Fixed | e748 |
Thu Jul 6 01:26:15 2017 |
Franck et Valérian | CHIO | Hardware | N/A | UPDATE : CHIO's electronic scheme (valid from run 293) |
Since Run 293 inspection line of NUMEXO 2 has been used as input signal of CAEN digitizer. |
Fixed | e748 |
Wed Jun 7 18:03:02 2017 |
Franck | OTHER | Hardware | | LPC electronics |
Caen N568B: 509, 490
Ortec TAC: 1102, 1479, 1480, 1481
Lecroy GDG222: E2557, 01175C, 831
Lecroy Coinc 465: E2229
Lecroy FIFO 429A: E2631A, E2600, 98971, 01175B
Lecroy NIM-ECL 4616: E2559, E2321, 82791
Quad CFD 7174: 042, 046, 047, 051, 117, 206
Octal FAN-OUT 364: E2315
QDC VXI 3214 410pC
Wiener NIM Crate 600 W |
Fixed | e748 |
Mon Jul 3 19:43:16 2017 |
Franck | CHIO | Hardware | N/A | CHIO logic signals for TAC and CAEN digitizer |
STOP of CHIO CAEN digitizer = VAL AND Delayed CHIO (Delay = 700 ns). Before run 217, the CHIO was not delayed.
STOP of TAC PLASTval-CHIO = CHIO without delay. Before run 217 it was delayed CHIO. |
Fixed | e755 |
Sun Jun 24 19:51:09 2018 |
Faïrouz, daisuke | MUST2 | Software | N/A | MUST2 threshold from 1 MeV to 0.4 MeV |
It was found that the energy threshold of the strips was as high as 1 MeV. This threshold setting was chosen for the calibration and was never set back to the nominal threshold (0.4 MeV) for experiments.
Lowered to 0.4 MeV.
Note that due to the low energy threshold, triton of energies higher than 70 MeV were partially rejected during the measurement of 40Ca(p,t). |
Fixed | e744 |
Tue May 22 19:36:50 2018 |
Fairouz, Valérie | MUST2 | Software | N/A | Run #359 Calimero T1-T4 strips X |
Run #359
amplitude of the gene is now set to 10 MeV
Time Calibrator Calimero stripsX T1to T4 640ns period 20ns |
Fixed | e744 |
Tue May 22 20:06:15 2018 |
Fairouz, Valerie, edited by Iulian Megumi | MUST2 | Software | N/A | Run #360 Calimero T1-T4 strips Y |
Started run #360
calimero stripsYT T1 to T4 640 ns; period 20 ns
amplitude pulser 10 MeV
There was a problem on T2 as the channel 2 on GMT MASTER was set on TTL. |
Fixed | e744 |
Tue May 22 13:40:03 2018 |
Fairouz Valerie | MUST2 | Software | N/A | Run #356 Calimero T1-T4 strips Y |
Run #356
Time Calibrator Calimero stripYT T1to T4 640ns period 20ns |
Fixed | e744 |
Mon May 28 20:33:39 2018 |
E744- evening shift LISE+e744 teams (edit Iulan, Valérie) | RUN | General | CH2 | BEAM AGAIN RUN 2100 Tuning |
See plot of the Must2 impacts, Wien filter set at +/-0.8kV
Beam on CATS 1.2 10**5 pps
CH2 183 µm
Div as before |
Fixed | e744 |
Mon May 28 20:38:21 2018 |
E744- evening shift LISE+MUST2 teams (edit Valérie) | RUN | General | CH2 | RUN 2101 DATA target 4 |
run #2101
start @20h27
stop @22h20
target 4
Evening shift team:
LISE and E744 François, Iulan, Valérian, Louis, Jean-Charles, Marlete A., Pierre D., Simon G., Valérie L.
E744
Beam on CATS 1.2 10**5 pps
CH2 183 µm // ERROR ?? this should be 100um
Div as before
All Triggers in GMT (without LISE) |
Fixed | e744 |
Mon May 28 16:32:38 2018 |
E744- Valérie | DAQ | General | N/A | DAS configuration files-References |
|
Fixed | e744 |
Mon May 28 18:27:45 2018 |
E744- Valérie | DAQ | General | N/A | High Voltages and intensities on MUST2 |
Check regularly the HT on the MUST2.
