Fixede738 Sun Jul 8 17:36:47 2018 Daisuke, Didier, ValérieRUNGeneralCryo-LH2RUN 294
Run 294 start 17h31 stop 17h50 due to the trip of CATS1.
748 Exxx 403M 8 juil. 17:50 run_0294.dat.08-07-18_17h31m47s

HV for CATS increased by 10V for Run 294
CATS1 HV = 650V I ~ 0.2 ľA ; CATS2 670V I ~ 0.14 ľA
Beam 10C around 10**5/s
Dead time between 6 and 13%
Fixede738 Sun Jul 8 17:59:12 2018 Daisuke, Takeshi, ValérieRUNGeneralCryo-LH2RUN 295
Run 295 start 17h52 stop at 19h52
Beam stop occurred during 19h39 and 19h42 (alarm at the machine)

e748 Exxx 3,0G 8 juil. 19:53 run_0295.dat.08-07-18_17h52m05s

HV for CATS 1 put back at 640V. I ~ 0.12 to 0.14 ľA
CATS2 670V I ~ 0.12 ľA
Beam 10C around 10**5/s
Dead time between 6 and 13%
Fixede738 Sun Jul 8 20:00:42 2018 Daisuke, Takeshi, ValérieRUNGeneralCryo-LH2RUN 296 +(on-line) eff of CATS
Run 296 start 19h52 stop at 21h51

e748 Exxx 3,1G 8 juil. 21:51 run_0296.dat.08-07-18_19h52m46s

MISSING STRIP, Y12 of CATS1, during the run, see plots Run296_CATS_Qraw.png and Run296_CATS_Qcal.png.
CATS 1 640V I ~ 0.16 ľA
CATS2 670V I ~ 0.14 ľA
Beam 10C around 10**5/s
Dead time between 7 and 13%

Tests [V.lx) to be checked>>>] Online checkings of CATS efficiencies.
note that the Plast cannot be used directly for the control of CATS efficiencies in the online plots: Run296_plotPlastTcats.png
Plastics is counting nearly 65% more than CATS (cf Scalers +snapshot below zoomed on physical peaks). The Plastics also include secondary reactions and betas.

The correlation plots between the ionization chamber and the T_CATS_HF can be used, with suppression of the plot underflows. See plot examples.
In ICNumexo0_energy_Raw the integral is 8552. [Run296_ICenergyRawZoom.png]
The plot integrals are 7718 and 7841 for CATS1 and 2. [Run296_plotCorrelICCats.png]
The corresponding efficiencies are 90% and 92% for CATS1 and CATS2 (7718/8552 ~ 0.90 and 7841/8552 ~ 0.92)
Pinnede738 Sun Jul 8 21:05:50 2018 daisukeOTHERGeneralN/APhase space simulation: 10C(p,t)8C and 9C(p,d)8C
Fixede738 Sun Jul 8 21:50:58 2018 Daisuke, Takeshi, ValérieRUNGeneralCryo-LH2RUN 297
Run 297 start 21h51 (8th July) stop at 0h (9th July)
e748 Exxx 3,0G 9 juil. 00:00 run_0297.dat.08-07-18_21h50m55s
MISSING STRIP, Y12 of CATS1 since run 296. see run297_CATSQRaw.png
CATS 1 640V I ~ 0.14 ľA
CATS2 670V I ~ 0.14 ľA
Beam 10C around 9. 10**4 and 10**5/s
Dead time between 7 and 13%
Fixede738 Mon Jul 9 00:03:24 2018 Benoit, Megumi, Takeshi, ValérieRUNGeneralCryo-LH2RUN 298
Run 298 start 0h (9th July) stop at 02h02
e748 Exxx 2,9G 9 juil. 02:02 run_0298.dat.08-07-18_23h59m40s
Beam stop occurred from 01h06 to 01h09 (rotation speed failing of the LISE target)

MISSING STRIP, Y12 of CATS1 since run 296.
CATS 1 640V I ~ 0.14 ľA
CATS2 670V I ~ 0.14 ľA
Beam 10C around 8. 10**4 and 10**5/s
Dead time between 7 and 13%
Fixede738 Mon Jul 9 00:25:30 2018 NoriCATSGeneralN/ACATS tracking efficiency
We noticed that the tracking efficiency was only 70% while the timing efficiencies were around 95%.
By lowering the thresholds (see Attachment 5-8) 89% tracking efficiency was achieved.
Note: analyzed run 293 (CATS1 640V, CATS2 670V), first 10000 events, only CATS trigger was selected.
Fixede738 Mon Jul 9 02:16:19 2018 Benoit, MegumiRUNGeneralCryo-LH2RUN 299
Run 299 start 02h01 (9th July) stop at 04h03
e748 Exxx 2,9G 9 juil. 04:03 run_0299.dat.09-07-18_02h01m29s

