e744
Mon Mar 26 11:46:43 2018
e744 : Valerian
RUN
General
3-alpha
Tests runs Ganacq log
(15:51:33 - 19/03/2018) INFO - rcc_gui - Started
run #1
Fixed
e744
Mon Mar 26 14:20:22 2018
e744 : Valerian
MUST2
Hardware
3-alpha
Bidimensional graphs for Telescope 7 and 6
WARNING T5 == T7
[U][B]
EDIT 27/03/18 : WARNING X and Y are inverted,
Ongoing
e744
Mon Mar 26 15:07:06 2018
e744 : Valerian et Louis
MUST2
Hardware
3-alpha
Energy vs Strip for T6 et T7
Weird signal on StripX of T6... might be the
copper oxyde projections making a short-circuit
Ongoing
TEST
Tue Mar 27 10:47:39 2018
e744 : Valerian
MUST2
Hardware
3-alpha
Choice of DSSSDs
Ongoing
e744
Tue Mar 27 11:11:04 2018
e744 : Valerian
MUST2
Hardware
3-alpha
Choice of DSSSDs
Different plots of Strip channel vs Strip
number for X and Y in order to make our choice
14x
Fixed
e744
Tue Mar 27 16:26:29 2018
e744 : Valerian
MUST2
General
3-alpha
Bidim for T1 T3 T4 T5 T6 T7 T8
7x
Ongoing
e744
Tue Mar 27 17:22:24 2018
e744 : Valerian
MUST2
Hardware
3-alpha
Choosing the DSSSDs
We can see that the DSSSDs on T1(CsI) T3(CsI)
T4(CsI) and T5(SiLi) are in good shape (cf
:[URL=https://elog.lpc-caen.in2p3.fr/MUST2/333]Bidim
Ongoing
e744
Wed Mar 28 13:21:32 2018
e744 : Valerian
MUST2
Hardware
3-alpha
Choosing the DSSSDs
[quote="e744 : Valerian"]We can see that the
DSSSDs on T1(CsI) T3(CsI) T4(CsI) and T5(SiLi)
are in good shape (cf :[URL=https://elog.lpc-caen.in2p3.fr/MUST2/333]Bidim
Ongoing
e744
Wed Mar 28 16:35:01 2018
e744 : Valerian
MUST2
Hardware
3-alpha
Choosing the DSSSDs
[quote="e744 : Valerian"][quote="e744 : Valerian"]We
can see that the DSSSDs on T1(CsI) T3(CsI)
T4(CsI) and T5(SiLi) are in good shape (cf
Fixed
e744
Tue Apr 3 10:44:38 2018
e744 : Valérian
MUST2
Hardware
Update on Must2 telescopes
For the next day, the plan is to check the
DSSD's connections of T6 & T7 followed by
an alpha run, if the problem seen on T6 are
Ongoing
e744
Tue Apr 3 15:30:49 2018
e744 : Valérian
MUST2
Hardware
Cabling of T6 & T7
After checking the cable of T6 & T7 it seems
that there were in fact an inversion during
experiment e748. T6 is the bottom one, and
Ongoing
e744
Wed Apr 4 17:49:05 2018
e744 : Valérian
EXL-PPT
Hardware
Update on EXL
The EXL detector has been mounted, it is very
close to the target ~4cm and doesn't do any
shadow on the M2 telescopes. But it isn't
6x
Fixed
e744
Tue Apr 10 17:43:28 2018
Adrien Matta and FyFy
MUST2
Hardware
N/A
login to CAEN SY1527 HV/BT mainframe
To control the CAEN SY1527 HV/BT mainframe
use the following command from a terminal:
Fixed
e744
Tue Apr 17 09:07:55 2018
Adrien Matta
DAQ
General
N/A
DAQ issue summary
Previously on e744:
After a chat with Charles Houarner we decided
Fixed
e744
Tue Apr 17 09:18:00 2018
Cherry MX team
MUST2
Hardware
N/A
T5 is back and running strong
T5 telescope appears to be fully functional
again. It shows both Energy and Time with
excellent resolution.
Ongoing
e744
Tue Apr 17 17:36:37 2018
Cherry Mx Team
MUST2
Software
N/A
GRU SUCKS
Pretty much today's summary in the title.
[URL=https://i.pinimg.com/originals/a8/d4/12/a8d41206e8bd9c189397fb4907656981.jpg]https://i.pinimg.com/originals/a8/d4/12/a8d41206e8bd9c189397fb4907656981.jpg[/URL]
Fixed
e744
Mon Apr 23 11:33:53 2018
e744 Valerian
OTHER
Hardware
N/A
Inspection signals
Inspection signals between D6 and LISE Acquisition
room are connected as follow :
Pending
e744
Tue Apr 24 14:18:22 2018
Valerian Freddy and Adrien aka Cherry Mx Team
MUST2
Hardware
N/A
Current telescope-pcb layout
Telescope 1 : PCB 5 (ref on pcb: 2274)
Telescope 2 : PCB 4
Telescope 3 : PCB 7
Fixed
e744
Tue Apr 24 15:42:03 2018
e744 Valérie L.
DAQ
General
GMT chronogramme
Crate ganlx1 GMT master FAG 100ns ; VAL 2
µs ; CT 6 µs
Crate ganlx14 GMT slave FAG 100ns ; VAL 2
Fixed
e744
Tue Apr 24 15:51:04 2018
e744 Valérie L.
MUST2
General
MUST2 configuration /parameters
TAC range for all telescopes: 600ns
Thresholds: 402 keV
Goto page