MUST2 SAMURAI_2018 S3-LEB-LPC SUPERNEMO MUGAST EXPAND SCALP GALATRON HiCARI VELO
  MUST2, Page 36 of 48  Not logged in MUST2
Status ExpNbr Date Authordown Type Category Target-Source Subject
Ongoinge738 Wed Jul 11 17:25:11 2018 Louis, Daisuke, Nori, ValérieRUNGeneralCryo-LH2Run 348
Run 348 Start 17h17

Beam: 9C at 2.3*10⁵pps in CATS1, 2uA of intensity of the primary beam


CATS1 670V 0.16 ľA ,
CATS2 650V 0.12 -> 0.6 ľA

Rates:
CATS1: 230 kpps
CATS2: 200 kcps
CAVIAR: 260 kcps
Plastic: 200 kcps
Attachment 1: run348_scalersAt17h26.png
run348_scalersAt17h26.png
Attachment 2: visu_2018-07-11_17h39m20s.png
visu_2018-07-11_17h39m20s.png
Attachment 3: visu_2018-07-11_17h39m25s.png
visu_2018-07-11_17h39m25s.png
Attachment 4: scaler_STOP_2018-07-11_18h09m53s.png
scaler_STOP_2018-07-11_18h09m53s.png
Fixede755 Mon Jul 2 23:29:32 2018 Louis PierreOTHERHardwareN/ANew division for CATS and plastic
Division for CATS and Plastic: 3x10^4

Plastic => Chanel 16 of GMT
Fixede755 Thu Jun 7 09:46:47 2018 LouisMUST2Hardware3-alphaMUST2 test
The 8 MUST2 telescopes have been installed and pluged in final configuration. Energy signal have been tested with 2 3-alphas sources, one in front of T5-T6 and one in front of the others.
Energy signal for all telescopes looks ok exept for telescopes 5. Concidering their position with respect to the source T5 and T6 should have the same count. In fact, T5X see signal at the good energy but with two times less count than T6X. T5Y see 10 times less count than T6Y.
One can also see some noise on the middle part of T8X
Attachment 1: MMYE1_4_3alpha_06062022.png
MMYE1_4_3alpha_06062022.png
Attachment 2: MMYE1_4_3alpha_06062021.png
MMYE1_4_3alpha_06062021.png
Attachment 3: MMYE1_4_3alpha_06062020.png
MMYE1_4_3alpha_06062020.png
Attachment 4: MMYE1_4_3alpha_06062019.png
MMYE1_4_3alpha_06062019.png
Fixede755 Thu Jun 7 12:19:18 2018 LouisMUST2HardwareN/AMUST2 configuration, X1Y1 and PCB numbers
Pictures showing the MUST2 configuration.
X and Y positions and PCB numbers are as folow are as follow:
T1, PCB5: 

Y128.......X128Y1
    .     . 
    .     .
    .......X1 



T2, PCB4:  

    .......Y128 
    .     .
    .     .
X1.......X128Y1 



T3, PCB7: 

X1....... 
    .     .
    .     .
X128Y1.......Y128 




T4, PCB10: 

X128Y1.......X1 
    .     .
    .     .
Y128....... 




T5, PCB6: 

X128Y1.......X1 
    .     .
    .     .
Y128....... 



T6, PCB2:  

    .......Y128 
    .     .
    .     .
X1.......X128Y1 



T7, PCB8: 

X128Y1.......X1 
    .     .
    .     .
Y128....... 



T8, PCB3: 

Y128.......X128Y1
    .     . 
    .     .
    .......X1
Attachment 1: Config_MUST2.jpg
Config_MUST2.jpg
Attachment 2: Config_MUST2_T56.jpg
Config_MUST2_T56.jpg
Fixede755 Thu Jun 7 13:54:59 2018 LouisMUST2HardwareN/AMUST2 Time
MUST2 time have been tested for T1 to T8 for X and Y. FAG has been delayed with 150ns and 500ns and sent as stop in MUVI 1 and 2. One can see two pics in all spectrum. All scales of TAC have been setted to 600ns.
Attachment 1: MMXT1_4_07062018.png
MMXT1_4_07062018.png
Attachment 2: MMYT1_4_07062018.png
MMYT1_4_07062018.png
Attachment 3: MMYT5_8_07062018.png
MMYT5_8_07062018.png
Attachment 4: MMXT5_8_07062018.png
MMXT5_8_07062018.png
Fixede755 Thu Jun 7 17:12:38 2018 LouisMUST2Hardware3-alphaCalib Alpha
Run 3028: Calib 3 alpha started at 17h05
Run3029:Calib 3 alpha started at 17h54

