MUST2
SAMURAI_2018
S3-LEB-LPC
SUPERNEMO
MUGAST
EXPAND
SCALP
GALATRON
HiCARI
VELO
MUGAST, Page 48 of 132
Not logged in
Find
|
Login
Full
| Summary |
Threaded
2636 Entries
Goto page
Previous
1
,
2
,
3
...
47
, 48,
49
...
130
,
131
,
132
Next
Status
ExpNbr
Date
Author
Type
Category
Target-Source
Subject
Text
Fixed
e744s
Thu Apr 18 17:36:56 2019
OttoRun
RUN
General
N/A
Run228
*************************
[SIZE=3][B]Run : 228[/B][/SIZE]
*************************
Fixed
e744s
Thu Apr 18 17:45:45 2019
Valerian
OTHER
Hardware
N/A
Start heating and stopping Voltage + Acq
HV+BT are off and heating is started for Arnaud
to open the chamber
Fixed
e744s
Wed Apr 24 15:01:01 2019
Valerian
OTHER
Hardware
N/A
Electronic scheme on the MUGAST side after experiment e744
Attached are schematics of the electronics.
Fixed
e744s
Fri Apr 26 11:29:02 2019
Valerian
OTHER
Software
N/A
Notes about the electronic
While doing the electronic scheme, I saw that
the Inspection line was inducing a bad signal
in the coincidence module between fag and
Fixed
TEST
Mon May 27 16:17:48 2019
OttoRun
RUN
General
3-alpha
Run229
*************************
[SIZE=3][B]Run : 229[/B][/SIZE]
*************************
Fixed
TEST
Tue May 28 10:43:58 2019
OttoRun
RUN
General
3-alpha
Run229
*************************
[SIZE=3][B]Run : 229[/B][/SIZE]
*************************
Fixed
TEST
Tue May 28 11:08:10 2019
mugast
MUST2
Hardware
3-alpha
MG3 is tripping
MG3T is tripping, tryied to set max current
to 20uA but it still trip around 30V.
Fixed
TEST
Thu May 30 15:42:13 2019
OttoRun
RUN
General
3-alpha
Run229
*************************
[SIZE=3][B]Run : 229[/B][/SIZE]
*************************
Fixed
TEST
Thu May 30 15:55:15 2019
OttoRun
RUN
General
3-alpha
Run229
*************************
[SIZE=3][B]Run : 229[/B][/SIZE]
*************************
Fixed
TEST
Thu May 30 15:58:20 2019
OttoRun
RUN
General
3-alpha
Run230
*************************
[SIZE=3][B]Run : 230[/B][/SIZE]
*************************
Fixed
TEST
Thu May 30 16:04:09 2019
OttoRun
RUN
General
3-alpha
Run230
*************************
[SIZE=3][B]Run : 230[/B][/SIZE]
*************************
Fixed
TEST
Thu May 30 16:08:39 2019
OttoRun
RUN
General
3-alpha
Run230
*************************
[SIZE=3][B]Run : 230[/B][/SIZE]
*************************
Fixed
TEST
Thu May 30 16:10:18 2019
OttoRun
RUN
General
3-alpha
Run230
*************************
[SIZE=3][B]Run : 230[/B][/SIZE]
*************************
Fixed
e786s
Fri May 31 09:53:14 2019
Marlène
GRIT
General
Alpha source --> status of detectors
MG3T has been fixed by changing the X kapton.
I have removed aluminium foil on square detectors,
Fixed
e786s
Mon Jun 3 18:00:10 2019
Marlène
GRIT
General
MUGAST detectors status --> MG4T
The problem of MG4T ha sbeen solved by changing
the feedthrough.
The pulser on Y was not working and we were
Fixed
TEST
Tue Jun 11 18:59:36 2019
OttoRun
RUN
General
3-alpha
Run231
*************************
[SIZE=3][B]Run : 231[/B][/SIZE]
*************************
Fixed
TEST
Tue Jun 11 21:44:38 2019
OttoRun
RUN
General
3-alpha
Run232
*************************
[SIZE=3][B]Run : 232[/B][/SIZE]
*************************
Fixed
e786s
Wed Jun 12 17:59:01 2019
mugast
OTHER
Software
Online Energy Calibration
Updated Online Energy calibration for MUGAST,
based on run_0231 data
Fixed
e786s
Wed Jun 12 18:11:04 2019
mugast
OTHER
Software
Online Energy Calibration
Fixed
TEST
Wed Jun 12 18:40:57 2019
OttoRun
RUN
General
3-alpha
Run233
*************************
[SIZE=3][B]Run : 233[/B][/SIZE]
*************************
Goto page
Previous
1
,
2
,
3
...
47
, 48,
49
...
130
,
131
,
132
Next
ELOG Home Page