MUST2 SAMURAI_2018 S3-LEB-LPC SUPERNEMO MUGAST EXPAND SCALP GALATRON HiCARI VELO
  MUST2, Page 45 of 48  Not logged in MUST2
Fixed, e738, Wed Jul 11 18:31:23 2018, Jacques, Didier, Louis, RUN, General, Cryo-LH2, Run 349 6x
Run 349

Start 18h22 Stop 18h47

========================================

Beam: 9C
2.3*10**5pps in CATS1
1.9*10**5pps in CATS2
3.1*10**5pps in CAVIAR
2uA of intensity of the primary beam


CATS1 670V 0.14 ľA
CATS2 650V 0.10 ľA

========================================

Pressure in CAVIAR has been changed from 20mbar to 10mbar because we lost the position correlation with respect to the TOF
Fixed, e738, Wed Jul 11 19:08:40 2018, Didier, Louis, RUN, General, Cryo-LH2, RUN 350 10x
Run 350

Start 19h00 Stop 19h11

========================================

Beam: 9C
2.1*10**5pps in CATS1
1.8*10**5pps in CATS2
1.5*10**5pps in CAVIAR
2uA of intensity of the primary beam


CATS1 670V 0.16 ľA
CATS2 650V 0.10 ľA => 2 over-current/min

========================================
Fixed, e738, Wed Jul 11 19:17:20 2018, Didier, Louis, RUN, General, Cryo-LH2, RUN 351 scaler_2018-07-11_19h20m33s.pngvisu_2018-07-11_19h21m57s.pngvisu_2018-07-11_19h22m00s.pngvisu_2018-07-11_19h22m58s.pngscaler_STOP_2018-07-11_19h57m00s.png
Run 351

Start 19h14 Stop 19h53

========================================

Beam: 9C
2.1*10**5pps in CATS1
1.8*10**5pps in CATS2
3.1*10**5pps in CAVIAR (10mbar 720V)
1.9uA of intensity of the primary beam


CATS1 670V 0.16 ľA
CATS2 650V 0.12 ľA => 2 over-current/min

========================================

Good efficiency of CAVIAR at 720V and 10mbar
Fixed, e738, Wed Jul 11 20:00:01 2018, Didier, Valérie, Louis, RUN, General, Cryo-LH2, RUN 352 7x
Run 352

Start 19h57 Stop 21h51

========================================

Beam: 9C

1.9*10**5pps in CATS1
1.7*10**5pps in CATS2
2.7*10**5pps in CAVIAR (10mbar 720V)
1.6uA of intensity of the primary beam


CATS1 670V 0.14 ľA
CATS2 650V 0.10 ľA

========================================

Oil troubles in the Ion source. Vacuum alarm stopped the beam. They call the astreinte

Can see gain decreasing of strip 9 in CATS1 Y
Fixed, e738, Wed Jul 11 21:55:23 2018, Daisuke, Didier, Valérie, Louis, RUN, General, Cryo-LH2, RUN 353 6x
Run 353

Start 21h50 Stop

========================================

Beam: 9C

1.9*10**5pps in CATS1
1.7*10**5pps in CATS2
2.8*10**5pps in CAVIAR (10mbar 720V)
1.8uA of intensity of the primary beam


CATS1 670V 0.14 ľA
CATS2 650V 0.10 ľA

========================================

HV and current stable
beam stable
Fixed, e738, Wed Jul 11 23:36:27 2018, Didier, Louis, Freddy, Shumpei, RUN, General, Cryo-LH2, RUN 354 scaler_2018-07-11_23h42m26s.pngvisu_2018-07-11_23h40m27s.pngvisu_2018-07-11_23h42m12s.pngvisu_2018-07-11_23h42m15s.pngvisu_2018-07-11_23h43m02s.png
Run 354

Start 23h33 Stop 1h37

Run stopped due to water leak alarm somewhere under investigation (call from PCP)

========================================

Beam: 9C

Large fluctuation of the beam intensity from 190kpps to few kpps

1.9*10**5pps in CATS1
1.7*10**5pps in CATS2
2.8*10**5pps in CAVIAR (10mbar 720V)
1.8uA of intensity of the primary beam