Config pedestals aligned. Saved in files:
E755_Tx_07062018

Temperature on ASIC:
T1X: 7 deg
T1Y: 4
T2X: 7
T2Y: 4
T3X: 6
T3Y: 3
T4X: 5
T4Y: 3
T5X: 8
T5Y: 6
T6X: 12
T6Y: 5
T7X: 5
T7Y: 1
T8X: 10
T8Y: 8


Telescopes 1 to 8 are ok for X and Y Energy and Time signal
Attachment 1: MMYE1_4_08062020.png
MMYE1_4_08062020.png
Attachment 2: MMYE5_8_08062020.png
MMYE5_8_08062020.png
Attachment 3: MMXE1_4_08062019.png
MMXE1_4_08062019.png
Attachment 4: MMXE5_8_08062019.png
MMXE5_8_08062019.png
Fixede755 Sun Jun 10 19:51:52 2018 LouisMUST2Hardware3-alphaCalibration run
Run3031:Calib 3 alpha started at 19h49
stoped at 9h15

Temperature on ASIC:
T1X: 7 deg
T1Y: 4
T2X: 7
T2Y: 4
T3X: 6
T3Y: 3
T4X: 5
T4Y: 3
T5X: 8
T5Y: 5
T6X: 12
T6Y: 4
T7X: 5
T7Y: 1
T8X: 10
T8Y: 8


energy resolution in X telescope 5 seems a little bit worst than for the other telescopes but cannot see some double pics effect
Attachment 1: MMYE1_4_11062020.png
MMYE1_4_11062020.png
Attachment 2: MMYE5_8_11062020.png
MMYE5_8_11062020.png
Attachment 3: MMXE1_4_11062020.png
MMXE1_4_11062020.png
Attachment 4: MMXE5_8_projection_11062020.png
MMXE5_8_projection_11062020.png
Fixede755 Mon Jun 11 12:50:56 2018 LouisMUST2Hardware3-alphaImpact matrix
Impact matrix for Telescope 1 to 8 from the run 3029 calibrated
Attachment 1: ImpactMatrix_T1_11062018.png
ImpactMatrix_T1_11062018.png
Attachment 2: ImpactMatrix_T2_11062018.png
ImpactMatrix_T2_11062018.png
Attachment 3: ImpactMatrix_T3_11062018.png
ImpactMatrix_T3_11062018.png
Attachment 4: ImpactMatrix_T4_11062018.png
ImpactMatrix_T4_11062018.png
Attachment 5: ImpactMatrix_T5_11062018.png
ImpactMatrix_T5_11062018.png
Attachment 6: ImpactMatrix_T6_11062018.png
ImpactMatrix_T6_11062018.png
Attachment 7: ImpactMatrix_T7_11062018.png
ImpactMatrix_T7_11062018.png
Attachment 8: ImpactMatrix_T8_11062018.png
ImpactMatrix_T8_11062018.png
Fixede755 Mon Jun 11 13:28:21 2018 LouisONLINEHardware3-alphaEnergy resolution MUST2
Energy resolution of the 8 MUST2 telescopes from central pic of run 3029 calibrated with 3 alpha source.

