MUGAST, Page 129 of 132 |
Not logged in |
|
|
New entries since: | Thu Jan 1 01:00:00 1970 | |
|
Fixed | e768s |
Sun Jul 28 21:59:43 2019 |
Nicolas | RUN | General | | Update on possible restart |
Beam is in G1 with 3e6 pps. PCP will optimize for about 1-1,5h before we take the beam. |
Fixed | e768s |
Tue Jul 30 15:47:46 2019 |
Nicolas | BEAM | General | | Beam stopped since 11h30 |
vacuum problem in CSS1 |
Fixed | e768s |
Wed Jul 31 03:22:42 2019 |
Freddy, Chloé | BEAM | General | | Beam profile (run160) @2h24 |
|
Attachment 1: 20190731_022419.jpg
|
|
Fixed | e768s |
Wed Jul 31 23:06:04 2019 |
Nicolas & Fairouz | OTHER | General | | screenshot fsc |
|
Attachment 1: fsc_OneChannelPerMate.png
|
|
Fixed | TEST |
Tue Dec 3 18:14:45 2019 |
Marlène & Franco | GRIT | Hardware | | Pulser test of new board |
The new board that will be installed for MG2 has been tested and validated with a pulser outside of the chamber. |
Fixed | TEST |
Wed Dec 4 19:19:38 2019 |
Marlène | GRIT | Hardware | | Modifications of set-up |
We have installed the new MUFEE board in the reaction chamber for MG2. This board is a new version with ATHED.
We have moved the MG9 board to become the board to read the future MUST2 detector at 90 deg. This board is now perpendicular to the other ones. We have tested the kaptons connection to the detector and the placement of the detector.
The design will be refined on monday with Patrice.
The board that was reading MG10 is now used for MG6.
Every board has been tested again with pulser under vacuum. Everything seems OK. |
Pending | TEST |
Tue Jan 21 17:55:12 2020 |
Marlène | MUST2 | Hardware | | Ovv error on the -5V of CAEN boards |
The Ovv error shows on the -5V (first one) of the 3 board (5,3.3,10V for MUST2§squares)
It means that the voltage is over the asked value.
If we ask 5V, we get 5.5V in reality
We changed for 4.5V and we get 5V. The current is different from the one on the MUGAST BT box but we don't know how many detectors are connected.
We exchanged cables and found the same current in the other board, so we guess that it is still working properly.
A check of stability should be done. |
Attachment 1: BT_referenve_5V_cables_inv_a_comp_referenve_5V_partMUST2
|
Attachment 2: BT_referenve_5V_partMUST2_cables_inv_a_comp_referenve_5V
|
Attachment 3: BT_referenve_5V_partMUST2
|
Attachment 4: BT_referenve_5V
|
Fixed | TEST |
Wed Jan 22 15:53:25 2020 |
Marlène | GRIT | Hardware | | Changes for MUGAST2020 |
Changes were made for MUGAST 2020 :
1- the board for MG10 before (2nd square) is now for MG6 new trap
2- the board for MG9 is put vertical and used for the MUST2 at 90 deg
3- a new board has been installed for MG2
Now there will be 13 detectors in the chamber: 7 trap + 1 square + 4 MUST2 forward. |
Fixed | |
Wed Jan 22 18:39:54 2020 |
Marlène & Franco | GRIT | Hardware | | Tests of the new box |
The new box has been tested together with the new CAEN SY4527 power supply. We connected a laptop with Linux to the power supply by means of an ethernet cable and communicated with it by opening a browser (http://192.168.0.1, then username: admin and pwd: admin). To control the channels we open a terminal, go to the folder where we saved the file ChannelsController.jar and run the command: java -jar ChannelsController.jar 192.168.0.1 admin admin
The output biases were checked with a test cable connected to the flange output and are reported in the attached file. For comparison we did the same thing on 3 Mugast detectors (MG1, MG3 and MG4) We saw that the polarity of all the 3.3V in the new box was inverted with respect to the Mugast box so we opened the box and, like sappers, we followed the colored cables until we found the ones giving the 3.3V and inverted them. It worked! So now the biases should be correct. A reminder for possible future modifications: the coupled colours for the wires are blue-grey, white-brown, yellow-green.
Some low voltages seem to be unused because they are present in some BT outputs but not in others, but anyway the detectors which are supplied by these cables have always been working properly, so the small differences between different BT outputs might be irrelevant.
It is then important to notice that BT2 and BT3 have a -2.5V instead of a +2.5V so it's recommended not to use them unless the relative cables are first switched inside the box. |
Attachment 1: box_pin_map.pdf
|
|
Fixed | TEST |
Mon Feb 10 18:42:23 2020 |
Franco&Marlène | GRIT | Hardware | | New MUGAST detectors MG2 MG6 |
MG2 and MG6 have been mounted in the chamber.
MG2 reference number is 3227_10 thickness=468um
MG6 3227_7 thickness=473um
Nominal depletion =35V |
Fixed | TEST |
Wed Feb 12 16:24:52 2020 |
Marlène, Freddy & Franco | MUST2 | Hardware | | Modifications on the electronic scheme |
We cleaned the electronic scheme.
Now the HF CLEAN VAMOS is taken directly from VAMOS and not re-cleaned by us.
TACs are all ok. Inspection lines have been checked and labeled.
GMT and Scalers are like below.
GMT:
1 - MUVI 1 (MG1, MG3, MG4, MG5)
2 - MUVI 2 (MG7, MG2, MG6, MG11)
3 - MUVI 3 (MM1, MM2, MM3, MM4)
4 - MUVI 4 (MG9 90-deg MUST2)
5 - COINCIDENCE VAMOS-AGATA
6 - VAMOS DIV
7 - MUST2 DIV
8 - broken
9 - SQUARE DIV
10 - AGATA DIV
11 - VAMOS
12 - empty
13 - empty
14 - empty
15 - broken
16 - empty
SCALERS:
1 - FAG
2 - OR MUGAST
3 - AGATA
4 - VAMOS
5 - empty
6 - DEAD TIME MUGAST
7 - 100 Hz PULSER
8 - DEAD TIME
9 - MUVI 1 (MG1, MG3, MG4, MG5)
10 - MUVI 2 (MG7, MG2, MG6, MG11)
11 - MUVI 3 (MM1, MM2, MM3, MM4)
12 - MUVI 4 (MG9 90-deg MUST2)
13 - empty
14 - empty
15 - CATS2
16 - FINGER |
Fixed | |
Fri Feb 14 10:26:46 2020 |
Franco&Marlène | GRIT | Hardware | | HT BT screenshots before e775s |
Detectors are cooled down to 0 deg. |
Attachment 1: BT_CAEN2_MGnew.png
|
|
Attachment 2: BT_CAEN1_part1_MM.png
|
|
Attachment 3: BT_CAEN1_part2_MG.png
|
|
Attachment 4: HV_part1_MM_MG.png
|
|
Attachment 5: HV_part2_MG.png
|
|