Fixed, e793s, Tue Mar 9 10:22:16 2021, mugast, DAQ, Hardware, N/A, U2M scaler configuration
|
U2M
1-FAG
2-OR MM-MG
3-OR AGATA
4-TRIG VAMOS
5-CATS CLEAN
6-DT && OR MM-MG
7-100 Hz
8-100 Hz & DT
9-MUVI1
10-MUVI2
11-MUVI3
12-MUVI4
15-CATS2 direct
16- FINGER (unused) |
Fixed, e793s, Tue Mar 9 10:47:12 2021, mugast, DAQ, Hardware, N/A, GMT config
|
GMT
1-MUVI1
2-MUVI2
3-MUVI3
4-
5-CATS2clean % (/10**4 for the moment)
6-VAMOS% (/10 for the moment)
7-MUST2% (/10 for the moment)
8-
9-
10-VAMOS
11-OR AGATA |
Fixed, e793s, Tue Mar 9 11:47:14 2021, Franco, RUN, General, N/A, TACS calibration 
|
Coefficients uploaded in MUGAST/e793s/calibTACS_e793s.cal (set offsets to 0 and kept only the slope) |
Fixed, e793s, Wed Mar 10 13:03:00 2021, OttoRun, RUN, General, 3-alpha, Run41
|
*************************
Run : 41
*************************
Start at 2021-03-10 12:58:41.805693
run 3 alpha
Stop at 2021-03-10 13:06:49.699879
Stop comment: |
Fixed, e793s, Wed Mar 10 13:09:12 2021, OttoRun, RUN, General, 3-alpha, Run42
|
*************************
Run : 42
*************************
Start at 2021-03-10 13:09:04.739262
run 3 alpha
Stop at 2021-03-10 13:30:31.317348
Stop comment: changing trigger |
Pinned, e793s, Wed Mar 10 13:10:14 2021, Adrien, BEAM, General, CD2, Kinematical line from Ti contamination 
|
In black the Kinematical line for states known to be populated strongly in 47Ti(d,p).
In blue range of the states of interrest.
The contamination is in a different region and should not cause any issue. |
Fixed, e793s, Wed Mar 10 13:33:31 2021, OttoRun, RUN, General, N/A, Run43
|
*************************
Run : 43
*************************
Start at 2021-03-10 13:33:01.346673
Agata or as trigger for testing before beam
Stop at 2021-03-10 13:55:37.322216
Stop comment: |
Fixed, e793s, Wed Mar 10 13:57:54 2021, OttoRun, RUN, General, N/A, Run45
|
*************************
Run : 45
*************************
Start at 2021-03-10 13:57:50.701600
Agata or as trigger for testing before beam
Stop at 2021-03-10 14:01:53.157232
Stop comment: |
Fixed, e793s, Wed Mar 10 14:43:14 2021, OttoRun, RUN, General, N/A, Run46
|
*************************
Run : 46
*************************
Start at 2021-03-10 14:42:50.365714
Test run for Professor Clement. Beam in the room.
Stop at 2021-03-10 16:02:30.981195
Stop comment: |
Fixed, e793s, Wed Mar 10 15:15:44 2021, Charlie, OTHER, General, , 48Ti Kinematics (additional)  
|
Supplementary to Adrien's kinematic calculations of 47Ti(d,p)48Ti, we have found a paper suggesting that by far the most strongly populated state in 48Ti is at 5.65 MeV. There is also a doublet of strong states at around 4.4 MeV, and two more strongly populated states at 6.06 and 6.33 MeV.
See attachment for the full table from P. D. Barnes (1965), Phys.Rev.138.B597.
Some quick CatKin models also show that a (theoretical) state at 7 MeV in 48Ti would almost perfectly overlap with the ground state of 48K. As such, when looking at the lab energy with the g.s. of 48K normalised to 0, we could expect to see these strongly populated 48Ti states at -0.67, -0.94, -1.35 and -2.6 MeV (for 6.3, 6.06, 5.65 and 4.4 MeV, respectively).
