Status |
ExpNbr |
Date |
Author |
Type |
Category |
Target-Source |
Subject |
Fixed | e768s |
Thu Jul 11 16:54:34 2019 |
OttoRun | RUN | General | 3-alpha | Run302 |
*************************
Run : 302
*************************
Start at 2019-07-11 16:54:22.512184
3 alpha calibration run
+ without MM2 masks
+ suppressed pedestals
Square detectors:
+ MG10: all X strips masked; mate 14 & 16 masked
+ MG9: all X & Y strips masked
Stop at 2019-07-12 05:44:35.805449
Stop comment: |
Fixed | e768s |
Fri Jul 12 12:07:56 2019 |
mugast | OTHER | General | N/A | Masks for MUST2 |
Masks for MUST2 are now mounted.
NOTE: one mask is not properly screwed (top left) and should be mounted again on Monday morning when we open.
Masks cover theta_lab < 38 deg, corresponding to < 30 pps of 15O for 15O+19F elastic channel assuming 2e7 pps of 15O and 1.25 mg/cm2 of LiF. |
Fixed | e768s |
Fri Jul 12 15:04:35 2019 |
OttoRun | RUN | General | 3-alpha | Run303 |
*************************
Run : 303
*************************
Start at 2019-07-12 15:03:55.487806
3 alpha calibration run
+ MM2 masks
+ suppressed pedestals
Square detectors:
+ MG10: all X &Y strips masked;
+ MG9 removed
Stop at 2019-07-12 15:05:24.820669
Stop comment: type your message here |
Fixed | e768s |
Fri Jul 12 15:05:42 2019 |
OttoRun | RUN | General | 3-alpha | Run303 |
*************************
Run : 303
*************************
Start at 2019-07-12 15:05:39.990342
3 alpha calibration run
+ MM2 masks
+ suppressed pedestals
Square detectors:
+ MG10: all X &Y strips masked;
+ MG9 removed
Stop at 2019-07-12 15:21:45.059356
Stop comment:
Stop at 2019-07-12 16:21:07.294470
Stop comment: type your message here |
Fixed | e768s |
Fri Jul 12 16:22:04 2019 |
OttoRun | RUN | General | 3-alpha | Run303 |
*************************
Run : 303
*************************
Start at 2019-07-12 16:22:02.189158
3 alpha calibration run
+ MM2 masks
+ suppressed pedestals
Square detectors:
+ MG10: all X &Y strips masked;
+ MG9 removed
Stop at 2019-07-12 16:33:58.493008
Stop comment: type your message here |
Fixed | e768s |
Fri Jul 12 16:35:10 2019 |
OttoRun | RUN | General | 3-alpha | Run303 |
*************************
Run : 303
*************************
Start at 2019-07-12 16:35:04.481793
3 alpha calibration run
+ MM2 masks
+ suppressed pedestals
Square detectors:
+ MG10: all X &Y strips masked;
+ MG9 removed
Stop at 2019-07-12 16:38:40.222071
Stop comment: type your message here |
Fixed | e768s |
Fri Jul 12 16:42:22 2019 |
OttoRun | RUN | General | 3-alpha | Run303 |
JUNK
*************************
Run : 303
*************************
Start at 2019-07-12 16:41:50.518089
3 alpha calibration run
+ MM2 masks
+ suppressed pedestals (new pedestal for all trap detectors)
Square detectors:
+ MG10: not biased
+ MG9 removed
Stop at 2019-07-12 16:43:54.495178
Stop comment: type your message here |
Fixed | e768s |
Fri Jul 12 16:45:00 2019 |
OttoRun | RUN | General | 3-alpha | Run304 |
JUNK
*************************
Run : 304
*************************
Start at 2019-07-12 16:44:54.903528
3 alpha calibration run
+ MM2 masks
+ suppressed pedestals (new pedestal for all trap detectors)
Square detectors:
+ MG10: not biased
+ MG9 removed
Stop at 2019-07-12 16:46:13.603283
Stop comment: |
Fixed | e768s |
Fri Jul 12 16:58:52 2019 |
OttoRun | RUN | General | 3-alpha | Run305 |
JUNK
*************************
Run : 305
*************************
Start at 2019-07-12 16:58:50.871657
3 alpha calibration run
+ MM2 masks
+ suppressed pedestals (new pedestal for all trap detectors)
Square detectors:
+ MG10: not biased
+ MG9 removed
Stop at 2019-07-12 17:00:35.578929
Stop comment: type your message here |
Fixed | e768s |
Fri Jul 12 17:08:58 2019 |
OttoRun | RUN | General | 3-alpha | Run305 |
JUNK no pedestal suppression on MG3
*************************
Run : 305
*************************
Start at 2019-07-12 17:08:47.400117
3 alpha calibration run
+ MM2 masks
+ suppressed pedestals (new pedestal for all trap detectors)
Square detectors:
+ MG10: not biased
+ MG9 remove
Pedestals shifted on MG3 due to noise on one over 2 mates
Stop at 2019-07-12 17:16:35.681417
Stop comment: |
Fixed | e768s |
Fri Jul 12 17:17:22 2019 |
OttoRun | RUN | General | 3-alpha | Run306 |
*************************
Run : 306
*************************
Start at 2019-07-12 17:17:19.657074
3 alpha calibration run
+ MM2 masks
+ suppressed pedestals (new pedestal for all trap detectors)
Square detectors:
+ MG10: not biased
+ MG9 removed
Stop at 2019-07-14 21:18:42.648096
Stop comment: stopping for heating cooling system after unbiasing MUGAST
Stop at 2019-07-15 15:36:28.594934
Stop comment: type your message here
Stop at 2019-07-15 16:25:22.582232
Stop comment: type your message here
Stop at 2019-07-15 18:02:50.677903
Stop comment: changing ADC channel for T_AGATA_HF |
Fixed | e768s |
Fri Jul 12 17:51:06 2019 |
mugast (Sylvain, Chloe, François, Marlène, Nicolas) | OTHER | General | | Monitoring of beam profile with BAF2 |
In order to provide a efficient way for PCP to monitor beam profile a new TAC measurement has set up.
A BAF2 detector has been inserted close to the reaction chamber (in position 7 of AGATA structure frame). Operating voltage of BaF2 is 1800V and the typical signal amplitude is above 100 mV.
The output signal is sent to a TFA (with gain =1). No additional delay was used. The BAF2 trigger signal is made from CFD and used as a start a TAC. TAC range was chosen to 1us.
The trigger signal was also sent to GMT trough input nb 5.
|
Fixed | e768s |
Sat Jul 13 16:28:30 2019 |
Diego Ramos | OTHER | General | N/A | Proton ToF from VAMOS ToF reconstruction |
Comparison between the Proton ToF measured directly with the TAC between MUST and CATS (left) and the one recontructed from the time diference between the time MUGAST-VAMOS and the time Target-VAMOS (recontructed from the Brho) (right)
The resolution of the recontructed time looks slightly degraded with respect to the direct measurement but it is certainly much better than using the HF. Still, the resolution of the reconstructed time may be improved with a fine alignment of the different sections of the PPAC and with a better selection of the M/q in VAMOS. |
Fixed | e768s |
Mon Jul 15 12:57:53 2019 |
Aranaud, Nicolas, Marlène, François | TARGET | General | LiF | Targets position |
Targets have been mounted on target ladder and are now in reaction chamber |
Fixed | e768s |
Mon Jul 15 14:29:47 2019 |
Marlène | MUST2 | General | | Masks for MUST2 & Kapton changed for MG5 |
Masks are now correctly mounted
All 4 kaptons from MG5 have been changed |
Fixed | e768s |
Mon Jul 15 14:38:27 2019 |
Franco | RUN | General | 3-alpha | Run302 |
Attached the calibrated spectra for MUST2 and Mugast for run 302 (no pedestals).
OttoRun wrote: | *************************
Run : 302
*************************
Start at 2019-07-11 16:54:22.512184
3 alpha calibration run
+ without MM2 masks
+ suppressed pedestals
Square detectors:
+ MG10: all X strips masked; mate 14 & 16 masked
+ MG9: all X & Y strips masked
Stop at 2019-07-12 05:44:35.805449
Stop comment: |
|
Fixed | e768s |
Mon Jul 15 18:05:14 2019 |
Iulian, Serge | RUN | General | N/A | Run7 - TAC calibration |
*************************
Run : 7
*************************
Start at 2019-07-15 18:04:51.105052
TAC Time calibrator
range 2.56 um
period 20ns
TACs range settings:
1. VAMOS - AGATA -> 500 ns
2. FAG - HF -> 200 ns
3. CATAS1 - HF -> 500 ns
4. VAMOS - HF -> 2 us
5. MUGAST - VAMOS -> 2 us
6. MUST2 - AGATA -> 2 us
7. MUST2 - HF -> 2 us
8. BAF2 - HF -> 1 us
9. AGATA - HF -> 200 ns
Stop at 2019-07-15 18:16:11.458928
Stop comment: Finish 1st time calibration. Changing ranges now |
Fixed | e768s |
Mon Jul 15 18:17:49 2019 |
Iulian, Serge | RUN | General | N/A | Run8 - TAC calibrations |
*************************
Run : 8
*************************
Start at 2019-07-15 18:17:21.942994
TAC Time calibrator
range 2.56 um
10 ns period |
Fixed | e768s |
Mon Jul 15 18:28:19 2019 |
Franco | RUN | General | 3-alpha | Run301 |
Attached the calibrated spectra for MUST2 and Mugast for run 301.
OttoRun wrote: | *************************
Run : 301
*************************
Start at 2019-07-11 15:07:27.670320
3 alpha calibration run
+ without MM2 masks
+ non suppressed pedestals
Square detectors:
+ MG10: all X strips masked; mate 14 & 16 masked
+ MG9: all X & Y strips masked
Stop at 2019-07-11 16:52:55.206383
Stop comment: stopping run to put pedestal suppression |
|
Fixed | e768s |
Mon Jul 15 18:39:03 2019 |
Iulian, Serge | RUN | General | N/A | Run9 - TAC calibration |
*************************
Run : 9
*************************
Start at 2019-07-15 18:38:59.133455
TAC Time calibrator
range 2.56 um
10 ns period
Stop at 2019-07-15 19:04:03.255467
Stop comment: type your message here
Stop at 2019-07-15 19:18:09.593144
Stop comment: end of tac time calibration |