Status |
ExpNbr |
Date |
Author |
Type |
Category |
Target-Source |
Subject |
Text |
 |
Fixed | e744 |
Tue Apr 24 16:22:08 2018 |
e744 Valérie L. | RUN | Software | | Narval Merger Parameters | |
|
Fixed | e744 |
Wed Apr 25 20:47:59 2018 |
e744 Valérie | MUST2 | General | | MUST2 mate Temperature on the DAS interface | tests
The plot:ConfigDASMuvi1Tel4mufeeX.png shows
the situation on the Mufee card when the |
 |
Fixed | e744 |
Mon Apr 23 11:33:53 2018 |
e744 Valerian | OTHER | Hardware | N/A | Inspection signals | Inspection signals between D6 and LISE Acquisition
room are connected as follow :
|
|
Fixed | e744 |
Thu May 24 22:38:44 2018 |
e744 Must2+lise teams | RUN | General | CH2 | Run Beam Spiral 14N centered | Shift teams: François, Iulan, Freddy, Fairouz,
Valérian, Valérie, Mihail
LISE teams during evening: Omar Kamalou, |
7x |
Fixed | e744 |
Thu May 24 22:45:36 2018 |
e744 Must2+lise teams | RUN | General | CH2 | Run 1001 Beam Spiral 14N centered | Run 1001, cible n°6: 183 um
start @ 21h55; Stop @ 22h36
Shift teams: François, Iulan, Freddy, Fairouz, |
 |
Fixed | e744 |
Fri May 25 22:46:26 2018 |
e744 Must2+LISE teams, edit Valérie | RUN | General | CH2 | RUN 2004 |
Run 2004 Date : 25/05/2018 22:45:58 25/05/2018
23:17:39
|
6x |
Fixed | e744 |
Fri May 25 23:26:23 2018 |
e744 Must2+LISE teams, edit Valérie | RUN | General | CH2 | START NARVAL, new version | the NARVAL version is now reinstalled by Fred
Saillant.
see plot ResolProblemNarvalEndofRun25may23h.png
|
|
Fixed | e744 |
Fri May 25 22:03:12 2018 |
e744 Must2+LISE teams | RUN | General | CH2 | RUNS 2000, 2001 | Beam 14O
Run 2000 start with all triggers, including
LISE trigger, during 1 minute for tests.
|
6x |
Fixed | e744 |
Thu May 24 19:20:40 2018 |
e744 Must2 + Lise teams (edit: Valérie) | RUN | General | N/A | Run 460-Spiral 14N test | Run 460
Triggers Must2 Telescopes T1 to T5
( MM1 to MM5)
|
  |
Fixed | e744 |
Thu May 24 19:32:31 2018 |
e744 Must2 + Lise teams (edit: Valérie) | RUN | General | N/A | Run 461-Spiral 14N test | Run 461
Triggers Must2 Telescopes T1 to T5
(MM1 to MM5)
|
 |
Fixed | e744 |
Thu May 24 20:31:30 2018 |
e744 Must2 + Lise teams (edit: Valérie) | RUN | General | N/A | Run 463 Beam Spiral 14N test | Run 463 focalisation on Must2 24May at 20h30pm
storage
Triggers Must2 Telescopes T1 to T5
|
  |
Fixed | e744 |
Thu May 24 21:05:19 2018 |
e744 Must2 + Lise teams (edit: Valérie) | MUST2 | Hardware | N/A | change of STOP MUST2 | The STOP of MUST2 with CATS is now directly
the CATS "delayed signal".
No coincidence with FAG.
|
|
Fixed | e744 |
Thu May 24 21:28:45 2018 |
e744 Must2 + Lise teams (edit: Valérie) | RUN | General | CH2 | Run 464 Beam Spiral 14N test | Run 464 focalisation on Must2 24May at 21h25m
storage
Triggers Must2 Telescopes T1 to T5
|
    |
Fixed | e744 |
Thu May 24 19:34:40 2018 |
e744 Must2 + Lise teams | RUN | General | N/A | tuning Wien-Spiral 14N test | Run 24May at 19h50-20pm no storage
Triggers Must2 Telescopes T1 to T5
(MM1 to MM5)
|
|
Fixed | e744 |
Thu May 24 20:18:00 2018 |
e744 Must2 + Lise teams | RUN | General | N/A | tuning Wien-Spiral 14N test | Run 24May at 19h50-20pm no storage
Triggers Must2 Telescopes T1 to T5
(MM1 to MM5)
|
   |
Fixed | e744 |
Thu May 24 20:19:19 2018 |
e744 Must2 + Lise teams | RUN | General | N/A | Beam centering on MM5-Spiral 14N test | Run 24May at 19h50-20pm no storage
Triggers Must2 Telescopes T1 to T5
(MM1 to MM5)
|
  |
Fixed | e744 |
Thu May 24 20:21:57 2018 |
e744 Must2 + Lise teams | RUN | General | N/A | Run 462 Beam centering on MM5-Spiral 14N test | Run 462 focalisation on target 24May at 20h15pm
storage
Triggers Must2 Telescopes T1 to T5
|
   |
Pinned | e744 |
Thu May 24 23:20:40 2018 |
e744 Must2 + Lise teams | RUN | General | CH2 | run 1002 | [I][B]run 1002:[/B][/I] 14N beam, CH2 187
um
trigger: MM1,2,3,4,5 + CATS%, EXL%, PPT%
|
|
Fixed | e744 |
Fri May 25 21:34:19 2018 |
e744 Iulan, Fairouz, Valerie | DAQ | Hardware | CH2 | Problem of FAG validation +change of ADC parameter for TAC signal | The Time signal MM_PPT is now in the parameter
MCP_HF of the ADC.
The problem was on the FAG signal validation |
|
Fixed | e744 |
Fri May 25 17:51:45 2018 |
e744 Iulan Valérie | RUN | General | CH2 | Run 1008 starting runs with 14N | [U][B]BAD RUN FOR 14N[/B][/U]
Run 1008 BAD RUN 0 Events
|
  |