Fixed, e775s, Wed Feb 26 15:12:02 2020, Marlène, RUN, General, , RUN 137 8x
|
Screenshots of RUN137
[quote="Marlène"]RUN 137
|
Fixed, e775s, Mon Feb 24 17:14:57 2020, mugast, RUN, General, CD2, RUN 124
|
*************************
Run : 124
*************************
|
Fixed, TEST, Sun Feb 23 20:50:06 2020, Marlène, GRIT, General, , RUN 115 8x
|
Screenshots from MUGAST
The impact matrix looks fine but there are sectors missing but in the raw we see 13 sectors (instead of 16)
|
Fixed, e768s, Fri Jul 19 01:05:26 2019, mugast, RUN, General, , RUN 108
|
Brho Change to 0.556 Tm
Moving Plate : Final Position +7mm
|
Fixed, e768s, Fri Jul 19 00:59:20 2019, mugast, RUN, General, , RUN 107 - Reference Target Run
|
Reference Target Run after beam tuning
Brho 0.5854 Tm |
Fixed, e768s, Tue Jul 16 19:21:19 2019, mugast, OTHER, General, , Qpole values
|
Brho = 0.640 Tm
RMN = 3247,742 Gaus (215.630 A)
|
Fixed, e793s, Fri Mar 12 10:52:46 2021, Adrien, VAMOS, Hardware, N/A, Q pole trip in vamos
|
Q-Pole tripped this night around 4am at the same time as the dipole but was switch on again only at 9am. |
Fixed, TEST, Tue Dec 3 18:14:45 2019, Marlène & Franco, GRIT, Hardware, , Pulser test of new board
|
The new board that will be installed for MG2 has been tested and validated with a pulser outside of the chamber. |
Fixed, TEST, Fri Feb 5 12:44:42 2021, Franco, GRIT, Hardware, N/A, Pulser on MG11 MUFEE Y  
|
I managed to obtain the spectrum with the pulser on the annular (Y side, namely sectors).
The raw strip numbers where I should have the 16 sectors are: 14, 16, 18, 20, 22, 24, 26, 28, 36, 38, 40, 42, 44, 46, 48 and 50.
The 5 strips I could see with the alpha source are: 20, 40, 44, 48, 50.
|
Fixed, e768s, Sat Jul 13 16:28:30 2019, Diego Ramos, OTHER, General, N/A, Proton ToF from VAMOS ToF reconstruction
|
Comparison between the Proton ToF measured directly with the TAC between MUST and CATS (left) and the one recontructed from the time diference between the
time MUGAST-VAMOS and the time Target-VAMOS (recontructed from the Brho) (right)
|
Fixed, e768s, Mon Jul 22 17:07:39 2019, Marlène, Franck, François & Nicolas, BEAM, General, , Profiler conditions for measuring beam intensity
|
We checked that the measured beam intensity (present case 1.5e7 pps) is independent on the voltage on the profiler. Values from 93 V up to 177 V gave similar
results. |
Fixed, e768s, Tue Jul 23 12:00:25 2019, Christian, BEAM, General, LiF, Profiler and beam current scaling since 11;10
|
See also AGATA elog and run-log entry |
Fixed, e744s, Fri Apr 12 10:36:09 2019, Valerian, RUN, General, N/A, Procedure to follow during runs
|
[SIZE=4][B][SIZE=3]At the beginning of a run :
[/B]
[LIST]
|
Fixed, e786s, Mon Jun 24 01:52:00 2019, Louis, OFFLINE, Software, Cryo-3He, Procedure to convert and calibrate runs
|
Here is the updated procedure to convert a run, with VAMOS data.
|
Fixed, e768s, Fri Jul 19 15:11:10 2019, mugast, OFFLINE, General, , Procedure for run conversion and analysis
|
Here is the procedure to convert a run with VAMOS and AGATA data and add those data to the Kinematic plot.
Every 4GB there will be a file change, to see if there is a file change type:
|
Fixed, TEST, Thu Feb 4 18:16:47 2021, Franco, GRIT, Hardware, 3-alpha, Problems with the annular persist 8x
|
We opened the chamber to verify the connections of the kaptons but they were all well connected. We checked with the tester the conductivity of the kapton
YA5 and it was fine so we excluded any problem related to the kapton. The boards are working properly (the pulser is well seen). We have to conclude that
the problem comes from the detector. We made another alpha source run and indeed the result is the same as yesterday -> 5 sectors working on Y. We also |
Pending, e793s, Sat Mar 13 05:11:08 2021, Faïrouz, Juan Lois, AGATA, Software, CD2, Problem with AGATA acquisition started at 4h40
|
There is a problem with AGATA Acquisition. All the bars in the global status & control are yellow!!!
This problem started at 4h40.
|
Fixed, e768s, Thu Jul 25 12:55:19 2019, mugast, AGATA, General, LiF, Problem Crystal 00A during run 140
|
Problem with crystal 00A at 12h50:
- Very large counting rate 300 k
|
Ongoing, e793s, Wed Mar 10 21:09:25 2021, mugast (Adrien, Nigel et co), BEAM, General, , Primary beam issues
|
The secondary beam intensity has been fluctuating around 4 - 5 x 10**5 Hz most of the evening. 15 mins ago it was realised that it had dropped off to
only 1 x 10**5 Hz. As suspected, PCP confirmed that primary beam intensity has dropped off. They are investigating ...
|
Fixed, e768s, Sat Jul 20 11:33:01 2019, Christian, OTHER, General, , Previous Papers - gamma decays from states in the 4-MeV region
|
This search was triggered by our lack of seeing the 3958keV line at the expected level. 2689 keV line observed (runs 112,115,116) as 55-60 counts. Expected
yield in 3958 keV line based on 80:20 branching and 1.5:1.0 efficiency is 10 counts. We see (at most) 2 in the full photo-peak for this line. (Theses two
counts are also lower than expected by about 20 keV.)
|
|