CATS1 670V 0.12 ľA
CATS2 650V 0.08 ľA

========================================

HV and current stable
Fixed, e738, Thu Jul 12 02:12:20 2018, Shumpei, Freddy, RUN, General, Cryo-LH2, RUN 355 7x
RUN 355

start: 2h04
stop: 4h22

12C primary (1.8 uA)
CATS1: 220 kHz
CATS2: 190 kHz
PL: 198 kHz
Fixed, e738, Thu Jul 12 04:40:32 2018, Shumpei, CATS, General, Cryo-LH2, Analysis with only one of the CATSs cats1.pngcats2.pngcats3.pngcats4.png
Analyzed data : run 0331
Used reaction : 7Be(p,d)6Be (ground state and 2+ state 1.6 MeV are mainly populated).

Method;
X and Y position on each CATS is compared with position on the target deduced by both CATSs. Assuming the beam profile is not changing, the correlation of these positions can by fit by linear function.
The position on the target can reconstructed with only one of the CATSs, with worse resolution. Beam angular spread seems rather small than angular deduced by only 1 CATS.
In terms of the excitation energy resolution,
sigma of the Subtraction of (both CATS Ex)-(only CATS1 Ex) ~ 0.53 MeV
sigma of the Subtraction of (both CATS Ex)-(only CATS2 Ex) ~ 0.32 MeV
Original estimated Ex resolution is ~ 1 MeV, so not so bad.
In terms of the background from the frame of the target cell, roughly can be removed by target position. Near the center part gate should be more secure.
Fixed, e738, Thu Jul 12 05:03:49 2018, Shumpei, Freddy, RUN, General, Cryo-LH2, RUN 356 7x
RUN 356

start: 4h24
stop: 6h39

12C primary : 1.8 uA
CATS1: 200 kHz
CATS2: 175 kHz
PL : 180 kHz
Fixed, e738, Thu Jul 12 07:05:53 2018, Shumpei, Freddy, Megumi, Valérie, RUN, General, Cryo-LH2, RUN 357 7x
RUN 357

start: 6h39
stop: 8h13
e748 Exxx 3,2G 12 juil. 08:13 /data/e748X/e755/acquisition/run/run_0357.dat.12-07-18_06h38m56s
12C primary : 2.0 uA
CATS1: 220 kHz
CATS2: 186 kHz
PL : 192 kHz
Fixed, e738, Thu Jul 12 07:43:25 2018, Shumpei, OFFLINE, General, Cryo-LH2, Analysis of 9C beam setting c9b8pd2.pngbe7li6pt.pngc9b8pt.png
Used data : run0312-0355

For (p,t) reaction, the value of the mass for N=1 isotone is taken from proposal, so it can be shifted.
3He coincidence gate is applied to remove the beam triton background.
Fixed, e738, Thu Jul 12 08:16:21 2018, Daisuke, Megumi, Valérie, RUN, General, Cryo-LH2, RUN 358 20x
RUN 358
start: 8h14 stop: 9h48

e748 Exxx 3,3G 12 juil. 09:49 /data/e748X/e755/acquisition/run/run_0358.dat.12-07-18_08h12m26s


12C primary : 1.95 uA
CATS1: 224 kHz ; CATS2: 194 kHz
PL : 199 kHz

CATS1 670 V I ~ 0.16 ľA ; CATS2 650V I ~ 0.12V
Efficiencies estimated from the integrals in the plots IC_dE1_TCATS1HF
cf run358_ICdeTcatsHFtot.png run358_ICdeTcatsHFeff.png
CATS 1: (2.8 10**4)/(3.1 10**4) =0.90 -->90% ; CATS2 (2.7 10**4)/(3.06 10**4)==> 88%
Fixed, e738, Thu Jul 12 09:52:07 2018, Daisuke, Megumi, Valérie, RUN, General, Cryo-LH2, RUN 359 6x
RUN 359

start: 9h48 stop: 11h25
748 Exxx 3,2G 12 juil. 11:25 /data/e748X/e755/acquisition/run/run_0359.dat.12-07-18_09h48m08s
12C primary : 1.98 uA
CATS1: 230 kHz ; CATS2: 198 kHz
PL : 205 kHz