MISSING STRIP, Y12 of CATS1 since run 296.
CATS 1 640V I ~ 0.12 ľA
CATS2 670V I ~ 0.12 ľA
Beam 10C around 8. 10**4 and 10**5/s
Dead time between 7 and 13%
Fixede738 Mon Jul 9 04:22:21 2018 Benoit, MegumiRUNGeneralCryo-LH2RUN 300
Run 300 start 04h02 (9th July) stop at 06h04
e748 Exxx 2,8G 9 juil. 06:05 run_0300.dat.09-07-18_04h02m08s

MISSING STRIP, Y12 of CATS1 since run 296.
CATS 1 640V I ~ 0.12 ľA
CATS2 670V I ~ 0.12 ľA
Beam 10C around 8. 10**4 and 10**5/s
Dead time between 7 and 13%
Fixede738 Mon Jul 9 06:21:54 2018 Benoit, MegumiRUNGeneralCryo-LH2RUN 301
Run 301 start 06h04 (9th July) stop at 7h51


MISSING STRIP, Y12 of CATS1 since run 296.
CATS 1 640V I ~ 0.12 ľA
CATS2 670V I ~ 0.12 ľA
Beam 10C around 8. 10**4 and 10**5/s
Dead time between 7 and 13%
Fixede738 Mon Jul 9 07:55:05 2018 PierreRUNGeneralCryo-LH2Run 302
start: 07h53
stop: 08h19

We stop the run to warm up the target
Fixede738 Mon Jul 9 08:00:11 2018 takeshiTARGETHardwareCryo-LH2temperature log of the target
Here are the temperature log of the cyo H2 target during the 10C setting.
Fixede738 Mon Jul 9 08:55:13 2018 Pierre DaisukeRUNGeneralEmptyRun 303
start: 08h27
stop: 08h50

Run for background with no beam
Fixede738 Mon Jul 9 08:56:50 2018 Pierre DaisukeRUNGeneralCryo-emptyRun 304
start: 08h54
stop: 10h00

Run with same trigger but empty target
TRIGGER: MMi, CATS1DIV, CATS2DIV, PLASTIC%
Fixede738 Mon Jul 9 15:43:50 2018 Pierre ValérieRUNGeneralCryo-emptyRun 309
start: 15h36
stop: 16h10

Trigger: OR MM, CATS1 DIV and PLASTIC%

large beam interuption between 15h40 and 16h06
Fixede738 Mon Jul 9 17:18:55 2018 e748RUNGeneralCryo-emptyRUN 311
Run 311
Beam/Detectors Tuning

start: 17h04 stop: 17h16
Beam: 9C
target: empty

Trigger: T1 to T8, CATS1%, PLASTIC%

I=1.5*10⁵pps in CATS1
Purity = 6.3%


HV of plastic has been changed to 2100V
Fixede738 Mon Jul 9 18:03:48 2018 Valérie LouisRUNGeneralCryo-LH2RUN 312
Run 312

First RUN of 9C on filled LH2 target

start: 17h36 stop: 18h56
Beam: 9C
target: filled

Trigger: T1 to T8, CATS1%3*10⁴, CATS2%3*10⁴, PLASTIC%1*10⁴

I=1.4*10pps in CATS1
Purity = 5.1%


HV of DC wire has been changed from 500V to 530V
Plastic threshold has been changed from 180mV to 70mV

Target has been succefully filled
Fixede738 Mon Jul 9 19:16:13 2018 Freddy LouisRUNGeneralCryo-LH2RUN 313 to 316
From RUN 313 to RUN 316:

Tuning dor the Drift Chamber:
  • threshold changed
  • CFD discriminator has been tuned in GECO
  • Buffer size has been change to match with the new setting

DC now works as well as th online visualisation
Acquisition is stable
Fixede738 Mon Jul 9 19:24:06 2018 Freddy Valérie LouisRUNGeneralCryo-LH2RUN 317
Run 317

start: 19h08 stop: 19h30
Beam: 9C
target: filled

Trigger: T1 to T8, CATS1%3*104, CATS2%3*10⁴;, PLASTIC%1*10⁴

I=1.8*10pps in CATS1
Purity = 5.1%
Fixede738 Mon Jul 9 20:28:09 2018 Daisuke, Freddy, Louis, ValérieRUNGeneralCryo-LH2RUNS 318 to 320
From RUN 318 to RUN 320:
initial problem was that the stop process was not correctly taken into account on Narval. Geco acor was still running.
We killed Narval.
It was impossible to initialize or start run correctly.We did Several kna, kall.
Bugs on the run control server (ps -edf |grep narval or start_acq showed several on-going processes. We removed them). Then the CATS1 crate was not initialized correctly, it remained Offline.
see ProblemDAQcrateCATS1RCAt20h.png ProblemDAQcrateCATS1iolan.png
We rebooted (software mode on Iolan) CATS1 VXI crate, then init..;breakup...init then tried to start but stopped because because we noted merger problems.
See ProblemMergerCATSbranch.png
Then we needed to reinitialize a third time the Narval run control bto recover a correct Run control operation.

Fred S. came to check that we worked well... and that everything was working well.