOFFLINEGeneralCH2Carbon substraction
The scale factor for Carbon subtraction is 1.224. This means: RealCountsHidrogen=Counts CH2 - 1.224 * CountsCarbon

runs considered for the CH2 target

/home/e748/analysis/nptool/Projects/e744/conversion/rootdir/run_2013_0.root
/home/e748/analysis/nptool/Projects/e744/conversion/rootdir/run_2014_0.root
/home/e748/analysis/nptool/Projects/e744/conversion/rootdir/run_2015_0.root
/home/e748/analysis/nptool/Projects/e744/conversion/rootdir/run_2016_0.root
/home/e748/analysis/nptool/Projects/e744/conversion/rootdir/run_2017_0.root
/home/e748/analysis/nptool/Projects/e744/conversion/rootdir/run_2018_0.root
after the long interruption
/home/e748/analysis/nptool/Projects/e744/conversion/rootdir/run_2101_0.root
/home/e748/analysis/nptool/Projects/e744/conversion/rootdir/run_2102_0.root

run 2100 was not considered

runs considered for the Carbon subtraction:
after the long interruption
/home/e748/analysis/nptool/Projects/e744/conversion/rootdir/run_2103_0.root
/home/e748/analysis/nptool/Projects/e744/conversion/rootdir/run_2104_0.root
/home/e748/analysis/nptool/Projects/e744/conversion/rootdir/run_2105_0.root
the rest of runs was not considered
Attachment 1: Carbon_runs_scale_factor.pdf
Carbon_runs_scale_factor.pdf
Fixede744 Tue May 29 17:14:41 2018 François, Freddy, ValérieBEAMGeneral Beam back in D6
At 17pm Tuesday 29th we have beam coming back in D6. Run (without storage)
NB: The current on T4 (with Hv set 60V) is fluctuating between 4 and 6.5 µA.
Attachment 1: HV_MUST2_29mayAt17h20.png
HV_MUST2_29mayAt17h20.png
Attachment 2: HV_EXL_29mayAt17h21.png
HV_EXL_29mayAt17h21.png
Fixede744 Tue May 29 19:03:38 2018 Valérie (edit)RUNGeneralCH2Run #2112 BEAM BACK
run #2112
Beam back given by the machine.
Beam+ Lise team: Omar K and Pierre Delahaye, Jean-Charles T.
Evening shift team : Valérian, François, Iulan, Valérie
start @ 20h00
stop @ 21h35
Beam intensity from 8. 10**4 pps to around 10**5 pps
target n°4. CH2 104 µm
All triggers, (no LISE)
Divisions CATS1 3. 10**4. PPT 3000 ; EXL 10**4
cf current of T4 to be checked regularly. At present with the beam the current is around 10.5 µA (fluctuates between 9 and 11 µA) for HV set at 60 V.
Beam rate is reduced at the end of the run, around 4000-5000 pps.
The machine operators are trying to recover the initial rate.
Next run (2113) will be started in the low rate conditions.
Attachment 1: Scaler_start_Run2112.png
Scaler_start_Run2112.png
Attachment 2: HV_MUST2Run2112_May29Beam.png
HV_MUST2Run2112_May29Beam.png
Attachment 3: Run2112_TriggerConf.png
Run2112_TriggerConf.png
Attachment 4: Run2112_CorrelEXL17.png
Run2112_CorrelEXL17.png
Attachment 5: Run2112_RefTacTiming.png
Run2112_RefTacTiming.png
Attachment 6: Run2112_CSIExl.png
Run2112_CSIExl.png
Attachment 7: Run2112_MMStrXT.png
Run2112_MMStrXT.png
Attachment 8: Run2112_MMStrYT.png
Run2112_MMStrYT.png
Attachment 9: Run2112_MM1to4strxE.png
Run2112_MM1to4strxE.png
Attachment 10: Run2112_MM1to4strYE.png
Run2112_MM1to4strYE.png
Attachment 11: Run2112_MMEtof.png
Run2112_MMEtof.png
Attachment 12: Run2112_MM5strxyET.png
Run2112_MM5strxyET.png
Attachment 13: Run2112_MMImpacts.png
Run2112_MMImpacts.png
Attachment 14: Scalers_endofRun2112_.png
Scalers_endofRun2112_.png
Fixede744 Tue May 29 21:41:55 2018 ValérieRUNGeneralCH2Run #2113
RUN #2113 start @ 21h37; stop 0h14 @
target n°4. CH2 104 µm
All triggers, (no LISE)
Divisions CATS1 3. 10**4. PPT 3000 ; EXL 10**4

Evening shift team: Valérian (offline); Valérie (Online).
with Olivier, Jean-Eric and Marlete.