NB: without beam the current on Telescope 4 is high, between 9 and 11 µA. see snapshot.
NB: The Ioset was increased at 20 µA on Friday 25th (cf Id entry=490) to avoid trips on this telescope due to strong intensity fluctuations due to the beam. |
Fixed | e738 |
Wed Jul 11 20:00:01 2018 |
Didier, Valérie, Louis | RUN | General | Cryo-LH2 | RUN 352 |
Run 352
Start 19h57 Stop 21h51
========================================
Beam: 9C
1.9*10**5pps in CATS1
1.7*10**5pps in CATS2
2.7*10**5pps in CAVIAR (10mbar 720V)
1.6uA of intensity of the primary beam
CATS1 670V 0.14 µA
CATS2 650V 0.10 µA
========================================
Oil troubles in the Ion source. Vacuum alarm stopped the beam. They call the astreinte
Can see gain decreasing of strip 9 in CATS1 Y |
Fixed | e738 |
Wed Jul 11 23:36:27 2018 |
Didier, Louis, Freddy, Shumpei | RUN | General | Cryo-LH2 | RUN 354 |
Run 354
Start 23h33 Stop 1h37
Run stopped due to water leak alarm somewhere under investigation (call from PCP)
========================================
Beam: 9C
Large fluctuation of the beam intensity from 190kpps to few kpps
1.9*10**5pps in CATS1
1.7*10**5pps in CATS2
2.8*10**5pps in CAVIAR (10mbar 720V)
1.8uA of intensity of the primary beam
CATS1 670V 0.12 µA
CATS2 650V 0.08 µA
========================================
HV and current stable |
Fixed | e738 |
Wed Jul 11 19:08:40 2018 |
Didier, Louis | RUN | General | Cryo-LH2 | RUN 350 |
Run 350
Start 19h00 Stop 19h11
========================================
Beam: 9C
2.1*10**5pps in CATS1
1.8*10**5pps in CATS2
1.5*10**5pps in CAVIAR
2uA of intensity of the primary beam
CATS1 670V 0.16 µA
CATS2 650V 0.10 µA => 2 over-current/min
======================================== |
Fixed | e738 |
Wed Jul 11 19:17:20 2018 |
Didier, Louis | RUN | General | Cryo-LH2 | RUN 351 |
Run 351
Start 19h14 Stop 19h53
========================================
Beam: 9C
2.1*10**5pps in CATS1
1.8*10**5pps in CATS2
3.1*10**5pps in CAVIAR (10mbar 720V)
1.9uA of intensity of the primary beam
CATS1 670V 0.16 µA
CATS2 650V 0.12 µA => 2 over-current/min
========================================
Good efficiency of CAVIAR at 720V and 10mbar |
Fixed | e738 |
Wed Jul 11 13:24:34 2018 |
Daisuke,CATS team: Séb, Thom ; Franck, Pierre, Valérie | RUN | General | Cryo-LH2 | Runs 344-345 |
Wed 11 July 2018
run 344 start 12h43 ; stop 13h03
e748 Exxx 900M 11 juil. 13:03 /data/e748X/e755/acquisition/run/run_0344.dat.11-07-18_12h43m33s
run 345 start 13h02 ; stop 14h49
e748 Exxx 3,2G 11 juil. 14:49 /data/e748X/e755/acquisition/run/run_0345.dat.11-07-18_13h02m22s
- - - - - - - - - - - - - - - - - -- - - - - - - - -- - - - - - - - -- - - - - - - - -
change of HV on CATS during Run 345: from 650V to 670V
Current on CATS2 is fluctuating (from 0.12 µA up to 0.6 µA) at oscilloscope, signals remain correct.
At 670V it is better for CATS2 efficiency
See plots : run345_EnergyChioRawTsdiff.png and run345_correlDeIChiotofCatsHF.png
Integral for IC is 8075; integral of the physical events in IC DE versus TOF CATS1 is 7548; for CATS2: integral 7044.
