  MUST2, Page 22 of 48  Not logged in MUST2
Fixed, e744, Wed May 23 15:42:04 2018, Louis, Valérie, MUST2, General, N/A, CALIMERO run 409 - XT - T1 to T4 GecoCalimeroMuviTel4Thr1MeV.pngconfigCalim1.pngconfigCalimOKexterne.pngGecoCalimeroMuviGMT.pngHTtelescopesMustsWed23May.png
Started run #409 
GMT triggers: GecoCalimeroMuviGMT.png 
HT on cf : HTtelescopesMustsWed23May.png
Pinned, e744, Wed May 23 17:23:34 2018, Freddy, MUST2, General, , Pedestals and alpha calibration analysis Plot_DiffPedestals.png
Calibration coefficients for MUST2 telescopes were extracted from run_0118 (acquired during night from 13th to 14th of May). They are now located in the
folder:
Fixed, e744, Wed May 23 18:20:59 2018, e744, MUST2, General, N/A, Test Calimero Run 425 
Started run #425 Calimero  NEW XT  T1toT4
ampl Pulser 12MEV; thr for T4 1 MeV
problem on data taking
Ongoing, e744, Wed May 23 20:52:01 2018, Iulian Valerian, RUN, General, , run #429 and #430 and config gmt config_gmt.pngconfig_gmtslave.pngrun430_E_PPT_vs_T_PPT.pdfrun430_E_PPT_proj.pdfrun430_E_EXL_vs_T_EXLor.pdf
Changed VAL from 2 us to 2.5 us

run #429 exl ppt triggers
Fixed, e744, Wed May 23 23:37:14 2018, Valérie L., MUST2, General, N/A, MUVI configuration DAS 13x
Configurations files of the MUVI 1 MufeeX and Y.
On MufeeX and Y configuration:
Note that the thresholds on Must2 T1 to T3 is at 400 keV on May 23th Midnight (same as before); and for T4, now it is set at 1 MeV (not 400 keV).
Fixed, e744, Thu May 24 01:02:19 2018, Valerian, OTHER, General, N/A, run #431 ED4_TD4_23-05-18_00-58.png
[U][B]run #431[/B][/U]
Trigger LISE
Beam in D4
Fixed, e744, Thu May 24 01:10:30 2018, iuliqn, RUN, General, , run 433 Lise trigger 
Should be ql foil in front of the si detector....
Fixed, e744, Thu May 24 01:11:26 2018, Iulian Valerian, RUN, General, N/A, run 434 Lise trigger ED4_TCATSHF_23-05-18_1-18.pngED4_TCATSHF_23-05-18_1-18_efficiency.png
Cats inserted

efficiency is around ~99%
Fixed, e744, Thu May 24 01:53:28 2018, iulian, RUN, General, N/A, run 438 Lise trigger  run_439_d6_cats_hf.pngrun_439_transmisiond4_d6.png
run 438  D4 in
run 439 d6 in.
Ongoing, e744, Thu May 24 02:30:52 2018, iulian, RUN, General, N/A, RUN 440 14N no target trigger Must & cats %100 run440.png
RUN 440 
14N beam  \
no target 
Fixed, e744, Thu May 24 03:21:37 2018, iulian, OTHER, Hardware, N/A, Position measurements Must2/PPT/EXL STP-2018-E054_E744_I-Stefan_J-Mrazek_LISE-D6.pdf
 
Fixed, e744, Thu May 24 03:57:34 2018, iulian, RUN, General, N/A, run 442 Lise trigger d6 cats_e1_d6_t1_D6_run442.png
 
Fixed, e744, Thu May 24 04:20:34 2018, iulian, RUN, General, N/A, run 443 T1-t5 triggers mm5_run443.pngmm5_2_run443.pngmm5_3_run443.pngmm5_4_run443.png
run 443
T1-T5 triggers
Pinned, e744, Thu May 24 05:44:56 2018, iulian, RUN, General, N/A, Important::analysis of the run 443/ things to do t_mm_PPT_run443.pdft_mmhf_run443.pdft_mm_exlor_run443.pdfcorrelation_run443.pdf
[I][B]No stop on t5, but TAC MM_CATS ok.. So two possibilities: 
1) Stop Cable not connected on Muvi2 
2) Problem with the validation of CATS by FAG
Ongoing, e744, Thu May 24 05:59:44 2018, iulian, MUST2, General, N/A, run 444 t1-t4 trigger no target 14n beam mm5_8_run445.pngmm5_7_run444.pngmm5_6_run444.pngmm5_5_run444.pngmm5_4_run444.png
run 444 
t1-t4 trigger
 no target 
Ongoing, e744, Thu May 24 06:30:27 2018, iulian, RUN, General, N/A, run 445 t1-t4 trigger no target 14n beam no CATS mm5_run445_3.pngmm5_run445_2.pngmm5_run445_1.png
 
Pending, e744, Thu May 24 06:53:12 2018, e748, RUN, General, N/A, run #446 CATS trigger 
 
Fixed, e744, Thu May 24 12:01:54 2018, Valérie for Calimero team - Valérian, Fairouz, MUST2, General, , Bug server Calimero Run #447-449 12x
Calimero on ganp161
Telscopes T1 to T4 thresholds for T1 to T3 400 keV ; T4 : 1 MeV
ampli pulser 12 MeV 
Fixed, e744, Thu May 24 17:18:58 2018, Valérie for Calimero team : Valérian, Louis, MUST2, General, N/A, CALIMERO Tests Runs 451 to 452 (done in D6)  configCalimeroRun452YTthr1MeV.pngPlotCalimrun452YTthr1MeVmaybe.pngPlotCalimrun453YT5thr1MeVtrue.png
Test runs for telescopes T1 to t4 
Nb: The applied threshold is now 1 MeV but it seems to be not the case when we look at the spectra.
Maybe a problem of the read configuration in GECO.
Fixed, e744, Thu May 24 17:23:57 2018, Valérie for Calimero team: Valérian, Louis, MUST2, General, N/A, CALIMERO Runs 453-457 OK 16x
Calimero on ganp1074 in D6
Time Calibrator Range: 640 ns; Period 20 ns Amplitude of pulser (test generator) 9MeV  
Run 453 Telescope T5 (MUVI2-slave) XT see plot