Between 21h37 and 22h. Beam intensity from 4000 pps increasing around 7. 10**4 pps then down to 800 pps, fluctuating fastly.
Machine operators are trying to compensate the fluctuations.

cf current of T4 around 9.4 µA (fluctuates between 9 and 10 µA) for HV set at 60 V. Strong increase around 13 µA during a few minutes.
cf HV_MUST2run2113_29Mayat21h50.png
Between 23h10 and 23h20 the beam rate was evolving from 80-88k to 90-100 k and the current was fluctuating in T4 from 8.8 to 9.9 µA.
Beam rate is reduced at the beginning of the run, around 4000-5000 pps. See Scalers_Run2113initAt21h39.png
Then around 60k pps at 21h46; at 77k pps at 21h52, at 98k pps at 22h06 but very unstable and then down to 30kcps.
Around 110k pps at 22h35. cf ScalersRun2113_110kAt22h35.png
Stabilization around 88k and 100k pps between 22h50 and 23h05 (hoping we will have the beam rate around these values during the night)
------------------------------------------------------------------------------------------------------------------------------------------
CHECKING THE MISSING STRIPS X and Y IN THE TELESCOPES:

XE || MM1: X44 || MM2: X3, X4, X5, X6, X31 || MM3: all X OK || MM4: X8, X9, X45, X128 || MM5: XE all OK

YE || MM1: Y25, Y123, Y124 || MM2: Y100, Y128 || MM3: all Y OK || MM4: Y29, Y62, Y123, Y126 || MM5: Y15, Y39, Y98
------------------------------------------------------------------------------------------------------------------------------------------
Attachment 1: Scalers_Run2113initAt21h39.png
Scalers_Run2113initAt21h39.png
Attachment 2: HV_MUST2run2113_29Mayat21h50.png
HV_MUST2run2113_29Mayat21h50.png
Attachment 3: ScalersRun2113_110kAt22h35.png
ScalersRun2113_110kAt22h35.png
Attachment 4: Run2113_MMimpacts.png
Run2113_MMimpacts.png
Attachment 5: Run2113_MMimpactsAt23h07.png
Run2113_MMimpactsAt23h07.png
Attachment 6: Run2113_CsIExLCorrPpt_ETfag.png
Run2113_CsIExLCorrPpt_ETfag.png
Attachment 7: Run2113_TAC.png
Run2113_TAC.png
Attachment 8: Run2113_refTimingFAG_PPT.png
Run2113_refTimingFAG_PPT.png
Attachment 9: Run2113endRunScalers.png
Run2113endRunScalers.png
Fixede744 Wed May 30 00:17:02 2018 Valérie, LouisRUNGeneralCH2Run #2114
RUN #2114 30 mai 2018 start @ 0h15; stop @ 2h58
BEAM STOP DUE to the shut down of the deviation element at the entrance of our D6 area.
target n°4. CH2 104 µm
All triggers, (no LISE)
Divisions CATS1 3. 10**4. PPT 3000 ; EXL 10**4

Evening shift team: Louis Valérie (Online)

Beam intensity around 10**5 pps decreasing to 80-70k pps around 1h30 then coming again to 95k pps at 1h40
Between 2h48 and 2h50 beam was decresaing down to few 1000/s on CATS, due to some alarms on the beam line, slowly increasing again after 2h52.
cf current of T4 around 13-14 µA Strong increase around 13 µA (due to the stabilization of the beam rate at 10**5 pps !)

------------------------------------------------------------------------------------------------------------------------------------------
NB: The E_TOF plots for MM1 and MM3 seem to count less than the MM2 and MM4 plots, nearly factor 10 below for MM1, and factor 5 below for MM3.
But the raw spectra for StrXT of MM1 and MM3 have quite the same statistics (see integral values) maybe some software problems.
Check how the TOF parameter is done in the offline (from XT or YT +thresholds and pattern conditions).
The same behaviour was seen in the previous runs.
Attachment 1: Run2114_initScalers.png
Run2114_initScalers.png
Attachment 2: Run2114_MMimpactAT1h42.png
Run2114_MMimpactAT1h42.png
Attachment 3: Run2114_EXLCsIcorrelPPT_QTfag.png
Run2114_EXLCsIcorrelPPT_QTfag.png
Attachment 4: Run2114_TimingRefFAGppt.png
Run2114_TimingRefFAGppt.png
Attachment 5: Run2114_MMStrXT.png
Run2114_MMStrXT.png
Attachment 6: Run2114_MMStrYT.png
Run2114_MMStrYT.png
Attachment 7: Run2114_ETOFmm1toMM4.png
Run2114_ETOFmm1toMM4.png
Attachment 8: Run2114_scalersEndRun.png
Run2114_scalersEndRun.png

ELOG Home Page