We have a rough estimate of CATS efficiencies: 7548/8075= 93%, for CATS2 87%.
The counting rates on CATS have closer values (at 650V, CATS2 is at 130 k pps; at 670V rate is 170k pps)
CATS1: 190k pps
CATS2: 170k pps
Plastic: 175k pps
|
Fixed | e755 |
Tue Jun 26 09:01:23 2018 |
Daisuke, Takeshi, Yorick, Valérie | RUN | General | Cryo-LH2 | RUN 140 |
Run 140 start: 8h55 ; stop: 9h59
748 Exxx 3348489513 26 juin 09:59 /data/e748X/e755/acquisition/run/run_0140.dat.26-06-18_08h55m32s
The Csi Mate were put on the trigger again "ENABLE" in the DAS. see snapshot DAS_MUVIenableMateCsI.png
Trigger: all MM + CATS DIV
Dead time between 16 to 35%
Beam= 3.0x10**5 pps at 9h06 Run140_scalersAt9h06.png fluctuating [cf scalers at 9h01 (0) Run140_scalersAt9h01.png]
Slits (summary):
FH31 +/- 4mm ; FH43 ++/-5mm ; FV43 +/-1 4.1 mm
Slits 61 and 62 opned. FV61 +/-17.9 mm; FH61 -22;+18.2 mm
FH62 +/-15mm ; FV62 +/-18 mm |
Fixed | e738 |
Sun Jul 8 21:50:58 2018 |
Daisuke, Takeshi, Valérie | RUN | General | Cryo-LH2 | RUN 297 |
Run 297 start 21h51 (8th July) stop at 0h (9th July)
e748 Exxx 3,0G 9 juil. 00:00 run_0297.dat.08-07-18_21h50m55s
MISSING STRIP, Y12 of CATS1 since run 296. see run297_CATSQRaw.png
CATS 1 640V I ~ 0.14 µA
CATS2 670V I ~ 0.14 µA
Beam 10C around 9. 10**4 and 10**5/s
Dead time between 7 and 13%
|
Fixed | e738 |
Sun Jul 8 17:59:12 2018 |
Daisuke, Takeshi, Valérie | RUN | General | Cryo-LH2 | RUN 295 |
Run 295 start 17h52 stop at 19h52
Beam stop occurred during 19h39 and 19h42 (alarm at the machine)
e748 Exxx 3,0G 8 juil. 19:53 run_0295.dat.08-07-18_17h52m05s
HV for CATS 1 put back at 640V. I ~ 0.12 to 0.14 µA
CATS2 670V I ~ 0.12 µA
Beam 10C around 10**5/s
Dead time between 6 and 13% |
Fixed | e738 |
Sun Jul 8 20:00:42 2018 |
Daisuke, Takeshi, Valérie | RUN | General | Cryo-LH2 | RUN 296 +(on-line) eff of CATS |
Run 296 start 19h52 stop at 21h51
e748 Exxx 3,1G 8 juil. 21:51 run_0296.dat.08-07-18_19h52m46s
MISSING STRIP, Y12 of CATS1, during the run, see plots Run296_CATS_Qraw.png and Run296_CATS_Qcal.png.
CATS 1 640V I ~ 0.16 µA
CATS2 670V I ~ 0.14 µA
Beam 10C around 10**5/s
Dead time between 7 and 13%
Tests [V.lx) to be checked>>>] Online checkings of CATS efficiencies.
note that the Plast cannot be used directly for the control of CATS efficiencies in the online plots: Run296_plotPlastTcats.png
Plastics is counting nearly 65% more than CATS (cf Scalers +snapshot below zoomed on physical peaks). The Plastics also include secondary reactions and betas.
The correlation plots between the ionization chamber and the T_CATS_HF can be used, with suppression of the plot underflows. See plot examples.
In ICNumexo0_energy_Raw the integral is 8552. [Run296_ICenergyRawZoom.png]
The plot integrals are 7718 and 7841 for CATS1 and 2. [Run296_plotCorrelICCats.png]
The corresponding efficiencies are 90% and 92% for CATS1 and CATS2 (7718/8552 ~ 0.90 and 7841/8552 ~ 0.92) |