Fixede748 Thu Jul 6 01:26:15 2017 Franck et ValérianCHIOHardwareN/AUPDATE : CHIO's electronic scheme (valid from run 293)
Since Run 293 inspection line of NUMEXO 2 has been used as input signal of CAEN digitizer.
Attachment 1: Schema_electronique_CHIO.pdf
Schema_electronique_CHIO.pdf
Fixede748 Wed Jun 7 18:03:02 2017 FranckOTHERHardware LPC electronics
Caen N568B: 509, 490
Ortec TAC: 1102, 1479, 1480, 1481
Lecroy GDG222: E2557, 01175C, 831
Lecroy Coinc 465: E2229
Lecroy FIFO 429A: E2631A, E2600, 98971, 01175B
Lecroy NIM-ECL 4616: E2559, E2321, 82791
Quad CFD 7174: 042, 046, 047, 051, 117, 206
Octal FAN-OUT 364: E2315
QDC VXI 3214 410pC
Wiener NIM Crate 600 W
Fixede748 Mon Jul 3 19:43:16 2017 FranckCHIOHardwareN/ACHIO logic signals for TAC and CAEN digitizer
STOP of CHIO CAEN digitizer = VAL AND Delayed CHIO (Delay = 700 ns). Before run 217, the CHIO was not delayed.
STOP of TAC PLASTval-CHIO = CHIO without delay. Before run 217 it was delayed CHIO.
Fixede755 Sun Jun 24 19:51:09 2018 Faïrouz, daisukeMUST2SoftwareN/AMUST2 threshold from 1 MeV to 0.4 MeV
It was found that the energy threshold of the strips was as high as 1 MeV. This threshold setting was chosen for the calibration and was never set back to the nominal threshold (0.4 MeV) for experiments.

Lowered to 0.4 MeV.

Note that due to the low energy threshold, triton of energies higher than 70 MeV were partially rejected during the measurement of 40Ca(p,t).
Attachment 1: das_2018-06-24_19h33m36s.png
das_2018-06-24_19h33m36s.png
Attachment 2: das_2018-06-24_19h49m33s.png
das_2018-06-24_19h49m33s.png
Fixede744 Tue May 22 19:36:50 2018 Fairouz, ValérieMUST2SoftwareN/ARun #359 Calimero T1-T4 strips X
Run #359
amplitude of the gene is now set to 10 MeV
Time Calibrator Calimero stripsX T1to T4 640ns period 20ns
Attachment 1: CalimeroRunXTampli10MeV.png
CalimeroRunXTampli10MeV.png
Attachment 2: PlotStripsXTcalimero.png
PlotStripsXTcalimero.png
Attachment 3: PlotStripsT1XT67calim1.png
PlotStripsT1XT67calim1.png
Attachment 4: PlotStripsT2XT27calim1.png
PlotStripsT2XT27calim1.png
Attachment 5: PlotStripsT4XT28calim.png
PlotStripsT4XT28calim.png
Attachment 6: PlotStripsT4XT44calim.png
PlotStripsT4XT44calim.png
Attachment 7: PlotEXPulserProbT4.png
PlotEXPulserProbT4.png
Attachment 8: PlotStripsT1toT4XT_run359.png
PlotStripsT1toT4XT_run359.png
Fixede744 Tue May 22 20:06:15 2018 Fairouz, Valerie, edited by Iulian MegumiMUST2SoftwareN/ARun #360 Calimero T1-T4 strips Y
Started run #360
calimero stripsYT T1 to T4 640 ns; period 20 ns
amplitude pulser 10 MeV
There was a problem on T2 as the channel 2 on GMT MASTER was set on TTL.
Attachment 1: Calimero_GMTproblem.png
Calimero_GMTproblem.png
Fixede744 Tue May 22 13:40:03 2018 Fairouz ValerieMUST2SoftwareN/ARun #356 Calimero T1-T4 strips Y
Run #356
Time Calibrator Calimero stripYT T1to T4 640ns period 20ns
Fixede744 Mon May 28 20:33:39 2018 E744- evening shift LISE+e744 teams (edit Iulan, Valérie)RUNGeneralCH2BEAM AGAIN RUN 2100 Tuning
See plot of the Must2 impacts, Wien filter set at +/-0.8kV
Beam on CATS 1.2 10**5 pps
CH2 183 µm
Div as before
Attachment 1: beam_spot_2100_end.png
beam_spot_2100_end.png
Fixede744 Mon May 28 20:38:21 2018 E744- evening shift LISE+MUST2 teams (edit Valérie)RUNGeneralCH2 RUN 2101 DATA target 4
run #2101
start @20h27
stop @22h20
target 4