CATS1 670 V I ~ 0.16 ľA ; CATS2 650V I ~ 0.12V
Fixed, e738, Thu Jul 12 11:28:46 2018, Daisuke, Megumi, Valérie, RUN, General, Cryo-LH2, RUN 360 10x
RUN 360
e748 Exxx 3,4G 12 juil. 13:08 /data/e748X/e755/acquisition/run/run_0360.dat.12-07-18_11h24m44s
start: 11h25 stop: 13h08
12C primary : 1.95 uA
CATS1: 230 kHz ; CATS2: 198 kHz
PL : 205 kHz

CATS1 670 V I ~ 0.16 ľA ; CATS2 650V I ~ 0.12V
Stable conditions for beam and CATS during the run.
Series of plots for the raw spectra of CATS1 strips.
Fixed, e738, Thu Jul 12 13:09:14 2018, Daisuke, Megumi, Valérie, RUN, General, Cryo-LH2, RUN 361 6x
RUN 361
e748 Exxx 3,5G 12 juil. 15:01 /data/e748X/e755/acquisition/run/run_0361.dat.12-07-18_13h07m40s
start: 13h08 stop: 14h59
12C primary : 1.8 uA
CATS1: 200 kHz ; CATS2: 175 kHz
Plast : 178 kHz

CATS1 670 V, I ~ 0.14 ľA ; CATS2 650V, I ~ 0.10V sometimes up Ovc to 0.38 ľA but rather stable.
Fixed, e738, Thu Jul 12 15:07:43 2018, Daisuke, Louis, Marlčne, Megumi, Valérie, RUN, General, Cryo-LH2, RUN 362-TRIGGER TESTS 11x
RUN 362 WITH CHANGE OF TRIGGERS FOR TESTS see below
e748 Exxx 1,7G 12 juil. 16:09 /data/e748X/e755/acquisition/run/run_0362.dat.12-07-18_15h08m50s
start: 15h08 stop: 16h08
12C primary : between 1.7 and 1.9 uA
CATS1: 200 kHz ; CATS2: 175 kHz
Plast : 178 kHz FAG ~ 650/s

CATS1 670 V I ~ 0.14 ľA ; CATS2 650V I ~ 0.10V sometimes up Ovc to 0.38 ľA but rather stable.

The triggers can be seen on Run362_TriggerMMallCats.png
There are: IN10- CATS1div and IN11 -CATS2div, IN16 Plastic %
IN12 and IN14.

NB: the entry IN12 noted "CATS" in the snapshot was MM2all div, with div =10
In Gatconfmaster the value is 2**(12-1) = 2048.
The "IN14" trigger input is:
MM2all*CATS (hardware coincidence between MUST2 and CATS) in IN14
GMT trigger in GATCONFmaster : 2**(14-1) = 2**13 = 8192.
Fixed, e738, Thu Jul 12 15:27:56 2018, daiuske, MUST2, General, N/A, MUST2*CATS coincidence trigger 2018-07-09_message_adrien.pdfScreenshot_2018-07-09_()_-_document.png
Message from Adrien.
Fixed, e738, Thu Jul 12 16:22:43 2018, Frank, Louis, RUN, General, Cryo-LH2, RUN 363 10x
RUN 363

start: 16h09 stop: 18h10
12C primary I : between 1.7 and 1.8 uA
CATS1: 194 kHz ; CATS2: 170 kHz
Plast : 170 kHz
FAG ~ 650/s

CATS1 670 V I ~ 0.12 ľA ; CATS2 650V I ~ 0.10V sometimes up Ovc to 0.38 ľA but rather stable.
Fixed, e738, Thu Jul 12 18:12:33 2018, Frank, Louis, RUN, General, Cryo-LH2, RUN 364 12x
RUN 364

start: 18h11 stop: 20h45

12C primary I : 1.8 uA
CATS1: 215 kHz ; CATS2: 171 kHz
Plast : 190 kHz
FAG ~ 730/s

CATS1 670 V I ~ 0.14 ľA ; CATS2 650V I ~ 0.10V
Fixed, e738, Thu Jul 12 20:47:32 2018, Frank, Louis, RUN, General, Cryo-LH2, RUN 365 10x
RUN 365

start: 20h46 stop: 22h43

12C primary I : 1.8 uA
CATS1: 200 kHz ; CATS2: 185 kHz
Plast : 177 kHz
FAG ~ 755/s

CATS1 670 V I ~ 0.14 ľA ; CATS2 650V I ~ 0.10V

ELOG Home Page