MUST2 SAMURAI_2018 S3-LEB-LPC SUPERNEMO MUGAST EXPAND SCALP GALATRON HiCARI VELO
  MUGAST  Not logged in MUGAST
Message ID: 5390     Entry time: Sat Jul 27 21:12:47 2019
Author: teodora & beyhan 
ExpNbr: e768s 
Type: OTHER 
Category: Hardware 
Status: Fixed 
Target-Source:  
Subject: cout rate with no beam & water level check 
Around 9 pm, we observed an average count rate of 30kHz on the "or agata" scaler rates panel of GECO. The other count rates were ok.
In the agata acquisition monitoring the rate was given about 8k. one of the detector was showing a rate in red.

We decided to stop : (1) to check the rates with no beam, (2) to check the water level in collection boxes and (3) the beam intensity.

Conclusions :

- The agata rate with no beam is about 4.5kHz. The rest seems ok.

- The level of water in the collection boxes did not change since 3 pm. So it should be ok for the night (see pictures)

- The beam profile and intensity are similar to what we got before

- The rate after we got the beam looks normal now.

So everything is going well Smile

PS : there is also a piscture about the water collection tank to empty the boxes if needed

Attachment 1: scalers-run154-nobeam.png  108 kB  Uploaded Sat Jul 27 22:17:39 2019  | Hide | Hide all
scalers-run154-nobeam.png
Attachment 2: IMG_3511.jpg  526 kB  Uploaded Sat Jul 27 22:25:32 2019  | Hide | Hide all
IMG_3511.jpg
Attachment 3: IMG_3512.jpg  656 kB  Uploaded Sat Jul 27 22:25:41 2019  | Hide | Hide all
IMG_3512.jpg
Attachment 4: IMG_3513.jpg  618 kB  Uploaded Sat Jul 27 22:25:50 2019  | Hide | Hide all
IMG_3513.jpg
Attachment 5: IMG_3514.jpg  711 kB  Uploaded Sat Jul 27 22:25:57 2019  | Hide | Hide all
IMG_3514.jpg
Attachment 6: scalers-run154-with_beam.png  108 kB  Uploaded Sat Jul 27 22:27:18 2019  | Hide | Hide all
scalers-run154-with_beam.png

ELOG Home Page