Fixed, e748, Mon Jul 10 00:35:29 2017, e748, RUN, General, CD2, Run 380
|
Started at 0:02
18O 4.3 uAe, fluctuating
|
Fixed, e748, Mon Jul 10 01:34:12 2017, e748, RUN, General, CD2, Run 380 (file change)
|
Data file change at 1:18 -> run_0380.dat.10-07-17_00h02m00s.1
18O 4.5 uAe
|
Fixed, e748, Mon Jul 10 02:04:33 2017, e748, CATS, General, CD2, CATS raw strips and trajectories 
|
|
Fixed, e748, Mon Jul 10 02:47:27 2017, e748, RUN, General, CD2, Run 380 (file change)
|
2:26 data file change -> run_0380.dat.10-07-17_00h02m00s.2
18O 4.5 uAe
|
Fixed, e748, Mon Jul 10 03:34:24 2017, e748, RUN, General, CD2, Run 380 (file change)
|
3:33 data file change -> run_0380.dat.10-07-17_00h02m00s.3
18O 4.5 uAe
|
Fixed, e748, Mon Jul 10 03:45:19 2017, e748, MUST2, General, CD2, SiLi 1/T5 triped
|
Triped between 3:34 and 3:44.
We turn it back on at 3:46 (370 V) -> 22.5 uA |
Fixed, e748, Mon Jul 10 04:33:32 2017, e748, CATS, General, CD2, CATS: raw strips, trajectories and pos on target  
|
|
Fixed, e748, Mon Jul 10 04:46:11 2017, e748, RUN, General, CD2, Run 380 (file change)
|
4:42 data file change -> run_0380.dat.10-07-17_00h02m00s.4
18O 4.4 uAe
|
Fixed, e748, Mon Jul 10 05:47:40 2017, e748, RUN, General, CD2, Run 380 (file change)
|
5:46 data file change -> run_0380.dat.10-07-17_00h02m00s.5
18O 4.5 uAe
|
Fixed, e748, Mon Jul 10 06:53:40 2017, e748, MUST2, General, CD2, SiLi 1/T5 triped
|
Triped at ~ 6:50.
We turn it back on at 370 V -> I = 18 uA but increases rapidly to 21 uA |
Fixed, e748, Mon Jul 10 06:55:58 2017, e748, RUN, General, CD2, Run 380 (file change)
|
6:48 data file change -> run_0380.dat.10-07-17_00h02m00s.6
18O 4.5 uAe
|
Fixed, e748, Mon Jul 10 08:19:45 2017, e748, RUN, General, CD2, End run 380
|
We stop run 380 to enter D6 and select mask target for CATS reference data. |
Fixed, e748, Mon Jul 10 08:37:23 2017, e748, RUN, General, N/A, Run 381 mask target
|
Trigger = Plastic, div=1
Primary intensity = 1 uAe
CATS rate = 35 kcps
|
Fixed, e748, Mon Jul 10 10:06:27 2017, e748, RUN, General, N/A, end of experiment
|
10h06 we stop the experiment. |
Fixed, e748, Mon Jul 10 17:43:37 2017, Adrien, MUST2, General, N/A, Calimero time calibrator
|
Run 1000 : MUVI 1 X
Time calibrator 20ns period, 512ns range |
Fixed, e748, Thu Jul 20 11:07:54 2017, e748, CATS, General, N/A, Run 1035 calib cats1
|
After experiment CATS 1 pulser calibration
Pulser Quality: very bad - to be analyzed with care
Calibration almost unchanged |
Fixed, e748, Thu Jul 20 11:09:34 2017, e748, CATS, General, N/A, Run 1036 calib cats 2 Y
|
After experiment pulser calibration CATS 2 (Y)
1st amplitude slightly saturates CATS 2 X.
Use for CATS 2 Y recalibration
|
Pinned, e744, Thu Mar 15 10:50:00 2018, Adrien Matta, MUST2, Hardware, , Distribution box LPC 8x
|
Cabling file by Fabien Naury (LPC). |
Pinned, e744, Mon Mar 26 11:44:27 2018, e744 : Valerian, OTHER, General, , Current Elog state
|
Currently we do not have access to the experiment number. To write an entry for e744 the nickname TEST will be used. |
Fixed, e744, Mon Mar 26 11:46:43 2018, e744 : Valerian, RUN, General, 3-alpha, Tests runs Ganacq log
|
(15:51:33 - 19/03/2018) INFO - rcc_gui - Started run #1
(16:22:01 - 19/03/2018) INFO - rcc_gui - Stopped run #1
|
|