MUST2
SAMURAI_2018
S3-LEB-LPC
SUPERNEMO
MUGAST
EXPAND
SCALP
GALATRON
HiCARI
VELO
MUGAST, Page 87 of 132
Not logged in
Find
|
Login
Full |
Summary
|
Threaded
|
Hide attachments
2636 Entries
Goto page
Previous
1
,
2
,
3
...
86
, 87,
88
...
130
,
131
,
132
Next
Status
ExpNbr
Date
Author
Type
Category
Target-Source
Subject
Fixed
e786s
Wed Jun 26 15:50:36 2019
OttoRun
RUN
General
Cryo-3He
Run60
OttoRun wrote:
OttoRun wrote:
*************************
Run : 60
*************************
Start at 2019-06-26 10:21:51.572979
target 700mb
Brho0=0.95 Tm
DC pressure 6 mbar
IC pressure 120 mbar
CATS2 inserted
AGATA position +51-25 mm
TRIGGER :
- VAMOS %1000
- CMG
- MM
- CATS2 %1000
Restarted GTS Tree by Emmanuel
No Beam since 15:00. According to PCP there will be no beam for a while.
Attachment 1:
run60_6.png
Fixed
e786s
Wed Jun 26 16:59:07 2019
Louis
BEAM
General
Cryo-3He
Beam interuption
Beam stopped from 15h to 17h due to source instabilities
Fixed
e786s
Wed Jun 26 18:12:18 2019
OttoRun
RUN
General
Cryo-3He
Run62
*************************
Run : 62
*************************
Start at 2019-06-26 18:09:42.882502
target 700mb
Brho0=0.90 Tm
DC pressure 6 mbar
IC pressure 120 mbar
CATS2 inserted
AGATA position +51-25 mm
TRIGGER :
- VAMOS %1000
- CMG
- MM
- CATS2 %1000
Crate in System faillure.
Moving FIFO FPMW to other crate. Had to change the cable (3ns to 5ns).
To be accounted for in the TOF
Stop at 2019-06-27 02:19:17.492600
Stop comment:
Problems with AGATA, run stopped
Fixed
e786s
Wed Jun 26 20:46:20 2019
Sylvain, Louis
RUN
General
Cryo-3He
run 62 screenshots
Attachment 1:
Vamos10.png
Attachment 2:
Vamos9.png
Attachment 3:
Vamos8.png
Attachment 4:
Vamos7.png
Attachment 5:
Vamos6.png
Attachment 6:
Vamos5.png
Attachment 7:
Vamos4.png
Attachment 8:
Vamos3.png
Attachment 9:
Vamos2.png
Attachment 10:
Vamos1.png
Attachment 11:
Vamos.png
Attachment 12:
MGToD3.png
Attachment 13:
MGToD2.png
Attachment 14:
MGToD1.png
Attachment 15:
MMToD.png
Attachment 16:
MGImpact.png
Attachment 17:
MMImpact.png
Attachment 18:
scaler.png
Fixed
e786s
Thu Jun 27 00:26:37 2019
mugast
OFFLINE
General
statistics until now
Maybe some stat still to recover from better gate and mass and Z reconstruction.
Andrea
Attachment 1:
cqnvqs_.png
Fixed
e786s
Thu Jun 27 03:33:26 2019
OttoRun
RUN
General
Cryo-3He
Run63
*************************
Run : 63
*************************
Start at 2019-06-27 03:33:09.910218
target 700mb
Brho0=0.90 Tm
DC pressure 6 mbar
IC pressure 120 mbar
CATS2 inserted
AGATA position +51-25 mm
TRIGGER :
- VAMOS %1000
- CMG
- MM
- CATS2 %1000
Crate in System faillure.
Moving FIFO FPMW to other crate. Had to change the cable (3ns to 5ns).
To be accounted for in the TOF
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
Current ~ 30 kHz.
The cryo target pressure and temperature have slightly increased during the stop for the recover of AGATA, even before the refilling of the LHe tank.
It is probably due to a problem in the refilling of liquid nitrogen.