T1: mean = 5.389MeV , sigma = 15.0keV
T2: mean = 5.385MeV , sigma = 15.7keV
T3: mean = 5.391MeV , sigma = 15.2keV
T4: mean = 5.418MeV , sigma = 14.0keV
T5: mean = 5.390MeV , sigma = 16.3keV
T6: mean = 5.391MeV , sigma = 14.6keV
T7: mean = 5.389MeV , sigma = 17.5keV
T8: mean = 5.386MeV , sigma = 14.7keV
Total: mean = 5.391MeV , sigma = 17.7keV
Fixede755 Sat Jun 23 01:55:34 2018 LouisBEAMGeneralCH2Beam tunning
Beam was tunned around 1am to center the beam on the target. On the picture, up is after tunning and down is before tunning
Attachment 1: beam_tunnig23_06_1h_24m.png
beam_tunnig23_06_1h_24m.png
Fixede755 Sat Jun 23 04:16:03 2018 LouisOFFLINEGeneralCH2deltaE E
here a plot of energy loss in DSSD in function of energy in CsI. One can distinguish proton and alpha. Energy calibration of the CsI is needed to identify clearly the tritons
Attachment 1: dEE_noCalib_run0063.jpg
dEE_noCalib_run0063.jpg
 e755 Sat Jun 23 06:16:25 2018 LouisOFFLINE   
Fixede755 Tue Jun 26 13:37:44 2018 LouisRUNGeneralCryo-LH2RUN 145
Run 145 -- 26th June start@ 13h07 ; stop @ 13h53
e748 Exxx 2239017281 26 juin 13:53 /data/e748X/e755/acquisition/run/run_0145.dat.26-06-18_13h06m30s
Trigger: all MM + CATS DIV
conditions of the MUST2 pedestals as before
Attachment 1: run_145_CATScal.png
run_145_CATScal.png
Attachment 2: run_145_CATSpos.png
run_145_CATSpos.png
Attachment 3: run_145_scalers.png
run_145_scalers.png
Fixede755 Thu Jun 28 08:29:08 2018 LouisCATSGeneralCryo-LH2CATS-HF time shift during the night
noticed that the time between CATS and HF shifted during the night.
run 164 to 169
Attachment 1: CATS1_HF_0165.pdf
CATS1_HF_0165.pdf
Attachment 2: CATS1_HF_0167.pdf
CATS1_HF_0167.pdf
Attachment 3: CATS1_HF_0168.pdf
CATS1_HF_0168.pdf
Attachment 4: CATS1_HF_0169.pdf
CATS1_HF_0169.pdf
Attachment 5: CATS2_HF_0164.pdf
CATS2_HF_0164.pdf
Attachment 6: CATS2_HF_0166.pdf
CATS2_HF_0166.pdf
Fixede755 Fri Jun 29 00:59:15 2018 LouisOFFLINEGeneralCryo-LH2Analysis of run 63 to 89 in 40Ca(p,t)38ca reaction
Here are some plot summarizing the analysis status on the 40Ca(p,t)38Ca channel.

Run concerned: 63-89
Running time: 18 hours

Gates applied:
  • Target Impact (from CATS)
  • Triton in dE-E
  • Incoming 40Ca, TCATS2_HF in [1600;24000]

Plots:
  • Cut applied
  • Kinematics, Exitation energy and llaboratory angle for two possible pics
  • Exitation energy per telescope for T1 to T4


Remarks:
  • There is no clear signal of ground state or any exited states
  • One can mybe distinguish pics correspond to different states but badly separated
  • During this beam time, Ionization Chamber was not working. Analysis of the 38Ca(p,t)36Ca reaction without this cut provide exactly the same shape of background. This background is probably due to fragmentation of the 40Ca beam in HAVAR foil, producing tritons undistinguishable from reaction tritond without cut on outgoing heavy ion.

    Other runs in 40Ca with the CHIO are probably needed to make good Ex reconstruction and tritons calibrations
Attachment 1: Chek_cuts_40Capt.png
Chek_cuts_40Capt.png
Attachment 2: Kinematics_40Ca.png
Kinematics_40Ca.png
Attachment 3: Telescope_Ex_40Capt.png
Telescope_Ex_40Capt.png
Attachment 4: Kinematics_38Capt_withoutCutZero.png
Kinematics_38Capt_withoutCutZero.png
Fixede755 Fri Jun 29 12:39:34 2018 LouisOFFLINEGeneralCryo-LH2Analysis 38Ar(p,t)36Ar run 128 to 156
Here are some plot summarizing the analysis status on the 36Ar(p,t)34Ar channel.

Run concerned: 128-156
Running time: 31 hours

Gates applied:
  • Target Impact (from CATS)
  • Triton in dE-E
  • Incoming 36Ar, TCATS2_HF in [1600;24000]
  • Outgoin Z=18, delta_E E

Plots:
  • Kinematics, Exitation energy
  • Exitation energy per telescope for T1 to T4, with fit for two pics


Remarks:
  • We are able to distinguish two different states coressponding two known 0+ and 2+ states
  • By looking excitation energy telescope by telescope, we can see a shift between T1,2 and T3,4. Again, left right misalignement of MUST2 is highlight

    Runs in 26Ar will be helpfull for E tritons calibrations in CsI
Attachment 1: Kinematics_36Arpt_FIT1Ex.png
Kinematics_36Arpt_FIT1Ex.png
Attachment 2: Kinematics_36Arpt_FITGS.png
Kinematics_36Arpt_FITGS.png
Attachment 3: Telescope_Ex_36Arpt.png
Telescope_Ex_36Arpt.png
Attachment 4: Telescope_Ex_36Arpt_fit_exited.png
Telescope_Ex_36Arpt_fit_exited.png
Attachment 5: 36Ar_level_list.png
36Ar_level_list.png
Fixede755 Sat Jun 30 09:17:25 2018 LouisOFFLINEGeneralCryo-LH2Offline analysis of 37Ca(p,d)36Ca reaction
Here are some plot summarizing the analysis status on the 37Ca(p,d)36Ca channel. Plots shows performance of the setup in optimal conditions and preli;inary results.