See the attached plot for kinematics of 47K(d,p)48K @ 0 MeV and 4 MeV, as well as 47Ti(d,p)48Ti @ 0 MeV, 5.65 MeV and the theoretical 7 MeV. Additionally, see a mock-up of the expected spectra from Wilton. |
Fixed, e793s, Wed Mar 10 16:07:43 2021, OttoRun, RUN, General, N/A, Run47
|
*************************
Run : 47
*************************
Start at 2021-03-10 16:07:22.660368
Beam in the room; restarting daq after recompiling the action
Stop at 2021-03-10 16:09:55.182936
Stop comment: stopping run to remove vamos% from trigger |
Fixed, e793s, Wed Mar 10 16:12:40 2021, OttoRun, RUN, General, Empty, Run48
|
*************************
Run : 48
*************************
Start at 2021-03-10 16:11:56.052849
Beam in the room; restarting daq after changing trigger.
Trigger are MUGAST/MM/CATS%
Stop at 2021-03-10 16:30:03.651340
Stop comment: stopping to remove cats% from trigger so we can set the timing |
Fixed, e793s, Wed Mar 10 16:31:50 2021, OttoRun, RUN, General, CD2, Run49
|
*************************
Run : 49
*************************
Start at 2021-03-10 16:31:31.923710
Beam in the room; restarting daq after changing trigger.
target: CD2 0.5mg
Trigger are MUGAST/MM
Stop at 2021-03-10 16:53:12.237279
Stop comment: stopping to change GMT windows |
Fixed, e793s, Wed Mar 10 17:00:06 2021, OttoRun, RUN, General, CD2, Run50
|
*************************
Run : 50
*************************
Start at 2021-03-10 16:59:44.368649
Beam in the room; restarting daq after changing trigger.
target: CD2 0.5mg
Trigger are MUGAST/MM
changing width of the FAG to 1us
Stop at 2021-03-10 17:12:21.612357
Stop comment: stopping to get in and change the cats delay |
Fixed, e793s, Wed Mar 10 17:25:22 2021, OttoRun, RUN, General, CD2, Run51
|
*************************
Run : 51
*************************
Start at 2021-03-10 17:24:45.316220
Beam in the room; restarting daq after changing trigger.
target: CD2 0.5mg
Trigger are MUGAST/MM
changed width of the FAG to 400ns
Removed extra 100ns delay from cats validation
Stop at 2021-03-10 18:14:26.996869
Stop comment: stop for VAMOS data analysis. Coherence check
Stop at 2021-03-10 20:46:36.348405
Stop comment: stopped the run to add cats% in the trigger |
Fixed, e793s, Wed Mar 10 18:22:01 2021, Taras, Nishu, Chloe, RUN, General, , status screenshot
|
|
Fixed, e793s, Wed Mar 10 19:23:37 2021, mugast, OFFLINE, General, CD2, Kinematics and Ex - RUN051 
|
Preliminary analysis results, Backward angles.
MM5 position are incorrect |
Pending, e793s, Wed Mar 10 20:36:19 2021, Nigel, BEAM, General, CD2, Beam centering - MUST2 hit pattern
|
We made a quick check of the beam centering by inspecting the MUST2 (forward angles) hit pattern (plot attached). It appears that the beam is probably somewhat off centre in the horizontal direction.
It has been decided to run overnight like this and then see with Bertrand if the centering can be improved (will need to send hit pattern spectrum to PCP in order for Bertam to do this).
 |
Fixed, e793s, Wed Mar 10 20:53:55 2021, OttoRun, RUN, General, CD2, Run52
|
*************************
Run : 52
*************************
Start at 2021-03-10 18:16:20.382279
Beam in the room; restarting daq after changing trigger.
target: CD2 0.5mg
Trigger are MUGAST/MM
changed width of the FAG to 400ns
Removed extra 100ns delay from cats validation |
Fixed, e793s, Wed Mar 10 21:02:03 2021, OttoRun, RUN, General, CD2, Run53
|
*************************
Run : 53
*************************
Start at 2021-03-10 21:00:45.001418
Production run.
Beam: 4.5e5 pps
target: CD2 0.5mg
Trigger are MUGAST/MM/CATS%
Stop at 2021-03-11 09:40:34.970341
Stop comment: run stopped to enter and check position 0 ATC6 trip |
|