Fixed, e793s, Thu Mar 11 15:48:14 2021, mugast, OFFLINE, General, N/A, Beam energy and Beta 
Beam energy entering G1:    7.6922 MeV/u (Beta= 0.1277)

CATS2 thickness: 2.8 um of Mylar in total + about 4 cm of isobutane at 4 mbar
Fixed, e793s, Thu Mar 11 17:32:07 2021, Faïrouz, Franco, Sarah, RUN, General, CD2, run 56 screenshots 17h30 8x
 
Fixed, e793s, Thu Mar 11 20:23:58 2021, Faïrouz, Franco, RUN, General, CD2, run56 screenshots at 20h18 8x
 
Fixed, e793s, Thu Mar 11 21:14:26 2021, Fairouz & Franco, OFFLINE, General, CD2, Plots run 51-56 plots_51-56.pngEx_thetalab_51-56.png
Top left: kinematic plot with the main levels observed. The orange lines are (d,p), (d,t), (d,d) and (12C,12C) reactions by 47Ti. The yellow line is 47K(p,p),
the green line 47K(d,d).
Top right: in black Ex spectrum with gate on VAMOS, in red with also the gate on a gamma and scaled by a factor 3 for better comparison.
Fixed, e793s, Thu Mar 11 21:29:43 2021, Franco, RUN, General, CD2, Alignment in time of the VAMOS sections VAMOS_T_alignment.png
The aligned time is saved in a variable called MWT in the output tree
Fixed, e793s, Thu Mar 11 23:30:27 2021, Faïrouz, Franco, RUN, General, CD2, run56 screenshots at 23h20 8x
 
Fixed, e793s, Thu Mar 11 23:38:02 2021, Faïrouz, Franco, RUN, General, CD2, No beam at 23h35 for a duration of ~1à mn run56_Scalers_23h44.png
The beam operators took the beam at 23h35 for 10 mn. 
Fixed, e793s, Fri Mar 12 02:01:52 2021, Taras, Nishu, Chloe, Charlie, RUN, General, CD2, run56 screenshots at 02h10 10x
screenshots of run 56 attached below
Fixed, e793s, Fri Mar 12 03:21:01 2021, Taras, Chloe, NIshu, Charlie, VAMOS, General, CD2, VAMOS trip, requires help (FIXED @ 03:55) PXL_20210312_020550869.jpgPXL_20210312_024401845.jpg
We received a call from PCP telling us that VAMOS has tripped. Currents on all focal planes are 0. We tried stopping and restarting the FP_CATS0 - FP_CATS5,
 but this does not resolve the issue. 
Fixed, e793s, Fri Mar 12 03:57:46 2021, Taras, Nishu, Chloe, Charlie, VAMOS, General, CD2, dipole issue fixed run56_dipolefixed.png
the alimentation on dipole (G1.G.D4.P) was turned off,
the value was resetted(322.6) and works fine now.
cour: 323.5 A
Fixed, e793s, Fri Mar 12 04:19:51 2021, Taras, Nishu, Chloe, Charlie, RUN, General, CD2, run56 screenshots at 04h18 14x
Images attached. 
Fixed, e793s, Fri Mar 12 06:23:44 2021, Taras, Nishu, Chloe, Charlie, RUN, General, CD2, run56 screenshots at 06h15 10x
Screenshots attached
Fixed, e793s, Fri Mar 12 08:58:09 2021, Adrien, BEAM, Hardware, CD2, Beam is stopped 8h55 
Beam stopped to fix a leak on the accelerator. Intervention up to 4hours, maybe less.
Fixed, e793s, Fri Mar 12 09:52:01 2021, mugast (Sarah, Louis), OFFLINE, General, CD2, Offline analysis run up to 56 8am AngDisrtib.png3MeV_gamma.pngAWBA.png
1) A high energy gamma has been identified at 3505 keV by gating on 3-5 MeV range in excitation energy. This transition is unknown so far

2) preliminary angular distribution has been extracted for the p states(<1MeV) and the f states (3-5MeV) corrected from geometrical efficiency. Angular
Fixed, e793s, Fri Mar 12 09:55:30 2021, Franco, GRIT, General, CD2, MM5 square_shifted_theta.pngsquare_shifted_Z.png
The first plot attached has been done by artificially removing 7 deg in theta lab, just to see if the the kinematic lines of 47K(d,d) and 47K(p,p) can be
reproduced. Of course the energy losses are not optimized in this case but anyway the agreement seems nice.
In the second plot I moved MM5 forward (in z) by 17.5 mm, without any re-orientation in x and y. We should compare this position with the one measured
Fixed, e793s, Fri Mar 12 09:57:30 2021, Adrien, OTHER, Social, N/A, Lost phone in agata counting room 161C9D73-3ED8-49DE-A1EF-4ED9AA11C912.jpeg
Someone lost his/her phone in the agata counting room. Pictures attached.
Fixed, e793s, Fri Mar 12 10:07:29 2021, mugast, MECH, Hardware, , Leak 

https://www.hometree.co.uk/energy-advice/home-cover/common-water-leaks-and-how-to-fix-them.html
Fixed, e793s, Fri Mar 12 10:32:41 2021, OttoRun, RUN, General, CD2, Run57 
*************************
  [SIZE=3][B]Run  : 57[/B][/SIZE]
*************************
Fixed, e793s, Fri Mar 12 10:52:46 2021, Adrien, VAMOS, Hardware, N/A, Q pole trip in vamos 
Q-Pole tripped this night around 4am at the same time as the dipole but was switch on again only at 9am.
Ongoing, e793s, Fri Mar 12 12:58:10 2021, Emmanuel C, OFFLINE, General, , Gamma Gamma Analysis 7x
 