Run concerned: 192-194
Running time: 6 hours

Gates applied:
  • Target Impact (from CATS)
  • deuton in dE-E
  • Incoming 37Ca, TCATS1_HF in [2800;3800]
  • Outgoing Z=20 and Z=19

Plots:
  • Ion identification in dE-TOF and dE-E
  • Light particle identification in dE-E
  • Kinematics, Exitation energy and laboratory angle for Gate on Z=20 and Z=19 outgoing nuclei
  • Previous results for 38Ca(p,t)36Ca analysis


Remarks:
  • Particle identification seems OK for light and heavy particles. We are able to reproduce wath we get during 38Ca beam. All component are well separeted
  • On the Z=20 gated spectra, one can distinguish two state. Excited state looks like to be at the same position (around 3MeV) than the one found in 38Ca(p,t)36Ca reaction.
  • On the Z=19 gated spectra, one can see state. Looks like to be at the same position (around 6MeV) than the one found in 38Ca(p,t)36Ca reaction with the same gate.

Results looks consistent with previous observations. Let's see wath will grown with more data!
Attachment 1: dE_E.png
dE_E.png
Attachment 2: dE_TOF.png
dE_TOF.png
Attachment 3: PID.png
PID.png
Attachment 4: Ex20vs19_pd_192to194_Z21.png
Ex20vs19_pd_192to194_Z21.png
Attachment 5: Kinematics_pd_192to194_Z19.png
Kinematics_pd_192to194_Z19.png
Attachment 6: Kinematics_pd_192to194_Z20.png
Kinematics_pd_192to194_Z20.png
Attachment 7: 38Capt_zero.pdf
38Capt_zero.pdf
Fixede755 Sun Jul 1 21:21:18 2018 LouisRUNGeneralCryo-LH2RUN 217
RUN 217

37Ca beam at 2.104pps
LH2
started at 21h18
Attachment 1: scaler_2018-07-01_21h22m54s.png
scaler_2018-07-01_21h22m54s.png
Attachment 2: visu_2018-07-01_21h24m16s.png
visu_2018-07-01_21h24m16s.png
Attachment 3: visu_2018-07-01_21h24m33s.png
visu_2018-07-01_21h24m33s.png
Attachment 4: visu_2018-07-01_21h24m48s.png
visu_2018-07-01_21h24m48s.png
Fixede755 Mon Jul 2 00:53:49 2018 LouisOFFLINEGeneralCryo-LH2Update offline analysis on 37Ca(p,d)36Ca
Update of offline Analysis of the 37Ca(p,d)36Ca reaction:

Run 192 to 207
Total time: 43h

same analysis for gate Z=20, Z=19 and Z=18 have been made.

In the first exited state at 5.5MeV of Z20 spectra we got 1557 counts ==> 36/h

in pic of Z19 spectra we got : 121 counts at 5.5MeV ==> 2.8/h
458 counts at 9.8MeV ==> 10.5/h

for the first excited state at 5.5MeV we got gamma to proton ratio of 7.7%

One can maybe distinguish resonnace in the Z18 spectra
Attachment 1: 37Capd_All_192_0277.pdf
37Capd_All_192_0277.pdf
Attachment 2: 37Capd_Z19_FIT_192_0277.pdf
37Capd_Z19_FIT_192_0277.pdf
Attachment 3: 37Capd_Z20_192_0277.pdf
37Capd_Z20_192_0277.pdf
Fixede755 Mon Jul 2 07:23:34 2018 LouisOFFLINEGeneralCryo-LH236Ca and 37Ca(p,t)35Ca reaction
RUN 192 to 222
Beam time: 62h

Here are shown plots for 37Ca(p,t)35Ca reaction.
Kinematics are shown by gating on Z=20. One can see a pic corresponding to the ground state of 35Ca with 20 counts. Corresponding count rate is about 0.32count/h
Reconstructed Exitation energie for Z20, Z19 and Z18 are also shown

Update of the 37Ca(p,d)36Ca reaction is also presented
Attachment 1: Ex_all_pd_192to222.png
Ex_all_pd_192to222.png
Attachment 2: Kinematics_pt_192to222_Z20.png
Kinematics_pt_192to222_Z20.png
Attachment 3: pt36Ca_Ex_all_192_222.png
pt36Ca_Ex_all_192_222.png
Attachment 4: Kinematics_pt_192to222_Z20_without_line.png
Kinematics_pt_192to222_Z20_without_line.png

ELOG Home Page