Fixed, e755, Sat Jun 30 20:08:27 2018, didier, takeshi, daisuke, RUN, General, Cryo-LH2, RUN 199 37C + liq. H 28x
 
Ongoing, e755, Sat Jun 30 20:12:33 2018, takeshi, TARGET, Hardware, Cryo-LH2, target temperature cell3006.pngheatshield3006.pngscreenshot_2018-07-01_12.17.48.pngscreenshot_2018-07-01_12.22.29.png
Latest update at 12:15 pm on July 1
Here are the temperature logs up to 7:00pm 30/6.
Fixed, e755, Sat Jun 30 23:47:45 2018, takeshi, daisuke, didier, BEAM, General, Cryo-LH2, result of Wien filter tuning wienfiltertuning3006.pngposition37Carun200.pdfposition37Carun201.pdfposition37Carun202.pdf
Here is the summary of the tuning of the Wien filter.
We tried to tune the correction magnet of the wien filter to change the Y position of the beam, especially for 37Ca, which seemed to be at slightly higher
position. 
Fixed, e755, Sun Jul 1 01:48:23 2018, Adrien, RUN, General, Cryo-LH2, Run 205 run205.psr205_HT.pngr205_HT0.pngr205_scaler.png
Starting Run 205 at 1:45.
CATS 1 : 22kps
CATS 2 : 23kps
Fixed, e755, Sun Jul 1 06:42:28 2018, e748, OFFLINE, General, Cryo-LH2, offline of run 192-206 37Capd_192-207.pdf
Here are te plot of analysis of all the available statistic on 37Ca pd.
Fixed, e755, Sun Jul 1 09:43:58 2018, Benoit, Franck, RUN, General, Cryo-LH2, Run 209 9x
Sun 1 July 2018

Start 9:26
Fixed, e755, Sun Jul 1 09:48:44 2018, Benoit, Franck, RUN, General, Cryo-LH2, Run 208 (ENTRY POSTPONED) 7x
Sun 1 July

Start 7:17
Fixed, e755, Sun Jul 1 11:52:27 2018, Benoit, Franck, RUN, General, Cryo-LH2, Run 210 7x
Sun 1 July 2018

Start 11:46
Fixed, e755, Sun Jul 1 17:11:55 2018, freddy, shumpei, daisuke, RUN, General, Cryo-LH2, RUN 214 scaler_2018-07-01_17h10m39s.pngvisu_2018-07-01_17h10m37s.pngvisu_2018-07-01_17h13m30s.png
from 17h01 to 18h39 (anoxia alert. PCP to inspect). 40ca ~3.0 micro A. 
Fixed, e755, Sun Jul 1 18:44:24 2018, freddy, shumpei, daisuke, RUN, General, N/A, RUN 215 scaler_2018-07-01_19h19m32s.pngvisu_2018-07-01_19h19m32s.pngvisu_2018-07-01_19h19m40s.png
Alpha source run. no beam
18h41 started 
19h22 ended
Fixed, e755, Sun Jul 1 19:22:32 2018, freddy, shumpei, daisuke, RUN, General, Cryo-LH2, RUN 216 scaler_2018-07-01_20h05m43s.pngvisu_2018-07-01_20h05m44s.pngvisu_2018-07-01_20h05m52s.pngscaler_2018-07-01_21h18m41s.pngvisu_2018-07-01_21h15m41s.png
37Ca + liquid H 
19h20 started 
21h18 ended.
Fixed, e755, Sun Jul 1 21:21:18 2018, Louis, RUN, General, Cryo-LH2, RUN 217 scaler_2018-07-01_21h22m54s.pngvisu_2018-07-01_21h24m16s.pngvisu_2018-07-01_21h24m33s.pngvisu_2018-07-01_21h24m48s.png
RUN 217

37Ca beam at 2.104pps
Fixed, e755, Sun Jul 1 23:18:21 2018, freddy, louis, shumpei, daisuke, RUN, General, Cryo-LH2, RUN 219 7x
37ca + liq.H
22h50 started
1h00 ended
Fixed, e755, Mon Jul 2 00:53:49 2018, Louis, OFFLINE, General, Cryo-LH2, Update offline analysis on 37Ca(p,d)36Ca 37Capd_All_192_0277.pdf37Capd_Z19_FIT_192_0277.pdf37Capd_Z20_192_0277.pdf
Update of offline Analysis of the [B]37Ca(p,d)36Ca[/B] reaction:

Run 192 to 207
Fixed, e755, Mon Jul 2 01:01:15 2018, daisuke, TARGET, General, Cryo-LH2, cryogenic target logger screenshot_2018-07-02_01.00.23.pngscreenshot_2018-07-02_02.57.45.pngscreenshot_2018-07-02_02.58.23.png
 
Fixed, e755, Mon Jul 2 01:05:12 2018, louis, daisuke, RUN, General, Cryo-LH2, RUN 220 scaler_2018-07-02_01h04m12s.pngvisu_2018-07-02_01h13m50s.pngvisu_2018-07-02_01h14m29s.pngscaler_2018-07-02_01h56m52s.png
37ca + liq.H. 
1h01 started
1h56 ended.Beam stopped due to the trouble with HF C0.
Ongoing, e738, Mon Jul 2 01:29:58 2018, daisuke, OTHER, General, N/A, Q values ensdf_10c_via_pt.pdfPhysRevC.3.543.pdf
 
 Reaction : 9C(1H,3H)7C  Q -29.5098 MeV  Ex 0 MeV
    9C  Z   6 A   9  Mass excess    28911.0 keV 
Fixed, e755, Mon Jul 2 01:58:07 2018, louis daisuke, RUN, General, Cryo-LH2, RUN 221 6x
37ca + liquid H (no beam at times)
1h56 started. no beam
2h03 beam came back with low intensity. Keep running.
Fixed, e755, Mon Jul 2 04:02:15 2018, louis daisuke, RUN, General, Cryo-LH2, RUN 222 8x
37Ca + liq. H
4h00 started
5h57 ended.
Fixed, e755, Mon Jul 2 06:01:35 2018, louis daisuke, RUN, General, Cryo-LH2, RUN 223 7x
37Ca + liquid H. 
5h59 started.40Ca  3.3 micro A.
6h17 beam stop. A few issues including RF. 