Fixed, com2019, Fri Apr 5 11:26:09 2019, Adrien, Freddy and the world, OFFLINE, General, N/A, Mask reconstruction CATS1-CATS2 run 223  
|
Mask between CATS1 and CATS2 in Z=-2190 Reconsctruction with nptool and attached mugast.detector and ConfigCATS.dat attached.
The beam seems to be shifted strongly to the [B]left[/B] of the beam line during the run. not clear yet if the shift of the mask is due to :
shift of cats
shift of the mask itself
|
Fixed, e793s, Fri Mar 19 09:54:58 2021, Adrien, Freddy and Franco, GRIT, General, 3-alpha, Alpha calibration and noise on MG3 and MG4 after the experiment
|
While starting the alpha source runs after the experiment we found unexpected noise on MG3 and MG4 which cannot be excluded just by masking some Y mates
(The X mates were already masked for both of them). We cannot figure out the origin of this noise.
|
Fixed, com2019, Fri Apr 5 23:19:04 2019, Adrien et Valerian, OFFLINE, General, CD2, Experimental Kinematic Line from dp
|
[SIZE=3]We used run 253 to obtain a convincing Kine line and Ex spectrum at backward angle.
Stat is still limited but the distribution is convincing.[/SIZE] |
Pinned, com2019, Fri Apr 5 23:34:46 2019, Adrien et Valerian, OFFLINE, General, N/A, Converting data and adding stat to Kine Plot
|
Here is a procedure to convert a run and add data the Kinematic plot.
Every 4Go there will be a file change, convert the file and add it to the chain using the following step:
|
Fixed, TEST, Thu Mar 21 10:37:47 2019, Adrien and Valerian, MUST2, General, N/A, Test TOF must2
|
To make sure the mate work correctly we took an alpha run with a delayed fag on the MUVI stop:
- all mate register a time in the the middle of the range as expected (fag delayed by 350ns, range is 600ns)
|
Fixed, e744s, Thu Apr 11 10:38:13 2019, Adrien and Valerian, BEAM, General, N/A, They are preparing 14O beam
|
News from (edit after talking to Pierre D.)
[LIST]
[*] They are preparing the 14O beam.
|
Fixed, e793s, Mon Feb 8 11:25:29 2021, Adrien and Freddy, S1, General, N/A, FSC run 
|
we ran FSC on all card. S1 is dismounted.
Pulser goes on all channel and works well so electronic is fine.
We will ask Laurent to remount the detector and re run the test. |
Fixed, TEST, Fri Jan 18 15:32:50 2019, Adrien Valérian, GRIT, General, N/A, Calimero tests Muvi2 MM7 MG10C 
|
After disabling nptool Multithreading, online is working fine again.
Concerning Calimero, it is currently working both on MUVI1 and MUVI2 for the X at least.
|
Fixed, e744s, Tue Apr 9 15:48:00 2019, Adrien Valerian, OFFLINE, General, CD2, Expected gamma background in coincidence with proton in MUST2
|
[SIZE=3]This is a plot of the Gamma in AGATA in coincidence with proton in MUST2 for the entire run 256.
It gives a hint of the expected gamma background due to fusion evaporation for the upcoming experiment looking for a bump around 3.5 MeV
|
Fixed, e744s, Sat Apr 13 21:34:02 2019, Adrien Matta -> update Iulian, RUN, General, N/A, Inconsistent info in the run message-fix explained in reply
|
Be careful to fill in correctly all info in the start run message.
[B]There is inconsistency in run 121 comment (target 2) and list (target 3).
|
Fixed, TEST, Fri Dec 14 09:08:46 2018, Adrien Matta, OTHER, Social, N/A, Test Post
|
MUGAST ELOG is now ONLINE |
Fixed, TEST, Sat Mar 23 15:26:06 2019, Adrien Matta, OTHER, Software, N/A, To do list
|
[SIZE=2][B]FSC:[/B][/SIZE]
[LIST][COLOR=orange]
[*] Autoconf programme to set all regular parameter (PAC gain, TAC range, ORD, no mask, no pulser)[/COLOR]
|
Fixed, com2019, Sun Mar 31 18:11:28 2019, Adrien Matta, OTHER, General, N/A, To do list for the commissioning (please edit!)
|
[SIZE=3]Here is a to do list of thing we should do ahead of the commissioning. Please self assigned task by putting your name next to it. Don't hesitate
to ask for help, or clarification or anything you might need.
|
Pinned, com2019, Mon Apr 1 11:02:00 2019, Adrien Matta, MUST2, Hardware, N/A, Switching on and off LV/HV for MUST2 crate
|
[SIZE=4]HVM group could be used to switch on and off the LV and HV for the MUST2 crate.
[I]
The command could be lauched from the analysis environment: start a terminal and type:[/I]
|
Fixed, com2019, Wed Apr 3 11:03:53 2019, Adrien Matta, CATS, Hardware, N/A, Cats mask will be shifted
|
The propulsif supporting the cats mask is leaking.
It will be tighten to fix the leak, this lead to a small shift toward the left of the beam when looking at vamos. |
Fixed, com2019, Wed Apr 3 11:05:36 2019, Adrien Matta, DAQ, Software, N/A, MFM scaler reading
|
MfM scaler are read correctly for Must2 U2M but output some -1 for the numexo2 integrated scaler. |
Fixed, com2019, Sat Apr 6 08:38:51 2019, Adrien Matta, OFFLINE, General, CD2, We see d,3he more than d,t at forward angle
|
We see more (d.3he) than dt
there seems to be another reaction going up to 40deg Lab |
Fixed, com2019, Sat Apr 6 10:09:53 2019, Adrien Matta, OFFLINE, General, CD2, We see d,4He
|
[quote="Adrien Matta"]We see more (d.3he) than dt
there seems to be another reaction going up to 40deg Lab[/quote]
|
Fixed, e744s, Sat Apr 13 12:04:56 2019, Adrien Matta, OTHER, Social, N/A, Blow some steam this afternoon (staturday13th)
|
If some of you want to blow some steam this afternoon Crossfit Caen ( located in Mondeville, you. Can find them on google map) is organising an initiation
Wod this afternoon for their 4th anniversary. Here is the program of the day:
Les quatre ans de la boxe commence, on vous attend avec impatience et venez nombreux. 👌🏻💪🏻 Si vous voulez découvrir le |
Ongoing, e744s, Sat Apr 13 21:57:48 2019, Adrien Matta, RUN, General, N/A, Inconsistent info in the run message
|
[quote="Adrien Matta"]Be careful to fill in correctly all info in the start run message.
[B]There is inconsistency in run 121 comment (target 2) and list (target 3).
|
|