Stop at 2019-06-27 11:46:17.108352
Stop comment:
stop
Fixed
e786s
Thu Jun 27 12:28:58 2019
OttoRun
RUN
General
Cryo-3He
Run67
*************************
Run : 67
*************************
Start at 2019-06-27 12:28:26.879061
target 700mb
Brho0=0.90 Tm
DC pressure 6 mbar
IC pressure 120 mbar
CATS2 inserted
AGATA position +51-25 mm
TRIGGER :
- VAMOS %1000
- CMG
- MM
- CATS2 %1000
Crate in System faillure.
Moving FIFO FPMW to other crate. Had to change the cable (3ns to 5ns).
To be accounted for in the TOF
Stop at 2019-06-27 12:46:41.949098
Stop comment:
Fixed
e786s
Thu Jun 27 16:35:45 2019
OttoRun
RUN
General
Cryo-3He
Run68
*************************
Run : 68
*************************
Start at 2019-06-27 16:35:24.351472
target 700mb
Brho0=0.90 Tm
DC pressure 6 mbar
IC pressure 120 mbar
CATS2 inserted
AGATA position +51-25 mm
TRIGGER :
- VAMOS %1000
- CMG
- MM
- CATS2 %1000
Fixed
e786s
Thu Jun 27 16:41:55 2019
OttoRun
RUN
General
Cryo-3He
Run65
*************************
Run : 65
*************************
Start at 2019-06-27 11:35:21.078920
target 700mb
Brho0=0.90 Tm
DC pressure 6 mbar
IC pressure 120 mbar
CATS2 inserted
AGATA position +51-25 mm
TRIGGER :
- VAMOS %1000
- CMG
- MM
- CATS2 %1000
Crate in System faillure.
Moving FIFO FPMW to other crate. Had to change the cable (3ns to 5ns).
To be accounted for in the TOF
Stop at 2019-06-27 17:39:22.529443
Stop comment:
Fixed
e786s
Thu Jun 27 17:43:15 2019
OttoRun
RUN
General
Cryo-3He
Run69
*************************
Run : 69
*************************
Start at 2019-06-27 17:42:38.280555
target 700mb
Brho0=0.90 Tm
DC pressure 6 mbar
IC pressure 120 mbar
CATS2 inserted
AGATA position +51-25 mm
TRIGGER :
- CMG
Test with only MUGAST back trigger
Stop at 2019-06-27 17:54:02.829540
Stop comment:
Fixed
e786s
Thu Jun 27 17:59:20 2019
OttoRun
RUN
General
Cryo-3He
Run70
*************************
Run : 70
*************************
Start at 2019-06-27 17:58:29.855367
target 700mb
Brho0=0.90 Tm
DC pressure 6 mbar
IC pressure 120 mbar
CATS2 inserted
AGATA position +51-25 mm
TRIGGER :
- CMG
- M2
- VAMOS%1000
- CATS%1000
back to normal
Stop at 2019-06-27 18:37:51.816766
Stop comment:
type your message here
Fixed
e786s
Thu Jun 27 18:48:51 2019
OttoRun
RUN
General
Cryo-3He
Run71
*************************
Run : 71
*************************
Start at 2019-06-27 18:47:56.171341
target 700mb
Brho0=0.90 Tm
DC pressure 6 mbar
IC pressure 120 mbar
CATS2 inserted
AGATA position +51-25 mm
TRIGGER :
- MG
- square (not biased)
- M2
all X on MUVI disabled from trigger
all threshold of MUVI1 at 1 MeV to avoid as much as possible noise
Stop at 2019-06-27 20:23:56.630240
Stop comment:
Fixed
e786s
Thu Jun 27 20:26:27 2019
OttoRun
RUN
General
Cryo-3He
Run73
*************************
Run : 73
*************************
Start at 2019-06-27 20:26:17.916314
target 700mb
Brho0=0.90 Tm
DC pressure 6 mbar
IC pressure 120 mbar
CATS2 inserted
AGATA position +51-25 mm
TRIGGER :
- CMG
- M2
- VAMOS%1000
- CATS%1000
all X on MUVI disabled from trigger
all threshold of MUVI1 at 1 MeV to avoid as much as possible noise
There is no run 72
Stop at 2019-06-27 23:04:45.884452
Stop comment:
AGATA DAQ is rejectting all events