Evening shift team:
LISE and E744 François, Iulan, Valérian, Louis, Jean-Charles, Marlete A., Pierre D., Simon G., Valérie L.
E744
Beam on CATS 1.2 10**5 pps
CH2 183 µm // ERROR ?? this should be 100um
Div as before
All Triggers in GMT (without LISE)
Attachment 1: ScalersDuringRun2101.png
ScalersDuringRun2101.png
Attachment 2: HV_EXL_28May18.png
HV_EXL_28May18.png
Attachment 3: TACduringRun2101.png
TACduringRun2101.png
Attachment 4: TMM5stripsXYETrun2101.png
TMM5stripsXYETrun2101.png
Attachment 5: MM1toMM4strYE_run2101.png
MM1toMM4strYE_run2101.png
Attachment 6: MM1toMM4strXT_run2101.png
MM1toMM4strXT_run2101.png
Attachment 7: MM1toMM4strYT_run2101.png
MM1toMM4strYT_run2101.png
Attachment 8: MM1toMM4impactsMM5_Run2101.png
MM1toMM4impactsMM5_Run2101.png
Attachment 9: TACcoincMMppt_Run2101.png
TACcoincMMppt_Run2101.png
Attachment 10: HV_MUST2duringRun2101.png
HV_MUST2duringRun2101.png
Attachment 11: EXLCsiPads_Run2101.png
EXLCsiPads_Run2101.png
Attachment 12: Scaler_end_Run2101.png
Scaler_end_Run2101.png
Fixede744 Mon May 28 16:32:38 2018 E744- ValérieDAQGeneralN/ADAS configuration files-References
Attachment 1: ConfigGMTexp744Mon28th.png
ConfigGMTexp744Mon28th.png
Attachment 2: ConfigMUVICastelStandardA.png
ConfigMUVICastelStandardA.png
Attachment 3: ConfigMUVICastelStandardB.png
ConfigMUVICastelStandardB.png
Attachment 4: MM5_thresholdAt992keV.png
MM5_thresholdAt992keV.png
Attachment 5: MM1_thresholdAt1MeV.png
MM1_thresholdAt1MeV.png
Attachment 6: ConfigE744actionGanlx14b.png
ConfigE744actionGanlx14b.png
Attachment 7: ConfigE744actionGanlx1b.png
ConfigE744actionGanlx1b.png
Attachment 8: ConfigE744InterfaceU3M.png
ConfigE744InterfaceU3M.png
Attachment 9: ConfigE744paramU2M.png
ConfigE744paramU2M.png
Attachment 10: ConfigE774CentrumMaster.png
ConfigE774CentrumMaster.png
Attachment 11: ConfigMUVICastelMufeeYStd.png
ConfigMUVICastelMufeeYStd.png
Attachment 12: ConfigMUVICastelMufeeXE744.png
ConfigMUVICastelMufeeXE744.png
Attachment 13: ConfigE744Muvi1B.png
ConfigE744Muvi1B.png
Attachment 14: ConfigE744Muvi1A.png
ConfigE744Muvi1A.png
Attachment 15: MM1MufeeYtemp5deg.png
MM1MufeeYtemp5deg.png
Fixede744 Mon May 28 18:27:45 2018 E744- ValérieDAQGeneralN/AHigh Voltages and intensities on MUST2
Check regularly the HT on the MUST2.
NB: without beam the current on Telescope 4 is high, between 9 and 11 µA. see snapshot.
NB: The Ioset was increased at 20 µA on Friday 25th (cf Id entry=490) to avoid trips on this telescope due to strong intensity fluctuations due to the beam.
Attachment 1: HT_MUST2withoutBeam28may18.png
HT_MUST2withoutBeam28may18.png
Fixede738 Wed Jul 11 20:00:01 2018 Didier, Valérie, LouisRUNGeneralCryo-LH2RUN 352
Run 352

Start 19h57 Stop 21h51

========================================

Beam: 9C

1.9*10**5pps in CATS1
1.7*10**5pps in CATS2
2.7*10**5pps in CAVIAR (10mbar 720V)
1.6uA of intensity of the primary beam


CATS1 670V 0.14 µA
CATS2 650V 0.10 µA

========================================

Oil troubles in the Ion source. Vacuum alarm stopped the beam. They call the astreinte

Can see gain decreasing of strip 9 in CATS1 Y
Attachment 1: scaler_2018-07-11_20h02m50s.png
scaler_2018-07-11_20h02m50s.png
Attachment 2: visu_2018-07-11_20h02m37s.png
visu_2018-07-11_20h02m37s.png
Attachment 3: visu_2018-07-11_20h02m41s.png
visu_2018-07-11_20h02m41s.png
Attachment 4: visu_2018-07-11_20h02m48s.png
visu_2018-07-11_20h02m48s.png
Attachment 5: visu_2018-07-11_20h03m03s.png
visu_2018-07-11_20h03m03s.png
Attachment 6: visu_2018-07-11_21h02m10s.png
visu_2018-07-11_21h02m10s.png
Attachment 7: visu_2018-07-11_21h24m18s.png
visu_2018-07-11_21h24m18s.png
Fixede738 Wed Jul 11 23:36:27 2018 Didier, Louis, Freddy, ShumpeiRUNGeneralCryo-LH2RUN 354
Run 354

Start 23h33 Stop 1h37

Run stopped due to water leak alarm somewhere under investigation (call from PCP)

========================================

Beam: 9C

Large fluctuation of the beam intensity from 190kpps to few kpps

1.9*10**5pps in CATS1
1.7*10**5pps in CATS2
2.8*10**5pps in CAVIAR (10mbar 720V)
1.8uA of intensity of the primary beam


CATS1 670V 0.12 µA
CATS2 650V 0.08 µA

========================================

HV and current stable
Attachment 1: scaler_2018-07-11_23h42m26s.png
scaler_2018-07-11_23h42m26s.png
Attachment 2: visu_2018-07-11_23h40m27s.png
visu_2018-07-11_23h40m27s.png
Attachment 3: visu_2018-07-11_23h42m12s.png
visu_2018-07-11_23h42m12s.png
Attachment 4: visu_2018-07-11_23h42m15s.png
visu_2018-07-11_23h42m15s.png
Attachment 5: visu_2018-07-11_23h43m02s.png
visu_2018-07-11_23h43m02s.png
Fixede738 Wed Jul 11 19:08:40 2018 Didier, LouisRUNGeneralCryo-LH2RUN 350
Run 350

Start 19h00 Stop 19h11

========================================

Beam: 9C
2.1*10**5pps in CATS1
1.8*10**5pps in CATS2
1.5*10**5pps in CAVIAR
2uA of intensity of the primary beam


CATS1 670V 0.16 µA
CATS2 650V 0.10 µA => 2 over-current/min

========================================
Attachment 1: scaler_2018-07-11_19h12m25s.png
scaler_2018-07-11_19h12m25s.png
Attachment 2: visu_2018-07-11_19h10m55s.png
visu_2018-07-11_19h10m55s.png
Attachment 3: visu_2018-07-11_19h11m00s.png
visu_2018-07-11_19h11m00s.png
Attachment 4: visu_2018-07-11_19h11m06s.png
visu_2018-07-11_19h11m06s.png
Attachment 5: visu_2018-07-11_19h11m24s.png
visu_2018-07-11_19h11m24s.png
Attachment 6: visu_2018-07-11_19h11m48s.png
visu_2018-07-11_19h11m48s.png
Attachment 7: visu_2018-07-11_19h12m04s.png
visu_2018-07-11_19h12m04s.png
Attachment 8: visu_2018-07-11_19h12m12s.png
visu_2018-07-11_19h12m12s.png
Attachment 9: visu_2018-07-11_19h12m22s.png
visu_2018-07-11_19h12m22s.png
Attachment 10: visu_2018-07-11_19h12m50s.png
visu_2018-07-11_19h12m50s.png
Fixede738 Wed Jul 11 19:17:20 2018 Didier, LouisRUNGeneralCryo-LH2RUN 351
Run 351

Start 19h14 Stop 19h53

========================================

Beam: 9C
2.1*10**5pps in CATS1
1.8*10**5pps in CATS2
3.1*10**5pps in CAVIAR (10mbar 720V)
1.9uA of intensity of the primary beam


CATS1 670V 0.16 µA
CATS2 650V 0.12 µA => 2 over-current/min

========================================

Good efficiency of CAVIAR at 720V and 10mbar
Attachment 1: scaler_2018-07-11_19h20m33s.png
scaler_2018-07-11_19h20m33s.png
Attachment 2: visu_2018-07-11_19h21m57s.png
visu_2018-07-11_19h21m57s.png
Attachment 3: visu_2018-07-11_19h22m00s.png
visu_2018-07-11_19h22m00s.png
Attachment 4: visu_2018-07-11_19h22m58s.png
visu_2018-07-11_19h22m58s.png
Attachment 5: scaler_STOP_2018-07-11_19h57m00s.png
scaler_STOP_2018-07-11_19h57m00s.png
Fixede738 Wed Jul 11 13:24:34 2018 Daisuke,CATS team: Séb, Thom ; Franck, Pierre, ValérieRUNGeneralCryo-LH2Runs 344-345
Wed 11 July 2018
run 344 start 12h43 ; stop 13h03
e748 Exxx 900M 11 juil. 13:03 /data/e748X/e755/acquisition/run/run_0344.dat.11-07-18_12h43m33s
run 345 start 13h02 ; stop 14h49
e748 Exxx 3,2G 11 juil. 14:49 /data/e748X/e755/acquisition/run/run_0345.dat.11-07-18_13h02m22s
- - - - - - - - - - - - - - - - - -- - - - - - - - -- - - - - - - - -- - - - - - - - -
change of HV on CATS during Run 345: from 650V to 670V
Current on CATS2 is fluctuating (from 0.12 µA up to 0.6 µA) at oscilloscope, signals remain correct.
At 670V it is better for CATS2 efficiency
See plots : run345_EnergyChioRawTsdiff.png and run345_correlDeIChiotofCatsHF.png
Integral for IC is 8075; integral of the physical events in IC DE versus TOF CATS1 is 7548; for CATS2: integral 7044.
We have a rough estimate of CATS efficiencies: 7548/8075= 93%, for CATS2 87%.
The counting rates on CATS have closer values (at 650V, CATS2 is at 130 k pps; at 670V rate is 170k pps)
CATS1: 190k pps
CATS2: 170k pps
Plastic: 175k pps

Attachment 1: run345_scalersAt13h18.png
run345_scalersAt13h18.png
Attachment 2: run345_HVcats.png
run345_HVcats.png
Attachment 3: run345_correlDeIChiotofCatsHF.png
run345_correlDeIChiotofCatsHF.png
Attachment 4: run345_EnergyChioRawTsdiff.png
run345_EnergyChioRawTsdiff.png
Attachment 5: run345_BeamTracks.png
run345_BeamTracks.png
Attachment 6: run345_CatsStrQcal.png
run345_CatsStrQcal.png
Attachment 7: run345_CatsStrQRaw.png
run345_CatsStrQRaw.png
Attachment 8: run345_DCNumexoXY.png
run345_DCNumexoXY.png
Attachment 9: run345_MMimpacts.png
run345_MMimpacts.png
Attachment 10: run345_ICNumexo0deg.png
run345_ICNumexo0deg.png
Attachment 11: run345_TcatsCaviar.png
run345_TcatsCaviar.png
Attachment 12: run345_TCatsPlast.png
run345_TCatsPlast.png
Fixede755 Tue Jun 26 09:01:23 2018 Daisuke, Takeshi, Yorick, ValérieRUNGeneralCryo-LH2RUN 140
Run 140 start: 8h55 ; stop: 9h59
748 Exxx 3348489513 26 juin 09:59 /data/e748X/e755/acquisition/run/run_0140.dat.26-06-18_08h55m32s
The Csi Mate were put on the trigger again "ENABLE" in the DAS. see snapshot DAS_MUVIenableMateCsI.png

Trigger: all MM + CATS DIV
Dead time between 16 to 35%
Beam= 3.0x10**5 pps at 9h06 Run140_scalersAt9h06.png fluctuating [cf scalers at 9h01 (0) Run140_scalersAt9h01.png]

Slits (summary):
FH31 +/- 4mm ; FH43 ++/-5mm ; FV43 +/-1 4.1 mm
Slits 61 and 62 opned. FV61 +/-17.9 mm; FH61 -22;+18.2 mm
FH62 +/-15mm ; FV62 +/-18 mm
Attachment 1: Run140_scalersAt9h01.png
Run140_scalersAt9h01.png
Attachment 2: DAS_MUVIenableMateCsI.png
DAS_MUVIenableMateCsI.png
Attachment 3: Run140_scalersAt9h06.png
Run140_scalersAt9h06.png
Attachment 4: Run140_CATSTrajectories.png
Run140_CATSTrajectories.png
Attachment 5: CATS_TELESCOPE_M2.png
CATS_TELESCOPE_M2.png
Attachment 6: Run140_CATSbeam.png
Run140_CATSbeam.png
Attachment 7: Run140_CorrelICdEtofCats.png
Run140_CorrelICdEtofCats.png
Attachment 8: Run140_CorrelICdEtofCatsCaviar.png
Run140_CorrelICdEtofCatsCaviar.png
Attachment 9: Run140_CorrelICdEtofCatsCaviarZoom.png
Run140_CorrelICdEtofCatsCaviarZoom.png
Attachment 10: Run140_DCnumewoXYphys.png
Run140_DCnumewoXYphys.png
Attachment 11: Run140DCnumexoEraw.png
Run140DCnumexoEraw.png
Attachment 12: Run140ICenergyRaw.png
Run140ICenergyRaw.png
Attachment 13: Run140_ICnumewoErawTdiff.png
Run140_ICnumewoErawTdiff.png
Attachment 14: Run140_ICnumewoErawTdiff.png
Run140_ICnumewoErawTdiff.png
Attachment 15: Run140npScalers.png
Run140npScalers.png
Attachment 16: Run140plasticsQTcats.png
Run140plasticsQTcats.png
Attachment 17: Run140tacCatsHF.png
Run140tacCatsHF.png
Attachment 18: Run140_tacCatsHFcaviar.png
Run140_tacCatsHFcaviar.png
Attachment 19: Run140_TriggerMaster.png
Run140_TriggerMaster.png
Attachment 20: Run140_CatsStrXYQraw.png
Run140_CatsStrXYQraw.png
Attachment 21: Run140_CatsStrXYQCAL.png
Run140_CatsStrXYQCAL.png
Fixede738 Sun Jul 8 21:50:58 2018 Daisuke, Takeshi, ValérieRUNGeneralCryo-LH2RUN 297
Run 297 start 21h51 (8th July) stop at 0h (9th July)
e748 Exxx 3,0G 9 juil. 00:00 run_0297.dat.08-07-18_21h50m55s
MISSING STRIP, Y12 of CATS1 since run 296. see run297_CATSQRaw.png
CATS 1 640V I ~ 0.14 µA
CATS2 670V I ~ 0.14 µA
Beam 10C around 9. 10**4 and 10**5/s
Dead time between 7 and 13%
Attachment 1: run297_ScalersAt21h52.png
run297_ScalersAt21h52.png
Attachment 2: run297_TcatsHF.png
run297_TcatsHF.png
Attachment 3: run297_TcatsPlast.png
run297_TcatsPlast.png
Attachment 4: run297_BeamTracks.png
run297_BeamTracks.png
Attachment 5: run297_MMImpact.png
run297_MMImpact.png
Attachment 6: run297_MMStrxYEcal.png
run297_MMStrxYEcal.png
Attachment 7: run297_MM5to8StrxYEcal.png
run297_MM5to8StrxYEcal.png
Attachment 8: run297_CATSQCal.png
run297_CATSQCal.png
Attachment 9: run297_CATSQRaw.png
run297_CATSQRaw.png
Attachment 10: run297_TplastCats.png
run297_TplastCats.png
Attachment 11: run298_DCnumexoeRaw.png
run298_DCnumexoeRaw.png
Attachment 12: run297_ICdeTcatsHF.png
run297_ICdeTcatsHF.png
Attachment 13: run297_ICNumExoERaw_TSdiff.png
run297_ICNumExoERaw_TSdiff.png
Attachment 14: run297_IMM1to8StrxTraw.png
run297_IMM1to8StrxTraw.png
Attachment 15: run297_MM1to6CsiEdePID.png
run297_MM1to6CsiEdePID.png
Fixede738 Sun Jul 8 17:59:12 2018 Daisuke, Takeshi, ValérieRUNGeneralCryo-LH2RUN 295
Run 295 start 17h52 stop at 19h52
Beam stop occurred during 19h39 and 19h42 (alarm at the machine)

e748 Exxx 3,0G 8 juil. 19:53 run_0295.dat.08-07-18_17h52m05s

HV for CATS 1 put back at 640V. I ~ 0.12 to 0.14 µA
CATS2 670V I ~ 0.12 µA
Beam 10C around 10**5/s
Dead time between 6 and 13%
Attachment 1: run295ScalersAt17h59.png
run295ScalersAt17h59.png
Attachment 2: run295Beamtracks.png
run295Beamtracks.png
Attachment 3: run295_CATSQRaw.png
run295_CATSQRaw.png
Attachment 4: visu_2018-07-08_19h09m08s.png
visu_2018-07-08_19h09m08s.png
Attachment 5: visu_2018-07-08_19h09m13s.png
visu_2018-07-08_19h09m13s.png
Attachment 6: visu_2018-07-08_19h09m15s.png
visu_2018-07-08_19h09m15s.png
Attachment 7: visu_2018-07-08_19h09m18s.png
visu_2018-07-08_19h09m18s.png
Attachment 8: visu_2018-07-08_19h09m20s.png
visu_2018-07-08_19h09m20s.png
Attachment 9: visu_2018-07-08_19h09m23s.png
visu_2018-07-08_19h09m23s.png
Attachment 10: visu_2018-07-08_19h09m25s.png
visu_2018-07-08_19h09m25s.png
Attachment 11: visu_2018-07-08_19h09m27s.png
visu_2018-07-08_19h09m27s.png
Attachment 12: visu_2018-07-08_19h09m30s.png
visu_2018-07-08_19h09m30s.png
Attachment 13: visu_2018-07-08_19h09m32s.png
visu_2018-07-08_19h09m32s.png
Attachment 14: visu_2018-07-08_19h09m35s.png
visu_2018-07-08_19h09m35s.png
Attachment 15: visu_2018-07-08_19h09m37s.png
visu_2018-07-08_19h09m37s.png
Attachment 16: visu_2018-07-08_19h09m40s.png
visu_2018-07-08_19h09m40s.png
Attachment 17: visu_2018-07-08_19h09m42s.png
visu_2018-07-08_19h09m42s.png
Attachment 18: visu_2018-07-08_19h09m45s.png
visu_2018-07-08_19h09m45s.png
Attachment 19: visu_2018-07-08_19h09m48s.png
visu_2018-07-08_19h09m48s.png
Attachment 20: visu_2018-07-08_19h09m51s.png
visu_2018-07-08_19h09m51s.png
Attachment 21: visu_2018-07-08_19h09m54s.png
visu_2018-07-08_19h09m54s.png
Attachment 22: visu_2018-07-08_19h09m57s.png
visu_2018-07-08_19h09m57s.png
Attachment 23: visu_2018-07-08_19h10m00s.png
visu_2018-07-08_19h10m00s.png
Attachment 24: visu_2018-07-08_19h10m03s.png
visu_2018-07-08_19h10m03s.png
Attachment 25: visu_2018-07-08_19h10m06s.png
visu_2018-07-08_19h10m06s.png
Attachment 26: visu_2018-07-08_19h10m09s.png
visu_2018-07-08_19h10m09s.png
Fixede738 Sun Jul 8 20:00:42 2018 Daisuke, Takeshi, ValérieRUNGeneralCryo-LH2RUN 296 +(on-line) eff of CATS
Run 296 start 19h52 stop at 21h51

e748 Exxx 3,1G 8 juil. 21:51 run_0296.dat.08-07-18_19h52m46s

MISSING STRIP, Y12 of CATS1, during the run, see plots Run296_CATS_Qraw.png and Run296_CATS_Qcal.png.
CATS 1 640V I ~ 0.16 µA
CATS2 670V I ~ 0.14 µA
Beam 10C around 10**5/s
Dead time between 7 and 13%

Tests [V.lx) to be checked>>>] Online checkings of CATS efficiencies.
note that the Plast cannot be used directly for the control of CATS efficiencies in the online plots: Run296_plotPlastTcats.png
Plastics is counting nearly 65% more than CATS (cf Scalers +snapshot below zoomed on physical peaks). The Plastics also include secondary reactions and betas.

The correlation plots between the ionization chamber and the T_CATS_HF can be used, with suppression of the plot underflows. See plot examples.
In ICNumexo0_energy_Raw the integral is 8552. [Run296_ICenergyRawZoom.png]
The plot integrals are 7718 and 7841 for CATS1 and 2. [Run296_plotCorrelICCats.png]
The corresponding efficiencies are 90% and 92% for CATS1 and CATS2 (7718/8552 ~ 0.90 and 7841/8552 ~ 0.92)
Attachment 1: run296_scalers.png
run296_scalers.png
Attachment 2: Run296_plotPlastTcats.png
Run296_plotPlastTcats.png
Attachment 3: Run296_ICenergyRawZoom.png
Run296_ICenergyRawZoom.png
Attachment 4: Run296_plotCorrelICCats.png
Run296_plotCorrelICCats.png
Attachment 5: Run296_scalersAt20h50.png
Run296_scalersAt20h50.png
Attachment 6: Run296_CATS_Qraw.png
Run296_CATS_Qraw.png
Attachment 7: Run296_CATS_Qcal.png
Run296_CATS_Qcal.png
Attachment 8: Run296BeamTracks.png
Run296BeamTracks.png
Attachment 9: run296_EDE_Must2PID.png
run296_EDE_Must2PID.png
Attachment 10: run296_EDE_Must2PIDzoom.png
run296_EDE_Must2PIDzoom.png
Attachment 11: run296_EDE_Must2PIDzoomPdt.png
run296_EDE_Must2PIDzoomPdt.png