Fixed
e786s
Thu Jun 27 23:28:30 2019
OttoRun
RUN
General
Cryo-3He
Run74
*************************
Run : 74
*************************
Start at 2019-06-27 23:25:00.455575
target 700mb
Brho0=0.90 Tm
DC pressure 6 mbar
IC pressure 120 mbar
CATS2 inserted
AGATA position +51-25 mm
TRIGGER :
- CMG
- M2
- VAMOS%1000
- CATS%1000
all X on MUVI disabled from trigger
all threshold of MUVI1 at 1 MeV to avoid as much as possible noise
Stop at 2019-06-28 09:31:40.775271
Stop comment:
Fixed
e786s
Fri Jun 28 04:21:48 2019
Daniele Mengoni
RUN
General
Cryo-3He
run 74
screenshots run 74 attached
frequent error message on the FP DC Wi1 --> defqlt. The elog said so, card tripped, but spectra are still present .. puzzling
Attachment 1:
Q_vs_Xf_K1.png
Attachment 2:
Q_vs_Xf_K2.png
Attachment 3:
Q_vs_Xf_K3.png
Attachment 4:
Q_vs_Xf_K4.png
Attachment 5:
Q_vs_Xf_K5.png
Attachment 6:
Q_vs_Xf_K6.png
Attachment 7:
Q_vs_Xf_K7.png
Attachment 8:
Q_vs_Xf_K8.png
Attachment 9:
Q_vs_Xf_K9.png
Attachment 10:
Q_vs_Xf_K10.png
Attachment 11:
Q_vs_Xf_K11.png
Attachment 12:
Q_vs_Xf_K12.png
Attachment 13:
Q_vs_Xf_K13.png
Attachment 14:
Q_vs_Xf_K14.png
Attachment 15:
Q_vs_Xf_K15.png
Attachment 16:
Q_vs_Xf_K16.png
Attachment 17:
Q_vs_Xf_K17.png
Attachment 18:
Q_vs_Xf_K18.png
Fixed
e786s
Fri Jun 28 08:54:50 2019
Freddy
RUN
General
Cryo-3He
run 74
Daniele Mengoni wrote:
screenshots run 74 attached
frequent error message on the FP DC Wi1 --> defqlt. The elog said so, card tripped, but spectra are still present .. puzzling
Put the voltage back at 8h00 when i arrived.
Fixed
e786s
Fri Jun 28 08:57:21 2019
Freddy
CATS
General
Cryo-3He
CATS scaler not compatible with beam rate
The CATS scaler si now around 100-120 kHz while the beam rate is still 40 kHz.
I checked the CATS signal and there is clearly noise who induce double logic signals. Not all of them are validated by FAG.
We should raise the threshold- call sebastien
9h32 : Stop beam to enter and raise the threshold.
Attachment 1:
ScalerCATSproblem.png
Fixed
e786s
Fri Jun 28 09:56:59 2019
Bertrand, Valerian and Adrien
BEAM
General
N/A
Dipole stopped in the morning?
Dipole restart at 10. Shoudl be checked with time stamp.
Fixed
e786s
Fri Jun 28 10:00:25 2019
OttoRun
RUN
General
Cryo-3He
Run75
*************************
Run : 75
*************************
Start at 2019-06-28 09:59:59.505010
target 700mb
Brho0=0.90 Tm
DC pressure 6 mbar
IC pressure 120 mbar
CATS2 inserted
AGATA position +51-25 mm
TRIGGER :
- CMG
- M2
- VAMOS%1000
- CATS%1000
all X on MUVI disabled from trigger
all threshold of MUVI1 at 1 MeV to avoid as much as possible noise
CATS threshold raised
Stop at 2019-06-28 14:33:09.843668
Stop comment:
Fixed
e786s
Fri Jun 28 15:25:12 2019
OttoRun
RUN
General
Cryo-3He
Run76
*************************
Run : 76
*************************
Start at 2019-06-28 15:24:51.867946
target 700mb
Brho0=0.90 Tm
DC pressure 6 mbar
IC pressure 120 mbar
CATS2 inserted
AGATA position +51-25 mm
TRIGGER :
- CMG
- M2
- VAMOS%1000
- CATS%1000
all X on MUVI disabled from trigger
all threshold of MUVI1 at 1 MeV to avoid as much as possible noise
beam back. Q pole issues still
Stop at 2019-06-28 16:55:27.258794
Stop comment: